Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Copyright 2007Sun Microsystems,Inc., 4150 NetworkCircle, SantaClara, California95054, U.S.A. Allrights reserved.
Sun Microsystems,Inc. hasintellectual propertyrights relating to technology thatis described in this document.In particular, andwithout
limitation, theseintellectual propertyrights may includeone ormore ofthe U.S. patentslisted athttp://www.sun.com/patentsand one or
more additionalpatents orpending patent applicationsin theU.S. and inother countries.
This documentand the product to whichit pertainsare distributedunder licenses restricting their use, copying, distribution,and
decompilation. Nopart of the product orof thisdocument may bereproduced in any formby any means without priorwritten authorizationof
Sun andits licensors, if any.
Third-party software, including font technology, iscopyrighted and licensedfrom Sunsuppliers.
Parts ofthe productmay be derivedfrom BerkeleyBSD systems,licensed from the University ofCalifornia. UNIX is a registered trademarkin
the U.S.and in other countries, exclusivelylicensed throughX/Open Company, Ltd.
Sun, Sun Microsystems,the Sunlogo, Java, AnswerBook2,docs.sun.com, SunStorageTek,Netra, Sun Blade, Sun Fire,Sun StorEdge,Sun VTS,
and Solarisare trademarksor registeredtrademarks of Sun Microsystems, Inc.in theU.S. and inother countries.
All SPARC trademarksare usedunder licenseand are trademarks or registered trademarksof SPARC International, Inc. in theU.S. andin other
countries. Productsbearing SPARC trademarksare basedupon an architecture developedby Sun Microsystems, Inc.
The OPENLOOK and Sun™ Graphical UserInterface was developed by SunMicrosystems, Inc.for its users and licensees. Sun acknowledges
the pioneeringefforts ofXerox inresearching anddeveloping the conceptof visualor graphical userinterfaces forthe computer industry.Sun
holds anon-exclusive license from Xeroxto the Xerox Graphical User Interface, whichlicense also covers Sun’s licenseeswho implement OPEN
LOOK GUIsand otherwise comply with Sun’swritten license agreements.
U.S. GovernmentRights—Commercial use.Government users are subject to the SunMicrosystems, Inc.standard licenseagreement and
applicable provisionsof theFAR and its supplements.
DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,
INCLUDING ANYIMPLIED WARRANTY OF MERCHANTABILITY, FITNESSFOR A PARTICULARPURPOSE OR NON-INFRINGEMENT,
ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
Copyright 2007Sun Microsystems,Inc., 4150 NetworkCircle, SantaClara, Californie95054, États-Unis. Tous droits réservés.
Sun Microsystems,Inc. possèdeles droitsde propriété intellectuels relatifs àla technologiedécrite dans cedocument. Enparticulier, et sans
limitation, cesdroits depropriété intellectuelspeuvent inclure un ou plusieursdes brevetsaméricains listés surle site
http://www.sun.com/patents, un oules plusieursbrevets supplémentairesainsi que les demandes debrevet enattente aux les États-Unis et
dans d’autrespays.
Ce documentet le produit auquel ilse rapportesont protégéspar un copyrightet distribuéssous licences, celles-cien restreignent l’utilisation,
la copie,la distribution, et la décompilation.Aucune partie de ce produitou documentne peut être reproduitesous aucune forme, par quelque
moyen quece soit, sans l’autorisation préalableet écrite de Sun etde sesbailleurs de licence,s’il yen a.
Tout logiciel tiers,sa technologierelative auxpolices de caractères, comprise, est protégé parun copyrightet licencié par des fournisseursde
Sun.
Des partiesde ce produit peuvent dériverdes systèmesBerkeley BSD licenciés par l’Universitéde Californie. UNIX est unemarque déposée
aux États-Uniset dans d’autres pays, licenciéeexclusivement parX/Open Company, Ltd.
Sun, SunMicrosystems, lelogo Sun, Java,AnswerBook2, docs.sun.com,Sun StorageTek, Netra,Sun Blade, SunFire, SunStorEdge, SunVTS, et
Solaris sontdes marquesde fabrique oudes marquesdéposées deSun Microsystems, Inc. aux États-Uniset dans d’autres pays.
Toutes les marques SPARC sontutilisées sous licence et sontdes marquesde fabrique ou des marquesdéposées deSPARCInternational, Inc.
aux États-Uniset dans d’autres pays. Lesproduits portantles marquesSPARCsont basés sur une architecture développée par Sun
Microsystems, Inc.
L’interfaceutilisateur graphiqueOPEN LOOK etSun™ aété développée parSun Microsystems,Inc. pourses utilisateurs etlicenciés. Sun
reconnaît lesefforts depionniers deXerox dans la recherche et le développementdu conceptdes interfaces utilisateurvisuelles ougraphiques
pour l’industrieinformatique. Sun détient une licensenon exclusive de Xerox surl’interface utilisateurgraphique Xerox,cette licence couvrant
également leslicenciés de Sun implémentant lesinterfaces utilisateur graphiques OPEN LOOKet seconforment en outre aux licences écrites de
Sun.
LA DOCUMENTATION EST FOURNIE "EN L’ÉTAT" ET TOUTES AUTRES CONDITIONS, DÉCLARATIONS ET GARANTIES EXPRESSES
OU TACITES SONT FORMELLEMENT EXCLUES DANS LA LIMITE DE LA LOI APPLICABLE, Y COMPRIS NOTAMMENT TOUTE
GARANTIE IMPLICITE RELATIVE À LA QUALITÉ MARCHANDE, À L’APTITUDE À UNE UTILISATION PARTICULIÈRE OU À
L’ABSENCE DE CONTREFAÇON.
Please
Recycle
Contents
Prefacexi
1.Product Overview1
Single and Dual Port HBA Features2
Minimum System Hardware Requirements3
Supported Operating Systems4
2.Supported System Configurations5
Basic Interoperability6
Host Platform Support6
Storage System Support7
Fibre Channel Switch Support7
Solaris 8, 9, and 10 Operating System Requirements8
Minimum Operating System Levels8
Red Hat Enterprise Linux and SuSE Linux Enterprise Server Operating System
Requirements9
Minimum OS Levels9
Windows 2000 and Windows Server 2003 Operating System Requirements10
Minimum OS Levels10
Known Issues and Bugs10
iii
3.Hardware Installation13
▼To Verify the Packaging Contents14
▼To Install the HBA Hardware14
▼To Attach the Optical Cable16
▼To Apply Power18
▼To Verify Proper Installation in SPARC Platforms19
▼To Verify the Attached Storage21
▼To Verify Proper Installation in x64 Based Systems22
Service Contact Information22
4.Software Installation23
Installing the HBA Driver With Solaris Operating Systems24
▼To Download Solaris Patch Clusters24
Downloading HBA Driver Packages and Patches for Solaris 8 and 9 for
SPARC24
▼To Run An install_it Script Installation25
▼To Do A Manual Installation26
Downloading HBA Driver Packages and Patches for Solaris 10 for SPARC or
x64/x8628
▼To Download the Packages28
▼To Download the Patches29
Diagnostic Support29
Installing the HBA Driver With Red Hat and SuSE Operating Systems30
▼To Download and Install the Packages30
Red Hat and SuSE OS Diagnostic Support31
Creating a Linux Boot Disk31
Installing the HBA Driver With Windows 2000 or Windows Server 2003 Operating
Systems32
▼To Install the HBA Driver32
▼To Install the Diagnostic and Management Utilities33
ivSun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-
▼To Create a Windows Boot Disk33
Service Contact Information33
A.Declaration of Conformity, Regulatory Compliance, and Safety Statements35
Declaration of Conformity37
Regulatory Compliance Statements39
Safety Agency Compliance Statement43
Contentsv
viSun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-
Figures
FIGURE 3-1Removing the Bracket Screws 15
FIGURE 3-2Installing the Single and Dual Port HBAs 16
FIGURE 3-3Attaching the Optical Cable 17
vii
viiiSun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-
Tables
TABLE 1-1Single and Dual Port HBA Features 2
TABLE 2-1Sun Solaris 8, 9, and 10; Red Hat Enterprise Linux and SuSE Enterprise Linux; and Windows
2000 and Windows Server 2003 Host Platform Support 6
TABLE 3-1Optical Cable Specifications 17
TABLE 3-2LED Indicator Status Definitions 18
TABLE 3-320
TABLE 3-421
TABLE 4-1Sun Solaris 8 and 9 Patches 27
TABLE 4-2Required Patches 29
ix
xSun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-
Preface
This manual describes how to install, configure, and test the Sun StorageTek™
Enterprise PCI-X 4 Gb Fibre Channel (FC) Single or Dual Port Emulex Host Bus
Adapter (HBA). This document is written for technicians, system administrators,
authorized service providers (ASPs), and users who have advanced experience
troubleshooting and replacing hardware. Additional Sun StorageTek Enterprise PCIX 4 Gb FC Single and Dual Port Emulex HBAs can be ordered from Sun
Microsystems by two marketing part numbers:
Number of PortsMarketing Part Number
SingleSG-XPCI1FC-EM4-Z
DualSG-XPCI2FC-EM4-Z
How This Document Is Organized
Chapter 1 provides an overview of the product.
Chapter 2 describes the operating systems, host platforms, switches, and storage
systems that support the HBAs.
Chapter 3 describes how to install the HBAs.
Chapter 4 describes how to download and install the HBA drivers and patches.
Appendix A provides the required product safety information.
xi
Using UNIX Commands
This document does not contain information about basic UNIX®commands and
procedures such as shutting down the system, booting the system, and configuring
devices. Refer to the following for this information:
■ Software documentation that you received with your system
■ Solaris™ Operating System documentation, which is at:
http://docs.sun.com
Shell Prompts
ShellPrompt
C shellmachine-name%
C shell superusermachine-name#
Bourne shell and Korn shell$
Bourne shell and Korn shell superuser#
xii Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Typographic Conventions
Typeface
AaBbCc123The names of commands, files,
AaBbCc123What you type, when contrasted
AaBbCc123Book titles, new words or terms,
* The settings on your browser might differ from these settings.
