SUNON ME40100V1-000U-G99 Specification

Page 1
2010.08.20
SUNON
SPECIFICATION FOR APPROVAL
CUSTOMER
MOTOR TYPE
DESCRIPTION
DIMENSIONS :
M O D E L
SUNON SPEC. NO.
CUSTOMER APPROVAL NO. APPROVED BY CUSTOMER
(AUTHORIZED)
:
: MagLev Motor Fan
40X40X10 mm
: ME40100V1-000U-G99
D04077420G-00
:
SPEC.NO D04077420G-00
DRAWN
建準電機工業股份有限公司
SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD.
NO. 30, LN. 296, XINYA RD., QIANZHEN DIST., TEL:886-7-8135888
KAOHSIUNG CITY 80673, TAIWAN (R.O.C) FAX:886-7-8230505/8230606/8231010
URL:http://www.sunon.com
Jodi
05/24
CHECKED
Kiddy
APPROVED
建 準 電 機
SUNONWEALTH
Page 1 of 16
Meijung
E-mail: sunon@email.sunon.com.tw
ISSUE DATE 05.24.2010
EDITION 0
REVISION DATE
E.SPEC E10900481
Page 2
2010.08.20
I. MODEL NUMBERING SYSTEM
ME
Series Code
0
Voltage
0: 5VDC 1: 12VDC 2: 24VDC 3: 36VDC
V
1
Speed
X:Super High 1: High 2: Medium 3: Low
-
000U40 10
-
Customer Code
G99
Function Code
編碼 尺寸(mm) 編碼 尺寸(mm) 編碼 尺寸(mm) 編碼 尺寸(mm) 01~09 1~9 A0~A9 100~109 K0~K9 200~209 V0~V9 300~309 10~19 10~19 B0~B9 110~119 L0~L9 210~219 W0~W9 310~319 20~29 20~29 C0~C9 120~129 M0~M9 220~229 X0~X9 320~329 30~39 30~39 D0~D9 130~139 N0~N9 230~239 Y0~Y9 330~339 40~49 40~49 E0~E9 140~149 P0~P9 250~259 Z0~Z9 340~349 50~59 50~59 F0~F9 150~159 Q0~Q9 260~269 60~69 60~69 G0~G9 160~169 R0~R9 270~279 70~79 70~79 H0~H9 170~179 S0~S9 280~289 80~89 80~89 I0~I9 180~189 T0~T9 290~299 90~99 90~99 J0~J9 190~199 U0~U9 290~299
4: 48VDC
Thickness Size
Bearing
V: Vapo B: 2 Ball O: 1Ball S: Sleeve
建 準 電 機
SUNONWEALTH
Page 2 of 16
Page 3
II. SPECIFICATION
2010.08.20
1. MECHANICAL CHARACTERISTIC
MOTOR DESIGN
BEARING SYSTEM
DIMENSIONS
MATERIALS OF FRAME
MATERIALS OF FAN BLADE
DIRECTION OF ROTATION
MOUNTING HOLES
WEIGHT
2 phases, 4-poles Brushless DC motor
Vapo bearing system
See Page 6
Thermoplastic PBT of UL 94V-0
Thermoplastic PBT of UL 94V-0
Counter-clockwise viewed from front of fan blade
Diameter 4.3 mm in 4 holes
13.5 g
2. ELECTRIC CHARACTERISTIC
RATED VOLTAGE
RATED CURRENT
RATED POWER CONSUMPTION
OPERATING VOLTAGE RANGE
STARTING VOLTAGE
OPERATING TEMPERATURE RANGE
STORAGE TEMPERATURE RANGE
5 VDC
215 mA / Max. 248 mA
1.08 WATTS / Max. 1.24 WATTS
3.5~6 VDC
3.5 VDC (25 deg. C POWER ON/OFF)
-10 to + 70 deg. C
-40 to + 70 deg. C
建 準 電 機
SUNONWEALTH
Page 3 of 16
Page 4
3. PERFORMANCE CHARACTERISTIC
2010.08.20
RATED SPEED 7000 RPM ± 15% at rated voltage
AIR FLOW
STATIC PRESSURE 0.19 Inch-H
ACOUSTIC NOISE
AIR FLOW V.S. PRESSURE See Page 5
INSULATION CLASS UL Class A
INSULATION RESISTANCE
PLASTIC HOUSING
DIELECTRIC STRENGTH Applied AC 500V for one minute or AC 600 V for 2
LIFE EXPECTANCY 60,000 Hours at 40 deg. C, 65% humidity, 90% CL.
