Sunricher SR-ZV9080A-B User Manual

Page 1
Z-Wave Curtain Motor Controller SR-ZV9080A-B
Function Introduction
Swit ch inpu t
2
S
SR-ZV9080A-B(908.42MHz)
S1
FCC ID: XX XSR90 80 A
Netw ork inc lusio n/ excl usion b utton
Load o utput
Ratin gs :120V ~, 60Hz, MA X:4A( )
Q1
Q2
Safety & Wa rnings
DO NOT install with pow er applie d to device .
DO NOT expose the devic e to moistu re.
Quick Start
How to install:
K2
AC 100- 24 0V
L
Curtain Motor
Controller
MAX :2 A ( )
K1
Made in C hi na
NN
/
Cali brati on butt on
AC pow er inpu t
Step 1: power on the Z-Wave curta in motor controller.
Step 2: activate inclusion mode on your Z-Wave controller.
inclusion/exclusion button. The cur tain motor controller will be included to Z-Wave network.
Product Description
The curtain motor controller is a universa l, Z-Wave Plus compatible, elec tric moto r control ler. The device allows for controlling motors of roller bl inds and ve netian bl inds, which are single phase AC powere d. The curtain motor controller allows for prec ise posit ioning of a r oller blind or venetian blind slats. Precise positioning is available for the motors eq uipped wi th mechan ic and electronic end switches. Th e device also allows for controlling on/off of lig hts. The module may be cont rolled wi relessl y, through the Z-Wave network primary controller, or through th e switch ke ys connec ted to it. In a ddition, the curtain motor controller is equipped with Power Meteri ng and over c urrent pr otection.
The curtain motor controller can be includ ed and oper ated in any Z -Wave netwo rk with oth er Z-Wave certified devices from other manufacturers and/ or other ap plicati ons. All non-battery operated nodes within the network will act as repeaters reg ardless o f vendor to i ncrease r eliability of the network.
1
Page 2
The encryption mode that the curtain motor controll er suppor ts is S2 Unau thenticated. When the curtain motor controller is being included into a Z- Wave network, you can use your prim ary contr oller/g ateway to enable encryption mode or disable encryp tion. (Th e primary c ontroller/gateway shall support encryp tion mode configuration). The cur tain moto r controller supports OTA and can upda te firmwa re wirele ssly.
Main Fe atures:
• Compatible with any Z-Wave or Z-Wave+ Cont roller,
• Controlled by Sunricher EasyHome or any ot her Z-Wave controller,
• Advanced microprocessor control
• Active element: electromagnetic, micro-gap rel ay switch
• The device may be opera ted by mome ntary or to ggle switches, and by dedicated roller blind c ontrol switches
• Connected motor's current and historical power co nsumpti on measured
• Over current protection
• To be installed in wall switch boxes of dimensi ons allow ing for ins tallation, conforming to provisions of applicable regulations
• The curtain motor con troller s upports O TA and can update firmware wi relessl y
Product Data
Z-Wave Frequency
Input Voltage
Output Voltage
908.42 MHz (US)
AC100-240V
AC100-240V
Resistive loads:4A
Max. Load Current
Capacitive/inductive loads:2A
Operating temperature
Relative humidity
Dimensions
Installation Guide
Please read carefully the enclosed user ma nual befo re instal lation of the curtain motor controller, in orde r to ensure an error-free functioning.
ATTENTION: Prior to the assembl y of the prod uct, the vo ltage net work has to be switched OFF and ensured against re-switching.
0 to 40°C
8% to 80%
45.5x45x20.3mm
Inclusion (adding to a Z-Wave n etwork)
1. Set primary controller/gateway into inclusio n mode (Ple ase refer t o your primary controller ’s manual on how to turn your controller into inclusion ).
2. Power on the curtain motor controller and set it into in clusion m ode. There are two methods to set the curtain motor controller into inclusio n mode:
1)Tripl e press the n etwork inclusion/exclusion button, it will set the cu rtain mot or contro ller into inclusion
2
Page 3
. 6 seconds timeout if there is no reply from the Z-Wave primary controller, repea t the opera tion.
mode
2)When the value of configuration parame ter 8 is set as 1 , triple pr ess the swi tch connected to S1, it will set the curtain motor controller into inclusion mod e. 6 second s timeout i f there is no reply from the Z-Wave primary controller, repeat the operatio n.
