SUNON DP201A21 Datasheet

Page 1
2018.12.13
D.C.C.
DESCRIPTION : AXIAL AC FAN
DIMENSIONS : 120X120X38 mm
M O D E L : DP201A
P/N : 2123HBL.S.GN
SUNON
SPECIFICATION FOR APPROVAL
SUNON SPEC. NO.
: A12011170G-00
APPROVAL NO. :
APPROVED BY :
(AUTHORIZED)
SPEC.NO A12011170G-00
Alice-
DRAWN
chang
12/10
建準電機工業股份有限公司
SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD. NO. 30, LN. 296, XINYA RD., QIANZHEN DIST., TEL:886-7-8135888 KAOHSIUNG CITY 80673, TAIWAN (R.O.C) URL:http://www.sunon.com
CHECKED
Chin-jung
APPROVED
Schuma
FAX:886-7-8230505/8230606/8231010
E-mail: sunon@email.sunon.com.tw
ISSUE DATE 06.06.2018
EDITION 1
REVISION DATE
E.SPEC E51800159
12.10.2018
Page 2
SUNON
2018.12.13
D.C.C.
AXIAL AC FAN
MODEL : DP201A
P/N : 2123HBL.S.GN
CHARACTERISTICS
1. Motor Design : Reliable Shaded-Pole Motor Construction.
2. Insulation Resistance : 500Megohms minimum at 500 VDC.
3. Dielectric Strength : 1800 VAC for one second .
4. Motor Protection : Impedance protected.
5. Noise Level : Measured in a semi-anechoic chamber
with background noise level below 15
dB(A). The fan is running in free air with the
microphone at a distance of one meter
from the fan intake.
6. Tolerance :
15% on rated power and current.
±
7. Air Performance : Measured by a double chamber. The values
are recorded when the fan speed has stabilized
at rated voltage.
建準電機工業股份有限公司
SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD.
SPEC.NO A12011170G-00
ISSUE DATE 06.06.2018
REVISION DATE
E D I T I O N
P A G E 2 OF 9
12.10.2018
1
Page 3
2018.12.13
D.C.C.
SPECIFICATIONS
MODEL:
P/N :
1-1. Rated Voltage : 220-240 VAC 50/60 Hz
1-2. Operating Voltage Range : 185-240 VAC
1-3. Starting Voltage : 185 VAC(25 deg. C POWER ON/OFF)
1-4. Rated Speed : 2550/2550 RPM ± 10%
1-5. Air Delivery : 85.0/85.0 CFM
1-6. Static Pressure : 0.25/0.25 Inch-H2O
1-7. Rated Current : 0.069/0.065 AMP
1-8. Safety Current : 0.080/0.075 AMP
1-9. Rated Power : 10.80/10.40 WATTS
1-10. Safety Watts : 14.6/13.6 WATTS
1-11. Noise Level : 44.0/45.0 dB(A)
1-12. Direction of Rotation : Counter-clockwise viewed from front of fan blade
1-13. Operating Temperature : -10 to + 70 deg. C
1-14. Storage Temperature : -40 to + 70 deg. C
1-15. Bearing System : Precision ball bearing system
1-16. Weight : 480g
1-17. Safety : UL/CUR/TUV/CE Approvals
1-18. Protection : Automatic Restart Capability
□Polarity Protection
建準電機工業股份有限公司
SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD
DP201A
2123HBL.S.GN
SUNON
Note: In a situation where the fan is locked by an external force while the electricity is on, an increase in coil temperature will be prevented by temporarily turning off the electrical power to the motor. The fan will automatically restart when the locked rotor condition is released.
SPEC.NO A12011170G-00
ISSUE DATE 06.06.2018
P A G E 3 OF 9
REVISION DATE
E D I T I O N
12.10.2018
1
Page 4
SUNON
2018.12.13
D.C.C.
MODEL :
DP201A
P/N :
2123HBL.S.GN
PERFORMANCE CURVES
0 0.7 1.4 2.1 2.8
0.25
0.2
0.15
6.35
5.08
3.81
CMM
60Hz
50Hz
0.1
Static Pressure(Inch-H2O)
0.05
0
建準電機工業股份有限公司
SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD.