*
MeaningExamples
Edit your.login file.
and directories; on-screen
computer output
with on-screen computer output
words to be emphasized.
Replace command-line variables
with real names or values.
Use ls -a to list all files.
% You have mail.
su
%
Password:
Read Chapter 6 in the User’s Guide.
These are called class options.
Yo u must be superuser to do this.
To delete a file, type rm filename.
Related Documentation
The following documents are available at:
http://www.sun.com/products-nsolutions/hardware/docs/Network_Storage_Solutions/SAN/san_software/
index.html and http://docs.sun.com/app/docs/doc/819-0139.
TitlePart Number
Sun StorEdge SAN Foundation Software 4.4 Guide to Documentation817-3670-xx
Sun StorEdge SAN Foundation Software 4.4 Installation Guide817-3671-xx
Sun StorEdge SAN Foundation Software 4.4 Configuration Guide817-3672-xx
Sun StorEdge Traffic Manager Installation and Configuration Guide817-3674-xx
Sun StorEdge SAN Foundation Software 4.4.9 Release Notes817-5604-xx
Solaris Fibre Channel and Storage Multipathing Administration Guide
(contains Sun Solaris 10 Fibre Channel Operating System booting procedure)
817-0139-xx
Prefacexiii
Documentation, Support, and Training
Sun FunctionURL
Documentationhttp://www.sun.com/documentation/
Supporthttp://www.sun.com/support/
Traininghttp://www.sun.com/training/
Third-Party Web Sites
Sun is not responsible for the availability of third-party web sites mentioned in this
document. Sun does not endorse and is not responsible or liable for any content,
advertising, products, or other materials that are available on or through such sites
or resources. Sun will not be responsible or liable for any actual or alleged damage
or loss caused by or in connection with the use of or reliance on any such content,
goods, or services that are available on or through such sites or resources.
Sun Welcomes Your Comments
Sun is interested in improving its documentation and welcomes your comments and
suggestions. You can submit your comments by going to:
http://www.sun.com/hwdocs/feedback
Please include the title and part number of your document with your feedback:
Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation &
Interop Guide, part number 819-5532-12
xiv Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
CHAPTER
1
Product Overview
This chapter provides a basic overview of the Sun StorageTek Enterprise PCI-X 4 Gb
FC Single and Dual Port Emulex HBAs (henceforth referred to as single and dual portHBAs). It contains the following topics:
■ “Single and Dual Port HBA Features” on page 2
■ “Minimum System Hardware Requirements” on page 3
1
Single and Dual Port HBA Features
The single and dual port HBAs consist of a single-slot PCI-X 2.0 bus expansion
board that interfaces a 64-bit PCI bus to one or two Fibre Channel (FC) optical media
busses. The single and dual port HBAs support 32-bit and 64-bit PCI transfers as a
master bus during direct memory access (DMA) transfers and 16-bit transfers as a
slave during parallel input/output (PIO) operations, as well as PCI-X 1.0 and 2.0
transactions. The channels of the single and dual port HBAs can act as either
initiators or targets. In the dual-port HBA, the two channels operate independently
and each supports a separate bus that operates at 4.25 Gbits per second. The single
and dual port HBAs are also backward compatible with 2.125-Gbit-per-second and
1.0625-Gbit-per-second busses.
One or two Small Form Factor (SFF) optical transceivers are used to connect to the
external FC busses. One Helios FC Controller chip is used to support one or two
independent FC busses.
See
TABLE 1-1 for a list of the single and dual port HBA features.
TABLE 1-1Single and Dual Port HBA Features
FeatureDescription
PCI signaling environment3.3-V PCI busses as well as PCI-X 1.0 and 2.0 (mode 2).
Incompatible with 5.0-V PCI slots
PCI/PCI-X transfer rate (max)264 MB/sec burst rate (64 bit @ 33 MHz PCI).
528 MB/sec burst rate (64 bit @ 66 MHz PCI).
1064 MB/sec burst rate (64 bit @ 133 MHz PCI-X)
2128 MB/sec burst rate (64 bit @ 266 MHz PCI-X)
Number of FC bussesOne or two
Number of devices supported126 devices per FC loop
FC bus type (external)Fiber optic media, short wave, multimode fiber (400-M5
SN-S)
FC transfer rate400 MB/sec per loop maximum, half duplex
800 MB/sec per loop maximum, full duplex
FC interface chipEmulex Helios PCI-X to FC
RAM1.5 MB SRAM
Flash ROM2/4 MB Flash (2 MB per FC port; 4 MB total on dual-
port HBA) containing BIOS, firmware, and Sun FCode.
The flash is field programmable.
External connectorsOne or two LC duplex connectors, one per channel
2Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
TABLE 1-1Single and Dual Port HBA Features (Continued)
FeatureDescription
Maximum FC cable length1 Gbps: 500 meters using 50/125 µm core fiber
300 meters using 62.5/125 µm core fiber
2 Gbps: 300 meters using 50/125 µm core fiber
150 meters using 62.5/125 µm core fiber
4 Gbps: 150 meters using 50/125 µm core fiber
70 meters using 62.5/125 µm core fiber
LED indicators1 green and 1 yellow light-emitting diode (LED) per FC
channel as status indicators
Form FactorPCI Low Profile Form Factor (MD2) 6.600 in. x 2.536 in.
Minimum System Hardware
Requirements
Your system must have an available PCI or PCI-X 64-bit slot to support these single
and dual port HBAs.
This product uses +3.3V signaling only, and is incompatible with +5.0-V signaling
PCI slots.
Chapter 1 Product Overview3
Supported Operating Systems
You can use the single and dual port HBAs with the following operating systems:
■ Solaris 8, 9, and 10 Operating Systems
To use the single and dual port HBAs with these operating systems, you must use
the Sun driver as described in “Solaris 8, 9, and 10 Operating System
Requirements” on page 8.
■ Red Hat Enterprise Linux and SuSE Linux Enterprise Server Operating Systems
To use the single and dual port HBAs with these operating systems, you must use
the Emulex driver as described in “Red Hat Enterprise Linux and SuSE Linux
Enterprise Server Operating System Requirements” on page 9.
■ Windows 2000 and Windows Server 2003 Operating Systems
To use the single and dual port HBAs with this OS, you must use the Emulex
driver as described in “Windows 2000 and Windows Server 2003 Operating
System Requirements” on page 10.
4Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
CHAPTER
2
Supported System Configurations
This chapter describes the operating systems, host platforms, storage, and
infrastructure configurations that support the Sun StorageTek Enterprise PCI-X 4 Gb
FC Single and Dual Port Emulex HBAs (henceforth referred to as single and dual portHBAs). It contains the following topics:
■ “Basic Interoperability” on page 6
■ “Solaris 8, 9, and 10 Operating System Requirements” on page 8
■ “Red Hat Enterprise Linux and SuSE Linux Enterprise Server Operating System
Requirements” on page 9
■ “Windows 2000 and Windows Server 2003 Operating System Requirements” on
page 10
■ “Known Issues and Bugs” on page 10
5
Basic Interoperability
This section provides information about platform, storage, and switch compatibility
permitting a heterogeneous Fibre Channel network design with the single and dual
port HBAs. This section contains the following topics:
■ “Host Platform Support” on page 6
■ “Storage System Support” on page 7
■ “Fibre Channel Switch Support” on page 7
Host Platform Support
The single and dual port HBAs are supported by the platforms and operating
systems listed in
TABLE 2-1.
TABLE 2-1Sun Solaris 8, 9, and 10; Red Hat Enterprise Linux and SuSE Enterprise Linux;
and Windows 2000 and Windows Server 2003 Host Platform Support
PlatformSupported OS
Sun Blade™ 1000, 1500, 2000, and 2500
workstations
Sun Fire™ V210, V240, and V250 serversSun Solaris
Sun Fire V440 serverSun Solaris
Sun Fire V480, V490, V880, and V890 serversSun Solaris
Sun Fire V1280, and E2900 serversSun Solaris
Sun Fire 4800, 4810, and E4900 serversSun Solaris
Sun Fire 6800 and E6900 serversSun Solaris
Sun Fire 12K and E20K serversSun Solaris
Sun Fire 15K and E25K serversSun Solaris
Sun Fire 280R serverSun Solaris
Netra™ 20, 240, 440, 1280, and t1400/t1405
servers
Sun Fire T2000 serverSun Solaris
Sun Fire V20z and V40z serversSun Solaris, Linux, and Windows
Sun Fire X4100, X4200, and X4200 M2 serversSun Solaris, Linux, and Windows
Sun Solaris
Sun Solaris
6Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Storage System Support
The single and dual port HBAs support the storage systems are listed below.
■ Sun StorEdge™ 3510 and 3511 FC arrays
■ Sun StorEdge 6020, 6120, and 6320 arrays
■ Sun StorEdge 6130 array
■ Sun StorEdge 6920 system
■ Sun StorEdge L25 and L100 tape libraries
■ Sun StorEdge C4 tape library
■ Sun StorEdge L500 tape library
■ Sun StorEdge L180 and L700 tape libraries
■ Sun StorEdge L5500 and L8500 tape libraries
Fibre Channel Switch Support
The single and dual port HBAs support the Fibre Channel switches listed below.
■ QLogic SANbox 5200 2 Gb switch
■ Sun StorEdge Network 2 Gb switch
■ QLogic SANbox 5600 and 5602 Stackable 4 Gb FC Switches
■ Sun StorEdge Network 2 Gb Brocade SilkWorm 3200 and 3800 switches
■ Sun StorEdge Network 2 Gb Brocade SilkWorm 3250 and 3850 switches
■ Sun StorEdge Network 2 Gb Brocade SilkWorm 3900 switch
■ Sun StorEdge Network 2 Gb Brocade SilkWorm 12000 and 24000 Core Fabric
switches
■ Sun StorEdge Network 4 Gb Brocade SilkWorm 4100 switch
■ Sun StorEdge Network 4 Gb Brocade SilkWorm 48000 and 200E switches
■ Sun StorEdge Network 2 Gb McDATA Sphereon 4300 switch
■ Sun StorEdge Network 2 Gb McDATA Sphereon 4500 switch
■ Sun StorEdge Network 2 Gb McDATA Intrepid 6064 director
■ Sun StorEdge Network 2 Gb McDATA Intrepid 6140 director
Chapter 2 Supported System Configurations7
Solaris 8, 9, and 10 Operating System
Requirements
This section contains information about using the single and dual port HBAs with
the Solaris OS.
