• Step 1: power on the Z-Wave curta in motor controller.
• Step 2: activate inclusion mode on your Z-Wave controller.
• Step 3: activate inclusion mode of the curtain motor co ntrolle r by triple p ress the network
inclusion/exclusion button. The cur tain motor controller will be included to Z-Wave network.
Product Description
The curtain motor controller is a universa l, Z-Wave Plus compatible, elec tric moto r control ler. The device
allows for controlling motors of roller bl inds and ve netian bl inds, which are single phase AC powere d. The
curtain motor controller allows for prec ise posit ioning of a r oller blind or venetian blind slats. Precise
positioning is available for the motors eq uipped wi th mechan ic and electronic end switches. Th e device
also allows for controlling on/off of lig hts. The module may be cont rolled wi relessl y, through the Z-Wave
network primary controller, or through th e switch ke ys connec ted to it. In a ddition, the curtain motor
controller is equipped with Power Meteri ng and over c urrent pr otection.
The curtain motor controller can be includ ed and oper ated in any Z -Wave netwo rk with oth er Z-Wave
certified devices from other manufacturers and/ or other ap plicati ons. All non-battery operated nodes
within the network will act as repeaters reg ardless o f vendor to i ncrease r eliability of the network.
1
Page 2
The encryption mode that the curtain motor controll er suppor ts is S2 Unau thenticated. When the curtain
motor controller is being included into a Z- Wave network, you can use your prim ary contr oller/g ateway to
enable encryption mode or disable encryp tion. (Th e primary c ontroller/gateway shall support encryp tion
mode configuration). The cur tain moto r controller supports OTA and can upda te firmwa re wirele ssly.
Main Fe atures:
• Compatible with any Z-Wave or Z-Wave+ Cont roller,
• Controlled by Sunricher EasyHome or any ot her Z-Wave controller,
• Advanced microprocessor control
• Active element: electromagnetic, micro-gap rel ay switch
• The device may be opera ted by mome ntary or to ggle switches, and by dedicated roller blind c ontrol
switches
• Connected motor's current and historical power co nsumpti on measured
• Over current protection
• To be installed in wall switch boxes of dimensi ons allow ing for ins tallation, conforming to provisions of
applicable regulations
• The curtain motor con troller s upports O TA and can update firmware wi relessl y
Product Data
Z-Wave Frequency
Input Voltage
Output Voltage
908.42 MHz (US)
AC100-240V
AC100-240V
Resistive loads:4A
Max. Load Current
Capacitive/inductive loads:2A
Operating temperature
Relative humidity
Dimensions
Installation Guide
Please read carefully the enclosed user ma nual befo re instal lation of the curtain motor controller, in orde r
to ensure an error-free functioning.
ATTENTION: Prior to the assembl y of the prod uct, the vo ltage net work has to be switched OFF and
ensured against re-switching.
0 to 40°C
8% to 80%
45.5x45x20.3mm
Inclusion (adding to a Z-Wave n etwork)
1. Set primary controller/gateway into inclusio n mode (Ple ase refer t o your primary controller ’s manual on
how to turn your controller into inclusion ).
2. Power on the curtain motor controller and set it into in clusion m ode. There are two methods to set the
curtain motor controller into inclusio n mode:
1)Tripl e press the n etwork inclusion/exclusion button, it will set the cu rtain mot or contro ller into inclusion
2
Page 3
. 6 seconds timeout if there is no reply from the Z-Wave primary controller, repea t the opera tion.
mode
2)When the value of configuration parame ter 8 is set as 1 , triple pr ess the swi tch connected to S1, it will
set the curtain motor controller into inclusion mod e. 6 second s timeout i f there is no reply from the Z-Wave
primary controller, repeat the operatio n.
3. The curtain motor co ntrolle r will be add ed to the Z-Wav e network .
Exclusion (removing from a Z-Wave netw ork)
1. Set th e primary controller/gateway into exclus ion mode (P lease ref er to your primary controllers
manual on how to set your controller into excl usion).
2. Power on the curtain motor controller and set it into ex clusion m ode. There are two methods to set the
curtain motor controller into exclusio n mode:
1)Tripl e press the n etwork inclusion/exclusion button, it will set the cu rtain mot or contro ller into exclusion
mode. 6 seconds timeout if there is no reply from the Z-Wave primary controller, r epeat the o peratio n.