PROTECTION
8.0 CFM
O
2
32 dB(A)
10M ohm at 500 VDC between internal stator and lead wire (+)
Seconds between housing and lead wire (+)
Automatic Restart
Note: In a situation where the fan is locked by an external force while the electricity is on, an increase in coil temperature will be prevented by temporarily turning off the electrical power to the motor. The fan will automatically restart when the locked rotor condition is released.
Polarity Protection
4. SAFETY
SAFETY UL CUR TUV
NO. E77551 E77551
建 準 電 機
SUNONWEALTH
Page 4 of 16
Page 5
2010.08.20
MODEL :ME40100V1-000U-G99
PERFORMANCE CURVES
STATIC PRESSURE
mm-H2O Inch-H2O
6
4
0.20
5 VDC
2
0
0.10
0 5 10 0 0.141 0.282
建 準 電 機
SUNONWEALTH
Page 5 of 16
CFM
3
m
/min
Page 6
2010.08.20
DIMENSIONS
建 準 電 機
SUNONWEALTH
Page 6 of 16
Page 7
2010.08.20
LABEL
BLACK WORD COLOR :SILVER
BLACK WORD COLOR:PANTONE 347C
GREEN
ME40100V1-000U-G99
DC5V
TUV
Rheinland
Product Saf e ty
1.08W
EP
BLACK WORD COLOR :SILVER
DA TE CODE
建 準 電 機
SUNONWEALTH
Page 7 of 16
Page 8
2010.08.20
T4T3T2 T1
T=1 Rotation
T=T1+T2+T3+T4 =(1 Rotation)
T1=T2=T3=T4=
建 準 電 機
SUNONWEALTH
Page 8 of 16
60
4 rpm
Page 9
FAN 3rd WIRE SIGNAL
2010.08.20
V
H
V
L
t3t3t3t
I
R
Run
3
S
I
t
1
t
2
t
2
Locked
3rd wire signal Run : Square Wave Locked : V
H
or
V
L
t3: F Type has open collector circuit designed for RPM measurement
Vcc
1/4
t
1
Vce(sat)
DC FAN
Run
(+) 3
rd
(-)
R
L
Locked
建 準 電 機
SUNONWEALTH
Page 9 of 16
Ic
Vcc
Vcc=VCC(Max) Ic=4mA(Max) R
L
Vcc/Ic
Page 10
III. OTHER SPECIFIED TESTING
2010.08.20
The following is a general description of certain tests that are performed on representative Sunon fans. Nothing in this document is intended to suggest that these tests are performed on every model of Sunon fan. Moreover, the descriptions that follow each test are meant only to provide a general explanation of each test. If you would like a more detailed explanation as to any test identified in this Section, Sunon can provide such an explanation upon request.
1. DROP PROOF TEST
Fans are packaged in a standard size shipping box and are dropped to the ground from
certain heights and angles depending on the weight of the particular box.
2. HUMIDITY PROOF TEST
The fan is operated for 96 continuous hours in an environment with humidity of 90% to
95% RH at 60°C 2°C.
3. VIBRATION PROOF TEST
Vibration with an amplitude 2mm and a frequency of 5-55-5hz is applied in all 3
directions (X,Y,Z), in cycles of 1 hour each, for a total vibration time of 3hours.
4. THERMAL CYCLING TEST
The fan is operated in a testing chamber for 50 cycles. In each cycle, the temperature is
gradually increased from -10°C to 70°C for 90 minutes, and subsequently operated at
70°C for 120 minutes. The temperature is then gradually decreased from 70°C to -10°C
for 90 minutes, and subsequently operated at -10°C for 120 minutes.
5. SHOCK PROOF TEST
100G of force is applied in the 3 directions (X,Y, and Z) for 2 milliseconds each.
