Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Copyright 2007Sun Microsystems,Inc., 4150 NetworkCircle, SantaClara, California95054, U.S.A. Allrights reserved.
Sun Microsystems,Inc. hasintellectual propertyrights relating to technology thatis described in this document.In particular, andwithout
limitation, theseintellectual propertyrights may includeone ormore ofthe U.S. patentslisted athttp://www.sun.com/patentsand one or
more additionalpatents orpending patent applicationsin theU.S. and inother countries.
This documentand the product to whichit pertainsare distributedunder licenses restricting their use, copying, distribution,and
decompilation. Nopart of the product orof thisdocument may bereproduced in any formby any means without priorwritten authorizationof
Sun andits licensors, if any.
Third-party software, including font technology, iscopyrighted and licensedfrom Sunsuppliers.
Parts ofthe productmay be derivedfrom BerkeleyBSD systems,licensed from the University ofCalifornia. UNIX is a registered trademarkin
the U.S.and in other countries, exclusivelylicensed throughX/Open Company, Ltd.
Sun, Sun Microsystems,the Sunlogo, Java, AnswerBook2,docs.sun.com, SunStorageTek,Netra, Sun Blade, Sun Fire,Sun StorEdge,Sun VTS,
and Solarisare trademarksor registeredtrademarks of Sun Microsystems, Inc.in theU.S. and inother countries.
All SPARC trademarksare usedunder licenseand are trademarks or registered trademarksof SPARC International, Inc. in theU.S. andin other
countries. Productsbearing SPARC trademarksare basedupon an architecture developedby Sun Microsystems, Inc.
The OPENLOOK and Sun™ Graphical UserInterface was developed by SunMicrosystems, Inc.for its users and licensees. Sun acknowledges
the pioneeringefforts ofXerox inresearching anddeveloping the conceptof visualor graphical userinterfaces forthe computer industry.Sun
holds anon-exclusive license from Xeroxto the Xerox Graphical User Interface, whichlicense also covers Sun’s licenseeswho implement OPEN
LOOK GUIsand otherwise comply with Sun’swritten license agreements.
U.S. GovernmentRights—Commercial use.Government users are subject to the SunMicrosystems, Inc.standard licenseagreement and
applicable provisionsof theFAR and its supplements.
DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,
INCLUDING ANYIMPLIED WARRANTY OF MERCHANTABILITY, FITNESSFOR A PARTICULARPURPOSE OR NON-INFRINGEMENT,
ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
Copyright 2007Sun Microsystems,Inc., 4150 NetworkCircle, SantaClara, Californie95054, États-Unis. Tous droits réservés.
Sun Microsystems,Inc. possèdeles droitsde propriété intellectuels relatifs àla technologiedécrite dans cedocument. Enparticulier, et sans
limitation, cesdroits depropriété intellectuelspeuvent inclure un ou plusieursdes brevetsaméricains listés surle site
http://www.sun.com/patents, un oules plusieursbrevets supplémentairesainsi que les demandes debrevet enattente aux les États-Unis et
dans d’autrespays.
Ce documentet le produit auquel ilse rapportesont protégéspar un copyrightet distribuéssous licences, celles-cien restreignent l’utilisation,
la copie,la distribution, et la décompilation.Aucune partie de ce produitou documentne peut être reproduitesous aucune forme, par quelque
moyen quece soit, sans l’autorisation préalableet écrite de Sun etde sesbailleurs de licence,s’il yen a.
Tout logiciel tiers,sa technologierelative auxpolices de caractères, comprise, est protégé parun copyrightet licencié par des fournisseursde
Sun.
Des partiesde ce produit peuvent dériverdes systèmesBerkeley BSD licenciés par l’Universitéde Californie. UNIX est unemarque déposée
aux États-Uniset dans d’autres pays, licenciéeexclusivement parX/Open Company, Ltd.
Sun, SunMicrosystems, lelogo Sun, Java,AnswerBook2, docs.sun.com,Sun StorageTek, Netra,Sun Blade, SunFire, SunStorEdge, SunVTS, et
Solaris sontdes marquesde fabrique oudes marquesdéposées deSun Microsystems, Inc. aux États-Uniset dans d’autres pays.