2.54
0 255075100
Air Flow-CFM
SPEC.NO A12011170G-00
ISSUE DATE 06.06.2018
P A G E 4 OF 9
1.27
0
mm
REVISION DATE
E D I T I O N
12.10.2018
1
Page 5
SUNON
2018.12.13
D.C.C.
MATERIAL
2. Material
2-1. Frame : DIE-CAST ALUMINUM
2-2. Impeller : Thermoplastic PBT of UL 94V-0
2-3. Lead Wire : UL3266, 24 awg, GRAY
DIMENSIONS
1. Air Flow Direction: Toward label side.
2. Best Mounting Direction: Any orientation.
4
G
8
UNIT:mm
建準電機工業股份有限公司
SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD.
SPEC.NO A12011170G-00
ISSUE DATE 06.06.2018
P A G E 5 OF 9
REVISION DATE
E D I T I O N
12.10.2018
1
Page 6
SUNON
2018.12.13
D.C.C.
Notes
Ⅰ.
SAFETY
1. DO NOT use or operate this fan in excess of the limitations set forth in this specification. SUNON is not responsible for the non-performance of this fan and/or any damages resulting from its use, if it is not used or operated in accordance with the specifications.
2. SUNON recommends adding a protection circuit to the product or application in which this fan is installed, such as a thermo-fuse, or current-fuse or thermo­protector. The failure to use such a device may result in smoke, fire, electric shock by insulation degradation in cases of motor lock, motor lead short circuit, overload, or over voltage, and/or other failure.
3. SUNON recommends installing a protection device to the product or application in which this fan is installed if there is a possibility of reverse­connection between VDC (+) and GND (-). The failure to install such a device may result in smoke, fire, and/or destruction, although these conditions may not manifest immediately.
4. This fan must be installed and used in compliance with all applicable safety standards and regulations.
5. Use proper care when handling and/or installing this fan. Improper handling or installation of this fan may cause damage that could result in unsafe conditions.
6. Use proper care during installation and/or wiring. Failure to use proper care may cause damage to certain components of the fan including, but not limited to, the coil and lead wires, which could result in smoke and/or fire.
7. DO NOT use power or ground PWM to control the fan speed. If the fan speed needs to be adjusted, please contact SUNON to customize the product design for your application.
8. For critical or extreme environments, including non stop operation, please contact SUNON and we will gladly provide assistance with your product selection to ensure an appropriate cooling product for your application.
建準電機工業股份有限公司
SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD.
SPEC.NO A12011170G-00
ISSUE DATE 06.06.2018
P A G E 6 OF 9
REVISION DATE
E D I T I O N
12.10.2018
1
Page 7
SUNON
g
2018.12.13
D.C.C.
Notes
II. SPECIFICATION MODIFICATION
1. SUNON offers engineering assistance on fan installation and cooling system design.
2. All changes, modifications and/or revisions to the specifications, if any, are incorporated in the attached specifications.
3. No changes, modifications and/or revisions to these specifications are effective absent agreement, by both SUNON and the customer, in writing.
4. This fan will be shipped in accordance with the attached specification unless SUNON and the customer have agreed otherwise, in writing, as specified in Paragraph 3, above.
III. OTHER
1. When building your device, please examine thoroughly any variation of EMC, temperature rise, life data, quality, etc. of this product by shock/drop/vibration testin
, etc. If there are any problems or accidents in connection with this product,
it should be mutually discussed and examined.
2. Use proper care when handling this fan. Components such as fan holders or bearings may be damaged, if touched with fingers or other objects. Additionally, static electricity (ESD) may damage the internal circuits of the fan.
3. DO NOT operate this fan in proximity to hazardous materials such as organic silicon, cyanogens, formalin, phenol, or corrosive gas environments including, but
S, SO2, NO2, or Cl2.
2
not limited to, H
4. SUNON recommends that you protect this fan from exposure to outside elements such as dust, condensation, humidity or insects. Exposure of this fan to outside elements such as dust, condensation, humidity or insects may affect its performance and may cause safety hazards. SUNON does not warrant against damage to the product caused by outside elements.
