LIFE EXPECTANCY 70,000 Hours at 40 deg. C, 65% humidity, 90% CL.
PROTECTION
10M ohm at 500 VDC between internal stator and
lead wire (+)
Applied AC 500 V for one minute or AC 600 V for 2
Seconds between housing and lead wire (+)
Automatic Restart
Note: In a situation where the fan is locked by an external force
while the electricity is on, an increase in coil temperature will be
prevented by temporarily turning off the electrical power to the
motor. The fan will automatically restart when the locked rotor
condition is released.
Polarity Protection
IP Class : IP68
According to IEC 529 (or IEC 34-5) IP standard, the average
temperature is 23~24°C and humidity is 67% RH for Dust Water Test.
The fan needs to be test and Spray Put in dust box for 8 hours for Dust
Test and be put in long period immersion of water for Spray Water
Test. After these 2 tests, which executing by regular standard, the fan
will be measured the performance is normal or not.
PS. There are different applicative environments and systems by
different customers, so please put the product in the most suitable
environment to measure the performances.
4. SAFETY
SAFETY UL CUR TUV CE
NO. E77551 E77551
建 準 電 機
SUNONWEALTH
Page 4 of 14
2014.06.12
D.C.C.
MODEL : GE80254B1-000U-AE9
PERFORMANCE CURVES
O)
2
Static Pressure (Inch-H
00.340.681.021.361.7
0.5
0.4
0.3
0.2
0.1
m3/min
12.5
10
7.5
5
2.5
O
2
mm-H
0
0 102030405060
Air Flow-CFM
建 準 電 機
SUNONWEALTH
Page 5 of 14
0
2014.06.12
D.C.C.
DIMENSIONS
(Pan head)
Machine screw
Self-tapping screw
Note: SUNON recommends the screw and torque as above. Please contact SUNON, if any
new requirement is requested.
Torque
3~4 Kgf-cm
5~6 Kgf-cm ∮5.0
Screw Spec Screw Type
Size Standard
M4.0 JIS B1111-1974
JIS B1122 Type 2
UNIT:mm
建 準 電 機
SUNONWEALTH
Page 6 of 14
2014.06.12
D.C.C.
LABEL
建 準 電 機
SUNONWEALTH
Page 7 of 14
2014.06.12
D.C.C.
III. OTHER SPECIFIED TESTING
The following is a general description of certain tests that are performed on
representative SUNON fans. Nothing in this document is intended to suggest that
these tests are performed on every model of SUNON fan. Moreover, the descriptions
that follow each test are meant only to provide a general explanation of each test. If
you would like a more detailed explanation as to any test identified in this Section,
SUNON can provide such an explanation upon request.
1. DROP PROOF TEST
Fans are packaged in a standard size shipping box and are dropped to the ground from
certain heights and angles depending on the weight of the particular box.
2. HUMIDITY PROOF TEST
The fan is operated for 96 continuous hours in an environment with humidity of 90%
to 95% RH at 60°C 2°C.
3. VIBRATION PROOF TEST
Vibration with an amplitude 2mm and a frequency of 5-55-5hz is applied in all 3
directions (X,Y,Z), in cycles of 1 hour each, for a total vibration time of 3hours.
4. THERMAL CYCLING TEST
The fan is operated in a testing chamber for 50 cycles. In each cycle, the temperature is
gradually increased from -10°C to 70°C for 90 minutes, and subsequently operated at
70°C for 120 minutes. The temperature is then gradually decreased from 70°C to
-10°C for 90 minutes, and subsequently operated at -10°C for 120 minutes.
5. SHOCK PROOF TEST
100G of force is applied in the 3 directions (X,Y, and Z) for 2 milliseconds each.
6.LIFE EXPECTANCY
The “Life Expectancy” of SUNON fans is determined in SUNON’s reliability test
laboratory by using temperature chambers. The “Life Expectancy” of this fan has not
been evaluated for use in combination with any end application. Therefore, the Life
Expectancy Test Reports (L10 and MTTF Report) that relate to this fan are only for
reference.
建 準 電 機
SUNONWEALTH
Page 8 of 14
IV. CHARACTERISTIC DEFINITION
2014.06.12
D.C.C.
The following is a general description of certain tests that are performed on
representative SUNON fans in order to determine the specifications of the fan.
Nothing in this document is intended to suggest that these tests are performed on
every model of SUNON fan. Moreover, the descriptions that follow each test are
meant only to provide a general explanation of each test. If you would like a more
detailed explanation as to any test identified in this Section, SUNON can provide
such an explanation upon request.
1. ACOUSTICAL NOISE
Measured in a semi-anechoic chamber with background noise level below 15dB(A).
1 METER FROM MICROPHONE TO FAN INTAKE
The fan is running in free air under shaft horizontal condition with the microphone at
distance of one meter from the fan intake.
2. INPUT POWER
Measured after continuous 10 minute operation at rated voltage in clean air
( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft
horizontal condition.
3. RATED CURRENT
Measured after continuous 10 minute operation at rated voltage in clean air
( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft
horizontal condition.
建 準 電 機
SUNONWEALTH
Page 9 of 14
4. RATED SPEED
2014.06.12
D.C.C.
Measured after continuous 10 minute operation at rated voltage in clean air
( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft
horizontal condition.
5. STARTING VOLTAGE
Measured the voltage which enables to start the fan in the clean air (static pressure = 0 )
by switching on at the voltage under shaft horizontal condition. It is not at continuously
increasing voltage adjustment.
6. LOCKED ROTOR CURRENT
Measured immediately after the fan blade is locked.
