SUNON HA30101V3-000U-A99 Specification

Page 1
建 準 電 機
CUSTOMER APPROVAL NO.
APPROVED BY CUSTOMER
SPEC.NO
D03033640G-01
ISSUE DATE
07.19.2017
EDITION
0
E.SPEC
E11600150
建準電機工業股份有限公司
SUNON NO. 30, LN. 296, XINYA RD., QIANZHEN DIST., TEL:886 KAOHSIUNG CITY 80673, TAIWAN (R.O.C) URL:http://www.SUNON.com E-mail: sunon@email.sunon.com.tw
2017.09.05
D.C.C.
SUNON
SPECIFICATION FOR APPROVAL
CUSTOMER
MOTOR TYPE
DESCRIPTION DIMENSIONS M O D E L SUNON SPEC. NO.
(AUTHORIZED)
:
: MagLev Motor Fan
30X30X10 mm
: : HA30101V3-1000U-A99 : D03033640G-01 :
:
DRAWN
Nancy 07/19
WEALTH ELECTRIC MACHINE INDUSTRY CO., LTD.
CHECKED
Cindy
APPROVED
SUNONWEALTH
Page 1 of 14
Smart
REVISION DATE
-7-8135888
FAX:886-7-8230505/8230606/8231010
Page 2
建 準 電 機
I. MODEL NUMBERING SYSTEM
編碼
尺寸(mm)
編碼
尺寸(mm)
編碼
尺寸(mm)
編碼
尺寸(mm)
01~09 01~09 A0~A9 100~109 K0~K9 200~209 V0~V9 300~309 10~19 10~19 B0~B9 110~119 L0~L9 210~219 W0~W9 310~319 20~29 20~29 C0~C9 120~129 M0~M9 220~229 X0~X9 320~329 30~39 30~39 D0~D9 130~139 N0~N9 230~239 Y0~Y9 330~339 40~49 40~49 E0~E9 140~149 P0~P9 240~249 Z0~Z9 340~349 50~59 50~59 F0~F9 150~159 Q0~Q9 250~259 60~69 60~69 G0~G9 160~169 R0~R9 260~269 70~79 70~79 H0~H9 170~179 S0~S9 270~279 80~89 80~89 I0~I9 180~189 T0~T9 280~289 90~99 90~99 J0~J9 190~199 U0~U9 290~299
1
0: 5VDC 1: 12VDC 2: 24VDC 3: 36VDC 4: 4
A99
Customer Code
Thickness Size
-
Series Code
V
Bearing
3
Speed
1000U
30
10
-
HA
Function Code
2017.09.05
D.C.C.
Voltage
8VDC
X: Super High 1: High 2: Medium 3: Low 4: Extra Low
V: Vapo B: 2 Ball O: 1Ball S: Sleeve
SUNONWEALTH
Page 2 of 14
Page 3
建 準 電 機
II. SPECIFICATION
2017.09.05
D.C.C.
1. MECHANICAL CHARACTERISTIC
MOTOR DESIGN Single phase, 4-poles Brushless DC motor
BEARING SYSTEM Precise Vapo bearing system
DIMENSIONS See Page 6
MATERIALS OF FRAME Thermoplastic PBT of UL 94V-0
MATERIALS OF FAN BLADE Thermoplastic PBT of UL 94V-0
DIRECTION OF ROTATION Counter-clockwise viewed from front of fan blade
MOUNTING HOLES Diameter 3.2 mm in 3 holes
WEIGHT 7.8 g
2. ELECTRIC CHARACTERISTIC
RATED VOLTAGE 12 VDC
RATED CURRENT 25 mA / Max. 30 mA
RATED POWER CONSUMPTION 0.30 WATTS / Max. 0.36 WATTS
SAFETY POWER CONSUMPTION 0.56 WATTS
OPERATING VOLTAGE RANGE 6~13.8 VDC
STARTING VOLTAGE 6 VDC (25 deg. C POWER ON/OFF)
OPERATING TEMPERATURE RANGE -10 to + 70 deg. C
STORAGE TEMPERATURE RANGE -40 to + 70 deg. C
SUNONWEALTH
Page 3 of 14
Page 4
建 準 電 機
3. PERFORMANCE CHARACTERISTIC
Automatic Restart
restart when the locked rotor condition is released.