Toutes les marques SPARC sontutilisées sous licence et sontdes marquesde fabrique ou des marquesdéposées deSPARCInternational, Inc.
aux États-Uniset dans d’autres pays. Lesproduits portantles marquesSPARCsont basés sur une architecture développée par Sun
Microsystems, Inc.
L’interfaceutilisateur graphiqueOPEN LOOK etSun™ aété développée parSun Microsystems,Inc. pourses utilisateurs etlicenciés. Sun
reconnaît lesefforts depionniers deXerox dans la recherche et le développementdu conceptdes interfaces utilisateurvisuelles ougraphiques
pour l’industrieinformatique. Sun détient une licensenon exclusive de Xerox surl’interface utilisateurgraphique Xerox,cette licence couvrant
également leslicenciés de Sun implémentant lesinterfaces utilisateur graphiques OPEN LOOKet seconforment en outre aux licences écrites de
Sun.
LA DOCUMENTATION EST FOURNIE "EN L’ÉTAT" ET TOUTES AUTRES CONDITIONS, DÉCLARATIONS ET GARANTIES EXPRESSES
OU TACITES SONT FORMELLEMENT EXCLUES DANS LA LIMITE DE LA LOI APPLICABLE, Y COMPRIS NOTAMMENT TOUTE
GARANTIE IMPLICITE RELATIVE À LA QUALITÉ MARCHANDE, À L’APTITUDE À UNE UTILISATION PARTICULIÈRE OU À
L’ABSENCE DE CONTREFAÇON.
Please
Recycle
Contents
Prefacexi
1.Product Overview1
Single and Dual Port HBA Features2
Minimum System Hardware Requirements3
Supported Operating Systems4
2.Supported System Configurations5
Basic Interoperability6
Host Platform Support6
Storage System Support7
Fibre Channel Switch Support7
Solaris 8, 9, and 10 Operating System Requirements8
Minimum Operating System Levels8
Red Hat Enterprise Linux and SuSE Linux Enterprise Server Operating System
Requirements9
Minimum OS Levels9
Windows 2000 and Windows Server 2003 Operating System Requirements10
Minimum OS Levels10
Known Issues and Bugs10
iii
3.Hardware Installation13
▼To Verify the Packaging Contents14
▼To Install the HBA Hardware14
▼To Attach the Optical Cable16
▼To Apply Power18
▼To Verify Proper Installation in SPARC Platforms19
▼To Verify the Attached Storage21
▼To Verify Proper Installation in x64 Based Systems22
Service Contact Information22
4.Software Installation23
Installing the HBA Driver With Solaris Operating Systems24
▼To Download Solaris Patch Clusters24
Downloading HBA Driver Packages and Patches for Solaris 8 and 9 for
SPARC24
▼To Run An install_it Script Installation25
▼To Do A Manual Installation26
Downloading HBA Driver Packages and Patches for Solaris 10 for SPARC or
x64/x8628
▼To Download the Packages28
▼To Download the Patches29
Diagnostic Support29
Installing the HBA Driver With Red Hat and SuSE Operating Systems30
▼To Download and Install the Packages30
Red Hat and SuSE OS Diagnostic Support31
Creating a Linux Boot Disk31
Installing the HBA Driver With Windows 2000 or Windows Server 2003 Operating
Systems32
▼To Install the HBA Driver32
▼To Install the Diagnostic and Management Utilities33
ivSun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-
▼To Create a Windows Boot Disk33
Service Contact Information33
A.Declaration of Conformity, Regulatory Compliance, and Safety Statements35
Declaration of Conformity37
Regulatory Compliance Statements39
Safety Agency Compliance Statement43
Contentsv
viSun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-
Figures
FIGURE 3-1Removing the Bracket Screws 15
FIGURE 3-2Installing the Single and Dual Port HBAs 16
FIGURE 3-3Attaching the Optical Cable 17
vii
viiiSun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-
Tables
TABLE 1-1Single and Dual Port HBA Features 2
TABLE 2-1Sun Solaris 8, 9, and 10; Red Hat Enterprise Linux and SuSE Enterprise Linux; and Windows
2000 and Windows Server 2003 Host Platform Support 6
TABLE 3-1Optical Cable Specifications 17
TABLE 3-2LED Indicator Status Definitions 18
TABLE 3-320
TABLE 3-421
TABLE 4-1Sun Solaris 8 and 9 Patches 27
TABLE 4-2Required Patches 29
ix
xSun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-
Preface
This manual describes how to install, configure, and test the Sun StorageTek™
Enterprise PCI-X 4 Gb Fibre Channel (FC) Single or Dual Port Emulex Host Bus
Adapter (HBA). This document is written for technicians, system administrators,
authorized service providers (ASPs), and users who have advanced experience
troubleshooting and replacing hardware. Additional Sun StorageTek Enterprise PCIX 4 Gb FC Single and Dual Port Emulex HBAs can be ordered from Sun
Microsystems by two marketing part numbers:
Number of PortsMarketing Part Number
SingleSG-XPCI1FC-EM4-Z
DualSG-XPCI2FC-EM4-Z
How This Document Is Organized
Chapter 1 provides an overview of the product.
