Sun Microsystems Netra CT 410, Netra CT 810 User Manual

Page 1
Sun Microsystems, Inc. www.sun.com
Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Netra™CT Server
Hardware Upgrade Guide
Part No. 819-2745-10 February 2007, Revision A
Page 2
Please
Recycle
Copyright 2007Sun Microsystems,Inc., 4150 Network Circle, SantaClara, California95054, U.S.A. Allrights reserved. Sun Microsystems, Inc.has intellectual property rights relating to technologythat isdescribed in thisdocument. Inparticular, and without
limitation, theseintellectual propertyrights may include one ormore ofthe U.S. patentslisted athttp://www.sun.com/patentsand one or more additional patents orpending patent applications in theU.S. and in other countries.
This documentand the product to which it pertainsare distributedunder licenses restricting theiruse, copying,distribution, and decompilation. Nopart of the product or of thisdocument may be reproduced in any formby any means without priorwritten authorizationof Sun andits licensors, if any.
Third-party software, including fonttechnology, iscopyrighted andlicensed from Sun suppliers. Parts ofthe productmay be derived from BerkeleyBSD systems,licensed from the University ofCalifornia. UNIX is a registered trademark in
the U.S.and in other countries, exclusivelylicensed throughX/Open Company,Ltd. Sun, SunMicrosystems, theSun logo, Java, AnswerBook2, docs.sun.com,Netra, SunSolve, OpenBoot, and Solarisare trademarksor registered
trademarks ofSun Microsystems,Inc. in the U.S. andin other countries. All SPARCtrademarks areused under license and are trademarksor registeredtrademarks ofSPARCInternational, Inc. inthe U.S.and in other
countries. Products bearingSPARCtrademarks arebased upon an architecture developed by SunMicrosystems, Inc. The OPENLOOK and Sun™ Graphical UserInterface was developed by SunMicrosystems, Inc.for its users and licensees. Sun acknowledges
the pioneeringefforts ofXerox inresearching anddeveloping the conceptof visualor graphical user interfaces forthe computer industry.Sun holds anon-exclusive license from Xeroxto the Xerox GraphicalUser Interface,which license also covers Sun’slicensees who implement OPEN LOOK GUIsand otherwise comply with Sun’swritten license agreements.
U.S. GovernmentRights—Commercial use.Government users are subject tothe SunMicrosystems, Inc. standard license agreement and applicable provisions ofthe FAR and its supplements.
DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANYIMPLIED WARRANTY OFMERCHANTABILITY,FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
Copyright 2007Sun Microsystems,Inc., 4150 Network Circle, SantaClara, Californie95054, Etats-Unis. Tous droits réservés. Sun Microsystems, Inc.a les droits de propriété intellectuels relatants à latechnologie qui est décrit dansce document. En particulier,et sans la
limitation, cesdroits depropriété intellectuelspeuvent inclure un ou plusdes brevetsaméricains énumérés à http://www.sun.com/patents et un oules brevetsplus supplémentairesou les applicationsde breveten attente dans les Etats-Uniset dans les autres pays.
Ce produit oudocument est protégé par un copyright etdistribué avec des licences quien restreignentl’utilisation, la copie, la distribution,et la décompilation. Aucunepartie de ce produit ou document nepeut êtrereproduite sousaucune forme, par quelque moyenque ce soit, sans l’autorisation préalableet écrite de Sun etde ses bailleurs de licence,s’il yen a.
Le logicieldétenu par des tiers, etqui comprendla technologie relative aux policesde caractères,est protégépar un copyright et licenciépar des fournisseurs deSun.
Des partiesde ce produit pourrontêtre dérivées des systèmes BerkeleyBSD licenciés par l’Université deCalifornie. UNIX est une marque déposée auxEtats-Unis et dans d’autres pays et licenciéeexclusivement par X/Open Company, Ltd.
Sun, SunMicrosystems, lelogo Sun, Java, AnswerBook2, docs.sun.com,Netra, SunSolve, OpenBoot, et Solarissont des marques de fabrique ou des marques déposéesde Sun Microsystems, Inc. aux Etats-Unis etdans d’autrespays.
Toutes les marquesSPARCsont utilisées sous licence etsont desmarques de fabrique ou desmarques déposéesde SPARC International, Inc. aux Etats-Uniset dans d’autres pays. Les produits portantles marquesSPARCsont basés sur une architecture développée par Sun Microsystems, Inc.
L’interfaced’utilisation graphiqueOPEN LOOK etSun™ aété développée par Sun Microsystems,Inc. pourses utilisateurs etlicenciés. Sun reconnaît les efforts depionniers deXerox pour la recherche et le développementdu conceptdes interfaces d’utilisationvisuelle ougraphique pour l’industriede l’informatique. Sun détient unelicense non exclusive de Xerox surl’interface d’utilisationgraphique Xerox, cette licence couvrant égalementles licenciées de Sun quimettent en place l’interface d’utilisation graphiqueOPEN LOOK etqui enoutre se conforment aux licencesécrites de Sun.
LA DOCUMENTATION EST FOURNIE "EN L’ÉTAT" ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES, DANSLA MESUREAUTORISEE PAR LA LOI APPLICABLE, YCOMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE, A L’APTITUDE A UNE UTILISATION PARTICULIERE OU A L’ABSENCE DE CONTREFAÇON.
Page 3
iii
Contents
Preface xi
1. Planning Your Upgrade 1
Netra CP2500 Board Features 2
System Requirements 2
Firmware and Software Requirements 3
CPU Board Firmware Rules 3
Hardware Requirements 3
Host Requirements 4
Satellite Requirements 4
Optional Components 4
Power Supply Requirements 5
To Calculate the Power Supply Requirements 5
Power Required by Sun cPCI Components 5
Power Available to Slots 6
Configurations 7
CPU Role 7
Host Board 7
Satellite Board 7
Netra CT 810 Server Configurations 8
Page 4
iv Netra CT Server Upgrade Guide • February 2007
Netra CT 410 Server Configurations 8
2. Upgrading the Hardware 9
Preparing to Upgrade the Hardware 10
Upgrading the Hardware 10
Installing New Fan Trays 11
To Remove an Existing Fan Tray 11
To Install a New Fan Tray 15
Removing a Host or Satellite Board 18
To Remove a Board 20
Removing and Replacing the Rear Transition Module 24
To Upgrade a Rear Transition Module 25
Installing a Netra CP2500 Board 30
To Install a Netra CP2500 Board 30
Blocking Air From Open Slots 35
To Block Open Filler Panel Openings 36
Performing Diagnostics 36
To Perform Diagnostics 36
Configuring the Hardware 37
To Reset the Platform Name 37
To Configure the Board and RTM 38
To Configure Fan Trays and Power Supplies 38
Troubleshooting 39
3. Firmware and Software Upgrade Process 41
Preparing to Upgrade Software and Firmware 42
Upgrading the Firmware 42
To Determine Firmware Versions 42
To Obtain Newer Firmware Versions 43
Page 5
Contents v
To Update the OpenBoot PROM Firmware 43
To Update the Alarm Card Firmware 43
Upgrading the Solaris Operating System 44
To Determine Software Version 44
To Upgrade the Operating System 44
To Download and Install Patches 45
Validating the Upgrades 46
To Validate the Upgrades 46
Index 47
Page 6
vi Netra CT Server Upgrade Guide • February 2007
Page 7
vii
Tables
TABLE 1-1 Sun cPCI Component Power Requirements 5
TABLE 1-2 Netra CT 810 cPCI Slot Power Availability 6
TABLE 1-3 Netra CT 410 cPCI Slot Power Availability 6
TABLE 1-4 Netra CT 810 Server Configurations with Netra CP2500 Boards 8
TABLE 1-5 Netra CT 410 Server Configurations with Netra CP2500 Boards 8
Page 8
viii Netra CT Server Upgrade Guide • February 2007
Page 9
ix
Figures
FIGURE 2-1 System Status Panel Locations 12
FIGURE 2-2 Removing the System Status Panel (Netra CT 810 Server) 13
FIGURE 2-3 Removing the System Status Panel (Netra CT 410 Server) 13
FIGURE 2-4 Removing a Fan Tray from a Netra CT 810 Server 14
FIGURE 2-5 Removing a Fan Tray from a Netra CT 410 Server 15
FIGURE 2-6 Positioning the System Status Panel (Netra CT 810 Server) 16
FIGURE 2-7 Positioning the System Status Panel (Netra CT 410 Server) 16
FIGURE 2-8 LEDs on the System Status Panel (Netra CT 810 Server) 17
FIGURE 2-9 LEDs on the System Status Panel (Netra CT 410 Server) 17