 
2017.09.05
D.C.C.
RATED SPEED 7000 RPM ± 20% at rated voltage AIR FLOW 3.5 CFM STATIC PRESSURE 0.10 Inch-H2O ACOUSTIC NOISE 15.1 dB(A) AIR FLOW V.S. PRESSURE See Page 5
INSULATION CLASS UL Class A
INSULATION RESISTANCE
PLASTIC HOUSING
DIELECTRIC STRENGTH Applied AC 500 V for one minute or AC 600 V for 2
LIFE EXPECTANCY 70,000 Hours at 40 deg. C, 65% humidity, 90% CL.
PROTECTION
10M ohm at 500 VDC between internal stator and Lead wire (+)
Seconds between housing and lead wire (+)
Note: In a situation where the fan is locked by an external force while the electricity is on, an increase in coil temperature will be prevented by temporarily turning off the electrical power to the motor. The fan will automatically
Polarity Protection
4. SAFETY
SAFETY UL CUR TUV CE
NO. E77551 E77551
SUNONWEALTH
Page 4 of 14
Page 5
建 準 電 機
MODEL : HA30101V3-1000U-A99
0
0.02
0.04
0.06
0.08
0.1
0 1 2 3 4
Air Flow-CFM
Stati c Pressur e ( I nch-H2O )
0
0.5
1
1.5
2
2.5
0 0.028 0.056 0.084 0.112
m
3
/min
mm-H2O
2017.09.05
D.C.C.
PERFORMANCE CURVES
SUNONWEALTH
Page 5 of 14
Page 6
建 準 電 機
DIMENSIONS
UNITmm
2017.09.05
D.C.C.
Screw Type
(Pan head)
Machine screw
Note: SUNO N recommends the screw a nd torque a s above. Please co ntact SUNON, if any
new requirement is requested.
Torque
1
2 Kgf-cm
Size Standard
M2.5 JIS B1111-1974
Screw Spec
SUNONWEALTH
Page 6 of 14
Page 7
建 準 電 機
LABEL
2017.09.05
D.C.C.
SUNONWEALTH
Page 7 of 14
Page 8
建 準 電 機
III. OTHER SPECIFIED TESTING
2017.09.05
D.C.C.
The following is a general description of certain tests that are performed on representative SUNON fans. Nothing in this document is intended to suggest that these tests are performed on every model of SUNON fan. Moreover, the descriptions that follow each test are meant only to provide a general explanation of each test. If you would like a more detailed explanation as to any test identified in this Section, SUNON can provide such an explanation upon request.
1. DROP PROOF TEST
Fans are packaged in a standard size shipping box and are dropped to the ground from certain heights and angles depending on the weight of the particular box.
2. HUMIDITY PROOF TEST
The fan is operated for 96 continuous hours in an environment with humidity of 90% to 95% RH at 60°C ± 2°C.
3. VIBRATION PROOF TEST
Vibration with an amplitude 2mm and a frequency of 5-55-5hz is applied in all 3 directions (X,Y,Z), in cycles of 1 hour each, for a total vibration time of 3hours.
4. THERMAL CYCLING TEST
The fan is operated in a testing chamber for 50 cycles. In each cycle, the temperature is gradually increased from -10°C to 70°C for 90 minutes, and subsequently operated at 70°C for 120 minutes. The temperature is then gradually decreased from 70°C to -10°C for 90 minutes, and subsequently operated at -10°C for 120 minutes.
5. SHOCK PROOF TEST
100G of force is applied in the 3 directions (X,Y, and Z) for 2 milliseconds each.
6. LIFE EXPECTANCY
The “Life Expectancy” of SUNON fans is determined in SUNON’s reliability test laboratory by using temperature chambers. The “Life Expectancy” of this fan has not been evaluated for use in combination with any end application. Therefore, the Life Expectancy Test Reports (L10 and MTTF Report) that relate to this fan are only for reference.
SUNONWEALTH
Page 8 of 14
Page 9
建 準 電 機
IV. CHARACTERISTIC DEFINITION
2017.09.05
D.C.C.