Re: The term can be excluded, if the fan has been with IP design and meets customer's IP requirement.
建準電機工業股份有限公司
SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD.
SPEC.NO A12011170G-00
ISSUE DATE 06.06.2018
P A G E 7 OF 9
REVISION DATE
E D I T I O N
12.10.2018
1
Page 8
SUNON
2018.12.13
D.C.C.
Notes
5. This fan must be installed properly and securely. Improper mounting may cause harsh resonance, vibration, and noise.
6. Fan guards may prevent injury during handling or installation of the fan and are available for sale with this fan.
7. Unless otherwise noted, all testing of this fan is conducted at 25°C ambient temperature and sixty-five percent (65%) relative humidity.
8. DO NOT store this fan in an environment with high humidity. This fan must be stored in accordance with the attached specifications regarding storage temperature. If this fan is stored for more than 6 months, SUNON recommends functional testing before using.
9. SUNON reserves the right to use components from multiple sources at its discretion. The use of components from other sources will not affect the specifications as described herein.
10. The “Life Expectancy” of this fan has not been evaluated for use in combination with any end application. Therefore, the Life Expectancy Test Reports (L10 and MTTF Report) that relate to this fan are only for reference.
IV. WARRANTY
This fan is warranted against all defects which are proved to be fault in our workmanship and material for one year from the date of our delivery. The sole responsibility under the warranty shall be limited to the repair of the fan or the replacement thereof, at SUNON’s sole discretion. SUNON will not be responsible for the failures of its fans due to improper handing, misuse or the failure to follow specifications or instructions for use. In the event of warranty claim, the customer shall immediately notify SUNON for verification. SUNON will not be responsible for any consequential damage to the customer’s equipment as a result of any fans proven to be defective.
建準電機工業股份有限公司
SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD.
SPEC.NO A12011170G-00
ISSUE DATE 06.06.2018
P A G E 8 OF 9
REVISION DATE
E D I T I O N
12.10.2018
1
Page 9
SUNON
2018.12.13
D.C.C.
Declaration of RoHS
Control declaration of environment- related substances/ materials
1. In accordance with the Restriction of Hazardous Substances (RoHS) Directive
2011/65/EU, SUNON product have complied with law and discipline not to employ the forbidden substances, and restrict the allowable concentration of some limited substances deliberately in our components.
No Substance Criteria
1 CFCs & HCFCs (ozone depleting substances)
2 Chlorinated Organic Solvent
Plastic (Frame, Impeller, wire harness, etc.)
Solder
3 Lead and its compounds
4 Cadmium and its compounds
5 PBBs and PBDEs
6 PCB and PCT
7 CP, Short-chain Chlorinated paraffins C10-13, Cl ≥48 wt%
8 Mirex
9 PCN
10 Hexavalent Chromium compounds
11 Mercury and its compounds
12 Asbestos
13 Organic Tin compounds
14 Azo compounds
15 TBBP-A in external case plastic parts of products (PCB is exempted)
16
Nickel in external case parts, which are likely to result in prolonged skin exposure
17 Hexabromocyclododecane (HBCDD)
18 Di-butyl Phthalate (DBP)
19 Benzyl butyl Phthalate (BBP)
20 Di-ethylhexyl Phthalate (DEHP)
21 Di-isobutyl Phthalate (DIBP)
Steel alloy
Aluminium alloy
Copper alloy
Solder
Parts composed of metals containing zinc (e.g. brass, zinc for die casting)
Plastic
Forbidden
Forbidden
<100ppm
<1000ppm
<3500ppm
<4000ppm
<4wt%
<20ppm
<100ppm
<5ppm
Forbidden
Forbidden
Forbidden
Forbidden
Forbidden
<100ppm
Forbidden
Forbidden
Forbidden
Forbidden
<1000ppm
<1000ppm
<1000ppm
<1000ppm
<1000ppm
<1000ppm
<1000ppm
建準電機工業股份有限公司
SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD.
SPEC.NO A12011170G-00
ISSUE DATE 06.06.2018
P A G E 9 OF 9
REVISION DATE
E D I T I O N
12.10.2018
1
Loading...