FIGURE 2-10 Slots for Boards in a Netra CT 810 Server 19
FIGURE 2-11 Slots for Boards in a Netra CT 410 Server 20
FIGURE 2-12 Loosening the Ejection-Lever Captive Screws 22
FIGURE 2-13 LEDs on the System Status Panel (Netra CT 810 Server) 23
FIGURE 2-14 LEDs on the System Status Panel (Netra CT 410 Server) 23
FIGURE 2-15 Locating a Rear Transition Module in a Netra CT 810 Server (Top View) 24
FIGURE 2-16 Locating a Rear Transition Module in a Netra CT 410 Server (Top View) 25
FIGURE 2-17 S1301 DIP Switch Bank Location on the RTM-S (Component Side) 26
FIGURE 2-18 S1302 DIP Switch Bank Location on the RTM-S (Solder Side) 27
FIGURE 2-19 Aligning the Rear Transition Module with the Rear Cage Cutouts 28
FIGURE 2-20 Connectors on the Netra CP2500 Host Rear Transition Module (RTM-H) 29
Page 10
x Netra CT Server Upgrade Guide • February 2007
FIGURE 2-21 Aligning the Board with the Board Cage Cutouts 31
FIGURE 2-22 Tightening the Ejection Lever Captive Screws 32
FIGURE 2-23 Connectors on the Netra CP2140 Host CPU Board 34
FIGURE 2-24 Connectors on the Netra CP2500 Host CPU Board 35
Page 11
xi
Preface
This guide contains procedures and important information for upgrading a Netra™ CT 410 server or Netra™ CT 810 server with the new Netra™ CP2500 board. This guide provides high-level processes and procedures for replacing an operational:
Netra™ CP2140 cPCI host board and rear transition module
Netra™ CP2160 cPCI satellite board and rear transition module
If you want to use the Netra CP2500 board as a node processor in a third-party cPSB chassis, refer to the Netra CP2500 Board Installation and Technical Reference Manual.
If you want to add a Netra CP2500 board to a new system, refer to the Netra CT Server Service Manual. New systems have the required software and hardware preinstalled, and the Netra CP2500 board hardware is preconfigured. New systems are shipped with one Netra CP2500 board installed in the host slot.
Before You Read This Document
The intended reader of this guide is an experienced system administrator or service technician who has experience installing hardware—systems and components—and has used the Solaris™ Operating System (Solaris OS). The reader should be comfortable with LAN fundamentals and with networking concepts in general.
This guide assumes that you have read other documentation and marketing materials and have determined that the Netra CP2500 board is an appropriate upgrade for your systems.
Page 12
xii Netra CT Server Hardware Upgrade Guide • February 2007
How This Document Is Organized
Chapter 1 provides important information, including configurations and
limitations, for upgrading your systems. Before you upgrade your systems, read this chapter.
Chapter 3 describes how to upgrade the firmware and software in preparation for
installing a Netra CP2500 board in a Netra CT 410 or Netra CT 810 server.
Chapter 2 describes how to hot-swap hardware in a Netra CT 410 or Netra CT 810
server to support one or more Netra CP2500 boards.
Using UNIX Commands
This document is a high-level guide for upgrading existing systems and does not contain detailed information about basic UNIX
®
commands and procedures such as shutting down the system, booting the system, and configuring devices. Refer to the following for this information:
Software documentation that you received with your system
Solaris™ Operating System documentation, which is at:
http://docs.sun.com
Page 13
Preface xiii
Shell Prompts
Typographic Conventions
Shell Prompt
C shell machine-name%
C shell superuser machine-name#
Bourne shell and Korn shell $
Bourne shell and Korn shell superuser #
Typeface
*
* The settings on your browser might differ from these settings.
Meaning Examples
AaBbCc123 The names of commands, files,
and directories; on-screen computer output
Edit your.login file. Use ls -a to list all files. % You have mail.
AaBbCc123 What you type, when contrasted
with on-screen computer output
%
su
Password:
AaBbCc123 Book titles, new words or terms,
words to be emphasized. Replace command-line variables with real names or values.
Read Chapter 6 in the User’s Guide. These are called class options. You must be superuser to do this. To delete a file, type rm filename.
Page 14
xiv Netra CT Server Hardware Upgrade Guide • February 2007
Related Documentation
The documents listed as online are available at:
http://www.sun.com/products-n-solutions/hardware/docs/
Application Title Part Number Format Location
Installation Netra CT Server Release Notes 819-2739-xx PDF
HTML
Online
Installation Netra CT Server Installation Guide 819-2740-xx PDF
HTML
Online
Service Netra CT Server Service Manual 819-2741-xx PDF
HTML
Online
Introduction Netra CT Product Overview 819-2742-xx PDF
HTML
Online
System Admin
Netra CT Server System Administration Guide
819-2743-xx PDF
HTML
Online
Safety Netra CT Server Safety and Compliance
Manual
819-2746-xx PDF
HTML
Online
Installation Netra CP2500 Board Release Notes 819-1748-xx PDF
HTML
Online
Installation Netra CP2500 Board Installation and
Technical Reference Manual
819-1747-xx PDF
HTML
Online
Installation Netra CP2500 Board Programming Guide 819-1749-xx PDF
HTML
Online
Safety Netra CP2500 Board Safety and Compliance
Guide
819-1750-xx PDF
HTML
Online
Installation Netra CP2500 RTM Release Notes 819-1752-xx PDF
HTML
Online
Installation Netra CP2500 RTM Installation and
Reference Guide
819-1753-xx PDF
HTML
Online
Page 15
Preface xv
Documentation, Support, and Training
Third-Party Web Sites
Sun is not responsible for the availability of third-party web sites mentioned in this document. Sun does not endorse and is not responsible or liable for any content, advertising, products, or other materials that are available on or through such sites or resources. Sun will not be responsible or liable for any actual or alleged damage or loss caused by or in connection with the use of or reliance on any such content, goods, or services that are available on or through such sites or resources.
Sun Welcomes Your Comments
Sun is interested in improving its documentation and welcomes your comments and suggestions. You can submit your comments by going to:
http://www.sun.com/hwdocs/feedback
Please include the title and part number of your document with your feedback:
Netra CT Server Hardware Upgrade Guide, part number 819-2745-10
Sun Function URL Description
Documentation http://www.sun.com/documentation/ Download PDF and HTML documents,
and order printed documents
Support and Training
http://www.sun.com/supportraining/ Obtain technical support, download
patches, and learn about Sun courses
Page 16
xvi Netra CT Server Hardware Upgrade Guide • February 2007
Page 17
1
CHAPTER
1
Planning Your Upgrade
This chapter provides important information, including requirements, configurations, and limitations for upgrading your systems. Before you upgrade your systems, read this chapter.
This chapter contains the following topics:
“Netra CP2500 Board Features” on page 2
“System Requirements” on page 2
“Configurations” on page 7
Page 18
2 Netra CT Server Hardware Upgrade Guide • February 2007
Netra CP2500 Board Features
The Netra CP2500 board is the next-generation processor board for use in Netra CT 410/810 servers.
The Netra CP2500 board and the corresponding rear transition modules (RTMs) are compatible (will not cause damage) with installations of the Netra CP2140 board or Netra CP2160 board. Some features and functions of the Netra CP2500, however, are not available or usable in these installations. In addition to the board and RTM, other hardware upgrades are required to use the Netra CP2500 board.
The Netra CP2500 board is not designed to be a one-to-one feature-compatible hardware replacement for the host Netra CP2140 cPCI board or satellite Netra CP2160 cPCI board. Before replacing a host Netra CP2140 cPCI board or satellite Netra CP2160 cPCI board, compare the features to ensure that the Netra CP2500 board provides the features you want for your system.