Minimum Operating System Levels
■ Solaris 8 SPARC
■ Solaris 9 SPARC OS with the recommended patch cluster
■ Solaris 10 for SPARC and x64/x86 with the recommended patch cluster
Note – Refer to your host platform documentation to determine minimum Solaris
version required for your HBA installation.
®
OS Update 4/01 with the recommended patch cluster
8Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Red Hat Enterprise Linux and SuSE
Linux Enterprise Server Operating
System Requirements
This section contains information about using the single and dual port HBAs in Red
Hat Enterprise Linux and SuSE Linux Enterprise operating systems.
Minimum OS Levels
■ Red Hat Enterprise Linux (RHEL) 3
■ Red Hat Enterprise Linux (RHEL) 4
■ SuSE Linux Enterprise Server (SLES) 8
■ SuSE Linux Enterprise Server (SLES) 9
The Linux drivers and HBA diagnostic and management utilities supporting the
single and dual port HBAs with the Linux OS are available for download at the Sun
designated page:
http://www.emulex.com/ts/docoem/framsun/10k.htm
Drivers that support the Linux 2.4 and 2.6 kernels are provided. The Linux 2.4 kernel
is used in Red Hat Enterprise Linux (RHEL) 3 and SuSE Linux Enterprise Server
(SLES) 8. The Linux 2.6 kernel is used in RHEL 4 and SLES 9.
Note – Refer to your host platform documentation and the Emulex web site to
determine minimum RHEL and SLES version required for your HBA installation.
Chapter 2 Supported System Configurations9
Windows 2000 and WindowsServer 2003
Operating System Requirements
This section contains information about using the single and dual port HBAs in
Windows 2000 and Windows Server 2003 operating systems.
Minimum OS Levels
■ Windows 2000
■ Windows Server 2003
Note – Refer to your host platform documentation and the Emulex web site to
determine minimum Windows 2000 and Windows Server 2003 versions required.
Known Issues and Bugs
The following HBA issues exist at this time.
■ CR 6266132. Booting from the Sun StorEdge 3500 family array fails with the single
and dual port HBAs in certain configurations.
Workaround: None; booting from a Sun StorEdge 3500 family array is not
Workaround: None at this time. A fix is targeted for the Sun StorEdge SAN
Foundation Software release 4.4.10 for Sun Solaris OS 8 and 9 SPARC, patches
120222-10 (S10_SPARC), and 120223-10 (S10_x86).
■ CR 6367185. Performing I/O operations on HBA ports 0 and 1 intermittently
stops when using Emulex 10k cards with the Sun StorEdge 3500 family arrays.
Workaround: None at this time. A fix is being investigated.
■ CR 6313136. A Sun StorEdge 3510 FC Array 0x47 SCSI parity error occurs when
the Emulex HBA is connected to Sun StorEdge 3510 JBOD FC Array
Workaround: None at this time. A fix is currently under investigation.
.
10Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
■ CR 6381138. Sun StorEdge 3511 and 3510 Arrays can experience a SCSI transport
failure for a’timeout’ reason.
Workaround: None at this time. A fix is being investigated.
■ CR 6352189. OBP probe gives unexpected output for unmapped channel / Sun
StorEdge 3500 family arrays. This only occurs on the first probe-SCSI-all after a
reset.
Workaround: Perform another probe-scsi-all after a reset. The second try will
yield correct results.
A fix will be made available in the next FCode release after version 1.50a8.
■ CR 6306640. Enabling the BIOS of the “LP10000” card causes the system to fail to
boot. Enabling the HBA BIOS hangs up all boot processes.
Workaround: None at this time. A fix is currently under investigation.
Disable the single or dual port HBA BIOS (default setting) and boot from the
system disk, or other supported boot device.
Chapter 2 Supported System Configurations11
12Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
CHAPTER
3
Hardware Installation
This chapter provides instructions for installing the Sun StorageTek Enterprise PCI-X
4 Gb FC Single and Dual Port Emulex HBAs (henceforth referred to as single and dualport HBAs) in your system. It contains the following topics:
■ “To Verify the Packaging Contents” on page 14
■ “To Install the HBA Hardware” on page 14
■ “To Attach the Optical Cable” on page 16
■ “To Apply Power” on page 18
■ “To Verify Proper Installation in SPARC Platforms” on page 19
■ “To Verify Proper Installation in x64 Based Systems” on page 22
■ “To Verify the Attached Storage” on page 21
■ “To Verify Proper Installation in x64 Based Systems” on page 22
■ “Service Contact Information” on page 22
Caution – Damage to the HBA can occur as the result of careless handling or
electrostatic discharge (ESD). Always handle the HBA with care to avoid damage to
electrostatic sensitive components.
To minimize the possibility of ESD-related damage, Sun strongly recommends using
both a workstation anti-static mat and an ESD wrist strap. You can get an ESD wrist
strap from any reputable electronics store or from Sun as part number #250-1007.
Observe the following precautions to avoid ESD-related problems:
■ Leave the HBA in its antistatic bag until you are ready to install it in the system.
■ Always use a properly fitted and grounded wrist strap or other suitable ESD
protection when handling the HBA and observe proper ESD grounding
techniques.
■ Hold the HBA by the edge of the PCB or mounting bracket, not the connectors.
■ Place the HBA on a properly grounded antistatic work surface pad when it is out
of its protective antistatic bag.
13
▼ To Verify the Packaging Contents
● Confirm that the single or dual port HBAs are shipped with the following
items:
■ Sun StorageTek Enterprise PCI-X 4Gb FC Single or Dual Port Emulex HBA
■ Alternate PCI bracket
■ Accessing Documentation, 819-1209-xx
▼ To Install the HBA Hardware
To install the single and dual port HBAs, you must open the system and identify an
empty PCI or PCI-X slot. The single and dual port HBAs are keyed to prevent
installation in +5.0-V signaling PCI slot types. If necessary, consult your system
manual for instructions on removing the system cover.
1. Record IEEE and serial numbers.
Each HBA is shipped with at least one unique 64-bit identifier called the IEEE
address. The Fibre Channel industry uses a World Wide Name (WWN) derived from
the IEEE address. This number is needed for FC connectivity. Because the dual-port
HBA has two ports, it has two IEEE addresses. The IEEE address is used for
configuring your system. The serial number is used for communicating with Sun. All
numbers are clearly marked on the board. Record these numbers before installation.
2. Shut down, power off, and unplug the system.
3. Remove the system case.
4. Remove the blank panel from an empty PCI or PCI-X slot.
5. If needed, replace the low-profile PCI bracket with the standard mounting
bracket by performing the following steps:
Note – The single and dual port HBAs are shipped with a low-profile PCI bracket
installed. This bracket is approximately 3.11 in. (7.9 cm) long. A standard mounting
bracket, which is approximately 4.75 in. (12.6 cm), is provided with each X-option
order.
a. Remove the mounting bracket screws from the single and dual port HBAs
FIGURE 3-1).
(see
14Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
FIGURE 3-1 Removing the Bracket Screws
b. Remove the bracket and store it for future use.
c. Align the new mounting bracket tabs with the holes in the HBA.
Note – Be careful not to push the bracket past the transceiver housing’s grounding
tabs. Ensure that the LEDs are properly aligned with the holes in the bracket.
d. Replace the screws that attach the HBA to the bracket.
6. Insert the HBA into the empty PCI or PCI-X slot. Press firmly until the adapter
is seated. See
FIGURE 3-2.
7. Secure the HBA mounting bracket to the case with the panel screw or clip.
8. Replace the system case and tighten the case screws.
The HBA is now installed in the system and is ready for the optical cable
attachment.
Chapter 3 Hardware Installation15
FIGURE 3-2 Installing the Single and Dual Port HBAs
Lever
Screw Hole
HBA
HBA retaining
bracket
64-bit PCI slot
32-bit PCI slot
Slot covers
System chassis
Note – FIGURE 3-2 is a typical installation, which may differ from your installation.
▼ To Attach the Optical Cable
Note – The single and dual port HBAs do not allow normal data transmission on an
optical link unless it is connected to another similar or compatible Fibre Channel
product (that is, multimode to multimode).
Use multimode fiber-optic cable, intended for short-wave lasers, that adheres to the
specifications in
16Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
300 meters at 1.0625 Gbit/sec
150 meters at 2.125 Gbit/sec
70 meters at 4.25 Gbit/sec
500 meters at 1.0625 Gbit/sec
300 meters at 2.125 Gbit/sec
150 meters at 4.25 Gbit/sec
2 metersLC
2 metersLC
Follow these steps when attaching the optical cable:
1. Connect the fiber-optic cable to an LC connector on the dual port HBA (see
FIGURE 3-3).
FIGURE 3-3 Attaching the Optical Cable
Por t 1
Por t 2
2. Connect the other end of the cable to the Fibre Channel device.
After the optical cable is connected to the HBA, you are ready to apply power to the
system.
Chapter 3 Hardware Installation17
▼ To Apply Power
1. Verify that the HBA is securely installed in the system.
2. Verify that the correct optical cable is attached.
3. Plug in and power on the system.
4. Observe the status of light-emitting diodes (LEDs) for the power-on self-test
(POST) results as shown in
TABLE 3-2 summarizes LED indicator combinations. The LEDs can be seen
through the openings in the HBA’s mounting bracket. Each port has a
corresponding set of LEDs that provide a visual indication of the operating state.
The slow blink rate is 1 Hz; the fast blink rate is 4 Hz; the flashing state is an
irregular on/off appearance reflecting program activity. For the Link Rate,
between each group of fast blinks (1, 2, or 3), there is a 1-Hz pause when the LED
is off. You should observe the LED sequence for several seconds to ensure that
the pause is correctly identified.