7. AIR FLOW AND STATIC PRESSURE
The performance specification of air flow and static pressure shown in this specification
for approval is measured using the exhaust method. A double chamber is used in
accordance with AMCA 210 standard or DIN 24163 specification . The values are
recorded when the fan speed has stabilized at rated voltage.
8. INSULATION RESISTANCE
1. PLASTIC HOUSING:
(1) Measured between internal stator and lead wire(+).
(2) Measured between housing and lead wire(+).
2. ALUMINIUM HOUSING:
Measured between internal stator and lead wire(+).
9. DIELECTRIC STRENGTH
Measure between housing and lead wire(+).
建 準 電 機
SUNONWEALTH
Page 10 of 14
V. NOTE
2014.06.12
D.C.C.
Ⅰ
.SAFETY
1. DO NOT use or operate this fan in excess of the limitations set forth in this
specification. SUNON is not responsible for the non-performance of this fan
and/or any damages resulting from its use, if it is not used or operated in
accordance with the specifications.
2. SUNON recommends adding a protection circuit to the product or application in
which this fan is installed, such as a thermo-fuse, or current-fuse or
thermo-protector. The failure to use such a device may result in smoke, fire,
electric shock by insulation degradation in cases of motor lead short circuit,
overload, or over voltage, and/or other failure.
3. SUNON recommends installing a protection device to the product or application
in which this fan is installed if there is a possibility of reverse-connection
between VDC (+) and GND (-). The failure to install such a device may result in
smoke, fire, and/or destruction, although these conditions may not manifest
immediately.
4. This fan must be installed and used in compliance with all applicable safety
standards and regulations.
5. Use proper care when handling and/or installing this fan. Improper handling or
installation of this fan may cause damage that could result in unsafe conditions.
6. Use proper care during installation and/or wiring. Failure to use proper care may
cause damage to certain components of the fan including, but not limited to, the
coil and lead wires, which could result in smoke and/or fire.
7. DO NOT use power or ground PWM to control the fan speed. If the fan speed
needs to be adjusted, please contact SUNON to customize the product design for
your application.
8. For critical or extreme environments, including non stop operation, please contact
SUNON and we will gladly provide assistance with your product selection to
ensure an appropriate cooling product for your application.
建 準 電 機
SUNONWEALTH
Page 11 of 14
2014.06.12
D.C.C.
II. SPECIFICATION MODIFICATION
1. SUNON offers engineering assistance on fan installation and cooling system design.
2. All changes, modifications and/or revisions to the specifications, if any, are
incorporated in the attached specifications.
3. No changes, modifications and/or revisions to these specifications are effective
absent agreement, by both SUNON and the customer, in writing.
4. This fan will be shipped in accordance with the attached specification unless
SUNON and the customer have agreed otherwise, in writing, as specified in
Paragraph 3, above.
III. OTHER
1. When building your device, please examine thoroughly any variation of EMC,
temperature rise, life data, quality, etc. of this product by shock/drop/vibration
testing, etc. If there are any problems or accidents in connection with this product,
it should be mutually discussed and examined.
2. Use proper care when handling this fan. Components such as fan holders or
bearings may be damaged, if touched with fingers or other objects. Additionally,
static electricity (ESD) may damage the internal circuits of the fan.
3. DO NOT operate this fan in proximity to hazardous materials such as organic
silicon, cyanogens, formalin, phenol, or corrosive gas environments including,
but not limited to, H2S, SO2, NO2, or Cl2.
4. SUNON recommends that you protect this fan from exposure to outside elements
such as dust, condensation, humidity or insects. Exposure of this fan to outside
elements such as dust, condensation, humidity or insects may affect its
performance and may cause safety hazards. SUNON does not warrant against
damage to the product caused by outside elements.
5. This fan must be installed properly and securely. Improper mounting may cause
harsh resonance, vibration, and noise.
建 準 電 機
SUNONWEALTH
Page 12 of 14
6. Fan guards may prevent injury during handling or installation of the fan and are
2014.06.12
D.C.C.
available for sale with this fan.
7. Unless otherwise noted, all testing of this fan is conducted at 25°C ambient
temperature and sixty-five percent (65%) relative humidity.
8. DO NOT store this fan in an environment with high humidity. This fan must be
stored in accordance with the attached specifications regarding storage
temperature. If this fan is stored for more than 6 months, SUNON recommends
functional testing before using.
9. SUNON reserves the right to use components from multiple sources at its
discretion. The use of components from other sources will not affect the
specifications as described herein.
10. The “Life Expectancy” of this fan has not been evaluated for use in combination
with any end application. Therefore, the Life Expectancy Test Reports (L10 and
MTTF Report) that relate to this fan are only for reference.
VI. WARRANTY
This fan is warranted against all defects which are proved to be fault in our
workmanship and material for one year from the date of our delivery. The sole
responsibility under the warranty shall be limited to the repair of the fan or the
replacement thereof, at SUNON’s sole discretion. SUNON will not be responsible
for the failures of its fans due to improper handing, misuse or the failure to follow
specifications or instructions for use. In the event of warranty claim, the customer
shall immediately notify SUNON for verification. SUNON will not be responsible
for any consequential damage to the customer’s equipment as a result of any fans
proven to be defective.
建 準 電 機
SUNONWEALTH
Page 13 of 14
2014.06.12
D.C.C.
Declaration of RoHS
Control declaration of environment-related substances/materials
1. In accordance with the Restriction of Hazardous Substances (RoHS) Directive
2011/65/EU, SUNON product have complied with law and discipline not to employ
the forbidden substances, and restrict the allowable concentration of some limited
substances deliberately in our components.