The Netra CP2500 board software is fully feature-compatible with other boards when installed in a Netra 810 server or Netra 410 server chassis. All applications you currently run can be run in a server upgraded with the Netra CP2500 board. Software and firmware upgrades are necessary. For information about the software and firmware upgrades that are necessary, refer to Netra CT410/810 Server Release Notes (819-2739).
System Requirements
This section describes the minimum power-supply availability, firmware, software, and hardware requirements necessary to install a Netra CP2500 board in a system that has no other Netra CP2500 boards installed.
After upgrading the firmware and software, you can replace a host or satellite board with a Netra CP2500 board.
Caution – The maximum capacity of any Netra CT server is three Netra CP2500
boards; this maximum includes the host board. Do not install more than three Netra CP2500 boards, even in a Netra 810 server, which has additional slots.
Page 19
Chapter 1 Planning Your Upgrade 3
Firmware and Software Requirements
Regardless of whether your system replaces a Netra CP2140 board or Netra CP2160 board with a Netra CP2500 board, the same Solaris OS version is required.
The following software upgrades are necessary:
CPU and alarm card firmware
Solaris 9 OS
Solaris 9 OS patches
Optionally, you might want to include the Acceptable_Fru_Types configuration from the alarm card command line interface (CLI).
For instructions on upgrading the software and firmware, refer to Netra CT410/810 Server Release Notes (819-2739).
Note – Upgrade the hardware before upgrading the software and firmware.
CPU Board Firmware Rules
Different boards can be mixed within a Netra CT 410/810 system. However, a board might fail to function if the following rules are not followed:
The firmware on all boards in the systems must be at the same level.
If different versions of boards are used in a system, the firmware level for all must
be equal to or greater than the highest minimum required by any board in the system.
Hardware Requirements
Caution – The maximum number of Netra CP2500 boards that you can install on a
any Netra CT 410/810 system is three. Do not exceed this maximum.
The number of boards you can install could be fewer than three if your systems are customized or configured with third-party components. To support the maximum number of boards, your system must have enough power supply. To calculate power-supply requirements, see “Power Supply Requirements” on page 5.
Page 20
4 Netra CT Server Hardware Upgrade Guide • February 2007
Host Requirements
The following hardware components are required and included in the host upgrade kits, based on your server chassis:
Netra CP2500 board motherboard with 2 gigabytes of SDRAM memory
Netra CP2500 rear transition module (RTM-H)
High-speed fan trays
Note – The high-speed fan trays for the Netra CT 410 are different from the high-
speed fan trays for the Netra CT 810. When ordering host upgrade kits, be sure to order the correct kit to match your server.
Satellite Requirements
The following hardware components are required to install a satellite board:
Netra CP2500 board with 2 gigabytes of SDRAM memory
Netra CP2500 rear transition module (RTM-S)
High-speed fan trays, if fan trays have not been upgraded
Optional Components
After you upgrade your systems with a Netra CP2500 board and required components, you might want to add boards immediately or later to increase performance. After you have upgraded the required hardware components, you can add boards up to the maximum allowed. The following are the requirements for adding each board.
Netra CP2500 board with 2 gigabytes of SDRAM memory
Satellite Netra CP2500 RTM-S board
High-speed fan trays
Air-blocking filler panels
Note – Netra CP2500 host boards and rear transition modules for host boards
(RTM-H) are not provided as optional components because they are available in the host upgrade kits.
Page 21
Chapter 1 Planning Your Upgrade 5
Power Supply Requirements
For standard and supported configurations of the Netra 410/810 servers, the power supply is sufficient to accommodate up to three Netra CP2500 boards.
If your systems are customized or configured with third-party components, the number of boards you can install could be fewer than three, based upon the power supply. In this case, calculate your system’s power requirements to verify you have sufficient power for the number of boards you want to install in your system. Contact your original equipment manufacturer’s (OEM) customer support for information about their components.
To Calculate the Power Supply Requirements
1. Compute the total cPCI power requirements of your planned configuration.
TABLE 1-1 shows the power requirements of Sun components; use the manufacturer’s
peak power data for any third-party components. Make sure that you include all add-in components, such as memory configurations, PCI mezzanine card (PMC) add-on boards, and RTMs.
2. Compare your configuration’s power requirements with the power available in
TABLE 1-2 (Netra 810 server) or TABLE 1-3 (Netra 410 server).
If the required power for your configuration is less than the power available, your
configuration can be supported in the system.
If the required power for your configuration exceeds the power available, your
configuration cannot be supported. Modify the configuration.
Refer to the Netra CP2500 Board Installation and Technical Reference Manual for additional information about power requirements.
Power Required by Sun cPCI Components
The following table shows the power required for Sun-supplied cPCI components.
TABLE 1-1 Sun cPCI Component Power Requirements
cPCI Component 3.3 V 5.0 V +12 V -12 V Notes
CP2500 with 2GB memory 5.5 A 8.1 A 0.45 A -
CP2500 RTM-H - 1.7 A - -
CP2500 RTM-S - 1.0 A - -
PMC/PIM on CP2500 - 2.0 A - -
Page 22
6 Netra CT Server Hardware Upgrade Guide • February 2007
Power Available to Slots
Installed cPCI boards must not exceed the power available to the slots. TABLE 1-2 and
TABLE 1-3 show power availability for cPCI boards in Netra CT 810 servers and Netra
CT410 servers.
CP2140 + CPU Transistion Card (CTC)
3.4 A 3.0 A - -
CP2160 + RTM 3.4 A 3.0 A - -
PMC on CP2140 or CP2160 2.27 A 1.5 A - -
Ethernet/SCSI Adapter I/O board 1.5 A 1.5 A - - Estimate
PMC on CP2500 - 1.33 A - -
TABLE 1-2 Netra CT 810 cPCI Slot Power Availability
Power Measurement 3.3 V 5.0 V +12 V -12 V Notes
cPCI power available to all boards, excluding the alarm card
36 A 36 A 4.8 A 700 mA Total power requirements of cPCI
boards must not exceed this line
Per-slot constraints 12 A 22.6 A 1.2 A 100 mA Maximum current per slot
TABLE 1-3 Netra CT 410 cPCI Slot Power Availability
Power Measurement 3.3 V 5.0 V +12 V -12 V Notes
cPCI power available 18 A 36 A 4.8 A 400 mA Total power requirements of cPCI
boards must not exceed this line
Per-slot constraints 12 A 22.6 A 1.2 A 100 mA
TABLE 1-1 Sun cPCI Component Power Requirements (Continued)
cPCI Component 3.3 V 5.0 V +12 V -12 V Notes
Page 23
Chapter 1 Planning Your Upgrade 7
Configurations
This section describes supported configurations. Use the information in this section to determine which allowable configuration matches your system and upgrade needs.
Note – You can install up to three Netra CP2500 boards. This maximum is set due to
power-supply limitations. For more information, see “Power Supply Requirements”
on page 5.
CPU Role
The following sections describe the roles of the Netra CP2500 board when used as a host or a satellite CPU.
Host Board
When a Netra CP2500 board is in the host slot in a Netra CT 410 or Netra CT 810, it acts as the system host CPU. In this role, it is a performance upgrade for the Netra CP2140 host board. All applications that run on the Netra CP2140 board run on a Netra CP2500 host board.
As a host, the Netra CP2500 board manages local resources including the field­replacable units (FRUs) connected to the host’s own SCSI interfaces. With the alarm card, the host board acts as the hot-swap controller and manages the dynamic reconfiguration of the following FRUs on the cPCI bus:
Alarm card
Netra CP2160 board in a non-host I/O slot
Netra CP2500 board in the host slot and in a non-host slot
Nonintelligent cPCI I/O boards
Satellite Board
When a Netra CP2500 board is in a non-host slot, it acts as a satellite. In this role, it is a performance upgrade for the Netra CP2160 satellite board. The Netra CP2500 board can be managed by either a host Netra CP2140 or a host Netra CP2500 board. All applications that run on the Netra CP2160 run on a Netra CP2500.
