Sunpentown WA-1070E Installation Manual

PORTABLE AIR CONDITIONER
WA-8070E: 8,000 BTU
WA-1070E: 10,000 BTU
Read and retain these instructions for future reference
Read this Manual
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You’ll find many answers to common problems in the chart of troubleshooting tips. If you review our hart of Troubleshooting Tips first, you may not need to call for service at all.
CAUTION
Contact the authorized service technician for repair or maintenance of this unit. Contact the installer for installation of this unit. The air conditioner is not intended for use by young children or infirm persons without
supervision.
Young children should be supervised to ensure that they do not play with the air conditioner. If the power cord is to be replaced, replacement work shall be performed by authorized
personnel only.
Installation work must be performed in accordance with the national wiring standards by
authorized personnel only.
CONTENTS
SOCIAL REMARK
Social remark ……………………………………………………………………………………… 2
SPECIFICATIONS
Specifications ………………………………………………………………………………………2 Operating Conditions ………………………………………………………………………………2 SAFETY PRECAUTIONS Safety rules ………………………………………………………………………………………….3 Electrical information ……………………………………………………………………………….3 PARTS IDENTIFICATION Accessories ………………………………………………………………………………………….4 Name of Parts ………………………………………………………………………………………4 AIR CONDITIONER FEATURES Control Panel ……………………………………………………………………………………….5 Operating Instructions ………………………………………………………………………………6 INSTALLATION INSTRUCTIONS Location ……………………………………………………………………………………………..7 Window Kit Installation …………………………………………………………………………….8 Exhaust Hose Installation …………………………………………………………………………9 CARE AND MAINTENANCE Care and Maintenance ……………………………………………………………………………10 TROUBLESHOOTING TIPS Trouble Shooting ………………………………………………………………………………….11 Error Codes ………………………………………………………………………………………..11 Energy Saving Tips ………………………………………………………………………………11 REMOTE CONTROLLER Handling the Remote …………………………………………………………………………….12 Function buttons …………………………………………………………………………………..13 LCD Indicators …………………………………………………………………………………….14 Using the Buttons ……………………………………………………………………………15-17 WARRANTY Your Guarantee ………………………………………………………………………………….18
SOCIAL REMARK
Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
Dispose packaging materials, such as plastic and carton, in the appropriate waste bins.
When this product reaches the end of its useful life, do not dispose with general household waste. For the correct collection and treatment of this product, take them to the collection point for reuse of electrical and electronic equipment. Contact your local authority for the appropriate collection point in your neighborhood.
SPECIFICATIONS
·
Model no. WA-8070E WA-1070E Cooling capacity
8,000 BTU/hr 10,000 BTU/hr
Power consumption EER 8.9 8.9
Air volume (max. speed) 314m3/h 328m3/h Noise level (H/L) 53.2/53.6 Humidity removal capacity 0.9 L/hr 1.1 L/hr Power supply 115V/60Hz/1phase Compressor rotary Recommended room size 150-250 sq.ft. 200-300 sq.ft. Refrigerant R410A Fan speed 2 Timer 0.5 ~ 24 hours Thermostat 62 ~88°F Operating temperature (cool) 62 ~ 95°F Operating temperature (dry) 55 ~ 95°F Exhaust pipe 59 in Net / Gross Weight 50.71 / 58.42 lbs Unit Dimension 13.75 x 15 x 29.50 Package Dimension 15.43 x 21.34 x 30.71
900W 1125W
* Data may vary for technical reasons; for greater precision, please refer to the rating label
located on the back of the unit.
Operating Conditions
The air conditioner must be operated within the temperature range indicated below:
MODE ROOM TEMPERATURE COOL 17 ~ 35°C / 62 ~ 95°F DRY 13 ~ 35°C / 55 ~ 95°F
SAFETY PRECAUTIONS
Safety rules
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. Your air conditioner should be used in such a way that it is protected from moisture, e.g.
condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid. Unplug unit immediately if it occurs.
Always transport your air conditioner in a vertical position and stand on a stable, level
surface during use.
Turn off the product when not in use. Always contact a qualified person to carry out repairs. If the supply cord is damaged, it must
be repaired by a qualified electrician.
Keep a clearance of at least 12 inches around the unit for proper air flow. If the air conditioner is knocked over during use, turnoff the unit and unplug immediately. Turn off and unplug the machine when it will not be used for an extended period of time. Never leave the appliance unsupervised when in operation. Do not store or use gasoline or other flammable vapours and liquids within the vicinity of this
or any other appliance.
Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not
remove any prong from the power cord.
Caution
Do not operate your machine in a wet room such as a bathroom or laundry room. Do not touch the unit with wet or damp hands or when barefoot. Do not press the buttons on the control panel with anything other than your fingers. Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it
has been dropped or damaged.
When unit is not in good order, please use common sense to prevent further damage to
surroundings.
All clean up is operator's responsibility. The manufacturer is not responsible for damages caused by improper use or non-
observance of this instruction manual.
If there is water leakage, clean up must be taken immediately. Never use the plug to start or stop the machine. Do not cover or obstruct the inlet or outlet grilles. Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the
unit in the presence of inflammable substances or vapour such as alcohol, insecticides, petrol, etc.
Do not allow children to operate the unit unsupervised. Do not use this product for functions other than those described in the instruction manual. To prolong the life of the compressor, after powering off the unit, please wait at least 3
minutes before turning it back on.
WARNING! Electrical Information
Be sure the electrical service is adequate for the model you have chosen. This information
can be found on the serial plate, which is located on the side of the cabinet or back of unit.
Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper
grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If the wall
receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
Ensure the receptacle is within accessible range after unit installation.
PARTS IDENTIFICATION
Check all accessories are included in the package. Refer to the installation instructions for usage. Note: all illustrations in this manual are for explanation purposes only. The actual unit and parts may be slightly different. The actual shape shall prevail.
Front
1. Control Panel
2. Horizontal Louver Blade (adjusts manually)
3. Handle (both sides)
4. Remote Signal Receptor
5. Front Housing Panel
Back
6. Upper Air Filter (located behind grille)
7. Air Outlet
8. Caster
9. Air Intake
10. Drain Outlet
11. Air Intake
12. Lower Air Filter (located behind grille)
13. Bottom Tray Drain Outlet
AIR CONDITIONER FEATURES
Before you begin, thoroughly familiarize yourself with the control panel and remote controller and the functions.
The unit can be controlled by either the control panel or remote controller. CONTROL PANEL
1. MODE select button Press to select the operating mode. Each press of the button will cycle through the sequence: AUTO, COOL, DRY and FAN. The corresponding mode indicator will illuminate.
2. SLEEP button Press to initiate the SLEEP operation
3. UP (∧∧∧) and DOWN (∨∨∨∨) buttons
To increase or decrease temperature setting (17-30°C/62-88°F): each press is
increment of 1°C or 2°F.
To set TIMER (0-24 hrs) Press and hold both buttons for 3 seconds to change display from degrees
Fahrenheit to degrees Celsius, or vice versa
4. ON-OFF button Press to turn unit ON or OFF
5. TIMER button Press to initiate the AUTO-ON or AUTO-OFF program.
6. FAN button Press to select HIGH or LOW fan speed. The corresponding speed indicator will illuminate
7. LED display
Shows the set temperature in °C or °F and TIMER set ting If in DRY or FAN mode: shows the ambient temperature
Loading...
+ 13 hidden pages