2)When the value of configuration parame ter 8 is set as 1 , triple pr ess the swi tch connected to S1, it will
set the curtain motor controller into exclusion mod e. 6 second s timeout i f there is no reply from the ZWave prim ary contr oller, repeat the operation.
3. The curtain motor co ntrolle r will be rem oved from the Z-Wave net work.
Factory Reset
Press and hold down network inclusion/ex clusion b utton for o ver 10 seconds, the curtain motor controller
will be reset to factory defaults.
Configure Parameter 3 to Set Wor king Mode
1. When parameter 3 value is configured as 0, li ght mode: e ither S1 or S 2 can contr ol both Q1 and Q2,
short pressing or holding down will be recog nized aut omatica lly. For detailed config uration p lease ref er to
configuration parameter 7.
Note: when configured as light mode, endpo int 1 refle cts to rela y 1 (Q1), end point 2 reflects to relay 2
(Q2).
2. When parameter 3 value is configured as 1, sh utter mod e without p osition ing: S1 and S2 are only valid
while held down. Hold down S1, relay 1 (Q1) ON, re lay 2 (Q2) OF F. Hold down S2 , relay 2 (Q2 ) ON, relay 1
(Q1) OFF.
3. When parameter 3 value is configured as 2, sh utter mod e with posi tioning : S1 and S2 are only valid
while held down. Hold down S1, relay 1 (Q1) ON, re lay 2 (Q2) OF F. Hold down S2 , relay 2 (Q2 ) ON, relay 1
(Q1) OFF. When reaching any end’s po sitioni ng, both relays will be OFF.
4. When parameter 3 value is configured as 3, ve netian mo de (up/do wn and slats rotation): Hold down S1,
relay 1 (Q1) ON, relay 2 (Q2) OFF. Hold down S2, relay 2 (Q2) ON, relay 1 (Q1) OFF. Wh en reachi ng any
end’s positioning , both rela ys will be OF F. This mode supports shutt er dim comm and, whic h means it
supports the secondary switch of command class SWIT CH_MULTILEVEL_START_LEVEL_CHANGE.
Positioning Calibration
Calibration is a process during which a curt ain motor c ontroll er learns the position of the limit switches
and a motor characteristic. Calibratio n is mandat ory when th e working mode of the curtain motor
controller is Shutter mode with position ing and ven etian mod e (up/down and slat rotation).Connect the
controller to the motor according to wirin g diagram , there are t wo calibr ation methods as follows:
3
Page 4
1. Calibration through the calibration b utton, sh ort press t he button t wice, calibration starts automatically.
2. Set th e configuration parameter 6 value to 1, calibr ation sta rts autom atically.
Secene Control
Users can configure scenes using command c lass SCEN E_ACTUATOR _CONF_S ET, and activ ate the
scenes using command class SCENE_ACTIVATION_SET.
Activate Scenes Using Switch S1 S2
Users can configure configuration para meter 9 to de cide whet her to send scene activation command
using command class CENTRAL_SCENE_NO TIFICATION.
The scene ID and key attribute supported by switch S1 and S 2 are as foll ows:
Switc h Number
Suppo rt Action type
Short p ress once
Short p ress twice
Scene I D
1
1
Key Attr ibute
Key pre ssed once
Key pre ssed twice
S1
Short p ress 3 times
Press a nd hold, relea se
Short p ress once
Short p ress twice
1
1
2
2
Key pre ssed 3 times
Key held do wn an d released
Key pre ssed once
Key pre ssed twice
S2
Short p ress 3 times
Press a nd hold, relea se
2
2
Key pre ssed 3 times
Key held do wn an d released
Default configuration of CENTRAL_SCE NE_CONF IGURATION_SET is Slow R efresh = 1( send Key He ld
Down every 55s when the switch is pressed and he ld down).
Association
Z-Wave de vices con trol othe r Z-Wave devi ces. The relationship between on e device co ntrolli ng another
device is called association. In order to co ntrol a different device, the controlling device nee ds to maint ain
a list of devices that will receive controll ing comma nds. These lists are called associ ation gro ups and the y
are always related to certain events (e.g. button pre ssed). In c ase the eve nt happens all devices stored in
the respective association group will re ceive a com mon wirel ess command.