3. The curtain motor co ntrolle r will be add ed to the Z-Wav e network .
Exclusion (removing from a Z-Wave netw ork)
1. Set th e primary controller/gateway into exclus ion mode (P lease ref er to your primary controllers manual on how to set your controller into excl usion).
2. Power on the curtain motor controller and set it into ex clusion m ode. There are two methods to set the curtain motor controller into exclusio n mode:
1)Tripl e press the n etwork inclusion/exclusion button, it will set the cu rtain mot or contro ller into exclusion mode. 6 seconds timeout if there is no reply from the Z-Wave primary controller, r epeat the o peratio n.
2)When the value of configuration parame ter 8 is set as 1 , triple pr ess the swi tch connected to S1, it will set the curtain motor controller into exclusion mod e. 6 second s timeout i f there is no reply from the Z­Wave prim ary contr oller, repeat the operation.
3. The curtain motor co ntrolle r will be rem oved from the Z-Wave net work.
Factory Reset
Press and hold down network inclusion/ex clusion b utton for o ver 10 seconds, the curtain motor controller will be reset to factory defaults.
Configure Parameter 3 to Set Wor king Mode
1. When parameter 3 value is configured as 0, li ght mode: e ither S1 or S 2 can contr ol both Q1 and Q2, short pressing or holding down will be recog nized aut omatica lly. For detailed config uration p lease ref er to configuration parameter 7. Note: when configured as light mode, endpo int 1 refle cts to rela y 1 (Q1), end point 2 reflects to relay 2 (Q2).
2. When parameter 3 value is configured as 1, sh utter mod e without p osition ing: S1 and S2 are only valid while held down. Hold down S1, relay 1 (Q1) ON, re lay 2 (Q2) OF F. Hold down S2 , relay 2 (Q2 ) ON, relay 1 (Q1) OFF.
3. When parameter 3 value is configured as 2, sh utter mod e with posi tioning : S1 and S2 are only valid while held down. Hold down S1, relay 1 (Q1) ON, re lay 2 (Q2) OF F. Hold down S2 , relay 2 (Q2 ) ON, relay 1 (Q1) OFF. When reaching any end’s po sitioni ng, both relays will be OFF.
4. When parameter 3 value is configured as 3, ve netian mo de (up/do wn and slats rotation): Hold down S1, relay 1 (Q1) ON, relay 2 (Q2) OFF. Hold down S2, relay 2 (Q2) ON, relay 1 (Q1) OFF. Wh en reachi ng any end’s positioning , both rela ys will be OF F. This mode supports shutt er dim comm and, whic h means it supports the secondary switch of command class SWIT CH_MULTILEVEL_START_LEVEL_CHANGE.
Positioning Calibration
Calibration is a process during which a curt ain motor c ontroll er learns the position of the limit switches and a motor characteristic. Calibratio n is mandat ory when th e working mode of the curtain motor controller is Shutter mode with position ing and ven etian mod e (up/down and slat rotation).Connect the controller to the motor according to wirin g diagram , there are t wo calibr ation methods as follows:
3
Page 4
1. Calibration through the calibration b utton, sh ort press t he button t wice, calibration starts automatically.
2. Set th e configuration parameter 6 value to 1, calibr ation sta rts autom atically.
Secene Control
Users can configure scenes using command c lass SCEN E_ACTUATOR _CONF_S ET, and activ ate the scenes using command class SCENE_ACTIVATION_SET.
Activate Scenes Using Switch S1 S2
Users can configure configuration para meter 9 to de cide whet her to send scene activation command using command class CENTRAL_SCENE_NO TIFICATION.
The scene ID and key attribute supported by switch S1 and S 2 are as foll ows:
Switc h Number
Suppo rt Action type
Short p ress once
Short p ress twice
Scene I D
1
1
Key Attr ibute
Key pre ssed once
Key pre ssed twice
S1
Short p ress 3 times
Press a nd hold, relea se
Short p ress once
Short p ress twice
1
1
2
2
Key pre ssed 3 times
Key held do wn an d released
Key pre ssed once
Key pre ssed twice
S2
Short p ress 3 times
Press a nd hold, relea se
2
2
Key pre ssed 3 times
Key held do wn an d released
Default configuration of CENTRAL_SCE NE_CONF IGURATION_SET is Slow R efresh = 1( send Key He ld Down every 55s when the switch is pressed and he ld down).