Page 24
8 Netra CT Server Hardware Upgrade Guide • February 2007
Netra CT 810 Server Configurations
The Netra CT 810 server rear access is supported. You can install a maximum of three Netra CP2500 boards.
TABLE 1-4 lists the supported configurations.
For new Netra CT 810 servers ordered from Sun, one Netra CP2500 board is preinstalled in the host slot.
Caution – In the Netra CT 810, the Netra CP2500 board is not supported in slot 6 or
slot 7. This configuration results in higher operating temperatures that trigger equipment shut down.
Netra CT 410 Server Configurations
The Netra CT 410 server rear access (diskfull) is supported. You can install up to three Netra CP2500 boards.
TABLE 1-5 lists the supported configurations.
For new Netra CT 410 servers ordered from Sun, one Netra CP2500 board is preinstalled in the host slot.
TABLE 1-4 Netra CT 810 Server Configurations with Netra CP2500 Boards
Slot 1 (Host) Slots 2 through 5 Slots 6 and 7 Slot 8
CP2140 + CTC
or
CP2500 + RTM-H
CP2160 + RTM CP2160 + RTM
Alarm card
CP2500 + RTM-S
cPCI I/O board cPCI I/O board
TABLE 1-5 Netra CT 410 Server Configurations with Netra CP2500 Boards
Slots 1 and 2 Slot 3 (Host) Slot 4 Slot 5
Alarm card
CP2140 cPCI board + CTC
CP2160 + RTM CP2160 + RTM
or or or
CP2500 + RTM-H CP2500 + RTM-S CP2500 + RTM-S
Page 25
9
CHAPTER
2
Upgrading the Hardware
This chapter describes how to upgrade the hardware in a Netra CT 810/410 server to support one or more Netra CP2500 board boards.
This chapter contains the following topics:
“Preparing to Upgrade the Hardware” on page 10
“Upgrading the Hardware” on page 10
“Configuring the Hardware” on page 37
“Troubleshooting” on page 39
Page 26
10 Netra CT Server Hardware Upgrade Guide • February 2007
Preparing to Upgrade the Hardware
Before upgrading hardware, make sure the following steps are completed:
1. Make sure your system meets the minimum requirements, as detailed in
Chapter 1.
2. Obtain all of the required hardware; inspect the shipment to ensure all
components are present and undamaged.
3. Obtain or access online the following related documentation:
Netra CT Server Service Manual (819-2741)
Netra CP2500 Board Release Notes (819-1748)
Netra CP2500 Board Installation and Technical Reference Manual (819-1747)
Netra CP2500 RTM Release Notes (819-1752)
Netra CP2500 RTM Installation and Technical Reference Manual (819-1753)
Upgrading the Hardware
The following information provides instructions for upgrading hardware components to install new fan trays, to replace host Netra CP2140 boards and satellite Netra CP2160 boards with Netra CP2500 boards, and to replace the rear transition modules.
The following procedures assume that you are performing the upgrades in hot-swap mode. Be sure to observe the rules and restrictions for hot-swapping boards and their corresponding rear transition modules. For these. refer to the Netra CT Server Service Manual.
After you complete the hardware upgrades and replace a host or satellite board in a system with a Netra CP2500 board, you can install additional boards, up to the maximum per system, immediately or at a later date. To add Netra CP2500 boards to a system that has already been upgraded and can support additional Netra CP2500 boards, refer to the Netra CT Server Service Manual.
Caution – Installed boards must not exceed power available to the slots. If you have
a customized system that contains third-party components, see “Power Supply
Requirements” on page 5 for important information.
Page 27
Chapter 2 Upgrading the Hardware 11
For detailed instructions, including illustrations and safety precautions, refer to the following documentation:
Netra CP2140 Technical Reference and Installation Manual (816-4908)
Netra CP2160 Technical Reference and Installation Manual (816-5772)
Netra CP2500 Technical Reference and Installation Manual (819-1747)
Installing New Fan Trays
New high-speed fan trays are required to meet cooling requirements for Netra CP2500 boards. The fan trays for the Netra CT 810 are different from those required in the Netra CT 410. Make sure you install the correct trays in the corresponding server.
Caution – Do not use other fan trays with the Netra CP2500 board. Overheating can
cause the server to shut down, resulting in downtime.
If you are upgrading a host board to a Netra CP2500, the fan trays are included with the host upgrade kit.
To upgrade the fans, remove each existing fan tray and install each new high-speed fan tray individually as detailed in the following steps.
To Remove an Existing Fan Tray
1. Establish a connection and log in to the drawer alarm card.
2. To check the fan trays to determine if they were previously upgraded to accommodate Netra CP2500 boards, enter the showfru command at the alarm card CLI prompt.
where number is either number 1 or 2 fan tray and Sun-part number is the part number (FRU ID).
The new fan tray part numbers are as follows:
540-6419 for the Netra CT 810 servers
540-7115 for the Netra CT 410 servers
cli> showfru fan number Sun-part-number
Page 28
12 Netra CT Server Hardware Upgrade Guide • February 2007
If the correct high-speed fan tray part number displays, and the part numbers on the fan trays match, skip the procedures for upgrading the fan trays and continue with the steps in “Removing a Host or Satellite Board” on page 18.
3. Attach the antistatic wrist strap.
4. Go to the front of the Netra CT server and locate the system status panel.
The location of the system status panel in the Netra CT 810 server and Netra CT 410 server is illustrated in
FIGURE 2-1.
FIGURE 2-1 System Status Panel Locations
5. Using a No. 2 Phillips screwdriver, loosen the two captive screws that hold the system status panel in place.
FIGURE 2-2 shows the location of the captive screws on the Netra CT 810 server, and FIGURE 2-3 shows the location of the captive screws on the Netra CT 410 server.
HDD1
H O
T S W
A
P
COM 1 ENET 1 ENET 2
ALARM
COM 2
ALA
RM/USER
H O
T S W
A P
ET
H ERN
E T
READ
Y
C O
M
RESET
ABORT
m
i c r o s y s t
e m s
H
O T
S
W A
P
COM 1 ENET 1 ENET 2
ALARM
COM 2
HDD0
A
L A
R M
/ U S E
R
H
O T
S W
A P
E T
H E
R N E
T
R
E A
D Y
C O
M
R
E
S E
T
A B
O R
T
m
i c r o s y s t e m
s
H O T S W A
P
COM 1 ENET 1 ENET 2
ALARM
COM 2
HDD
0
A
L A
R M
/ U S E
R
H
O T
S W
A P
E T
HE
R N E
T
R
E A
D Y
C O
M
R
E
S E
T
A B
O R
T
m
i c r o s y s t e m
s
System status panel, Netra CT 410 servers
System status panels, Netra CT 810 server
Page 29
Chapter 2 Upgrading the Hardware 13
FIGURE 2-2 Removing the System Status Panel (Netra CT 810 Server)
FIGURE 2-3 Removing the System Status Panel (Netra CT 410 Server)
HDD1
HOT SWAP
COM 1 ENET 1 ENET 2
ALARM
COM 2
AL
A R
M/USE
R
HOTSWAP
ET
HERNE
T
R E
AD
Y
C
OM
RES
ET
ABORT
m ic
r os y s t e
m s
H O
T S W
A
P
COM 1 ENET 1 ENET 2
ALARM
COM 2
HDD0
ALAR
M/U
SE
R
HOTSWAP
E T
H ERN
E T
RE
AD
Y
CO
M
RES
E
T
ABO
RT
m
i c r o s y s
te m s
Page 30
14 Netra CT Server Hardware Upgrade Guide • February 2007
6. Pull the system status panel away from the Netra CT server and place it on the electrostatic discharge mat.
You might need to pull on the screws to remove the system status panel from the server.
Caution – Remove and replace one fan tray at a time, so that cooling is provided to
the server.
7. Remove the fan tray from the system.
If you are removing a fan tray from a Netra CT 810 server, squeeze on the tabs on
the sides of the fan tray handle to disengage the tray from the server (
FIGURE 2-4).
If you are removing a fan tray from a Netra CT 410 server, pull on the fan tray
handle to disengage the tray from the server (
FIGURE 2-5).