Association Groups:
Association
Groups
Group 1
Group
Name
Lifeline
Max
Nodes
5
Description
1. When press an d hol d down “K2” butto n for 1 0S to reset the
device, send " Dev ice Reset Local ly No tif ication" to ass oci ated
devices of thi s gro up to report fact ory r eset information .
2. When over loa d det ected, send "NO TIF ICATIO N_REPORT " to
associated d evi ces of this group .
4
Page 5
Group 2
REP EP1
3. Report ener gy me ter actively.
4. When action o f S1 an d S2 is detected, s end
CENTRAL_ SCENE_ N OTIFICATION_ V3
this group.
When endpoin t 1 sta te changes, sen d
5
"SWITCH_MU LTILEV EL_ REPORT" to associate d dev ice s of this
group.
to associate d dev ices of
Group 3
REP EP2
5
When endpoin t 2 sta te changes, sen d
"SWITCH_BI NARY_ REP ORT" to a ssociated device s of th is group.
Set and unset associations:
(Note: All association information will b e cleared a utomati cally once the curtain motor controller is
excluded from a network.)
Set association by operating primary con troller /gatewa y to send packets to the curtain motor controller:
The primary controller/gateway sends p ackets to t he curtai n motor con troller using
"COMMAND_CLASS_ASSOCIATION" or "CO MMAND_C LASS_MULTI_CHANNEL _ASSOCI ATION".
Node Information Frame
The Node Information Frame is the business card of a Z-Wave device. It contains informat ion about t he
device type and the technical capabiliti es. The inclusion and exclusion of the device i s confirm ed by
sending out a Node Information Frame. Besi de this it ma y be needed f or certai n network operations to
send out a Node Information Frame.
How to send out Node Information Frame:
When the curtain motor controller is set to inclusion /exclus ion mode ag ain, it will send out Node
Information Frame, there are 2 kinds of operation as fo llows:
1. triple press the K2 button, the curtain motor contro ller will b e set to incl usion/exclusion mode, then send
out Node Information Frame.
2. When the curtain motor controller is under inclusi on mode, th ere are two k inds of operation:
1) Triple press K2 button, the curtain motor controlle r will be set t o inclusi on mode again, and send out
Node Information Frame.
2) Power off and power on t he curtai n motor con troller, it will be set to inclusion mode automat ically, and
send out Node Information Frame.
Technical Data
5
Page 6
Wireless Range
up to 100 m outside, on average up to 40 m inside buil dings
OverCurrentAlarm When connectingtoresistiveload overcurrentvalu eis4 1A When
connecting to a motor or capacitive load, ov er curren t value is 2. 1A. Over current relays will be
closed.
: , ..
POWER_MANAGEMENT_OVERCURRENT_DETE
Trigger ring Even t
CTED(06)
Configuration Command Class
Parameter
SizeDescription(decimal numeral )Default Value
Enable/disable the curtain motor controller to
report state change percentage threshold
(report only when change value at the
specified percentage), if enabled, report when
the value reaches both 0% and 99%. When the
0x02(2)
11
working mode is configured as light mode, as
long as the state changes, the state change
percentage threshold will be reported.
SWITCH_MULTILEVEL_REPORT
0: disable to report actively
1-10: value to report, unit is one percent
Working mode
0x03(3)12
0: light mode
1: Shutter mode without positioning
2: Shutter mode with positioning
3: venetian mode (up/down and slats rotation)
Enable/disable to save positioning
percentage, record and save current
positioning every time when the curtain moves
0x04(4)11
to specified position, if the working mode is
configured as light mode, record on/off state.
0x00: disable
0x01: enable
Enable/disable over current protection
0: disable
1: enable, when over current detected, there
0x05(5)11
are two methods to cancel alarm:
1. short press either switch button S1 or S2,
the alarm will last at least 1 minute and then be
cancelled.
2. re-power on the curtain motor controller
8
Page 9
Only value 1 can be written in, which means
starting positioning calibration.
When read,
0x01: positioning calibration completed
0x06(6)10
0x00: positioning not calibrated
This parameter is only valid when parameter 3
configured as shutter mode with positioning or
venetian mode (up/down and slats rotation).
When parameter 3 value configured as 0 (light
mode), configuration of button S1 and S2
control.
Value=0
Short press S1 to switch ON/OFF Q1. Press and
hold down S1 to switch ON Q1, then release to
switch OFF Q2.