Association
Z-Wave de vices con trol othe r Z-Wave devi ces. The relationship between on e device co ntrolli ng another device is called association. In order to co ntrol a different device, the controlling device nee ds to maint ain a list of devices that will receive controll ing comma nds. These lists are called associ ation gro ups and the y are always related to certain events (e.g. button pre ssed). In c ase the eve nt happens all devices stored in the respective association group will re ceive a com mon wirel ess command.
Association Groups:
Association
Groups
Group 1
Group
Name
Lifeline
Max
Nodes
5
Description
1. When press an d hol d down “K2” butto n for 1 0S to reset the device, send " Dev ice Reset Local ly No tif ication" to ass oci ated devices of thi s gro up to report fact ory r eset information .
2. When over loa d det ected, send "NO TIF ICATIO N_REPORT " to associated d evi ces of this group .
4
Page 5
Group 2
REP EP1
3. Report ener gy me ter actively.
4. When action o f S1 an d S2 is detected, s end CENTRAL_ SCENE_ N OTIFICATION_ V3
this group.
When endpoin t 1 sta te changes, sen d
5
"SWITCH_MU LTILEV EL_ REPORT" to associate d dev ice s of this group.
to associate d dev ices of
Group 3
REP EP2
5
When endpoin t 2 sta te changes, sen d "SWITCH_BI NARY_ REP ORT" to a ssociated device s of th is group.
Set and unset associations:
(Note: All association information will b e cleared a utomati cally once the curtain motor controller is
excluded from a network.)
Set association by operating primary con troller /gatewa y to send packets to the curtain motor controller:
The primary controller/gateway sends p ackets to t he curtai n motor con troller using
"COMMAND_CLASS_ASSOCIATION" or "CO MMAND_C LASS_MULTI_CHANNEL _ASSOCI ATION".
Node Information Frame
The Node Information Frame is the business card of a Z-Wave device. It contains informat ion about t he
device type and the technical capabiliti es. The inclusion and exclusion of the device i s confirm ed by
sending out a Node Information Frame. Besi de this it ma y be needed f or certai n network operations to
send out a Node Information Frame.
How to send out Node Information Frame:
When the curtain motor controller is set to inclusion /exclus ion mode ag ain, it will send out Node
Information Frame, there are 2 kinds of operation as fo llows:
1. triple press the K2 button, the curtain motor contro ller will b e set to incl usion/exclusion mode, then send
out Node Information Frame.
2. When the curtain motor controller is under inclusi on mode, th ere are two k inds of operation:
1) Triple press K2 button, the curtain motor controlle r will be set t o inclusi on mode again, and send out
Node Information Frame.
2) Power off and power on t he curtai n motor con troller, it will be set to inclusion mode automat ically, and
send out Node Information Frame.
