PORTABLE AIR CONDITIONER WITH HEATER
WA-9061H: 9,000 BTU
WA-1061H: 10,000BTU
☆
Read and retain these instructions for future reference
SPECIFICATION
·
Model no. WA-9061H WA-1061H
Cooling capacity
Heating capacity
EER 9.93 9.35
Power/Ampere consumption – Cooling* 906W / 8.3 A 1070W / 8.7 A
Power/Ampere consumption – Heating* 840W / 7.75 A 950W / 8.18 A
Air volume (max. speed) 375m3/h 375m3/h
Humidity removal capacity
Power supply 115V~, 60Hz/1phase
Compressor rotary
Recommended room size 250 sq.ft. 300 sq.ft.
Refrigerant R410A
Fan speed 2
Timer 1~ 12 hours
Thermostat
Operating temperature 45 ~ 95°F
Exhaust pipe 5 x 59 in
Net Weight 47.4 lbs 55.12 lbs
Dimension 12W x 15D x 29.61H in
9000 BTU/hr
2637 W
8500 BTU/hr
2491 watts
1 L/hr 1 L/hr
Cooling: 64~90°F (18~32°C)
Heating: 45~77°F (7~25°C)
10000 BTU/hr
2930 W
9500 BTU/hr
2783 watts
* Data may vary for technical reasons; for greater precision, please refer to the rating label
located on the back of the unit.
NOTE:
1. Measuring condition for above is:
Cooling: DB= 95°F / WB= 75°F
Heating: DB= 68°F / WB = 59°F
2. Current & Fuse: F2L250V or T2L250V
BEFORE USE
GENERAL SAFETY
• Only use in the upright position on a flat level
surface and at least 14in. from any walls or
objects (fig 1 & 4).
• Do not place any objects on the unit or block the
air inlet / outlet (fig. 2).
• Closely supervise children and pets when unit is
in use.
ELECTRICAL SAFETY
• For indoor household use only.
• Switch off and unplug when not in use.
• Do not use in humid or wet environments. (fig 3)
• Do not pull the UNIT by the cord.
• IF THE SUPPLY CORD IS DAMAGED, TO
AVOID HAZARD, IT MUST BE REPLACED BY
AN ELECTRICIAN OR SIMILARLY QUALIFIED
PERSON.
FOR MAXIMUM EFFICENCY
• Use the unit in the recommended room size.
• Locate the unit where furniture cannot obstruct
the airflow.
FIG.2
FIG.3
• Close doors and windows.
• Keep curtains or blinds closed during the
sunniest part of the day.
• Keep filters clean.
• Set unit to maximum cooling on high initially and
once room has reached the desired conditions,
reduce temperature and fan speed settings.
• It is recommended to turn on the air conditioner
when ambient temperature reaches 75°F. Do
not wait until the room is excessively hot.
FIG.4
PARTS
Front Back
1. Display window
2. Control panel
3. Air outlet
4. Carrying handle
5. Caster
Accessories
FIG.5
6. Cord storage
7. Air filter
8. Air inlet
9. Exhaust air outlet
10. Air inlet
11. Water stopper/drainage
FIG.6
13. Exhaust hose
14. Slider kit adapter – connects exhaust hose
to slider kit.
15. Plastic slider kit – piece 1 of 2
FIG.7
16. Plastic slider kit – piece 2 of 2
17. Drain tube
18. Active carbon filter
19. Remote