6. LIFE EXPECTANCY The “Life Expectancy” of SUNON fans is determined in SUNON’s reliability test laboratory by using temperature chambers. The “Life Expectancy” of this fan has not been evaluated for use in combination with any end application. Therefore, the Life Expectancy Test Reports (L10 and MTTF Report) that relate to this fan are only for reference.
建 準 電 機
SUNONWEALTH
Page 10 of 16
Page 11
IV. CHARACTERISTIC DEFINITION
2010.08.20
The following is a general description of certain tests that are performed on representative Sunon fans in order to determine the specifications of the fan. Nothing in this document is intended to suggest that these tests are performed on every model of Sunon fan. Moreover, the descriptions that follow each test are meant only to provide a general explanation of each test. If you would like a more detailed explanation as to any test identified in this Section, Sunon can provide such an explanation upon request.
1. ACOUSTICAL NOISE
Measured in a semi-anechoic chamber with background noise level below 15dB(A).
1 METER FROM MICROPHONE TO FAN INTAKE
The fan is running in free air under shaft horizontal condition with the microphone at distance of one meter from the fan intake.
2. INPUT POWER
Measured after continuous 10 minute operation at rated voltage in clean air ( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft horizontal condition.
3. RATED CURRENT
Measured after continuous 10 minute operation at rated voltage in clean air ( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft horizontal condition.
建 準 電 機
SUNONWEALTH
Page 11 of 16
Page 12
4. RATED SPEED
2010.08.20
Measured after continuous 10 minute operation at rated voltage in clean air ( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft horizontal condition.
5. STARTING VOLTAGE
Measured the voltage which enables to start the fan in the clean air (static pressure = 0 ) by switching on at the voltage under shaft horizontal condition. It is not at continuously increasing voltage adjustment.
6. LOCKED ROTOR CURRENT
Measured immediately after the fan blade is locked.
7. AIR FLOW AND STATIC PRESSURE
The performance specification of air flow and static pressure shown in this specification for approval is measured using the exhaust method. A double chamber is used in accordance with AMCA 210 standard or DIN 24163 specification . The values are recorded when the fan speed has stabilized at rated voltage.
8. INSULATION RESISTANCE
1. PLASTIC HOUSING: (1) Measured between internal stator and lead wire(+). (2) Measured between housing and lead wire(+).
2. ALUMINIUM HOUSING: Measured between internal stator and lead wire(+).
9. DIELECTRIC STRENGTH
Measure between housing and lead wire(+).
建 準 電 機
SUNONWEALTH
Page 12 of 16
Page 13
V. NOTE
2010.08.20
.SAFETY
1. DO NOT use or operate this fan in excess of the limitations set forth in this specification. SUNON is not be responsible for the non-performance of this fan and/or any damages resulting from its use, if it is not used or operated in accordance with the specifications.
2. SUNON recommends adding a protection circuit to the product or application in which this fan is installed, such as a thermo-fuse, or current-fuse or thermo-protector. The failure to use such a device may result in smoke, fire, electric shock by insulation degradation in cases of motor lead short circuit, overload, or over voltage, and/or other failure.
3. SUNON recommends installing a protection device to the product or application in which this fan is installed if there is a possibility of reverse-connection between VDC (+) and GND (-). The failure to install such a device may result in smoke, fire, and/or destruction, although these conditions may not manifest immediately.
4. This fan must be installed and used in compliance with all applicable safety standards and regulations.
5. Use proper care when handling and/or installing this fan. Improper handling or installation of this fan may cause damage that could result in unsafe conditions.
6. Use proper care during installation and/or wiring. Failure to use proper care may cause damage to certain components of the fan including, but not limited to, the coil and lead wires, which could result in smoke and/or fire.
7. DO NOT use power or ground PWM to control the fan speed. If the fan speed needs to be adjusted, please contact Sunon to customize the product design for your application.
8. For critical or extreme environments, including non stop operation, please contact Sunon and we will gladly provide assistance with your product selection to ensure an appropriate cooling product for your application.
建 準 電 機
SUNONWEALTH
Page 13 of 16
Page 14
II. SPECIFICATION MODIFICATION
2010.08.20
1. SUNON offers engineering assistance on fan installation and cooling system design.
2. All changes, modifications and/or revisions to the specifications, if any, are incorporated in the attached specifications.