FIGURE 2-4 Removing a Fan Tray from a Netra CT 810 Server
HOT SWAP
COM 1 ENET 1 ENET 2COM 2
HOTSWAP
CO
M
m i c r
o s y s t
e m s
1
1
2
Page 31
Chapter 2 Upgrading the Hardware 15
FIGURE 2-5 Removing a Fan Tray from a Netra CT 410 Server
To Install a New Fan Tray
1. Insert the fan tray into the system:
If you are installing a fan tray into a Netra CT 810 server, press the fan tray into
place until it clicks into place (
FIGURE 2-4).
If you are installing a fan tray into a Netra CT 410 server, make sure the handle
on the fan tray is is flush against the fan tray, and press the fan tray handle to lock the tray into place (
FIGURE 2-5).
2. Carefully position the system status panel into place on the system.
FIGURE 2-6 shows how to position the panel into place on the Netra CT 810 server
and
FIGURE 2-7 shows how to position the panel into place on the Netra CT 410
server.
HOT SWAP
COM 1 ENET 1 ENE
T
ALARM
COM 2
HOTSWAP
E
TH
E
R
NE
T
C
OM
m
i c ros
y s
te ms
HOT SWAP
COM 1 ENET 1 ENE
T
ALARM
COM 2
HOTSWAP
ETH
ERNE
T
C
O
M
m
icr os
y s te
m s
Page 32
16 Netra CT Server Hardware Upgrade Guide • February 2007
FIGURE 2-6 Positioning the System Status Panel (Netra CT 810 Server)
FIGURE 2-7 Positioning the System Status Panel (Netra CT 410 Server)
3. Push the system status panel into place against the server, paying special attention to the connector on the left side of the panel, making sure that the connector on the left rear of the system status panel mates fully with the system controller board.
H
D
D
1
HOT SWAP
COM 1 ENET 1 ENET 2
ALARM
COM 2
ALA
RM
/U
S E
R
HOTSWAP
E
T H E
RN
ET
RE
A D Y
CO
M
R
E S E
T
A
B O
RT
m ic r o s y
s t e m
s
HDD0
H O
T
SW
AP
COM 1 ENET 1 ENET 2
ALARM
COM 2
HDD0
ALARM/USER
HO
TSW
A P
ETHERNET
READY
COM
RESET
ABORT
m i c r o s y s t
e m s
Page 33
Chapter 2 Upgrading the Hardware 17
Note – Be careful not to press the power switch when you are pressing the left side
of the system status panel into place.
4. Using a No. 2 Phillips screwdriver, tighten the two captive screws to secure the system status panel to the system.
FIGURE 2-2 shows the location of the captive screws on the Netra CT 810 server, and FIGURE 2-3 shows the location of the captive screws on the Netra CT 410 server.
5. Verify that the fan tray LEDs are lit properly.
FIGURE 2-8 shows the locations of the fan tray LEDs on the Netra CT 810 server and FIGURE 2-9 shows the locations of the fan tray LEDs on the Netra CT 410 server.
A fan tray is functioning properly if the amber Fault LED ( ) on the system status panel is OFF and the green Power LED ( ) is ON.
FIGURE 2-8 LEDs on the System Status Panel (Netra CT 810 Server)
FIGURE 2-9 LEDs on the System Status Panel (Netra CT 410 Server)
Page 34
18 Netra CT Server Hardware Upgrade Guide • February 2007
Removing a Host or Satellite Board
If you are upgrading a host board and one or more satellite boards on the same system, perform the procedures first on the host board, then repeat the procedures for the satellite boards.
Caution – If a Netra CP2140 board is being used as host and not functioning as an
I/O board, it cannot be hot-swapped.
Note – Only remove the existing board at this time; do not install the new board
until after you install the new rear transition module.
FIGURE 2-10 shows the locations of boards in the Netra CT 810 server. FIGURE 2-11
shows the locations of boards in the Netra CT 410 server.
Page 35
Chapter 2 Upgrading the Hardware 19
FIGURE 2-10 Slots for Boards in a Netra CT 810 Server
HOT SWAP
COM 1 ENET 1 ENET 2 ALARMCOM 2
ALARM/USER
HOTSWAP
ETHERNET
READY
COM
RESET
ABORT
microsystems
Host CPU board
Alarm card
Slots for I/O boards or satellite CPU boards
Page 36
20 Netra CT Server Hardware Upgrade Guide • February 2007
FIGURE 2-11 Slots for Boards in a Netra CT 410 Server
To Remove a Board
1. Locate the board that you want to remove from the server.
2. Log in to the Netra CT server.
HOT SWAP
COM 1 ENET 1 ENET 2
ALARM
COM 2
HDD0
ALARM/USER
HOTSWAP
ETHERNET
READY
COM
RESET
ABORT
microsystems
Host CPU board
CPU front termination board
Alarm card
Slots for I/O boards or satellite CPU boards
Page 37
Chapter 2 Upgrading the Hardware 21
3. Determine the hot-swap state for the slot that holds the board you are about to remove.
To determine the current hot-swap state for the slots in your server, as superuser, enter:
If in the output you see value ‘basic’ following the default-hotswap-mode
line, then all of the slots in the Netra CT server have been set to basic hot-swap. You should see value ’disabled’ for every slot in the system in this situation. Go to Step 4 to manually disconnect the board before removing it.
If in the output you see value ’full’ following the default-hotswap-mode
line, then at least one of the slots in the Netra CT server has been set to full hot­swap. You must look at the entries for individual slots to determine if they have been set to basic or full hot-swap mode in this situation:
If you see value ’enabled’ following a <slot#-autoconfig> line, then
that slot is set to full hot-swap. Skip to Step 6 to remove the board.
If you see value ’disabled’ following a <slot#-autoconfig> line, then
that slot is set to basic hot-swap. Continue with Step 4 to manually disconnect the board before removing it.
4. Identify the attachment-point ID that corresponds to the slot where you will be removing the board.
As superuser, enter:
The attachment-point ID is shown in the first column of the readout; for example, the attachment-point ID for slot 4 in a Netra CT 810 server would be
IO-4.
5. Use the cfgadm(1M) utility to disconnect power to the board:
where ap_id is the attachment-point ID. For example, to deactivate the board in slot 4, as superuser, enter:
# prtconf -v -P
# cfgadm
# cfgadm -c unconfigure ap_id # cfgadm -c disconnect ap_id
# cfgadm -c unconfigure IO-4 # cfgadm -c disconnect IO-4
Page 38
22 Netra CT Server Hardware Upgrade Guide • February 2007
6. Attach the antistatic wrist strap.
7. Using a No. 2 Phillips screwdriver, loosen the two captive screws inside the board’s ejection levers, one on top and one on the bottom (
FIGURE 2-12).
FIGURE 2-12 Loosening the Ejection-Lever Captive Screws
8. Unlock the ejection levers.
Caution – Only unlock the ejection levers at this point; do not unseat the board.
Note – If the server is set to the default full hot-swap mode, unlocking the ejection
levers automatically starts the cfgadm unconfigure operation. If you decide that you do not want to remove the board, you must wait until the LEDs are in the correct state (as shown in Step 10), completely unseat the board, reseat it, then lock the ejection levers again to start the cfgadm configure operation. Simply locking the ejection levers after unlocking them will not start the driver attachment process.
9. Locate the LEDs on the system status panel for the board that you want to remove.
The system status panel on each server has LEDs that show the status of the board installed in each of the slots in the server.
FIGURE 2-13 shows the LEDs on the Netra
CT 810 server and
FIGURE 2-14 shows the LEDs on the Netra CT 410 server.
Page 39
Chapter 2 Upgrading the Hardware 23
FIGURE 2-13 LEDs on the System Status Panel (Netra CT 810 Server)
FIGURE 2-14 LEDs on the System Status Panel (Netra CT 410 Server)
10. Determine if you can remove the board safely at this time.
You can remove the board only if all of the LEDs are in the following states:
Amber Okay to Remove LED on the system status panel is on
Green Power LED on the system status panel is off
Blue Hot-swap LED on the board is on
Caution – Do not remove a board unless all of the LEDs are in the proper states. It
might take several seconds or minutes for the LEDs to transition to the proper states. If you remove a board when any of the LEDs are not in the proper state, the action could lead to unpredictable results.