TABLE 3-2LED Indicator Status Definitions
Green LEDYellow LEDState
OffOffWake Up Failure (Dead Board)
OffOnPOST Failure (Dead Board)
OffSlow BlinkWake-Up Failure Monitor
OffFast BlinkFailure in POST
OffFlashingPOST Processing in Progress
OnOffFailure While Functioning
OnOnFailure While Functioning
On1 Fast Blink1-Gb Link Rate –
On2 Fast Blink2-Gb Link Rate –
On3 Fast Blink4-Gb Link Rate –
Slow BlinkOffNormal - Link Down
Slow BlinkOnNot defined
Slow BlinkSlow BlinkOffline for Download
Slow BlinkFast BlinkRestricted Offline Mode
TABLE 3-2.
Normal, link up
Normal, link up
Normal, link up
(Waiting for Restart)
18Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
TABLE 3-2LED Indicator Status Definitions (Continued)
Green LEDYellow LEDState
Slow BlinkFlashingRestricted Offline Mode,
test active
Fast BlinkOffDebug Monitor in Restricted
Mode
Fast BlinkOnNot defined
Fast BlinkSlow BlinkDebug Monitor in Test Fixture
Mode
Fast BlinkFast BlinkDebug Monitor in Remote
Debug Mode
Fast BlinkFlashingNot defined
▼ To Verify Proper Installation in SPARC
Platforms
1. Enter the show-devs command at the ok prompt to list the installed devices.
The single and dual port HBAs can be identified in the output containing the
SUNW,emlxs@n and SUNW,emlxs@n,1 node names, where n is usually a single-digit
number from 0 to 9.
Chapter 3 Hardware Installation19
2. To positively identify the port as a Sun StorageTek 4 Gb FC port, access the
SUNW,emlxs@N entries and enter .properties as shown in the example that
follows.
In this example, there is one Dual Channel SG-XPCI2FC-EM4-Z adapter installed:
TABLE 3-3
{1} ok .properties
assigned-addresses83000910 00000000 00104000 00000000 00002000
20Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
▼ To Verify the Attached Storage
● If online storage is connected to the HBA installed in a SPARC system, use the
apply show-children command to list the attached storage.
In the example that follows, a storage JBOD has twelve targets attached to one port
of the dual-ported HBA.
TABLE 3-4
{0} ok apply show-children /pci@7c0/pci@0/pci@9/SUNW,emlxs@0
Device ALPA b6 WWPN 215000c0ff00223d
LUN 0 ESI Device SUN StorEdge 3510F D1046
Link attention
Device ALPA b9 WWPN 2100000c50c30555
LUN 0 Disk SEAGATE ST3146807FC 0006
Device ALPA ba WWPN 2100000c50c30525
LUN 0 Disk SEAGATE ST3146807FC 0006
Device ALPA bc WWPN 500000e010172831
LUN 0 Disk FUJITSU MAP3147F SUN146G0301
Device ALPA c3 WWPN 2100000c50c3051b
LUN 0 Disk SEAGATE ST3146807FC 0006
Device ALPA c5 WWPN 2100000c50c30567
LUN 0 Disk SEAGATE ST3146807FC 0006
Device ALPA c6 WWPN 500000e0101727d1
LUN 0 Disk FUJITSU MAP3147F SUN146G0301
Device ALPA c7 WWPN 21000004cf64f1db
LUN 0 Disk SEAGATE ST336752FSUN36G 0508
Device ALPA c9 WWPN 2100000c50c30513
LUN 0 Disk SEAGATE ST3146807FC 0006
Device ALPA ca WWPN 500000e0101727b1
LUN 0 Disk FUJITSU MAP3147F SUN146G0301
Device ALPA cb WWPN 2100000c50c3050e
LUN 0 Disk SEAGATE ST3146807FC 0006
Device ALPA cc WWPN 21000004cf64dc04
LUN 0 Disk SEAGATE ST336752FSUN36G 0508
Device ALPA cd WWPN 21000004cf5728c0
LUN 0 Disk SEAGATE ST373307FSUN72G 0407
{0} ok
Note – You may need to use the reset-all command before entering apply
show-children.
Chapter 3 Hardware Installation21
▼ To Verify Proper Installation in x64 Based
Systems
● Follow the instructions in the BIOS documentation provided with your
system.
Service Contact Information
If you need help installing or using this product, call 1-800-USA-4SUN, or go to:
http://www.sun.com/service/contacting/
22Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
CHAPTER
4
Software Installation
After you have completed the hardware installation and powered on the computer,
follow the instructions listed for your operating system to install the single and dual
port HBA driver and any other utilities required for your installation. The following
sections contain the instructions for installing software and the driver for the single
and dual port HBAs.
This chapter contains the following topics:
■ “Installing the HBA Driver With Solaris Operating Systems” on page 24
■ “Installing the HBA Driver With Red Hat and SuSE Operating Systems” on
page 30
■ “Installing the HBA Driver With Windows 2000 or Windows Server 2003
Operating Systems” on page 32
■ “Service Contact Information” on page 33
23
Installing the HBA Driver With Solaris
Operating Systems
You must first install the latest available patch clusters for your Solaris OS.
This section contains the following topics:
■ “To Download Solaris Patch Clusters” on page 24
■ “Downloading HBA Driver Packages and Patches for Solaris 8 and 9 for SPARC”
on page 24
■ “Downloading HBA Driver Packages and Patches for Solaris 10 for SPARC or
x64/x86” on page 28
■ “Diagnostic Support” on page 29
▼ To Download Solaris Patch Clusters
1. Go to the SunSolve site at: http://sunsolve.sun.com.
2. Click on Patch Portal under Recommended and Security Patches.
3. Click on Recommended Patch Clusters under Recommended Solaris Patch
Clusters, J2SE, and Java Enterprise System Clusters.
4. Select and download the patch cluster applicable to your installation.
Install this patch cluster before installing single and dual port HBA driver packages
and patches.
Downloading HBA Driver Packages and Patches
for Solaris 8 and 9 for SPARC
The single and dual port HBAs are supported on the Sun Solaris 8 and 9 Operating
Systems. The drivers for the single and dual port HBAs are delivered as packages
and patches on Solaris 8 and 9 OS. The Sun StorEdge SAN Foundation Software
version 4.4.8 must be installed as a minimum.
Note – Packages are required only for Sun Solaris for SPARC 8 and 9 releases. Later
Sun Solaris for SPARC releases do not require the installation of these packages.
24Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
The packages and patches are available either bundled as a script posted in the Sun
Download Center (SDLC), or as individual packages and patches. Sun recommends
using the install_it script, see “To Run An install_it Script Installation” on
page 25. To install the packages and patches manually, see “To Do A Manual
Installation” on page 26.
▼ To Run An install_it Script Installation
The packages and patches are available from the Sun Download Center (SDLC).
1. Go to http://www.sun.com/storage/san.
The Storage Area Networks (SAN) page displays.
2. Scroll to the bottom of the page and under Get the Software, click the “Sun
StorEdge SAN 4.4 release Software/Firmware Upgrades and Documentation”
link.
If you are not already logged in, the Login page displays.
3. Enter your User Name and Password and click Login.
If you have not already registered, click Register Now before proceeding.
4. Accept the License Agreement.
The Download page is now available.
5. Locate and click the download file install_it script, SAN 4.4.x, README,
English, and print the instructions.
6. Locate and click the download file install_it script, SAN 4.4.8, English
You will be prompted for a download directory. Sun suggests that you download the
packages to your /tmp directory.
7. Unzip the downloaded file.
8. Locate the executable file install_it and run it.
The necessary packages and patches install.
9. Reboot the system after installing all patches.
This completes the driver installation.
Chapter 4 Software Installation25
▼ To Do A Manual Installation
Optionally, for Solaris 8 and 9, if you do not want to use the install_it script,
install the driver by adding the following packages and then patches.
Packages
The packages are available from the Sun Download Center (SDLC).
1. Go to http://www.sun.com/storage/san.
The Storage Area Networks (SAN) page displays.
2. Scroll to the bottom of the page and under Get the Software, click the “Sun
StorEdge SAN 4.4 release Software/Firmware Upgrades and Documentation”
link.
If you are not already logged in, the Login page displays.
3. Enter your User Name and Password and click Login.
If you have not already registered, click Register Now before proceeding.
4. Accept the License Agreement.
The Download page is now available.
5. Locate and click the appropriate download file:
■ Solaris 8 SFS Base Packages, English
■ Solaris 9 SFS Base Packages, English
6. Provide the path to a directory location for the download file.
7. Follow the README instructions to install the packages.
The following package names are contained in both Solaris 8 and 9 download files
and must be installed in the order given below.
■ SUNWemlxs
■ SUNWemlxsx
■ SUNWemlxu
■ SUNWemlxux
Patches
Perform the following steps to download the Solaris 8 and 9 patches.
26Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
1. Go to http://sunsolve.sun.com.
The SunSolve Online license agreement page displays.
2. Accept the License Agreement.
The SunSolve Online page displays.
3. Under Patches and Updates, click PatchFinder.
4. Download the appropriate patches for your system from
TABLE 4-1.
Type each patch ID (one at a time, and without the dash number) in the Enter
Patch ID box and click Find Patch.
5. Follow the instructions in the patch README to install each patch. The
patches must be installed in the order shown.
6. Reboot your system after installing all the patches.
TABLE 4-1Sun Solaris 8 and 9 Patches
Patch TypeSolaris 8 Patch NumberSolaris 9 Patch Number
fctl/fp/fcp111095-25113040-17
fcip111096-13113041-10
qlc111097-20113042-13
MPxIO111412-18113039-12
luxadm111413-18113043-12
cfgadm111846-08113044-05
FCSM driver114475-05114476-06
SUNWsan111847-08111847-08
FC HBA API Lib113766-04114477-03
SNIA FC HBA Lib113767-08114478-07
JNI FC HBA114877-10114878-10
Emulex FC HBA119913-07119914-07
Chapter 4 Software Installation27
Downloading HBA Driver Packages and Patches
for Solaris 10 for SPARC or x64/x86
There is no install_it script available to install the drivers for Solaris 10. If you are
using the Sun Solaris OS 10 01/06 or a later release, only the patch is required.
Otherwise, you must first install the packages and then the patch.