Technical Data
5
Page 6
Wireless Range
up to 100 m outside, on average up to 40 m inside buil dings
SDK
Explorer Frame Support
Device Type
Generic Device Class
Specific Device Class
Role Type
Endpoint 1 device type
GENERIC_TYPE_SWITCH_MULTILEVEL /SPECIF IC_TYPE _CLASS_C_MOTOR_CO NTROL
Endpoint 2 device type:
GENERIC_TYPE_SWITCH_BINARY/SP ECIFIC_ TYPE_PO WER_SWITCH_BINARY
SUPPORTED COMMAND CLASS
Root Device Command List
Window Covering Position/Endpoint Aware
GENERIC_TYPE_SWITCH_MULTILEVEL
SPECIFIC_TYPE_CLASS_C_MOTOR_C ONTROL
Always On Slave (AOS)
Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO
6.71.03
Yes
Support S2/S0
V2
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_TRANSPORT_SERVICE
COMMAND_CLASS_SUPERVIS ION
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_SWITCH_MULTILEVE L
COMMAND_CLASS_ASSOCIATI ON
COMMAND_CLASS_ASSOCIATI ON_GRP_ INFO
COMMAND_CLASS_VERSION
COMMAND_CLASS_MANUFACTURER_SPEC IFIC
COMMAND_CLASS_DEVICE_RESET_LOC ALLY
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_CONFIGURATION
V1
V1
V2
V1
V1 YES
V3 YES
V2 YES
V1 YES
V2 YES
V2 YES
V1 YES
V1 YES
V1 YES
COMMAND_CLASS_FIRMWAR E_UPDATE_MD
COMMAND_CLASS_NOTIFICATION
COMMAND_CLASS_METER
V4 YES
V8 YES
V3 YES
6
Page 7
COMMAND_CLASS_MULTI_CHA NNEL
V4 YES
COMMAND_CLASS_MULTI_CHA NNEL_AS SOCIATION
COMMAND_ CLASS_ SCEN E_ A CTIVATION
COMMAND_ CLASS_ SCEN E_ A CTUATOR_ CONF
COMMAND_ CLASS_ CENT RAL_ SCENE
Endpoint 1 Command List
Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVIS ION
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_SWITCH_MULTILEVE L
COMMAND_CLASS_ASSOCIATI ON
V3 YES
V1 YES
V1 YES
V3 YES
Support S2/S0
V2
V1
V1
V1
V1 YES
V3 YES
V2 YES
COMMAND_CLASS_ASSOCIATI ON_GRP_ INFO
COMMAND_CLASS_MULTI_CHA NNEL_AS SOCIATION
COMMAND_ CLASS_ SCEN E_ A CTIVATION
COMMAND_ CLASS_ SCEN E_ A CTUATOR_ CONF
Endpoint 2 Command List
Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVIS ION
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_ASSOCIATI ON
V1 YES
V3 YES
V1 YES
V1 YES
Support S2/S0
V2
V1
V1
V1
V1 YES
V2 YES
COMMAND_CLASS_ASSOCIATI ON_GRP_ INFO
COMMAND_CLASS_MULTI_CHA NNEL_AS SOCIATION
COMMAND_ CLASS_ SCEN E_ A CTIVATION
COMMAND_ CLASS_ SCEN E_ A CTUATOR_ CONF
7
V1 YES
V3 YES
V1 YES
V1 YES
Page 8
Notification Report
Notification Type
NOTIFICATION_TYPE_POWER_MA
NAGEMENT(08)
Over Current Alarm When connecting to resistive load over current valu e is 4 1A When
connecting to a motor or capacitive load, ov er curren t value is 2. 1A. Over current relays will be
closed.
: , . .
POWER_MANAGEMENT_OVERCURRENT_DETE
Trigger ring Even t
CTED(06)
Configuration Command Class
Parameter
Size Description(decimal numeral ) Default Value
Enable/disable the curtain motor controller to report state change percentage threshold (report only when change value at the specified percentage), if enabled, report when the value reaches both 0% and 99%. When the
0x02(2)
1 1
working mode is configured as light mode, as long as the state changes, the state change percentage threshold will be reported. SWITCH_MULTILEVEL_REPORT
0: disable to report actively 1-10: value to report, unit is one percent
Working mode
0x03(3) 1 2
0: light mode 1: Shutter mode without positioning 2: Shutter mode with positioning 3: venetian mode (up/down and slats rotation)
Enable/disable to save positioning percentage, record and save current positioning every time when the curtain moves
0x04(4) 1 1
to specified position, if the working mode is configured as light mode, record on/off state.
0x00: disable 0x01: enable
Enable/disable over current protection
0: disable 1: enable, when over current detected, there
0x05(5) 1 1
are two methods to cancel alarm:
1. short press either switch button S1 or S2, the alarm will last at least 1 minute and then be cancelled.
2. re-power on the curtain motor controller
8
Page 9
Only value 1 can be written in, which means starting positioning calibration. When read, 0x01: positioning calibration completed
0x06(6) 1 0
0x00: positioning not calibrated
This parameter is only valid when parameter 3 configured as shutter mode with positioning or venetian mode (up/down and slats rotation).
When parameter 3 value configured as 0 (light mode), configuration of button S1 and S2 control.