Caution – Do not attempt to hot-swap any other boards until you see that the first
board has been fully deactivated. In some situations, it could take several minutes for the board to completely deactivate. Hot-swapping more than one board at the same time could lead to unpredictable results.
11. When it is safe to remove the board, disconnect any cables connected to the board.
Page 40
24 Netra CT Server Hardware Upgrade Guide • February 2007
Note – Satellite boards have no cables attached.
12. Press outward on the two ejection levers on the board to unseat the board from the board cage.
13. Carefully slide the board out of the slot and place it on the electrostatic discharge mat.
14. Remove and replace the rear transition module as described in the following section.
Removing and Replacing the Rear Transition Module
The Netra CP2500 board requires a corresponding host or satellite rear transition module. If you are replacing a host board, the host rear transition module (RTM-H) is included in the upgrade kit.
FIGURE 2-15 shows the location of rear transition modules on the Netra CT 810 server,
and
FIGURE 2-16 shows the location of rear transition modules on the Netra CT 410
server.
FIGURE 2-15 Locating a Rear Transition Module in a Netra CT 810 Server (Top View)
Alarm card
I/O board
I/O board
I/O board
I/O board
I/O board
I/O board
Host CPU board
Hard drives
Midplane
Front of chassis
Rear of chassis
Slot 8
Slot 4
Slot 5
Slot 6
Slot 7
Slot 2
Slot 3
Slot 1
Slot 8
Slot 4
Slot 5
Slot 6
Slot 7
Slot 2
Slot 3
Slot 1
Alarm RTM
I/O RTM
I/O RTM
I/O RTM
I/O RTM
I/O RTM
I/O RTM
Host RTM
Page 41
Chapter 2 Upgrading the Hardware 25
FIGURE 2-16 Locating a Rear Transition Module in a Netra CT 410 Server (Top View)
To Upgrade a Rear Transition Module
1. With the antistatic wriststrap attached to you, locate the host rear transition module that you want to remove.
2. Unplug any cables attached to the rear transition module.
3. Using a No. 2 Phillips screwdriver, loosen the two captive screws inside the board or module’s ejection levers, one on top and one on the bottom (
FIGURE 2-12).
4. Press out on the ejection levers to unseat the module.
5. Slide the module out of the slot and place it on the electrostatic discharge mat.
6. Obtain the new rear transition module.
Make sure that you have the corresponding rear transition module:
For a host Netra CP2500 board, obtain a host rear transition module (RTM-H).
For a satellite Netra CP2500 board, obtain a satellite rear transition module
(RTM-S).
These components have different part numbers, and the faceplates clearly indicate the RTM type.
7. If installing an RTM-S, confirm that the dip switch settings are all set to On.
The Netra CP2500 RTM-S module has two DIP switch banks (S1301 and S1302) that control the Ethernet network traffic through the RTM-S module. By default, the switches on these banks are all set to the ON position. In the ON position, all
Front o
f
chassis
Rear of chassis
Cables
Midplane
I/O board (slot 4)
I/O board (slot 5)
Double-wide 3U
Host CPU board (slot 3)
Hard drive
I/O RTM
I/O RTM
alarm card
Host RTM
Page 42
26 Netra CT Server Hardware Upgrade Guide • February 2007
network traffic gets routed out through the module’s RJ-45 connectors. When these switches are set to the Off position, all network traffic is routed to the cPSB backplane network.
FIGURE 2-17 shows the location of the S1301 DIP switch bank, which is located on the
component side of the RTM-S.
FIGURE 2-18 shows the location of the S1302 DIP
switch bank, which is located on the solder side of the RTM-S.
Caution – Never set the DIP switches on a Netra CP2500 RTM-H module. Sun does
not support changing the RTM-H DIP switches from their default settings.
FIGURE 2-17 S1301 DIP Switch Bank Location on the RTM-S (Component Side)
ON
12345678
ON
12345678
Page 43
Chapter 2 Upgrading the Hardware 27
FIGURE 2-18 S1302 DIP Switch Bank Location on the RTM-S (Solder Side)
8. Keeping the new rear transition module vertical, slide the module into the slot in between the two guides (
FIGURE 2-19).
The teeth in the handle of the module must align with the square cutouts in the slot. When the module is completely seated in the cage, the two ejection levers should flip inward, and the teeth in the ejection levers should fit smoothly in the rectangular cutouts in the bottom and top plates.
ON
12345678
ON
12345678
Page 44
28 Netra CT Server Hardware Upgrade Guide • February 2007
FIGURE 2-19 Aligning the Rear Transition Module with the Rear Cage Cutouts
9. Using a No. 2 Phillips screwdriver, tighten the two captive screws inside the module’s ejection levers, one on top and one on the bottom (
FIGURE 2-22).
Tighten the screws to a torque of 0.28 N.m (2.5 in.-lb).
10. Make the necessary cable connections to the rear transition module.
Tighten the screws on the cable to a torque of 0.23 N.m (2 in.-lb).
FIGURE 2-20 shows the connectors on the host rear transition module.
Page 45
Chapter 2 Upgrading the Hardware 29
FIGURE 2-20 Connectors on the Netra CP2500 Host Rear Transition Module (RTM-H)
11. After you replace the rear transition module, obtain the new Netra CP2500 board.
12. Go to the front of the server and install the new board, as described in the following section.
ENET 1
ENET 0
ENET 3
AB
COM
USE ONLY
WITH CP2500
ENET 2
HOST RTM
Cut out for PIM connector
10/100/1000 Ethernet RJ-45 connectors
Serial ports
10/100/1000 Ethernet RJ-45 connectors
Page 46
30 Netra CT Server Hardware Upgrade Guide • February 2007
Installing a Netra CP2500 Board
After removing the old board and replacing the rear transition module, install the new board as follows.
To Install a Netra CP2500 Board
1. With the antistatic wrist strap attached to you, locate the slot where you will be installing the new board.
FIGURE 2-10 shows the locations of boards in the Netra CT 810 server. FIGURE 2-11
shows the locations of boards in the Netra CT 410 server.
2. Remove the slot filler panel, if necessary.
The slot filler panel is secured to the board cage using two screws, one at the top of the filler panel, the other at the bottom. Store the slot filler panel in a safe place; you might need it later.
3. Obtain the new Netra CP2500 board.
4. Perform any board-specific hardware procedures, if necessary.
5. Verify that the ejection levers on the board are unlocked.
You will not be able to install the board properly if the ejection levers are locked.
6. Keeping the new board vertical, slide it into the slot between the two guides.
The cuts in the handle of the board must align with the square cutouts in the slot. When the board is completely seated in the cage, the two ejection levers should flip inward, and the notches in the ejection levers should fit smoothly in the rectangular cutouts in the bottom and top plates.
Caution – In the Netra CT 810, do not install Netra CP2500 boards in slots 6 and 7.
Increased temperatures might cause a server power down.
Page 47
Chapter 2 Upgrading the Hardware 31
FIGURE 2-21 Aligning the Board with the Board Cage Cutouts
7. Lock the ejection levers.
8. Using a No. 2 Phillips screwdriver, tighten the two captive screws inside the board’s ejection levers, one on top and one on the bottom.
Tighten the screws to a torque of 0.28 N.m (2.5 in.-lb).