The following is a general description of certain tests that are performed on representative SUNON fans in order to determine the specifications of the fan. Nothing in this document is intended to suggest that these tests are performed on every model of SUNON fan. Moreover, the descriptions that follow each test are meant only to provide a general explanation of each test. If you would like a more detailed explanation as to any test identified in this Section, SUNON can provide such an explanation upon request.
1. ACOUSTICAL NOISE
Measured in a semi-anechoic chamber with background noise level below 15dB(A).
1 METER FROM MICROPHONE TO FAN INTAKE
The fan is running in free air under shaft horizontal condition with the microphone at distance of one meter from the fan intake.
2. INPUT POWER
Measured after continuous 10 minute operation at rated voltage in clean air ( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft horizontal condition.
3. RATED CURRENT
Measured after continuous 10 minute operation at rated voltage in clean air ( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft horizontal condition.
SUNONWEALTH
Page 9 of 14
Page 10
建 準 電 機
4. RATED SPEED
2017.09.05
D.C.C.
Measured after continuous 10 minute operation at rated voltage in clean air ( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft horizontal condition.
5. STARTING VOLTAGE
Measured the voltage which enables to start the fan in the clean air (static pressure = 0 ) by switching on at the voltage under shaft horizontal condition. It is not at continuously increasing voltage adjustment.
6. LOCKED ROTOR CURRENT
Measured immediately after the fan blade is locked.
7. AIR FLOW AND STATIC PRESSURE
The performance specification of air flow and static pressure shown in this specification for approval is measured using the exhaust method. A double chamber is used in accordance with AMCA 210 standard or DIN 24163 specification . The values are recorded when the fan speed has stabilized at rated voltage.
8. INSULATION RESISTANCE
1. PLASTIC HOUSING: (1) Measured between internal stator and lead wire(+). (2) Measured between housing and lead wire(+).
2. ALUMINIUM HOUSING: Measured between internal stator and lead wire(+).
9. DIELECTRIC STRENGTH
Measure between housing and lead wire(+).
SUNONWEALTH
Page 10 of 14
Page 11
建 準 電 機
V. NOTE
2017.09.05
D.C.C.
.SAFETY
1. DO NOT use or operate this fan in excess of the limitations set forth in this specification. SUNON is not responsible for the non-performance of this fan and/or any damages resulting from its use, if it is not used or operated in accordance with the specifications.
2. SUNON recommends adding a protection circuit to the product or application in which this fan is installed, such as a thermo-fuse, or current-fuse or thermo-protector. The failure to use such a device may result in smoke, fire, electric shock by insulation degradation in cases of motor lead short circuit, overload, or over voltage, and/or other failure.
3. SUNON recommends installing a protection device to the product or application in which this fan is installed if there is a possibility of reverse-connection between VDC (+) and GND (-). The failure to install such a device may result in smoke, fire, and/or destruction, although these conditions may not manifest immediately.
4. This fan must be installed and used in compliance with all applicable safety standards and regulations.
5. Use proper care when handling and/or installing this fan. Improper handling or installation of this fan may cause damage that could result in unsafe conditions.
6. Use proper care during installation and/or wiring. Failure to use proper care may cause damage to certain components of the fan including, but not limited to, the coil and lead wires, which could result in smoke and/or fire.
7. DO NOT use power or ground PWM to control the fan speed. If the fan speed needs to be adjusted, please contact SUNON to customize the product design for your application.
8. For critical or extreme environments, including non stop operation, please contact SUNON and we will gladly provide assistance with your product selection to ensure an appropriate cooling product for your application.
SUNONWEALTH
Page 11 of 14
Page 12
建 準 電 機
II. SPECIFICATION MODIFICATION
2017.09.05
D.C.C.
1. SUNON offers engineering assistance on fan installation and cooling system design.
2. All changes, modifications and/or revisions to the specifications, if any, are incorporated in the attached specifications.
3. No changes, modifications and/or revisions to these specifications are effective absent agreement, by both SUNON and the customer, in writing.
4. This fan will be shipped in accordance with the attached specification unless SUNON and the customer have agreed otherwise, in writing, as specified in Paragraph 3, above.
III. OTHER
1. When building your device, please examine thoroughly any variation of EMC, temperature rise, life data, quality, etc. of this product by shock/drop/vibration testing, etc. If there are any problems or accidents in connection with this product, it should be mutually discussed and examined.
