ENERGY SAVING TIPS ................................................................... 2
SPECIFICATIONS ........................................................................... 3
BEFORE USE ................................................................................ 4
PARTS .......................................................................................... 5
INSTALLATION ............................................................................... 6
MOUNTING OF THE EXHAUST PIPE ................................................ 7
INSTALLATION OF THE CARBON FILTER .......................................... 8
OPERATION ................................................................................. 9
NOTICE ....................................................................................... 12
DRAINAGE .................................................................................. 13
MAINTENANCE ............................................................................ 15
TROUBLE SHOOTING ................................................................... 16
DEFECTIVE NOTICE ..................................................................... 17
GUARANTEE ............................................................................... 18
SAFETY POWER SUPPLY
CORD ............................................................................................. 19
I
105-09-294 wa-1300 I
Thank you for choosing the portable air conditioner from SPTUSA, a leading brand in indoor air treatment. We would like you to enjoy the many benefits this unit offers, so please take the time to read this manual carefully and take
full advantage of the many advanced features that your SPTusA Air Conditioner offers you.
SPTUSA specialize in complete indoor environment control, manufacturing
world-class air conditioners, dehumidifiers and air purifiers with innovative
technology.
In designing these advanced products, we have listened carefully to our
customers and have passed their views onto our research and development laboratories.
We wish you many years of enjoyable use.
After reading this manual, please keep it in a safe place for future reference.
Energy Saving Tips
Please use the unit in the recommended room size. (Refer to PAGE 3).
Do not locate the air conditioner where furniture or other objects can obstruct the airflow.
Keep blinds/curtains closed during the sunniest part of the day.
Close fireplace damper and floor or wall grills so that cool air does not escape through the chimney or ductwork.
Keep filters clean.
Set the unit to maximum cooling and high-speed fan initially, then adjust the unit to a comfortable setting.
NOTE: It is recommended to turn on the air conditioner when the room temperature is around 75°F. Do not wait until the room is excessively hot.
I
105-09-294 wa-1300 I
Model no.
Cooling capacity Heating capacity
Power/Am pere
consumption for cooling*
Power/Am pere
consumption for heating* Air volume (max. speed)
Humidity removal capacity Recommended room size
Power supply Compressor
Refrigerant Refrigerant load* Fan speed
Timer Working temperature
Thermostat
Exhaust pipe Net Weight
Dimension
WA-1300E WA-1310E
13000 BTU/hr
107 lW/9.4A
580m3/h
98 Pts/day
420sq.ft.
115V/60 Hz/1 phase
Cooling: 62°F ~ 110 °F
Heating: 41° F~ 80.6 ° F
14 x 21 x 30 in (WxDxH)
WA-1300H WA-1310H
13000 BTU/hr 13000 BTU/hr
107 lW/9.4A
1071W/9.4A
580m3/h
98 Pts/day
420sq.ft.
Rotary
R-22
15.2 oz 3
1~ 24 hours
62 ° F ~ 90 ° F
5 in x 59 in
86 Ibs.
REMARK:
1. The data marked with '*' may vary for technical reasons.
2. Measuring condition for above is: Cooling - RT80.6 °F, RH60% Heating - RT68 °F, RH60%
*RT means room temperature *RH means room humidity.
Un-insulated rooms such as sunrooms, garages, or attics should be less
than 420sq.ft. The following may effect the unit in reaching your set tempearature:
Outside Temperature, Room Size, Ceiling Height, Room Insulation,
Number of people in the room, Direct Sunlight and Source of Heat.
I
105-09-294 wa-1300 I
Important!
Transport the unit in an upright position only or leave in upright position for at least 2 hours before use. Keep at least 20 inches away from the
wall. (Figure 1 & 4)
Always place the unit on an even surface.
Make sure the unit is connected to a correctly grounded power supply
(refer to the rating label located at the back of the unit).
An opening in a window or wall is required to accommodate the
exhaust hose (kit supplied) to expel the warm air.
Do not cover or obstruct the appliance inlet or outlet grilles (Figure2).
To avoid the risk of shock, the product should never be used in
bathrooms, shower rooms or in any other steamy/wet areas (Figure 3).
FIG. 1
The unit will cool when the room temperature is between 62°F and
110°F depending on the thermostat setting.
Do not sit or place objects on the unit.
Do not touch the unit with wet/damp hands or when standing barefoot.
Avoid all contact with chemical based materials.
The filter must be used with the product at all times. When removing for
cleaning, always disconnect the power first.
Turn off the appliance when not in use.
For storage, drain all water and clean the unit / filters before storage.
Drainage of the water container is required before moving the unit or
putting it into storage.
If the electric socket is different from the plug provided, have a qualified
electrician replace the plug with a suitable one. Avoid the use of adaptors, multiple sockets and/or extension cords; if their use is
necessary, ensure that they conform to the current safety regulations.
Do not pull the power cord or place it near a source of heat; always
unroll it completely to avoid the possibility of dangerous overheating.
FIG. 2
FIG. 3
If the power cord is damaged, it must be replaced by a service agent or
a similarly qualified person. THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE
ABOVE INSTRUCTIONS ARE NOT FOLLOWED.
FIG. 4
I
105-09-294 wa-1300 I
Front Back
2 5
3 _6
FIG. 5
1. Control Panel
2. Air outlet
3. Carrying handle
4. Caster
Accessories
10. Inward adaptor - for insertion over hose and connect to back of the air conditioner.
11. Round connector - for insertion over hose and connects to plastic slider kit (or into hole
in the wall/window).
12. Exhaust hose: Length: 14"-59"
Diameter: 4.75"
13. Round cap for to cover round connector when unit not in use.
14.Plastic slider kit - for filling the open window space,
with circular opening for inserting the hose & round
connector. One set is 3pcs
(forms up to 58.5"L x 6.5W)
15. Drain tube for continuous drainage
16. Active carbon filter
17. Remote control
18. Water tray
5. Air filter
6. Air inlet
7. Exhaust air outlet
8. Water stopper / drainage point
9. Cord storage