Sunpentown IM150US User Manual

1
UNDERCOUNTER ICE MAKER
USER MANUAL
Model #: IM-150US
2
IMPORTANT SAFETY INSTRUCTIONS
~WARNING~
FOLLOW
THESE BASIC PRECAUTIONS
TO
REDUCE
THE RISK OF FIRE,
ELECTRICAL
SHOCK,
OR INJURY WHEN USING YOUR
ICE
MAKER.
· READ ALL INSTRUCTIONS BEFORE USING THE ICE MAKER.
·
DANGER: RISK OF CHILD ENTRAPMENT. CHILD ENTRAPMENT AND SUFFOCATION ARE NOT PROBLEMS OF THE PAST.
JUNKED
OR ABANDONED APPLIANCES ARE STILL DANGEROUS.
·
BEFORE YOU THROW AWAY YOUR ICE MAKER: TAKE OFF THE DOOR.
·
NEVER ALLOW CHILDREN TO OPERATE, PLAY WITH, OR CRAWL INSIDE THE APPLIANCE.
·
NEVER CLEAN ICE MAKER PARTS WITH FLAMMABLE FLUIDS. THE FUMES CAN CREATE A FIRE HAZARD OR EXPLOSION.
·
DO NOT STORE OR USE GASOLINE OR ANY OTHER FLAMMABLE VAPORS AND
LIQUIDS
IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. THE FUMES CAN CREATE A
FIRE
HAZARD OR EXPLOSION.
INSTALLATION INSTRUCTIONS
Ø BEFORE USING YOUR ICE MAKER
· REMOVE THE EXTERIOR AND INTERIOR PACKING.
· VERIFY
THAT YOU HAVE ALL OF THE FOLLOWING PARTS:
· 1
ICE BUCKET
· 1
PLASTIC SCOOP
· 1
HOSE, 25 FT.
· 1
INSTRUCTION MANUAL
· BEFORE
INSTALLING AND USING YOUR NEW ICE MAKER, LET IT STAND UPRIGHT FOR A
MINIMUM OF 4 HOURS. THIS WILL REDUCE THE POSSIBILITY OF A COOLING SYSTEM MALFUNCTION FROM IMPROPER HANDLING DURING TRANSPORTATION.
· CLEAN
THE INTERIOR SURFACE WITH LUKEWARM WATER USING A SOFT CLOTH.
Ø INSTALLATION OF YOUR ICE MAKER
· THIS APPLIANCE IS DESIGNED TO EXHAUST HOT AIR THROUGH THE FRONT VENT. THIS ALLOWS FOR INSTALLATION IN A RECESSED OR BUILT-IN APPLICATION, IF DESIRED.
· PLACE
YOUR ICE MAKER ON A LEVEL SURFACE THAT IS STRONG ENOUGH TO SUPPORT
THE ICE MAKER WHEN IT IS FULLY LOADED. REMEMBER THAT THE UNIT WILL BE SIGNIFICANTLY HEAVIER ONCE IT IS OPERATIONAL AND FULLY LOADED. LEVEL YOUR ICE MAKER BY ADJUSTING THE LEGS AT THE FRONT OF THE ICE MAKER.
· LOCATE
THE ICE MAKER AWAY FROM DIRECT SUNLIGHT AND OTHER HEAT SOURCES
(STOVE, HEATER, RADIATOR, ETC.). DIRECT SUNLIGHT MAY AFFECT THE FINISH.HEAT SOURCES MAY INCREASE ELECTRICAL CONSUMPTION. EXTREMELY COLD AMBIENT TEMPERATURES MAY CAUSE THE ICE MAKER TO MALFUNCTION. THIS ICE MAKER IS DESIGNED FOR INSTALLATION AND USE INDOORS IN CONTROLLED AMBIENT CONDITIONS.
· AVOID
LOCATING THE ICE MAKER IN MOIST/HUMID AREAS. EXCESS MOISTURE IN THE AIR
MAY CAUSE FROST TO FORM QUICKLY ON THE EVAPORATOR AND CABINET, REQUIRING FREQUENT DEFROSTING. THE ICE MAY ALSO STICK TOGETHER
· PLUG
THE ICE MAKER INTO A DEDICATED, PROPERLY INSTALLED GROUNDED WALL
OUTLET. DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER PLUG. ANY QUESTIONS CONCERNING POWER AND/OR GROUNDING SHOULD BE DIRECTED TOWARD A CERTIFIED ELECTRICIAN.