Note – The packages and patches must be installed in the order given.
▼ To Download the Packages
Perform the following steps to download the Solaris 10 packages.
1. Go to http://www.sun.com/download/products.xml?id=42c4317d.
The Products Download page displays.
2. Under Platform, click Download.
The Login menu displays.
3. Type your User Name and Password and click Login.
The Download page displays with two items available in the table.
DescriptionFile Name
Solaris 10 Sun StorEdge Enterprise 4Gb FC Single and
Dual Port HBA, English
Sun StorEdge Enterprise 4 Gb FC Single and Dual Port
Host Adapter README file, English
s10_emlxs_pkgs.tar.Z
README_s10_emlxs_pkgs.txt
4. Read the license agreement and accept or decline.
5. Click the download item that is appropriate for this 4-Gbit adapter.
The following packages are contained in the zipped file:
■ SUNWemlxs
■ SUNWemlxu
6. Click the second item and print the driver README installation instructions.
7. Follow the README instructions.
28Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
▼ To Download the Patches
Perform the following steps to download the Solaris 10 patches.
1. Go to http://sunsolve.sun.com.
The SunSolve Online license agreement page displays.
2. Accept the License Agreement.
The SunSolve Online page displays.
3. Under Patches and Updates, click PatchFinder.
4. Download one of the following patches by typing the patch ID (without the
dash number) in the Enter Patch ID box and click Find Patch.
■ 120222-08 (or above) Sun OS 5.10: Emulex-Sun Fibre LightPulse Channel Adapter
driver
■ 120223-08 (or above) Sun OS 5.10_x86: Emulex-Sun Fibre LightPulse Channel
Adapter driver
5. Follow the instructions in the patch README to install the patch.
6. Reboot your system after installing the patch.
Diagnostic Support
Diagnostic support for the Sun StorageTek Enterprise PCI-X 4 Gb FC Single and
Dual Port Emulex HBAs is available with SunVTS™ software, and the required
patches are listed in
TABLE 4-2Required Patches
Operating SystemSunVTS VersionPatch Number
Solaris 8 for SPARC5.1121422-01
Solaris 9 for SPARC5.1121422-01
Solaris 10 for SPARC6.0119838-03
Solaris 10 for SPARC6.1None required
Solaris 10 for x64/x866.0119839-03
Solaris 10 for x64/x866.1None required
TABLE 4-2.
Chapter 4 Software Installation29
Installing the HBA Driver With Red Hat
and SuSE Operating Systems
The Red Hat Enterprise Linux (RHEL) 3 and 4 and the SuSE Linux Enterprise Server
(SLES) 8 and 9 operating systems are supported on the single and dual port HBAs.
Before installing the drivers for Linux, you must have the relevant Linux OS
installed on your hard disk. The driver and utilities are available for download at
the Emulex web page dedicated to Sun products, the driver as a .gz package and
the utilities as a .tar file. The installation documentation is available from the same
web page as the driver and utilities.
▼ To Download and Install the Packages
Perform the following steps to download the packages.
1. Go to http://www.emulex.com/ts/docoem/Sun/10k.htm.
The Emulex main download page for Sun StorageTek Fibre Channel Host Bus
Adapters is displayed.
2. Click the SG-XPCI1FC-EM4-Z and SG-XPCI2FC-EM4-Z Host Adapters link.
The Emulex Sun StorageTek SG-XPCI1FC-EM4-Z and SG-XPCI2FC-EM4-Z Host
Adapters web page is displayed.
3. In the Latest Released Driver for Linux - 2.4 or 2.6 Kernel section, click the
download link for the Driver kit.
4. Click the Download link for the Application kit.
5. For the Complete Manual, click the Manual link to open the Emulex driver and
utilities for Linux.
6. Follow the instructions in the manual to install the HBA driver and the
Application Helper Module Kit.
Note – To create a Linux boot disk, see “Creating a Linux Boot Disk” on page 31.
30Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Red Hat and SuSE OS Diagnostic Support
Diagnostic support is provided by the Emulex lputil and HBAnyware utilities.
They support the following functions:
■ List adapters
■ Adapter information
■ Firmware maintenance
■ Reset adapters
To verify the installation, follow the instructions provided in the “View HBA
Information using lputil” section of the Emulex Driver manual.
Creating a Linux Boot Disk
Emulex adapters enable you to load and boot the Linux operating system from a
SAN-attached drive. You can use either the Emulex driver for Linux provided on
your Linux distribution CD or, if you are using a different Linux driver, create a
driver disk.
To boot from SAN directly using your distribution CD, follow the directions
included with that CD. Refer to the Emulex web site for additional requirements to
boot from a SAN.
Chapter 4 Software Installation31
Installing the HBA Driver With
Windows 2000 or Windows Server 2003
Operating Systems
The Windows 2000 and Windows Server 2003 operating systems are supported on
the single and dual port HBAs. Before installing the drivers for Windows, you must
have the relevant Windows OS installed on your hard disk. The driver kit, which
includes utilities, is available for download as a self-extracting .exe file at the
Emulex web page dedicated to Sun products. The installation documentation is
available from the same page as the driver kit.
The SCSIport Miniport driver supports the 32-bit Windows 2000 and Windows
Server 2003 only. The Storport Miniport driver can run on 32-bit and 64-bit Windows
Server 2003.
▼ To Install the HBA Driver
Follow these steps to download and install the Windows HBA Driver Kit.
1. Go to http://www.emulex.com/ts/docoem/Sun/10k.htm.
The Emulex main download page for Sun StorageTek Fibre Channel Host Bus
Adapters is displayed.
2. Click the SG-XPCI1FC-EM4-Z and SG-XPCI2FC-EM4-Z Host Adapters link.
The Emulex Sun StorageTek SG-XPCI1FC-EM4-Z and SG-XPCI2FC-EM4-Z Host
Adapters web page is displayed.
3. In the Latest Released Driver for Windows section, under Windows Server
2003 and Windows Server 2000, click the download link for the driver kit.
4. For the Complete Manual, click the Manual link to open the Emulex Storport
Miniport Driver or SCSIport Miniport driver.
5. Follow the instructions in the manual to install the HBA driver.
Note – To create a Windows boot disk, see “To Create a Windows Boot Disk” on
page 33.
32Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
▼ To Install the Diagnostic and Management
Utilities
Diagnostic support is provided by the Emulex lputil and HBAnyware utilities.
They support the following functions:
■ List adapters
■ Adapter information
■ Firmware maintenance
■ Reset adapters
To verify the installation, follow the instructions provided in the “View HBA
Information using lputil” section of the Emulex Driver manual.
▼ To Create a Windows Boot Disk
1. Go to http://www.emulex.com/ts/docoem/framsun/10k.htm.
The Emulex main download page for Sun StorageTek Fibre Channel Host Bus
Adapters is displayed.
2. Click the SG-XPCI1FC-EM4-Z and SG-XPCI2FC-EM4-Z Host Adapters link.
The Emulex Sun StorageTek SG-XPCI1FC-EM4-Z and SG-XPCI2FC-EM4-Z Host
Adapters web page is displayed.
3. For the manual, click the Manual link to open the Emulex Universal Boot
Version 5.01a9 user manual.
4. Follow the instructions in the manual to create a Windows boot disk.
Service Contact Information
If you need help installing or using this product, call 1-800-USA-4SUN, or go to:
http://www.sun.com/service/contacting/
Chapter 4 Software Installation33
34Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
APPENDIX
A
Declaration of Conformity,
Regulatory Compliance, and Safety
Statements
This appendix contains the following information that applies to the Sun StorageTek
Enterprise 4 Gb Fibre Channel Single and Dual Port Host Bus Adapter:
■ “Declaration of Conformity” on page 37
■ “Regulatory Compliance Statements” on page 39
■ “Safety Agency Compliance Statement” on page 43
35
36Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Declaration of Conformity
Compliance Model Number:LP-XXXXX
Product Family Name:Sun StorageTek Enterprise PCI-X 4 Gb Fibre Channel Single and Dual Port Emulex HBA
EMC
USA—FCC Class A
This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This equipment may not cause harmful interference.
2. This equipment must accept any interference that may cause undesired operation.
European Union
This equipment complies with the following requirements of the EMC Directive 89/336/EEC:
As Telecommunication Network Equipment (TNE) in Both Telecom Centers and Other Than Telecom Centers per (as applicable):
EN 300 386 V.1.3.2 (2003-05) Required Limits:
EN 55022:1994 +A1:1995 +A2:1997 ClassA
EN 61000-3-2:2000Pass
EN 61000-3-3:1995 +A1:2000Pass
IEC 61000-4-26 kV (Direct), 8 kV (Air)
IEC 61000-4-33 V/m 80-1000MHz, 10 V/m 800-960 MHz, and 1400-2000 MHz
IEC 61000-4-41 kV AC and DC Power Lines, 0.5 kV Signal Lines
IEC 61000-4-52 kV AC Line-Gnd, 1 kV AC Line-Line and Outdoor Signal Lines, 0.5 kV Indoor signal Lines > 10m.
IEC 61000-4-63 V
IEC 61000-4-11Pass
As Information Technology Equipment (ITE) Class A per (as applicable):
EN 55022:1994 +A1:1995 +A2:1997 Class A
EN 61000-3-2:2000Pass
EN 61000-3-3:1995 +A1:2000Pass
EN 55024:1998 +A1:2001 +A2:2003 Required Limits:
IEC 61000-4-24 kV (Direct), 8 kV (Air)
IEC 61000-4-33 V/m
IEC 61000-4-41 kV AC Power Lines, 0.5 kV Signal and DC Power Lines
IEC 61000-4-51 kV AC Line-Line and Outdoor Signal Lines, 2 kV AC Line-Gnd, 0.5 kV DC Power Lines
IEC 61000-4-63 V
IEC 61000-4-81 A/m
IEC 61000-4-11Pass
(SG-XPCI1FC-EM4-Z, SG-XPCI2FC-EM4-Z)
Safety: This equipment complies with the following requirements of the Low Voltage Directive 73/23/EEC:
EC Type Examination Certificates:
EN 60950-1:2001, 1st Edition, +A11TÜV Rheinland Certificate No. R 72050152
IEC 60950-1:2001, 1st EditionCB Scheme Certificate No. US/7598C/UL
Evaluated to all CB Countries
UL 60950-1:2003, 1st Edition, CSA C22.2 No. 60950-1-03File: E133173-A1-UL-1
Supplementary Information: This product was tested and complies with all the requirements for the CE Mark. This
equipment complies with the Restriction of Hazardous Substances (RoHS) directive 2002/95/EC.