Chapter 2 describes the operating systems, host platforms, switches, and storage
systems that support the HBAs.
Chapter 3 describes how to install the HBAs.
Chapter 4 describes how to download and install the HBA drivers and patches.
Appendix A provides the required product safety information.
xi
Using UNIX Commands
This document does not contain information about basic UNIX®commands and
procedures such as shutting down the system, booting the system, and configuring
devices. Refer to the following for this information:
■ Software documentation that you received with your system
■ Solaris™ Operating System documentation, which is at:
http://docs.sun.com
Shell Prompts
ShellPrompt
C shellmachine-name%
C shell superusermachine-name#
Bourne shell and Korn shell$
Bourne shell and Korn shell superuser#
xii Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Typographic Conventions
Typeface
AaBbCc123The names of commands, files,
AaBbCc123What you type, when contrasted
AaBbCc123Book titles, new words or terms,
* The settings on your browser might differ from these settings.
*
MeaningExamples
Edit your.login file.
and directories; on-screen
computer output
with on-screen computer output
words to be emphasized.
Replace command-line variables
with real names or values.
Use ls -a to list all files.
% You have mail.
su
%
Password:
Read Chapter 6 in the User’s Guide.
These are called class options.
Yo u must be superuser to do this.
To delete a file, type rm filename.
Related Documentation
The following documents are available at:
http://www.sun.com/products-nsolutions/hardware/docs/Network_Storage_Solutions/SAN/san_software/
index.html and http://docs.sun.com/app/docs/doc/819-0139.
TitlePart Number
Sun StorEdge SAN Foundation Software 4.4 Guide to Documentation817-3670-xx
Sun StorEdge SAN Foundation Software 4.4 Installation Guide817-3671-xx
Sun StorEdge SAN Foundation Software 4.4 Configuration Guide817-3672-xx
Sun StorEdge Traffic Manager Installation and Configuration Guide817-3674-xx
Sun StorEdge SAN Foundation Software 4.4.9 Release Notes817-5604-xx
Solaris Fibre Channel and Storage Multipathing Administration Guide
(contains Sun Solaris 10 Fibre Channel Operating System booting procedure)
817-0139-xx
Prefacexiii
Documentation, Support, and Training
Sun FunctionURL
Documentationhttp://www.sun.com/documentation/
Supporthttp://www.sun.com/support/
Traininghttp://www.sun.com/training/
Third-Party Web Sites
Sun is not responsible for the availability of third-party web sites mentioned in this
document. Sun does not endorse and is not responsible or liable for any content,
advertising, products, or other materials that are available on or through such sites
or resources. Sun will not be responsible or liable for any actual or alleged damage
or loss caused by or in connection with the use of or reliance on any such content,
goods, or services that are available on or through such sites or resources.