HD
D1
ALAR
M /US
ER
HO
TS
W A P
ET
H
E RNET
R EA
D
Y
COM
R
ES
E T
ABORT
m i c r
o s y s te
m s
HO
T S W
A
P
COM 1 ENET 1 ENET 2
ALARM
COM 2
H DD
0
H
OT
S
W A P
COM 1 ENET 1 ENET 2
ALARM
COM 2
A LARM
/USE
R
HO
T S W
A P
E
TH
E R
NE
T
R E
A D
Y
CO
M
R
E SE
T
ABORT
m i c r
o s y s t e
m s
H D
D
0
HOT S W
A P
COM 1 ENET 1 ENET 2
ALARM
COM 2
Page 48
32 Netra CT Server Hardware Upgrade Guide • February 2007
FIGURE 2-22 Tightening the Ejection Lever Captive Screws
9. Log in to the Netra CT server.
10. Determine the hot-swap state for the slot that holds the board you just installed.
To determine the current hot-swap state for the slots in your server, as superuser, enter:
11. Identify the attachment-point ID that corresponds to the slot where you inserted the board.
As superuser, enter:
12. Connect the board with the cfgadm dynamic reconfiguration software:
# prtconf -v -P
# cfgadm
# cfgadm -c connect ap_id
Page 49
Chapter 2 Upgrading the Hardware 33
where ap_id is the attachment-point ID. For example, to connect the board in slot 4, as superuser, enter:
13. Activate the board with the cfgadm (1M) utility:
where ap_id is the attachment-point ID. For example, to activate the board in slot 4, as superuser, enter:
14. Locate the LEDs on the system status panel for the board that you just inserted.
FIGURE 2-13 shows the LEDs on the Netra CT 810 server and FIGURE 2-14 shows the
LEDs on the Netra CT 410 server.
15. Determine if the board is activated.
16. If the board activated successfully, perform any necessary board-specific software configuration.
Refer to the documentation that you received with the board for any board-specific procedures.
17. Connect the cables to the board’s corresponding rear transition module.
Tighten the screws on the cable to a torque of 0.23 N.m (2 in.-lb). The following figures show the connectors for host boards for Netra CT servers.
# cfgadm -c connect IO-4
# cfgadm -c configure ap_id
# cfgadm -c configure IO-4
Page 50
34 Netra CT Server Hardware Upgrade Guide • February 2007
FIGURE 2-23 Connectors on the Netra CP2140 Host CPU Board
HDD1
HOT SWAP
COM 1 ENET 1 ENET 2
ALARM
COM 2
A
L
A
R
M
/U
S
E
R
HOTSWAP
E
TH
ER
NET
R
E
A
DY
C
O
M
R
E
S
E
T
A
B
O
R
T
m icro
s ystem
s
TTY A port
Ethernet A port
Page 51
Chapter 2 Upgrading the Hardware 35
FIGURE 2-24 Connectors on the Netra CP2500 Host CPU Board
Blocking Air From Open Slots
In most cases, you are replacing a board with a new board, and no opening will result. However, if you are changing the configuration of your server’s slots while performing the upgrade and open slots result, close the slots with filler panels.
Caution – An energy hazard is present if any I/O slots are left uncovered. If you
remove a component from an I/O slot, you must fill it with either a replacement board or a filler panel.
AB
ORT
Page 52
36 Netra CT Server Hardware Upgrade Guide • February 2007
To Block Open Filler Panel Openings
If any panel openings resulted from the upgrade, install air-blocking filler panels.
The slot filler panel is secured to the cage using two screws, one at the top of the filler panel, the other at the bottom.
Performing Diagnostics
After you install the fan trays, new rear transition module, new board, and any other hardware components, verify that the new hardware is operating correctly.
To Perform Diagnostics
1. Use the tip utility to establish a full-duplex-terminal connection between a Sun workstation and the new board.
2. At the UNIX prompt in a command or shell tool window, enter:
3. Perform the following diagnostic steps.
a. Verify that the following information is accurate:
Valid memory configuration is displayed on the banner.
Valid Ethernet address is displayed on the banner.
b. At the ok prompt, enter:
Make sure all devices are recognized by the system.
Ensure that the hard drive is recognized as target 0, and that the CD-ROM
drive is recognized as target 6.
c. At the ok prompt, enter:
4. Run related applications.
> tip -9600 /dev/ttya
ok probe-scsi-all
ok .version
Page 53
Chapter 2 Upgrading the Hardware 37
5. Use the prtconf -D command to display the device tree.
It should show the PCI bus instances #0 and #1 for the two PCI buses. There are instances of various PCI boards connected to each one. A PCI board might show up as pciVVVV,DDDD, where VVVV is the vendor ID, for example, 1011 and DDDD is the device ID, for example 008e. If the driver for the board is already loaded, then you might see the device name supplied by the driver in the device tree.
6. Log in to the server console and, as superuser, enter the prtdiag command to ensure that no faults are generated and that the chassis state is configured.
Configuring the Hardware
For existing servers that you upgraded, configure the hardware components as follows.
Note – For new servers that have the required software and hardware preinstalled,
the Netra CP2500 board hardware is preconfigured. New systems are shipped with one Netra CP2500 board installed in the host slot.
To Reset the Platform Name
The Netra CP2500 has two platform names, one for the host role and one for the satellite role. You can use Solaris commands uname -i to derive the platform name. The names are as follows:
SUNW, NetraCT-810 or SUNW, NetraCT-410 if it is a host
SUNW, Netra-CP2500 if it is a satellite
When you install a Netra CP2500 board, the platform name will change from the Netra CP2140 host board to the new Netra CP2500 board.
If you created a custom script that uses the platform name to find out if a satellite
is plugged into a Netra CT Server, change the ChassisType property defined in the PICL FRU tree by running the prtpicl (1M) command as follows:
# prtdiag -v
# prtpicl -v -c fru | cut -f2 | tr -d ‘ ‘
Page 54
38 Netra CT Server Hardware Upgrade Guide • February 2007
To Configure the Board and RTM
1. (Optional) At the alarm card CLI prompt, enter the following:
2. If you want to configure a slot not to power on any boards, enter the following:
To Configure Fan Trays and Power Supplies
The following procedure is optional.
At the alarm card CLI prompt, use the Acceptable_Fru_Types command to
configure the fan trays and power supplies (PS).
The following are examples:
cli> setfru slot 2 Acceptable_Fru_Types
CP2500_Front_Board_Vendor_Name CP2500_Front_Board_Part_No:CP2500_RTM_Part_No
cli> setfru slot 2 Acceptable_Fru_Types none
cli> setfru fan 1 Acceptable_Fru_Types
FAN_Vendor_Name:FAN_Part_No
cli> setfru fan 2 Acceptable_Fru_Types
FAN_Vendor_Name:FAN_Part_No
cli> setfru ps 1 Acceptable_Fru_Types PS_Vendor_Name:PS_Part_No
cli> setfru ps 2 Acceptable_Fru_Types PS_Vendor_Name:PS_Part_No
Page 55
Chapter 2 Upgrading the Hardware 39
Troubleshooting
If you encounter any unusual system behavior, refer to the Netra CT Server Service Manual (819-2741) for troubleshooting information.
Page 56
40 Netra CT Server Hardware Upgrade Guide • February 2007
Page 57
41
CHAPTER
3
Firmware and Software Upgrade Process
This chapter describes how to upgrade the firmware and software in preparation for installing a Netra CP2500 board and associated hardware in a Netra CT 410 or Netra CT 810 server.
You can upgrade the firmware and software well in advance of installing the hardware. When upgrading multiple systems, it may be preferable to first upgrade the firmware and software, then perform testing to ensure that the upgrade is successful before upgrading the hardware.
This chapter contains the following topics:
“Preparing to Upgrade Software and Firmware” on page 42
“Upgrading the Firmware” on page 42
“Upgrading the Solaris Operating System” on page 44
“Validating the Upgrades” on page 46
Page 58
42 Netra CT Server Hardware Upgrade Guide • February 2007
Preparing to Upgrade Software and Firmware
Before upgrading the firmware and software, perform the tasks detailed in this section. The information in this section assumes your starting condition is a Netra CT 410 or Netra CT 810 server with either a Netra CP2140 or CP2160 board.
1. Back up the system configurations (host, satellite, or both) to another system.
2. Obtain the required versions of the firmware and software.
Upgrading the Firmware
The required versions of the CPU and alarm card firmware are provided in
Chapter 1 and might be superseded by versions documented in the Release Notes.
Perform the following procedures to upgrade the firmware.
