Sunpentown WA-1140DE Installation Manual

DUAL-HOSE PORTABLE AIR CONDITIONER
USE AND CARE MANUAL
MODELS:
WA-9040DE · WA-9040DH · WA-1140DE
WA-1340DE · WA-1340DH
Thank you for purchasing SPT Air Conditioner, please read the Use and Care
future reference.
CONTENTS
Table of Contents 1 Introduction 2 Features 3 Identification of Parts Unit 3
Accessories and Window Kit 4
Installation Instructions 5 Control Panel 6 Remote control 7, 8 Operating Instructions
Operating modes 9 Cooling 10 Dry 11 Smart mode 12 Timer settings 13 Setting the clock 13
Super and Heater 14
Protection Features 15 Maintenance 16 Troubleshooting 17 Specifications 18 Warranty Info 19 Notes 20
1
Introduction
Thank you for choosing this portable air conditioner. It will provide you and your family with all of the “Home Comfort” requirements for your home, cottage or office. This appliance can be moved from room to room within your home and set-up in just minutes.
Electrical Specifications
1. All wiring must comply with local and national electrical codes and be installed by a qualified
electrician. Contact a qualified electrician with questions regarding the following instructions.
2. Check available power supply and resolve any wiring problems before installation and
operation of this unit.
3. For your safety and protection, this unit is grounded through the power cord plug when
plugged into a matching wall outlet. If you are not sure whether the wall outlets in your home
are properly grounded, please consult an electrician. Do not use plug adapters or extension
cords with this unit. If it is necessary to use an extension cord, use with heavy appliance
extension cord only (available at most local hardware stores).
Energy Saving Tips
Please use the unit in the recommended room size. (Refer to www.spt-usa.com).
Do not locate the air conditioner where furniture or other objects can obstruct the airflow.
Keep blinds/curtains closed during the sunniest part of the day.
Close the fireplace damper and floor or wall grills so that cool air does not escape through
the chimney or ductwork.
Keep the exhaust hose as short and straight as possible.
If unit is to be operated throughout the day, turn on the unit early, before the noon heat hits.
It is highly recommended to turn on the air conditioner when the room temperature is
around 75°F. Do not wait until the room gets excess ively hot.
Keep the filters clean.
Single Hose vs. Dual Hose
Single Hose: draws indoor air for both front cold air output and exhaust air (to cool compressor).
PROS: CONS:
Dual Hose: draws indoor air for front cold air output and outdoor air for exhaust air.
PROS:
CONS:
Fresh air is exchanged
Fresh air will delay the speed of ambient temperature drop
If outside temperature is lower than ambient, compressor cools down faster
and produces colder air output
Ambient temperature drops quickly
Same air circulating within the room, resulting in decreased oxygen level
and increased carbon dioxide
If outside temperature is too high, compressor cannot be cooled – resulting in increased temperature of front air output.
NOTE: It is suggested to remove the air intake hose and use as single hose system when outside temperature is over 95°F.
2
Features
The images in this manual are based on the
This unit is equipped with the following features:
Re-Start IC: Should there be a power outage, when power returns, unit will resume operating at last setting / mode.
Self-Evaporating Technology: Recycles the condensed water and evaporates it out with the exhaust air, for added cooling efficiency as well as energy efficiency.
Smart Mode: fuzzy logic operation
Super Mode: for cooling only models
Heater Mode: for units with heater option
Identification of Parts
Unit
1. Control panel
2. Air outlet / louver
3. Remote signal receptor
4. Remote controller
5. Transport handle
6. Air exhaust hose
7. Evaporator air intake
8. Air intake hose
9. Drain port
10. Power supply
3
external view of a standard model. Consequently, the shape may differ from that
Accessories
Installation Accessories
Window Kit Installation
windows, with vertical or horizontal applications.
certain types of windows. Please refer to Figures 1 and
PART & DESCRIPTION QUANTITY
1. Air inlet hose 1pc
Extends from 17 3/4” to 70 5/8”
2. Air outlet hose 1pc
Extends from 17 ¾” to 70 5/8”
3. Window exhaust adapter 2pcs
4. Adapter 2pcs
5. Window/patio door slider kit 1 set (3pcs)
From 28 3/8” up to 55 5/8”
The window kit has been designed to fit most standard However, it may be necessary for you to improvise or
modify some aspects of the installation procedures for 2 below for minimum and maximum window openings.
4
Installation Instructions
Selecting the best location
Best to place the unit near a window, patio door or French window. The shorter you can keep the intake/exhaust hoses, the more efficient the unit will run.
Keep a minimum space of 20 inches between the back of the unit to the wall or other obstacles.
Installing instructions
1. Install the adapters and window exhaust adapters to the hoses.
2. Fix the adapter end of the hose to the unit.
3. Extend the hose to the destined window/door to insure enough clearance.
4. Attach hose to slider kit
5. Repeat above steps for the other hose.
6. Install the slider kit to the window / door and adjust height accordingly. There are small openings on the side of the slider kit. Once the desire height is set, insert a small screw (not supplied) to keep in place.
Do not block the air outlet or intake with protective grid, curtain, shutter or other obstacles.
Keep a minimum clearance of 8” between the ends of air hoses.
Try to keep the air hoses as straight as possible, as in Figure 3.
Installation Sequence
1. Select a suitable location, with easy access to an electrical outlet.
2. Install the flexible air hoses and adjustable slider kit as depicted in Figure 3.
For COOLING mode, please install both the air intake and air
exhaust hose. Cooling capacity will decrease when using single air hose. However, to prevent compressor from overheating, when outdoor temperature is 35°C (95°F) or above, remove the air intake hose.
For DRY mode, remove air intake hose and install only the air exhaust hose.
2. For FAN and HEATER (Heating models), no hose installation required.
3. Plug unit to a grounded electrical outlet. Please select an appropriate power supply based on the requirements on the nameplate.
4. Press the power button to turn unit on.
Note: Do not use an extension cord with this appliance. If an extension cord must be used, use heavy appliance extension cords only. (Available at most local hardware stores)
5
Loading...