37
/S//S/
Dennis P. SymanskiDATE
Worldwide, Compliance Engineering
Sun Microsystems, Inc.
4150 Network Circle, MPK15-102
Santa Clara, CA 95054 U.S.A.
Tel: 650-786-3255
Fax: 650-786-3723
Donald CameronDATE
Program Manager/Customer Quality
Sun Microsystems Scotland, Limited
Blackness Road, Phase I, Main Bldg.
Springfield, EH49 7LR
Scotland, United Kingdom
Tel: +44 1 506 672 539Fax: +44 1 506 670 011
38Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Regulatory Compliance Statements
Your Sun product is marked to indicate its compliance class:
• Federal Communications Commission (FCC) — USA
• Industry Canada Equipment Standard for Digital Equipment (ICES-003) — Canada
• Voluntary Control Council for Interference (VCCI) — Japan
• Bureau of Standards Metrology and Inspection (BSMI) — Taiwan
Please read the appropriate section that corresponds to the marking on your Sun product before attempting to install the
product.
FCC Class A Notice
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if it is
not installed and used in accordance withthe instruction manual, it may cause harmfulinterference to radio communications.
Operation of this equipment in a residential area islikely to cause harmfulinterference, in which case the user willbe required
to correct the interference at his own expense.
Modifications: Anymodifications made tothis device thatare notapproved by Sun Microsystems, Inc. may voidthe authority
granted to the user by the FCC to operate this equipment.
FCC Class A Parts
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception,which can be determined by turning theequipment off andon, the user is encouraged to try tocorrect the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/television technician for help.
Modifications: Anymodifications made tothis device thatare notapproved by Sun Microsystems, Inc. may voidthe authority
granted to the user by the FCC to operate this equipment.
39
ICES-003 Class A Notice - Avis NMB-003, Classe A
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
ICES-003 Class A Notice - Avis NMB-003, Classe A Parts
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
40Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
BSMI Class A Notice
The following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliance
label.
D33012
GOST-R CertificationMark
Regulatory Compliance Statements41
42Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Safety Agency Compliance
Statement
Read this section before beginning any procedure. The
following text provides safety precautions to follow when
installing a Sun Microsystems product.
Safety Precautions
For your protection, observe the following safety
precautions when setting up your equipment:
■ Follow all cautions and instructions marked on the
equipment.
■ Ensure that the voltage and frequency of your power
source match the voltage and frequency inscribed on
the equipment’s electrical rating label.
■ Never push objects of any kind through openings in
the equipment. Dangerous voltages may be present.
Conductive foreign objects could produce a short
circuit that could cause fire, electric shock, or damage
to your equipment.
Symbols
The following symbols may appear in this book:
Caution – There is a risk of personal injury
and equipment damage. Follow the
instructions.
Depending on the type of power switch your device has,
one of the following symbols may be used:
On – Applies AC power to the system.
Off – Removes AC power from the system.
Standby – The On/Standby switch is in the
standby position.
Modifications to Equipment
Do not make mechanical or electrical modifications to the
equipment. Sun Microsystems is not responsible for
regulatory compliance of a modified Sun product.
Placement of a Sun Product
Caution – Do not block or cover the openings
of your Sun product. Never place a Sun
product near a radiator or heat register.
Failure to follow these guidelines can cause
overheating and affect the reliability of your
Sun product.
Caution – Hot surface. Avoid contact.
Surfaces are hot and may cause personal
injury if touched.
Caution – Hazardous voltages are present. To
reduce the risk of electric shock and danger to
personal health, follow the instructions.
Noise Level
Declared noise emissions in accordance with ISO 9296,
A-weighted, operating and idling:
Measure and Environment
L
(1B = 10 dB)
wAd
at or below 25ºC8.0 B
at max ambient8.4 B
bystander
L
pAm
at or below 25ºC66 dB
at max ambient69 dB
SELV Compliance
Safety status of I/O connections comply to SELV
requirements.
43
Power Cord Connection
Caution – Sun products are designed to work
with power systems having a grounded
neutral (grounded return for DC-powered
products). To reduce the risk of electric shock,
do not plug Sun products into any other type
of power system. Contact your facilities
manager or a qualified electrician if you are
not sure what type of power is supplied to
your building.
Caution – Not all power cords have the same
current ratings. Do not use the power cord
provided with your equipment for any other
products or use. Household extension cords
do not have overload protection and are not
meant for use with computer systems. Do not
use household extension cords with your Sun
product.
The following caution applies only to devices with a
Standby power switch:
Caution – The power switch of this product
functions as a standby type device only. The
power cord serves as the primary disconnect
device for the system. Be sure to plug the
power cord into a grounded power outlet that
is nearby the system and is readily accessible.
Do not connect the power cord when the
power supply has been removed from the
system chassis.
Caution – For products with multiple power
cords, all power cords must be disconnected
to completely remove power from the system.
Battery Warning
Caution – There is danger of explosion if
batteries are mishandled or incorrectly
replaced. On systems with replaceable
batteries, replace only with the same
manufacturer and type or equivalent type
recommended by the manufacturer per the
instructions provided in the product service
manual. Do not disassemble batteries or
attempt to recharge them outside the system.
Do not dispose of batteries in fire. Dispose of
batteries properly in accordance with the
manufacturer’s instructions and local
regulations. Note that on Sun CPU boards,
there is a lithium battery molded into the realtime clock. These batteries are not customer
replaceable parts.
System Unit Cover
You must remove the cover of your Sun computer system
unit to add cards, memory, or internal storage devices. Be
sure toreplace thecover beforepowering on your computer
system.
Caution – Do not operate Sun products
without the cover in place. Failure to take this
precaution may result in personal injury and
system damage.
The followingcaution applies onlyto devices withmultiple
power cords:
44Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Rack System Warning
The following warnings apply to Racks and Rack Mounted
systems.
CD and DVD Devices
The following caution applies to CD, DVD, and other
optical devices.
Caution – For safety, equipment should
always be loaded from the bottom up. That is,
install the equipment that will be mounted in
the lowest part of the rack first, then the next
higher systems, etc.
Caution – To prevent the rack from tipping
during equipment installation, the anti-tilt bar
on the rack must be deployed.
Caution – To prevent extreme operating
temperature within the rack insure that the
maximum temperature does not exceed the
product’s ambient rated temperatures.
Caution – To prevent extreme operating
temperatures due to reduced airflow
consideration should be made to the amount
of air flow that is required for a safe operation
of the equipment.
Laser Compliance Notice
Sun products that use laser technologycomply with Class1
laser requirements.
Caution – Use of controls, adjustments, or the
performance of procedures other than those
specified herein may result in hazardous
radiation exposure.
Conformité aux normes de sécurité
Veuillez lire attentivement cette section avant de
commencer. Ce texte traite des mesures de sécurité qu’il
convient de prendre pour l’installation d’un produit Sun
Microsystems.
Mesures de sécurité
Pour votre sécurité, nous vous recommandons de suivre
scrupuleusement lesmesures desécurité ci-dessouslorsque
vous installez votre matériel:
■ Suivez tous les avertissements et toutes les
instructions inscrites sur le matériel.
■ Assurez-vous que la tension et la fréquence de votre
source d'alimentation correspondent à la tension et à
la fréquence indiquées sur l'étiquette de la tension
électrique nominale du matériel
■ N'introduisez jamais d'objets quels qu'ils soient dans
les ouvertures de l'équipement. Vous pourriez vous
trouver en présence de hautes tensions dangereuses.
Tout objet étranger conducteur risque de produire un
court-circuit pouvant présenter un risque d'incendie
ou de décharge électrique, ou susceptible
d'endommager le matériel.
Class 1 Laser Product
Luokan 1 Laserlaite
Klasse 1 Laser Apparat
Laser Klasse 1
Safety Agency Compliance Statement45
Symboles
Vous trouverez ci-dessous la signification des différents
symboles utilisés:
Attention – Vous risquez d'endommager le
matériel ou de vous blesser. Veuillez suivre les
instructions.
Attention – Surfaces brûlantes. Evitez tout
contact. Les surfaces sont brûlantes. Vous
risquez de vous blesser si vous les touchez.
Attention – Tensions dangereuses. Pour
réduire les risques de décharge électrique et
de danger physique, observez les consignes
indiquées.
Selon le type d'interrupteur marche/arrêt dont votre
appareil est équipé, l'un des symboles suivants sera utilisé:
Marche – Met le système sous tension
alternative.
Positionnement d’un produit Sun
Attention – Evitez d'obstruer ou de recouvrir
les orifices de votre produit Sun. N'installez
jamais un produit Sun près d'un radiateur ou
d'une source de chaleur. Si vous ne respectez
pas ces consignes, votre produit Sun risque de
surchauffer et son fonctionnement en sera
altéré.
Niveau de pression acoustique
Declared noise emissions in accordance with ISO 9296,
A-weighted, operating and idling:
Measure and Environment
L
(1B = 10 dB)
wAd
at or below 25ºC8.0 B
at max ambient8.4 B
bystander
L
pAm
at or below 25ºC66 dB
at max ambient69 dB
Arret – Met le système hors tension
alternative.
Veilleuse – L'interrupteur Marche/Veille est
sur la position de veille.
Modification du matériel
N'apportez aucune modification mécanique ou électrique
au matériel. Sun Microsystems décline toute responsabilité
quant à la non-conformité éventuelle d'un produit Sun
modifié.
46Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Conformité SELV
Le niveau de sécurité des connexions E/S est conforme aux
normes SELV.