2. Use proper care when handling this fan. Components such as fan holders or bearings may be damaged, if touched with fingers or other objects. Additionally, static electricity (ESD) may damage the internal circuits of the fan.
3. DO NOT operate this fan in proximity to hazardous materials such as cyanogens, formalin, phenol, or corrosive gas environments including, but not limited to, H2S, SO2, NO2, or Cl2.
4. SUNON recommends that you protect this fan from exposure to outside elements such as dust, condensation, humidity or insects. Exposure of this fan to outside
organic silicon,
elements such as dust, condensation, humidity or insects may affect its performance and may cause safety hazards. SUNON does not warrant against damage to the product caused by outside elements.
5. This fan must be installed properly and securely. Improper mounting may cause harsh resonance, vibration, and noise.
SUNONWEALTH
Page 12 of 14
Page 13
建 準 電 機
6. Fan guards may prevent injury during handling or installation of the fan and are
2017.09.05
D.C.C.
available for sale with this fan.
7. Unless otherwise noted, all testing of this fan is conducted at 25°C ambient temperature and sixty-five percent (65%) relative humidity.
8. DO NOT store this fan in an environment with high humidity. This fan must be stored in accordance with the attached specifications regarding storage temperature. If this fan is stored for more than 6 months, SUNON recommends functional testing before using.
9. SUNON reserves the right to use components from multiple sources at its discretion. The use of components from other sources will not affect the specifications as described herein.
10. The “Life Expectancy” of this fan has not been evaluated for use in combination with any end application. Therefore, the Life Expectancy Test Reports (L10 and MTTF Report) that relate to this fan are only for reference.

VI. WARRANTY

This fan is warranted against all defects which are proved to be fault in our workmanship and material for one year from the date of our delivery. The sole responsibility under the warranty shall be limited to the repair of the fan or the replacement thereof, at SUNON’s sole discretion. SUNON will not be responsible for the failures of its fans due to improper handing, misuse or the failure to follow specifications or instructions for use. In the event of warranty claim, the customer shall immediately notify SUNON for verification. SUNON will not be responsible for any consequential damage to the customer’s equipment as a result of any fans proven to be defective.
SUNONWEALTH
Page 13 of 14
Page 14
建 準 電 機
complied with law and disciplin e not to employ
substances deliberat ely in our components.
No
Substance
Criteria
1
CFCs & HCFCs (ozone depleting substances)
Forbidden
2
Chlorinated Organic Solvent
Forbidden
Plastic (Frame, Impeller, wire harness, etc.)
<100ppm
Solder
<1000ppm
Steel alloy
<3500ppm
Aluminium alloy
<4000ppm
Copper alloy
<4wt%
Solder
<20ppm
Plastic
<5ppm
5
PBBs and PBDEs
Forbidden
6
PCB and PCT
Forbidden
7
CP, Short-chain Chlorinated paraffins C10-13, Cl ≥48 wt%
Forbidden
8
Mirex
Forbidden
9
PCN
Forbidden
10
Hexavalent Chromium compounds
<100ppm
11
Mercury and its compounds
Forbidden
12
Asbestos
Forbidden
13
Organic Tin compounds
Forbidden
14
Azo compounds
Forbidden
15
TBBP-A in external case plastic parts of products (PCB is exempted)
<1000ppm
16
Nickel in external case parts, which are likely to result in prolonged skin exposure
<1000ppm
17
Hexabromocyclododecane (HBCDD)
<1000ppm
18
Di-butyl Phthalate (DBP)
<1000ppm
19
Benzyl butyl Phthalate (BBP)
<1000ppm
20
Di-ethylhexyl Phthalate (DEHP)
<1000ppm
21
Di-isobutyl Phthalate (DIBP)
<1000ppm
Declaration of RoHS
2017.09.05
D.C.C.
Control declaration of environment-related substances/materials
1. In accordance with the Restriction of Hazardou s Substances (RoHS) D irective
2011/65/EU, SUNON product have the forbidden substances, and restrict the allowable concentration of some limited
3 Lead and its compounds
4 Cadmium and its compounds
Parts composed of metals containing zinc (e.g. brass, zinc for die casting)
<100ppm