3
Ø ELECTRICAL CONNECTION
· THIS ICE MAKER SHOULD BE PROPERLY GROUNDED FOR YOUR SAFETY. THE POWER CORD OF THIS ICE MAKER IS EQUIPPED WITH A THREE-PRONG PLUG WHICH MATES WITH STANDARD THREE PRONG WALL OUTLETS TO MINIMIZE THE POSSIBILITY OF ELECTRICAL SHOCK.
· DO
NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE THIRD GROUNDING PRONG
FROM THE SUPPLIED POWER CORD.
· DO
NOT USE AN EXTENSION CORD TO CONNECT POWER TO THE UNIT.
· DO
NOT USE A TWO-PRONG GROUNDING ADAPTER.
· IF
YOU ONLY HAVE A TWO-PRONG WALL RECEPTACLE, CONTACT A QUALIFIED
ELECTRICIAN TO HAVE IT REPLACED WITH A GROUNDED 3-PRONG RECEPTACLE IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES.
· THIS
ICE MAKER REQUIRES A STANDARD 115 VOLTS A.C. 60HZ GROUNDED ELECTRICAL
OUTLET WITH THREE-PRONG.
· THE
CORD SHOULD BE SECURED BEHIND THE ICE MAKER AND NOT LEFT EXPOSED OR
LOOSE.
Ø EXTENSION CORD BECAUSE OF POTENTIAL SAFETY HAZARDS, THIS APPLIANCE IS NOT RECOMMENDED FOR USE WITH AN EXTENSION CORD. HOWEVER, IF YOU MUST USE AN EXTENSION CORD, USE ONLY A UL/CUL-LISTED, 3-WIRE GROUNDING TYPE APPLIANCE EXTENSION CORD WITH A GROUNDING TYPE PLUG AND OUTLET. THE ELECTRICAL RATING OF THE CORD MUST BE 115 VOLTS AND AT LEAST 10 AMPS.
Ø CONNECTING THE WATER SUPPLY
· ALL
THE NECESSARY HARDWARE IS NOT PROVIDED (AS THE PLUMBING FIXTURES AT
THE INSTALLATION POINT MAY DIFFER) FOR INSTALLATION SO IT IS NECESSARY TO HIRE A PROFESSIONAL LICENSED PLUMBER TO COMPLETE THE INSTALLATION.
· CONNECT
TUBING (SUPPLIED WITH UNIT) TO THE NEAREST COLD WATER SOURCE. HAVE
SUFFICIENT TUBING TO ALLOW UNIT TO BE MOVED FREELY FOR CLEANING AND SERVICE. ALSO MAKE SURE THAT THE TUBING IS NOT PINCHED OR DAMAGED DURING TRANSPORTATION AND/OR INSTALLATION.
· POSITION
UNIT TO ALLOW AIRFLOW THROUGH THE FRONT GRILL
(SEE FIGURE 1).
· WIPE
THE INSIDE OF UNIT AND ICE BUCKET WITH A DAMP CLOTH.
Ø REVERSING THE DOOR SWING OF YOUR ICE MAKER THIS ICE MAKER IS DESIGNED TO ALLOW THE DOOR TO BE OPENED FROM EITHER THE LEFT OR RIGHT SIDE. THE UNIT IS DELIVERED TO YOU WITH THE DOOR OPENING FROM THE LEFT SIDE (HINGED ON THE RIGHT). PLEASE CONTACT CUSTOMER SERVICE FOR INSTRUCTIONS ON REVERSING THE DOOR SWING.
~WARNING~
IMPROPER USE OF THE GROUNDED PLUG CAN RESULT IN THE RISK OF ELECTRICAL SHOCK. IF THE POWER CORD IS DAMAGED, HAVE IT REPLACED BY AN AUTHORIZED TECHNICIAN.
FIGURE 1
~WARNING~
IMPROPER WATER LINE CONNECTION MAY RESULT IN FLOODING
YOU MUST USE A LICENSED PLUMBER
REVIEW STATE AND LOCAL PLUMBING CODES BEFORE INSTALLATION
Loading...
+ 4 hidden pages