Sun Welcomes Your Comments
Sun is interested in improving its documentation and welcomes your comments and
suggestions. You can submit your comments by going to:
http://www.sun.com/hwdocs/feedback
Please include the title and part number of your document with your feedback:
Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation &
Interop Guide, part number 819-5532-12
xiv Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
CHAPTER
1
Product Overview
This chapter provides a basic overview of the Sun StorageTek Enterprise PCI-X 4 Gb
FC Single and Dual Port Emulex HBAs (henceforth referred to as single and dual portHBAs). It contains the following topics:
■ “Single and Dual Port HBA Features” on page 2
■ “Minimum System Hardware Requirements” on page 3
1
Single and Dual Port HBA Features
The single and dual port HBAs consist of a single-slot PCI-X 2.0 bus expansion
board that interfaces a 64-bit PCI bus to one or two Fibre Channel (FC) optical media
busses. The single and dual port HBAs support 32-bit and 64-bit PCI transfers as a
master bus during direct memory access (DMA) transfers and 16-bit transfers as a
slave during parallel input/output (PIO) operations, as well as PCI-X 1.0 and 2.0
transactions. The channels of the single and dual port HBAs can act as either
initiators or targets. In the dual-port HBA, the two channels operate independently
and each supports a separate bus that operates at 4.25 Gbits per second. The single
and dual port HBAs are also backward compatible with 2.125-Gbit-per-second and
1.0625-Gbit-per-second busses.
One or two Small Form Factor (SFF) optical transceivers are used to connect to the
external FC busses. One Helios FC Controller chip is used to support one or two
independent FC busses.
See
TABLE 1-1 for a list of the single and dual port HBA features.
TABLE 1-1Single and Dual Port HBA Features
FeatureDescription
PCI signaling environment3.3-V PCI busses as well as PCI-X 1.0 and 2.0 (mode 2).
Incompatible with 5.0-V PCI slots
PCI/PCI-X transfer rate (max)264 MB/sec burst rate (64 bit @ 33 MHz PCI).
528 MB/sec burst rate (64 bit @ 66 MHz PCI).
1064 MB/sec burst rate (64 bit @ 133 MHz PCI-X)
2128 MB/sec burst rate (64 bit @ 266 MHz PCI-X)
Number of FC bussesOne or two
Number of devices supported126 devices per FC loop
FC bus type (external)Fiber optic media, short wave, multimode fiber (400-M5
SN-S)
FC transfer rate400 MB/sec per loop maximum, half duplex
800 MB/sec per loop maximum, full duplex
FC interface chipEmulex Helios PCI-X to FC
RAM1.5 MB SRAM
Flash ROM2/4 MB Flash (2 MB per FC port; 4 MB total on dual-
port HBA) containing BIOS, firmware, and Sun FCode.
The flash is field programmable.
External connectorsOne or two LC duplex connectors, one per channel
2Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
TABLE 1-1Single and Dual Port HBA Features (Continued)
FeatureDescription
Maximum FC cable length1 Gbps: 500 meters using 50/125 µm core fiber
300 meters using 62.5/125 µm core fiber
2 Gbps: 300 meters using 50/125 µm core fiber
150 meters using 62.5/125 µm core fiber
4 Gbps: 150 meters using 50/125 µm core fiber
70 meters using 62.5/125 µm core fiber
LED indicators1 green and 1 yellow light-emitting diode (LED) per FC
channel as status indicators
Form FactorPCI Low Profile Form Factor (MD2) 6.600 in. x 2.536 in.
Minimum System Hardware
Requirements
Your system must have an available PCI or PCI-X 64-bit slot to support these single
and dual port HBAs.
This product uses +3.3V signaling only, and is incompatible with +5.0-V signaling
PCI slots.
Chapter 1 Product Overview3
Supported Operating Systems
You can use the single and dual port HBAs with the following operating systems:
■ Solaris 8, 9, and 10 Operating Systems
To use the single and dual port HBAs with these operating systems, you must use
the Sun driver as described in “Solaris 8, 9, and 10 Operating System
Requirements” on page 8.
■ Red Hat Enterprise Linux and SuSE Linux Enterprise Server Operating Systems
To use the single and dual port HBAs with these operating systems, you must use
the Emulex driver as described in “Red Hat Enterprise Linux and SuSE Linux
Enterprise Server Operating System Requirements” on page 9.
■ Windows 2000 and Windows Server 2003 Operating Systems
To use the single and dual port HBAs with this OS, you must use the Emulex
driver as described in “Windows 2000 and Windows Server 2003 Operating
System Requirements” on page 10.
4Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
CHAPTER
2
Supported System Configurations
This chapter describes the operating systems, host platforms, storage, and
infrastructure configurations that support the Sun StorageTek Enterprise PCI-X 4 Gb
FC Single and Dual Port Emulex HBAs (henceforth referred to as single and dual portHBAs). It contains the following topics:
■ “Basic Interoperability” on page 6
■ “Solaris 8, 9, and 10 Operating System Requirements” on page 8
■ “Red Hat Enterprise Linux and SuSE Linux Enterprise Server Operating System
Requirements” on page 9
■ “Windows 2000 and Windows Server 2003 Operating System Requirements” on
page 10
■ “Known Issues and Bugs” on page 10
5
Basic Interoperability
This section provides information about platform, storage, and switch compatibility
permitting a heterogeneous Fibre Channel network design with the single and dual
port HBAs. This section contains the following topics:
■ “Host Platform Support” on page 6
■ “Storage System Support” on page 7
■ “Fibre Channel Switch Support” on page 7
Host Platform Support
The single and dual port HBAs are supported by the platforms and operating
systems listed in
TABLE 2-1.
TABLE 2-1Sun Solaris 8, 9, and 10; Red Hat Enterprise Linux and SuSE Enterprise Linux;
and Windows 2000 and Windows Server 2003 Host Platform Support
PlatformSupported OS
Sun Blade™ 1000, 1500, 2000, and 2500
workstations
Sun Fire™ V210, V240, and V250 serversSun Solaris
Sun Fire V440 serverSun Solaris
Sun Fire V480, V490, V880, and V890 serversSun Solaris
Sun Fire V1280, and E2900 serversSun Solaris
Sun Fire 4800, 4810, and E4900 serversSun Solaris
Sun Fire 6800 and E6900 serversSun Solaris
Sun Fire 12K and E20K serversSun Solaris
Sun Fire 15K and E25K serversSun Solaris
Sun Fire 280R serverSun Solaris
Netra™ 20, 240, 440, 1280, and t1400/t1405
servers
Sun Fire T2000 serverSun Solaris
Sun Fire V20z and V40z serversSun Solaris, Linux, and Windows
Sun Fire X4100, X4200, and X4200 M2 serversSun Solaris, Linux, and Windows
Sun Solaris
Sun Solaris
6Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Storage System Support
The single and dual port HBAs support the storage systems are listed below.
■ Sun StorEdge™ 3510 and 3511 FC arrays
■ Sun StorEdge 6020, 6120, and 6320 arrays
■ Sun StorEdge 6130 array
■ Sun StorEdge 6920 system
■ Sun StorEdge L25 and L100 tape libraries
■ Sun StorEdge C4 tape library
■ Sun StorEdge L500 tape library
■ Sun StorEdge L180 and L700 tape libraries
■ Sun StorEdge L5500 and L8500 tape libraries
Fibre Channel Switch Support
The single and dual port HBAs support the Fibre Channel switches listed below.
■ QLogic SANbox 5200 2 Gb switch
■ Sun StorEdge Network 2 Gb switch
■ QLogic SANbox 5600 and 5602 Stackable 4 Gb FC Switches
■ Sun StorEdge Network 2 Gb Brocade SilkWorm 3200 and 3800 switches
■ Sun StorEdge Network 2 Gb Brocade SilkWorm 3250 and 3850 switches
■ Sun StorEdge Network 2 Gb Brocade SilkWorm 3900 switch
■ Sun StorEdge Network 2 Gb Brocade SilkWorm 12000 and 24000 Core Fabric
switches
■ Sun StorEdge Network 4 Gb Brocade SilkWorm 4100 switch
■ Sun StorEdge Network 4 Gb Brocade SilkWorm 48000 and 200E switches
■ Sun StorEdge Network 2 Gb McDATA Sphereon 4300 switch
■ Sun StorEdge Network 2 Gb McDATA Sphereon 4500 switch
■ Sun StorEdge Network 2 Gb McDATA Intrepid 6064 director
■ Sun StorEdge Network 2 Gb McDATA Intrepid 6140 director
Chapter 2 Supported System Configurations7
Loading...
+ 47 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.