Sun Microsystems FastEthernet PCI Adapter Product Note

Sun
FastEthernet PCI
Adapter Product Note
A Sun Microsystems, Inc. Business 901 San Antonio Road Palo Alto, California 94303 USA 415 960-1300 fax 415 969-9131
Copyright 1997 Sun Microsystems,Inc.2550GarciaAvenue, Mountain View,California94043-1100U.S.A.Allrightsreserved. This productordocumentisprotectedbycopyrightanddistributedunderlicensesrestrictingitsuse,copying,distribution, and decompilation.
No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Third-party software,including font technology,is copyrighted and licensed from Sun suppliers.
Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in the U.S. and other countries, exclusively licensed through X/Open Company, Ltd.
Sun, Sun Microsystems, the Sun logo, AnswerBook, SunDocs, FastEthernet, SunSwift, and Solaris service marks of Sun Microsystems, Inc. in the U.S. and other countries. All SPARCtrademarks are used under license and are trademarks or registeredtrademarks of SPARCInternational, Inc. in the U.S. and othercountries. Products bearing SPARCtrademarks arebased upon an architecturedeveloped by Sun Microsystems, Inc.
The OPEN LOOK and Sun™ Graphical User Interface was developed by Sun Microsystems,Inc. for its users and licensees. Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry.Sun holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun’s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun’s written license agreements.
RESTRICTEDRIGHTS: Use, duplication,or disclosure by the U.S. Government is subject to restrictions of FAR52.227-14(g)(2)(6/87) and FAR52.227-19(6/87), or DFAR252.227-7015(b)(6/95) and DFAR227.7202-3(a).
DOCUMENTATION IS PROVIDED“AS IS” ANDALL EXPRESS OR IMPLIEDCONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON­INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
Copyright 1997 Sun Microsystems, Inc., 2550 Garcia Avenue,Mountain View, Californie 94043-1100Etatis-Unis. Tousdroits réservés. Ce produit ou document est protégé par un copyright et distribué avec des licences qui en restreignentl’utilisation, la copie, la distribution, et la
décompilation. Aucune partie de ce produit ou document ne peut être reproduitesous aucune forme, par quelque moyen que ce soit, sans l’autorisation préalable et écrite de Sun et de ses bailleurs de licence, s’il y en a. Le logiciel détenu par des tiers, et qui comprend la technologie relativeaux polices de caractères, est protégé par un copyright et licencié par des fournisseurs de Sun.
Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l’Université de Californie. UNIX est une marque déposée aux Etats-Unis et dans d’autres pays et licenciée exclusivement par X/Open Company, Ltd.
Sun, Sun Microsystems, le logo Sun, AnswerBook, SunDocs, FastEthernet, SunSwift, et Solaris sont des marques de fabrique ou des marques déposées, ou marques de service, de Sun Microsystems, Inc. aux Etats-Unis et dans d’autres pays. Toutes les marques SPARCsont utilisées sous licence et sont des marques de fabrique ou des marques déposéesde SPARCInternational, Inc. aux Etats-Unis et dansd’autres pays. Les produitsportant les marques SPARCsont basés sur une architecturedéveloppée par Sun Microsystems, Inc.
aretrademarks, registered trademarks, or
L’interfaced’utilisation graphique OPEN LOOK et Sun™ a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun reconnaîtles efforts de pionniers de Xerox pour la rechercheet le développement du concept des interfaces d’utilisation visuelle ou graphique pour l’industrie de l’informatique. Sun détient une licence non exclusive de Xerox sur l’interface d’utilisation graphique Xerox, cette licence couvrant également les licenciés de Sun qui mettent en place l’interface d’utilisation graphique OPEN LOOK et qui en outre se conforment aux licences écrites de Sun.
CETTE PUBLICATION EST FOURNIE "EN L’ETAT" ET AUCUNE GARANTIE, EXPRESSE OU IMPLICITE, N’EST ACCORDEE, Y COMPRIS DES GARANTIES CONCERNANT LA VALEUR MARCHANDE, L’APTITUDE DE LA PUBLICATION A REPONDRE A UNE UTILISATION PARTICULIERE, OU LE FAIT QU’ELLE NE SOIT PAS CONTREFAISANTE DE PRODUIT DE TIERS. CE DENI DE GARANTIE NE S’APPLIQUERAIT PAS, DANS LA MESURE OU IL SERAIT TENU JURIDIQUEMENT NUL ET NON AVENU.
Please
Recycle
Sun FastEthernet PCI Adapter Product Note
This document contains the late-breaking news and documentation updates for the Sun™ FastEthernet™ PCI adapter.
Replacing a SunSwift PCI Adapter With a Sun FastEthernet PCI Adapter in the Same PCI Slot
Your system will encounter network problems if you replace a SunSwift™ PCI adapter with a Sun FastEthernet PCI adapter, or if you replace a Sun FastEthernet PCI adapter with a SunSwift PCI adapter, in the same PCI slot. To avoid these problems, you must rename the /etc/hostname.hme<num> file on your system to reflect the new adapter ’s Ethernet interface. The /etc/path_to_inst file will be updated when you perform a reconfiguration boot on your system after installing the new PCI adapter.