To Determine Firmware Versions
1. To display the OpenBoot™ PROM version, SMC firmware, PLD, and SMC FPGA
information, type at the ok prompt:
2. To determine the current alarm card firmware version on the system, use the
version command at the alarm card CLI prompt.
ok .version
cli> version
Page 59
Chapter 3 Firmware and Software Upgrade Process 43
To Obtain Newer Firmware Versions
If you do not have the most current versions of the CPU and alarm card firmware,
go to the SunSolve
SM
Web site, http://www.sun.com/sunsolve, and download
the most recent versions of the following firmware patches:
116345 (OpenBoot PROM and SMC firmware for Netra CP2140)
116346 (OpenBoot PROM and SMC firmware for Netra CP2160)
To Update the OpenBoot PROM Firmware
Refer to the following documentation:
Readme file in the patch, for any special installation instructions
Netra CP2140 Technical Reference and Installation Manual (816-4908) or Netra CP2160
Technical Reference and Installation Manual (816-5772) for instructions on upgrading the firmware
Netra CP2500 Installation and Technical Reference Manual (819-1747)
To Update the Alarm Card Firmware
Refer to the Readme file in the patch for any special installation instructions, and to the Netra CT Server System Administration Guide (819-2743) for instructions on upgrading the firmware on the alarm card.
Page 60
44 Netra CT Server Hardware Upgrade Guide • February 2007
Upgrading the Solaris Operating System
The following information provides instructions for upgrading to the minimum required software operating system. The software requirements are detailed in
Chapter 1.
To Determine Software Version
To determine the release number of Solaris OS, at the machinename prompt type:
The Solaris version displays in the following format: X.X.X or X.X
To Upgrade the Operating System
The Netra CP2500 board requires the Solaris 9 FCS Operating System (Solaris 9 FCS OS) with patches for the Netra CT810 and Netra CT410 servers.
To obtain the Solaris 9 FCS OS, contact either your sales representative or field service technician. This OS version is available only by special order (part number SOLZS-09AC9AYM) through a qualified Sun representative.
Upgrade the OS as follows. For detailed instructions, refer to the Solaris 9 Operating System Collection documentation.
1. Install the software by one of the following methods:
To install the system from the CD, at the ok prompt, enter:
The system boots from the CD and the Solaris OS installation
begins. Provide
appropriate answers to various prompts that are displayed as the software is installed.
To install the system from a server, obtain the boot client Ethernet address (the
system being built).
machine-name% uname -r
ok boot cdrom
Page 61
Chapter 3 Firmware and Software Upgrade Process 45
a. At the ok prompt (on the system being built), enter:
The Ethernet address is displayed in the following format: X:X:XX:XX:XX:XX, for example: 8:0:20:7e:f6:dc.
b. Type the Ethernet address obtained in Step a into the install server as a boot
client.
Refer to the Solaris software documentation to set up an install server.
c. At the ok prompt on the client (of the system being built), enter:
The system boots from the network and the Solaris software is installed from the network. Various prompts are displayed as the system is installed; answer them as appropriate.
2. After the Solaris OS is installed, at the ok prompt, enter:
The system configures itself after the installation. If the installation is successful, the system boots to a Solaris login prompt.
To Download and Install Patches
Download the patches from the SunSolve web sites, then apply them. For the latest listing of patches and detailed instructions for downloading and applying them, refer to the Netra CT Server Release Notes (819-2739).
ok banner
ok boot net
ok boot disk -rv
Page 62
46 Netra CT Server Hardware Upgrade Guide • February 2007
Validating the Upgrades
After installing the firmware, software, and patches, validate that the upgraded versions were installed correctly.
To Validate the Upgrades
1. To display the OpenBoot PROM version, SMC firmware, PLD, and SMC FPGA
information, type the version command at the ok prompt:
2. To display the alarm card firmware version on the system, type the version command at the alarm card CLI prompt.
3. To display the patch versions, enter the following command:
ok .version
cli> version
#> showrev -p
Page 63
47
Index
Symbols
.version command, 36
A
Acceptable_Fru_Types command,38 alarm card
firmware, upgrading, 43 alarm card firmware, version, 42 applications, running with Netra CP2500 boards, 2 attachment-point ID, 21
B
boards
configuring, 38
connecting, 32
installing, 30
installing additional, 10
LED states for removing, 23
mixing, 3
removing, 20
C
cables, connecting, 33 captive screws, 22
cfgadm,21 cfgadm -c disconnect,21 cfgadm -c unconfigure,21 cfgadm dynamic reconfiguration software, 32 ChassisType property, 37
comments, submitting for this document, xv components, optional, 4
configurations, 7
boards, 38 hardware, 37 Netra CT 410 server, 8 Netra CT 810 server, 8
upgrading, 1 CPU board firmware rules, 3 CPU roles, 7
D
device tree, drivers, 37 diagnostics, 36 dip switch settings, 25 disconnect command, 21 documentation, xv
E
ejection levers, 22 Ethernet address, 45
F
fan trays
configuring, 38
installing, 11
LEDs, 17
part numbers, 11
removing, 11
replacing, 15 faults, 37 filler panel, 36 firmware
CPU board rules, 3
Page 64
48 Netra CT Server Hardware Upgrade Guide • February 2007
obtaining, 43
upgrading, 42 firmware versions, determining, 42 firmware, upgrading, 41 firmware, validating upgrades, 46
H
hardware
configuring, 37
requirements, 3
upgrading, 9
upgrading, preparation, 10 high-speed fan trays, required, 11 host
board, upgrading, 18
requirements, 4
role, 7
upgrade kits, 4 hot swap state, determining, 32
I
I/O slots, open, 35 important information, upgrading, 1 installing
boards, 30
fan trays, 11
L
LEDs, states required for removing a board, 23
M
maximum Netra CP2500 boards, 10
N
Netra CP2140 cPCI board
features, 2 Netra CP2500 board
new systems, xi Netra CP2500 boards
applications, 2
features, 2
maximum, 10 Netra CT 410 server configurations, 8 Netra CT 810
server configurations, 8
slot cooling, 30
node processor, using Netra CP2500 as, xi
O
OpenBoot PROM firmware, upgrading, 43 OpenBoot PROM version, 42 operating system, upgrading, 44 optional components, 4
P
patches, downloading and installing, 45 patches, validating upgrades, 46 PCI bus instances, 37 PICL FRU tree, 37 platform names, 37 PLD, 42 power
available, slots, 6 configuring a slot not to power on, 38 supplies, configuring, 38 supply requirements, calculating, 5
prerequisites, audience knowledge, xi
probe-scsi-all command, 36 prtconf -D command, 37 prtdiag command, 37 prtdiag -v command, 37 prtpicl (1M) command, 37
R
Readme files, patches, 43 rear transition module
corresponding to board, 25
upgrading, 24 related documentation, xiv replacing
fan tray, 15 requirements
hardware, 3
high-speed fan trays, 11
host, 4
power available, slots, 6
power supply, calculating, 5
satellite, 4
software and firmware, 3
Solaris OS, 3
Sun cPCI components, power, 5
system, 2
Page 65
Index 49
system, minimum, 2 upgrading, 1
roles, 7
S
satellite
boards, upgrading, 18 requirements, 4
role, 7 setfru command, 38 shell prompts, xiii showfru command, 11 slots, blocking, 35 SMC firmware, 42 SMC FPGA, 42 software, installing, 44 software, upgrading, 41 software, validating upgrades, 46 Solaris 9 FCS Operating System, 44 Solaris Operating System, upgrading, 44 Solaris OS requirement, 3 Solaris OS, determining version, 44 Solaris™ Operating System documentation, xii Sun cPCI components, power requirements, 5 SunSolveSM Web site, 43 support, xv system requirements, 2 system status panel, 12
T
training, xv troubleshooting, 39 typographic conventions, xiii
U
unconfigure command, 21 UNIX Commands, using, xii upgrade kits, host, 4 upgrading
alarm card firmware, 43
firmware, 42
hardware, 9
hardware, preparation, 10
host board, 18
OpenBoot PROM firmware, 43
operating system, 44 preparation, 42 satellite boards, 18 software, 41 Solaris OS, 44
V
versions
alarm card firmware, 42 firmware, 42 SMC firmware, 42 Solaris OS, determining, 44
W
web sites, third-party, xv
Page 66
50 Netra CT Server Hardware Upgrade Guide • February 2007
Loading...