Value=0 Short press S1 to switch ON/OFF Q1. Press and hold down S1 to switch ON Q1, then release to switch OFF Q2. Short press S2 to switch ON/OFF Q2. Press and hold down S2 to switch ON Q2, then release to switch OFF Q2.
Value=1 Short press S1 to switch ON/OFF Q1. When S1 is pressed and held down, then released, not processed. Short press S2 to switch ON/OFF Q2. When S2 pressed and held down, then released, not processed.
0x07(7) 1 0
Value=2 Press and hold down S1 to switch ON Q1, then release to switch OFF Q2. When S1 short pressed, not processed. Press and hold down S2 to switch ON Q2, then release to switch OFF Q2. When S2 short pressed, not processed.
Value=3 Short press S1 or S2 to switch ON/OFF of both Q1 and Q2 simultaneously. When S1 or S2 pressed and held down, not processed
Value=4 Press and hold down S1 to switch ON Q1 and Q2. When S1 short pressed, not processed. Press and hold down S2 to switch OFF Q1 and Q2. When S2 short pressed, not processed.
9
Page 10
0x08(8)
0x09(9)
Enable/disable to add the device to or remove it from a Z-Wave network through button S1. Please refer to the parts of inclusion and exclusion for details.
1 1
0: enable
1: disable
Enable/disable to send scene activation command CENTRAL_ SCENE_NOTIFICATION_ V3 when the switches S1 and S2 are pressed.
0: disable to send for action of both S1 and S2
1 1
1: enable to send for action of both S1 and S2
2: enable to send for action of only S1
3: enable to send for action of only S2
Power change absolute threshold report, unit is W
0: disable absolute threshold report function
0x0A(10) 1 10
1-100: value of the power change absolute threshold, if power change value is over the threshold value, report the power change value using METER_REPORT
Current change absolute threshold, unit is 0.1A
0: disable absolute threshold function
0x0B(11)
1 0
1-10: value of the current change absolute threshold, if current change value is over the threshold value, report the current change value using METER_REPORT
Voltage change absolute threshold, unit is 1V
0x0C(12)
0: disable absolute threshold function
1 0
1-10: value of the voltage change absolute threshold, if voltage change value is over the threshold value, report the voltage change value using METER_REPORT
10
Page 11
Slats rotation time, unit is 0.1S
0: disable the function
1 15 (1.5S)0x0d(13)
5-250 (0.5S-25S): value of the slats rotation time
This parameter is only valid when parameter 3 is configured as venetian mode (up/down and slats rotation).
Time cycle to report the values of energy consumption, voltage, current and load power actively
4 3600 (1 hour)0x0E(14)
60-2678400 (31 days), value of the time cycle, unit is S.
Wiring Diagram
Notes for the diagrams: L - terminal for live lead N - terminal for neutral lead S1 - terminal for switch key No. 1 (enable to set the device into inclusion/exclusion mode) S2 - terminal for switch key No. 2 Q1 - outp ut terminal no. 1 for electrical motor Q2 - outp ut terminal no. 2 for electrical motor K1 - positioning calibration button when working mode is configured as shutter mode with positioning or v enetian mode (up/down and slats rotation) K2 - inclusion/exclusion button (used to add or remove a device from the system)
Compatible Load Types
Supported load types
Lamp and resistive loads
Induc tive loads
Capacitive loads
11
100-240V~
Max. 4A
Max. 2A
Max. 2A
Page 12
(1) Curtain Motor Connection Diagram
Neu tral
Liv e
S2 S1
DOW N
K1
AC 10 0-240 V
L
Curtain Motor
Controlle r
MAX :2A ( )
Mad e in Chin a
NN
/
S2
SR-ZV9080 A-B(908.42MHz)
S1
FCC I D:XXX SR908 0A
UP
Rat ings: 120V~ ,60Hz ,MAX: 4A( )
K2
Q1
Q2
(2) Light Mode Connection Diagram
2
S2 S1
S
SR-ZV9080 A-B(908.42MHz)
1
S
FCC I D:XXX SR908 0A
Rat ings: 120V~ ,60Hz ,MAX: 4A( )
K2
AC 10 0-240 V
Q1
Q2
L
Curtain Motor
Controlle r
MAX :2A ( )
K1
Mad e in Chin a
NN
/
Neu tral
Liv e
12
Loading...