Connexion du cordon d’alimentation
Attention – Les produits Sun sont conçus
pour fonctionner avec des systèmes
d'alimentation équipés d'un conducteur
neutre relié à la terre (conducteur neutre pour
produits alimentés en CC). Pour réduire les
risques de décharge électrique, ne branchez
jamais les produits Sun sur une source
d'alimentation d'un autre type. Contactez le
gérant de votre bâtiment ou un électricien
agréé si vous avez le moindre doute quant au
type d'alimentation fourni dans votre
bâtiment.
Attention – Tous les cordons d'alimentation
ne présentent pas les mêmes caractéristiques
électriques. Les cordons d'alimentation à
usage domestique ne sont pas protégés contre
les surtensions et ne sont pas conçus pour être
utilisés avec des ordinateurs. N'utilisez jamais
de cordon d'alimentation à usage domestique
avec les produits Sun.
L'avertissement suivant s'applique uniquement aux
systèmes équipés d'un interrupteur Veille:
Attention – L'interrupteur d'alimentation de
ce produit fonctionne uniquement comme un
dispositif de mise en veille. Le cordon
d'alimentation constitue le moyen principal de
déconnexion de l'alimentation pour le
système. Assurez-vous de le brancher dans
une prise d'alimentation mise à la terre près
du système et facile d'accès. Ne le branchez
pas lorsque l'alimentation électrique ne se
trouve pas dans le châssis du système.
L'avertissement suivant s'applique uniquement aux
systèmes équipés de plusieurs cordons d'alimentation:
Mise en garde relative aux batteries
Attention – Les batteries risquent d’exploser
en cas de manipulation maladroite ou de
remplacement incorrect. Pour les systèmes
dont les batteries sont remplaçables, effectuez
les remplacements uniquement selon le
modèle du fabricant ou un modèle équivalent
recommandé par le fabricant, conformément
aux instructions fournies dans le manuel de
service du système. N’essayez en aucun cas de
démonter les batteries, ni de les recharger hors
du système. Ne les jetez pas au feu. Mettez-les
au rebut selon les instructions du fabricant et
conformément à la législation locale en
vigueur. Notez que sur les cartes processeur
de Sun, une batterie au lithium a été moulée
dans l'horloge temps réel. Les batteries ne sont
pas des pièces remplaçables par le client.
Couvercle de l'unité
Pour ajouterdes cartes, dela mémoire oudes périphériques
de stockage internes, vous devez retirer le couvercle de
votre système Sun. Remettez le couvercle supérieur en
place avant de mettre votre système sous tension.
Attention – Pour mettre un système équipé de
plusieurs cordons d'alimentation hors tension,
il est nécessaire de débrancher tous les
cordons d'alimentation.
Attention – Ne mettez jamais des produits
Sun sous tension si leur couvercle supérieur
n'est pas mis en place. Si vous ne prenez pas
ces précautions, vous risquez de vous blesser
ou d'endommager le système.
Mise en garde relative au système en rack
La mise en garde suivante s'applique aux racks et aux
systèmes montés en rack.
Attention – Pour des raisons de sécurité, le
matériel doit toujours être chargé du bas vers
le haut. En d'autres termes, vous devez
installer, en premier, le matériel qui doit se
trouver dans la partie la plus inférieure du
rack, puis installer le matériel sur le niveau
suivant, etc.
Safety Agency Compliance Statement47
Attention – Afin d'éviter que le rack ne
penche pendant l'installation du matériel, tirez
la barre anti-basculement du rack.
Attention – Pour éviter des températures de
fonctionnement extrêmes dans le rack,
assurez-vous que la température maximale ne
dépasse pas la fourchette de températures
ambiantes du produit déterminée par le
fabricant.
Attention – Afin d'empêcher des
températures de fonctionnement extrêmes
provoquées par une aération insuffisante,
assurez-vous de fournir une aération
appropriée pour un fonctionnement du
matériel en toute sécurité
Einhaltung sicherheitsbehördlicher
Vorschriften
Lesen Sie vor dem Ausführen von Arbeiten diesen
Abschnitt. Im folgenden Text werden Sicherheitsvorkehrungen beschrieben, die Sie bei der Installation eines
Sun Microsystems-Produkts beachten müssen.
Sicherheitsvorkehrungen
Treffen Sie zu Ihrem eigenen Schutz bei der Installation des
Geräts die folgenden Sicherheitsvorkehrungen:
■ Beachten Sie alle auf den Geräten angebrachten
Warnhinweise und Anweisungen.
■ Stellen Sie sicher, dass Spannung und Frequenz der
Stromversorgung den Nennleistungen auf dem am
Gerät angebrachten Etikett entsprechen.
■ Führen Sie niemals Fremdobjekte in die Öffnungen
am Gerät ein. Es können gefährliche Spannungen
anliegen. Leitfähige Fremdobjekte können einen
Kurzschluss verursachen, der einen Brand, Stromschlag oder Geräteschaden herbeiführen kann.
Avis de conformité des appareils laser
Les produitsSun quifont appel auxtechnologies laserssont
conformes aux normes de la classe 1 en la matière.
Class 1 Laser Product
Luokan 1 Laserlaite
Klasse 1 Laser Apparat
Laser Klasse 1
Périphériques CD et DVD
L'avertissement suivant s'applique aux périphériques CD,
DVD et autres périphériques optiques:
Attention – L'utilisation de contrôles et de
réglages ou l'application de procédures autres
que ceux spécifiés dans le présent document
peuvent entraîner une exposition à des
radiations dangereuses.
Symbole
Die Symbole in diesem Handbuch haben folgende
Bedeutung:
Achtung – Gefahr von Verletzung und
Geräteschaden. Befolgen Sie die Anweisungen.
Achtung – Heiße Oberfläche. Nicht berühren,
da Verletzungsgefahr durch heiße Oberfläche
besteht.
Achtung – Gefährliche Spannungen. Befolgen
Sie die Anweisungen, um Stromschläge und
Verletzungen zu vermeiden.
48Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Je nach Netzschaltertyp an Ihrem Gerät kann eines der
folgenden Symbole verwendet werden:
Ein – Versorgt das System mit Wechselstrom.
Aus– Unterbricht die Wechselstromzufuhr
zum Gerät.
Wartezustand – Der Ein-/Standby-Netzschalter befindet sich in der Standby-Position.
Modifikationen des Geräts
Nehmen Sie keine elektrischen oder mechanischen
Gerätemodifikationen vor. Sun Microsystems ist für die
Einhaltung der Sicherheitsvorschriften von modifizierten
Sun-Produkten nicht haftbar.
Lautstärke
Declared noise emissions in accordance with ISO 9296,
A-weighted, operating and idling:
Measure and Environment
L
(1B = 10 dB)
wAd
at or below 25ºC8.0 B
at max ambient8.4 B
bystander
L
pAm
at or below 25ºC66 dB
at max ambient69 dB
SELV-Konformität
Der Sicherheitsstatus der E/A-Verbindungen entspricht
den SELV-Anforderungen.
Aufstellung von Sun-Geräten
Achtung – Geräteöffnungen Ihres SunProdukts dürfen nicht blockiert oder
abgedeckt werden. Sun-Geräte sollten niemals
in der Nähe von Heizkörpern oder Heißluftklappen aufgestellt werden. Die Nichtbeachtung dieser Richtlinien kann Überhitzung
verursachen und die Zuverlässigkeit Ihres
Sun-Geräts beeinträchtigen.
Anschluss des Netzkabels
Achtung – Sun-Geräte sind für
Stromversorgungssysteme mit einem
geerdeten neutralen Leiter (geerdeter
Rückleiter bei gleichstrombetriebenen
Geräten) ausgelegt. Um die Gefahr von
Stromschlägen zu vermeiden, schließen Sie
das Gerät niemals an andere Stromversorgungssysteme an. Wenden Sie sich an den
zuständigen Gebäudeverwalter oder an einen
qualifizierten Elektriker, wenn Sie nicht sicher
wissen, an welche Art von Stromversorgungssystem Ihr Gebäude angeschlossen ist.
Achtung – Nicht alle Netzkabel verfügen
über die gleichen Nennwerte. Herkömmliche,
im Haushalt verwendete Verlängerungskabel
besitzen keinen Überlastschutz und sind
daher für Computersysteme nicht geeignet.
Verwenden Sie bei Ihrem Sun-Produkt keine
Haushalts-Verlängerungskabel.
Safety Agency Compliance Statement49
Die folgende Warnung gilt nur für Geräte mit StandbyNetzschalter:
Achtung – Beim Netzschalter dieses Geräts
handelt es sich nur um einen Ein/StandbySchalter. Zum völligen Abtrennen des Systems
von der Stromversorgung dient hauptsächlich
das Netzkabel. Stellen Sie sicher, dass das
Netzkabel an eine frei zugängliche geerdete
Steckdose in der Nähe des Systems angeschlossen ist. Schließen Sie das Stromkabel
nicht an, wenn die Stromversorgung vom
Systemchassis entfernt wurde.
Die folgende Warnung gilt nur für Geräte mit mehreren
Netzkabeln:
Achtung – Bei Produkten mit mehreren Netzkabeln müssen alle Netzkabel abgetrennt werden, um das System völlig von der Stromversorgung zu trennen.
Warnung bezüglich Batterien
Achtung – Bei unsachgemäßer Handhabung
oder nicht fachgerechtem Austausch der
Batterien besteht Explosionsgefahr. Verwenden Sie bei Systemen mit austauschbaren
Batterien ausschließlich Ersatzbatterien
desselben Typs und Herstellers bzw. einen
entsprechenden, vom Hersteller gemäß den
Anweisungen im Service-Handbuch des
Produkts empfohlenen Batterietyp. Versuchen
Sie nicht, die Batterien auszubauen oder
außerhalb des Systems wiederaufzuladen.
Werfen Sie die Batterien nicht ins Feuer.
Entsorgen Sie die Batterien entsprechend den
Anweisungen des Herstellers und den vor Ort
geltenden Vorschriften. CPU-Karten von Sun
verfügen über eine Echtzeituhr mit integrierter Lithiumbatterie. Diese Batterie darf nur
von einem qualifizierten Servicetechniker ausgewechselt werden.