Short press S2 to switch ON/OFF Q2. Press and
hold down S2 to switch ON Q2, then release to
switch OFF Q2.
Value=1
Short press S1 to switch ON/OFF Q1. When S1
is pressed and held down, then released, not
processed.
Short press S2 to switch ON/OFF Q2. When S2
pressed and held down, then released, not
processed.
0x07(7)10
Value=2
Press and hold down S1 to switch ON Q1, then
release to switch OFF Q2. When S1 short
pressed, not processed.
Press and hold down S2 to switch ON Q2, then
release to switch OFF Q2. When S2 short
pressed, not processed.
Value=3
Short press S1 or S2 to switch ON/OFF of both
Q1 and Q2 simultaneously. When S1 or S2
pressed and held down, not processed
Value=4
Press and hold down S1 to switch ON Q1 and
Q2. When S1 short pressed, not processed.
Press and hold down S2 to switch OFF Q1 and
Q2. When S2 short pressed, not processed.
9
Page 10
0x08(8)
0x09(9)
Enable/disable to add the device to or remove
it from a Z-Wave network through button S1.
Please refer to the parts of inclusion and
exclusion for details.
11
0: enable
1: disable
Enable/disable to send scene activation
command
CENTRAL_ SCENE_NOTIFICATION_ V3 when
the switches S1 and S2 are pressed.
0: disable to send for action of both S1 and S2
11
1: enable to send for action of both S1 and S2
2: enable to send for action of only S1
3: enable to send for action of only S2
Power change absolute threshold report, unit is W
0: disable absolute threshold report function
0x0A(10)110
1-100: value of the power change absolute
threshold, if power change value is over the
threshold value, report the power change value
using METER_REPORT
Current change absolute threshold, unit is 0.1A
0: disable absolute threshold function
0x0B(11)
10
1-10: value of the current change absolute
threshold, if current change value is over the
threshold value, report the current change value
using METER_REPORT
Voltage change absolute threshold, unit is 1V
0x0C(12)
0: disable absolute threshold function
10
1-10: value of the voltage change absolute
threshold, if voltage change value is over the
threshold value, report the voltage change value
using METER_REPORT
10
Page 11
Slats rotation time, unit is 0.1S
0: disable the function
115 (1.5S)0x0d(13)
5-250 (0.5S-25S): value of the slats rotation time
This parameter is only valid when parameter 3 is
configured as venetian mode (up/down and slats
rotation).
Time cycle to report the values of energy
consumption, voltage, current and load power
actively
43600 (1 hour)0x0E(14)
60-2678400 (31 days), value of the time cycle,
unit is S.
Wiring Diagram
Notes for the diagrams:
L - terminal for live lead
N - terminal for neutral lead
S1 - terminal for switch key No. 1 (enable to set the device into inclusion/exclusion mode)
S2 - terminal for switch key No. 2
Q1 - outp ut terminal no. 1 for electrical motor
Q2 - outp ut terminal no. 2 for electrical motor
K1 - positioning calibration button when working mode is configured as shutter mode with
positioning or v enetian mode (up/down and slats rotation)
K2 - inclusion/exclusion button (used to add or remove a device from the system)
Compatible Load Types
Supported load types
Lamp and resistive loads
Induc tive loads
Capacitive loads
11
100-240V~
Max. 4A
Max. 2A
Max. 2A
Page 12
(1) Curtain Motor Connection Diagram
Neu tral
Liv e
S2S1
DOW N
K1
AC 10 0-240 V
L
Curtain Motor
Controlle r
MAX :2A ( )
Mad e in Chin a
NN
/
S2
SR-ZV9080 A-B(908.42MHz)
S1
FCC I D:XXX SR908 0A
UP
Rat ings: 120V~ ,60Hz ,MAX: 4A( )
K2
Q1
Q2
(2) Light Mode Connection Diagram
2
S2S1
S
SR-ZV9080 A-B(908.42MHz)
1
S
FCC I D:XXX SR908 0A
Rat ings: 120V~ ,60Hz ,MAX: 4A( )
K2
AC 10 0-240 V
Q1
Q2
L
Curtain Motor
Controlle r
MAX :2A ( )
K1
Mad e in Chin a
NN
/
Neu tral
Liv e
12
Loading...