3. No changes, modifications and/or revisions to these specifications are effective absent agreement, by both Sunon and the customer, in writing.
4. This fan will be shipped in accordance with the attached specification unless SUNON and the customer have agreed otherwise, in writing, as specficied in Paragraph 3, above.
III. OTHER
1. When building your device, please examine thoroughly any variation of EMC, temperature rise, life data, quality, etc. of this product by shock/drop/vibration testing, etc. If there are any problems or accidents in connection with this product, it should be mutually discussed and examined.
2. Use proper care when handling this fan. Components such as fan holders or bearings may be damaged, if touched with fingers or other objects. Additionally, static electricity (ESD) may damage the internal circuits of the fan.
3. DO NOT operate this fan in proximity to hazardous materials such as cyanogens, formalin, phenol, or corrosive gas environments including, but not limited to, H2S, SO2, NO2, or Cl2.
4. SUNON recommends that you protect this fan from exposure to outside elements such as dust, condensation, humidity or insects. Exposure of this fan to outside
organic silicon,
elements such as dust, condensation, humidity or insects may affect its performance and may cause safety hazards. SUNON does not warrant against damage to the product caused by outside elements.
5. This fan must be installed properly and securely. Improper mounting may cause harsh resonance, vibration, and noise.
建 準 電 機
SUNONWEALTH
Page 14 of 16
Page 15
6. Fan guards may prevent injury during handling or installation of the fan and are
2010.08.20
available for sale with this fan.
7. Unless otherwise noted, all testing of this fan is conducted at 25°C ambient temperature and sixty-five percent (65%) relative humidity.
8. DO NOT store this fan in an environment with high humidity. This fan must be stored in accordance with the attached specifications regarding storage temperature. If this fan is stored for more than 6 months, SUNON recommends functional testing before using.
9. SUNON reserves the right to use components from multiple sources at its discretion. The use of components from other sources will not affect the specfications as described herein.
10. The “Life Expectancy” of this fan has not been evaluated for use in combination with any end application. Therefore, the Life Expectancy Test Reports (L10 and MTTF Report) that relate to this fan are only for reference.
VI. WARRANTY
This fan is warranted against all defects which are proved to be fault in our workmanship and material for one year from the date of our delivery. The sole responsibility under the warranty shall be limited to the repair of the fan or the replacement thereof, at SUNON’s sole discretion. SUNON will not be responsible for the failures of its fans due to improper handing, misuse or the failure to follow specifications or instructions for use. In the event of warranty claim, the customer shall immediately notify SUNON for verification. SUNON will not be responsible for any consequential damage to the customer’s equipment as a result of any fans proven to be defective.
建 準 電 機
SUNONWEALTH
Page 15 of 16
Page 16
2010.08.20
Declaration of RoHS
Control declaration of environment-related substances/materials
1. In accordance with the Restriction of Hazardous Substances (RoHS) Directive,
Sunon product have complied with law and discipline not to employ the forbidden substances, and restrict the allowable concentration of some limited substances deliberately in our components.
No Substance Criteria
1
CFCs & HCFCs (ozone depleting substances) Forbidden
2
Chlorinated Organic Solvent Forbidden
Plastic (Frame, Impeller, wire harness, etc.) <100ppm
Solder <1000ppm
3
Lead and its compounds
Steel alloy <3500ppm
Aluminium alloy <4000ppm
Copper alloy <4wt%
Solder <20ppm
4
Cadmium and its compounds
5
PBBs and PBDEs Forbidden
6
PCB and PCT Forbidden
7
CP, Short-chain Chlorinated paraffins C10-13, Cl 48 wt% Forbidden
8
Mirex Forbidden
9
PCN Forbidden
10
Hexavalent Chromium compounds <100ppm
11
Mercury and its compounds Forbidden
12
Asbestos Forbidden
13
Organic Tin compounds Forbidden
14
Azo compounds Forbidden
15
TBBP-A in external case plastic parts of products (PCB is exempted) <1000ppm
16
Nickel in external case parts, which are likely to result in prolonged skin exposure <1000ppm
Parts composed of metals containing zinc
<100ppm
(e.g. brass, zinc for die casting)
Plastic <5ppm
建 準 電 機
SUNONWEALTH
Page 16 of 16
Loading...