Gehäuseabdeckung
Sie müssen die Abdeckung Ihres Sun-Computersystems
entfernen, um Karten, Speicher oder interne Speichergeräte
hinzuzufügen. Bringen Sie vor dem Einschalten des
Systems die Gehäuseabdeckung wieder an.
Achtung – Nehmen Sie Sun-Geräte nicht ohne
Abdeckung in Betrieb. Die Nichtbeachtung
dieses Warnhinweises kann Verletzungen oder
Geräteschaden zur Folge haben.
Warnungen bezüglich in Racks eingebauter
Systeme
Die folgenden Warnungen gelten für Racks und in Racks
eingebaute Systeme:
Achtung – Aus Sicherheitsgründen sollten
sämtliche Geräte von unten nach oben in
Racks eingebaut werden. Installieren Sie also
zuerst die Geräte, die an der untersten
Position im Rack eingebaut werden, gefolgt
von den Systemen, die an nächsthöherer Stelle
eingebaut werden, usw.
Achtung – Verwenden Sie beim Einbau den
Kippschutz am Rack, um ein Umkippen zu
vermeiden.
Achtung – Um extreme Betriebstemperaturen
im Rack zu vermeiden, stellen Sie sicher, dass
die Maximaltemperatur die Nennleistung der
Umgebungstemperatur für das Produkt nicht
überschreitet
Achtung – Um extreme Betriebstemperaturen
durch verringerte Luftzirkulation zu vermeiden, sollte die für den sicheren Betrieb des
Geräts erforderliche Luftzirkulation eingesetzt
werden.
50Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Hinweis zur Laser-Konformität
Sun-Produkte, die die Laser-Technologie verwenden,
entsprechen den Laser-Anforderungen der Klasse 1.
Precaución – Existe el riesgo de que se
produzcan lesiones personales y daños en el
equipo. Siga las instrucciones.
Class 1 Laser Product
Luokan 1 Laserlaite
Klasse 1 Laser Apparat
Laser Klasse 1
CD- und DVD-Geräte
Die folgende Warnung gilt für CD-, DVD- und andere
optische Geräte:
Achtung – Die hier nicht aufgeführte
Verwendung von Steuerelementen,
Anpassungen oder Ausführung von
Vorgängen kann eine gefährliche
Strahlenbelastung verursachen.
Normativas de seguridad
Lea esta sección antes de realizar cualquier operación. En
ella seexplican las medidas de seguridad que debe tomar al
instalar un producto de Sun Microsystems.
Medidas de seguridad
Para su protección, tome las medidas de seguridad
siguientes durante la instalación del equipo:
■ Siga todos los avisos e instrucciones indicados en el
equipo.
■ Asegúrese de que el voltaje y frecuencia de la fuente
de alimentación coincidan con el voltaje y frecuencia
indicados en la etiqueta de clasificación eléctrica del
equipo.
■ No introduzca objetos de ningún tipo por las rejillas
del equipo, ya que puede quedar expuesto a voltajes
peligrosos. Los objetos conductores extraños pueden
producir cortocircuitos y, en consecuencia, incendios,
descargas eléctricas o daños en el equipo.
Símbolos
En este documento aparecen los siguientes símbolos:
Precaución – Superficie caliente. Evite todo
contacto. Las superficies están calientes y
pueden causar lesiones personales si se tocan.
Precaución – Voltaje peligroso. Para reducir
el riesgo de descargas eléctricas y lesiones
personales, siga las instrucciones.
En función del tipo de interruptor de alimentación del que
disponga el dispositivo, se utilizará uno de los símbolos
siguientes:
Encendido – Suministra alimentación de CA
al sistema.
Apagado – Corta la alimentación de CA del
sistema.
Espera – El interruptor de encendido/espera
está en la posición de espera.
Modificaciones en el equipo
No realicemodificaciones detipo mecániconi eléctrico enel
equipo. Sun Microsystems no se hace responsable del
cumplimiento de normativas en caso de que un producto
Sun se haya modificado.
Colocación de un producto Sun
Precaución – No obstruya ni tape las rejillas
del producto Sun. Nunca coloque un producto
Sun cerca de radiadores ni fuentes de calor. Si
no sigue estas indicaciones, el producto Sun
podría sobrecalentarse y la fiabilidad de su
funcionamiento se vería afectada.
Safety Agency Compliance Statement51
Nivel de ruido
Declared noise emissions in accordance with ISO 9296,
A-weighted, operating and idling:
La siguiente medida solamente se aplica a aquellos
dispositivos que dispongan de un interruptor de
alimentación de espera:
Measure and Environment
L
(1B = 10 dB)
wAd
at or below 25ºC8.0 B
at max ambient8.4 B
bystander
L
pAm
at or below 25ºC66 dB
at max ambient69 dB
Cumplimiento de la normativa para
instalaciones SELV
Las condiciones de seguridad de las conexiones de entrada
y salidacumplen losrequisitos para instalaciones SELV (del
inglés Safe Extra Low Voltage, voltaje bajo y seguro).
Conexión del cable de alimentación
Precaución – Los productos Sun se han
diseñado para funcionar con sistemas de
alimentación que cuenten con un conductor
neutro a tierra (con conexión a tierra de
regreso para los productos con alimentación
de CC). Para reducir el riesgo de descargas
eléctricas, no conecte ningún producto Sun a
otro tipo de sistema de alimentación. Póngase
en contacto con el encargado de las
instalaciones de su empresa o con un
electricista cualificado en caso de que no esté
seguro del tipo de alimentación del que se
dispone en el edificio.
Precaución – No todos los cables de
alimentación tienen la misma clasificación
eléctrica. Los alargadores de uso doméstico no
cuentan con protección frente a sobrecargas y
no están diseñados para su utilización con
sistemas informáticos. No utilice alargadores
de uso doméstico con el producto Sun.
Precaución – El interruptor de alimentación
de este producto funciona solamente como un
dispositivo de espera. El cable de alimentación
hace las veces de dispositivo de desconexión
principal del sistema. Asegúrese de que
conecta el cable de alimentación a una toma
de tierra situada cerca del sistema y de fácil
acceso. No conecte el cable de alimentación si
la unidad de alimentación no se encuentra en
el bastidor del sistema.
La siguiente medida solamente se aplica a aquellos
dispositivos que dispongan de varios cables de
alimentación:
Precaución – En los productos que cuentan
con varios cables de alimentación, debe
desconectar todos los cables de alimentación
para cortar por completo la alimentación
eléctrica del sistema.
Advertencia sobre las baterías
Precaución – Si las baterías no se manipulan
o reemplazan correctamente, se corre el riesgo
de que estallen. En los sistemas que cuentan
con baterías reemplazables, reemplácelas sólo
con baterías del mismo fabricante y el mismo
tipo, o un tipo equivalente recomendado por
el fabricante, de acuerdo con las instrucciones
descritas en el manual de servicio del
producto. No desmonte las baterías ni intente
recargarlas fuera del sistema. No intente
deshacerse de las baterías echándolas al fuego.
Deshágase de las baterías correctamente de
acuerdo con las instrucciones del fabricante y
las normas locales. Tenga en cuenta que en las
placas CPU de Sun, hay una batería de litio
incorporada en el reloj en tiempo real. Los
usuarios no deben reemplazar este tipo de
baterías.
52Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Cubierta de la unidad del sistema
Debe extraer la cubierta de la unidad del sistema
informático Sun para instalar tarjetas, memoria o
dispositivos de almacenamiento internos. Vuelva a colocar
la cubierta antes de encender el sistema informático.
la utilización de láser
Los productosSun queutilizan tecnologíaláser cumplenlos
requisitos establecidos para los productos láser de clase 1.
Precaución – No ponga en funcionamiento
los productos Sun que no tengan colocada la
cubierta. De lo contrario, puede sufrir lesiones
personales y ocasionar daños en el sistema.
Advertencia sobre el sistema en bastidor
Las advertencias siguientes se aplican a los sistemas
montados en bastidor y a los propios bastidores.
Precaución – Por seguridad, siempre deben
montarse los equipos de abajo arriba. A saber,
primero debe instalarse el equipo que se
situará en el bastidor inferior; a continuación,
el que se situará en el siguiente nivel, etc.
Precaución – Para evitar que el bastidor se
vuelque durante la instalación del equipo,
debe extenderse la barra antivolcado del
bastidor.
Precaución – Para evitar que se alcance una
temperatura de funcionamiento extrema en el
bastidor, asegúrese de que la temperatura
máxima no sea superior a la temperatura
ambiente establecida como adecuada para el
producto.
Class 1 Laser Product
Luokan 1 Laserlaite
Klasse 1 Laser Apparat
Laser Klasse 1
Dispositivos de CD y DVD
La siguiente medida se aplica a los dispositivos de CD y
DVD, así como a otros dispositivos ópticos:
Precaución – La utilización de controles,
ajustes o procedimientos distintos a los aquí
especificados puede dar lugar a niveles de
radiación peligrosos.
Nordic Lithium Battery Cautions
Norge
Advarsel – Litiumbatteri — Eksplosjonsfare.
Ved utskifting benyttes kun batteri som
anbefalt av apparatfabrikanten. Brukt batteri
returneres apparatleverandøren.
Sverige
Precaución – Para evitar que se alcance una
temperatura de funcionamiento extrema
debido a una circulación de aire reducida,
debe considerarse la magnitud de la
circulación de aire requerida para que el
equipo funcione de forma segura.
Aviso de cumplimiento de la normativa para
Varning – Explosionsfara vid felaktigt
batteribyte. Använd samma batterityp eller en
ekvivalent typ som rekommenderas av
apparattillverkaren. Kassera använt batteri
enligt fabrikantens instruktion.
Safety Agency Compliance Statement53
Danmark
Suomi
Advarsel! – Litiumbatteri — Eksplosionsfare
ved fejlagtig håndtering. Udskiftning må kun
ske med batteri af samme fabrikat og type.
Levér det brugte batteri tilbage til
leverandøren.
Varoitus – Paristo voi räjähtää, jos se on
virheellisesti asennettu. Vaihda paristo
ainoastaan laitevalmistajan suosittelemaan
tyyppiin. Hävitä käytetty paristo valmistajan
ohjeiden mukaisesti.
54Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.