If you are replacing a SunSwift PCI adapter with a Sun FastEthernet PCI adapter,
see page 2.
If you are replacing a Sun FastEthernet PCI adapter with a SunSwift PCI adapter,
see page 4.
Note – If you are adding a new adapter into a different PCI slot, refer to the
adapter’s installation and user ’s Guide for instructions on how to install the adapter and configure the software.
1
To Replace the SunSwift PCI Adapter With a
Sun FastEthernet PCI Adapter in the Same PCI Slot
Note – Refer to your system’s installation or service manual for detailed
instructions for the following three steps.
1. Power off your system and open the system unit.
2. Replace the SunSwift PCI adapter with the Sun FastEthernet PCI adapter.
3. Close the system unit.
4. Power on the system, and when the OpenBoot PROM’s banner is displayed, press the Stop-A keys to interrupt the boot process and to display the ok prompt.
5. At the ok prompt, use the show-nets command to list the system’s network devices and to verify the Sun FastEthernet PCI adapter’s installation.
You will see the system’s network devices, which should be similar to the example below.
ok show-nets a) /pci@1f,4000/SUNW,hme@2,1 b) /pci@1f,4000/network@1,1 q) NO SELECTION Enter Selection, q to quit: q ok
hme identifies the Sun FastEthernet PCI adapter’s Ethernet device
network identifies the on-board Ethernet Device
Make a note of the Sun FastEthernet PCI adapter’s hme pathname for future reference.
Note – If these devices are not listed, check that the adapter is properly seated and
reinstall the adapter, if necessary.
2 Sun FastEthernet PCI Adapter Product Note • August 1997
6. Perform a reconfiguration boot on your system.
ok boot -r
After rebooting your system, login as super-user (root).
7. At the command line, use the grep command to search the /etc/path_to_inst file for hme devices.
# grep hme /etc/path_to_inst "/pci@1f,4000/network@1,1" 0 "hme" (On-board hme interface) "/pci@1f,4000/pci@2/SUNW,hme@0,1" 1 "hme" (SunSwift PCI hme interface) "/pci@1f,4000/SUNW,hme@2,1" 2 "hme" (Sun FastEthernet PCI hme interface)
In the example above, the network@1,1 instance is the on-board FastEthernet device, the old SUNW,hme@0,1 instance is for the previous SunSwift PCI adapter, and the new SUNW,hme@2,1 instance is for the Sun FastEthernet PCI adapter.
You will need to know the instance number for Sun FastEthernet PCI adapter. In the above example, the instance number for the Sun FastEthernet PCI adapter is 2, which is shown in bold.
8. Using the instance number found in Step 7, rename the /etc/hostname.hme<num> file previously used by the SunSwift PCI adapter to reflect the new instance number used by the Sun FastEthernet PCI adapter.
For example, if the previous file had an *.hme1 extension, and the new instance number is 2, you would type:
# mv /etc/hostname.hme1 /etc/hostname.hme2
9. Halt and reboot your system.
# init 6
Note – Refer to the Sun FastEthernet PCI Adapter Installation and User’s Guide for
more information about configuring the driver software.
Sun FastEthernet PCI Adapter Product Note 3
To Replace the Sun FastEthernet PCI Adapter
With a SunSwift PCI Adapter in the Same PCI Slot
Note – Refer to your system’s installation or service manual for detailed
instructions for the following three steps.
1. Power off your system and open the system unit.
2. Replace the Sun FastEthernet PCI adapter with the SunSwift PCI adapter.
3. Close the system unit.
4. Power on the system, and when the OpenBoot PROM’s banner is displayed, press the Stop-A keys to interrupt the boot process and to display the ok prompt.
5. At the ok prompt, use the show-nets command to list the system’s network devices and to verify the SunSwift PCI adapter’s installation.
You will see the system’s network devices, which should be similar to the example below.
ok show-nets a) /pci@1f,4000/pci@2/SUNW,hme@0,1 b) /pci@1f,4000/network@1,1 q) NO SELECTION Enter Selection, q to quit: q ok
hme identifies the SunSwift PCI adapter’s Ethernet device
network identifies the on-board Ethernet Device
Make a note of the SunSwift adapter’s hme pathname for future reference.
Note – If these devices are not listed, check that the adapter is properly seated and
reinstall the adapter, if necessary.
6. Perform a reconfiguration boot on your system.
ok boot -r
After rebooting your system, login as super-user (root).
4 Sun FastEthernet PCI Adapter Product Note • August 1997
7. At the command line, use the grep command to search the /etc/path_to_inst file for hme devices.
# grep hme /etc/path_to_inst "/pci@1f,4000/network@1,1" 0 "hme" (On-board hme interface) "/pci@1f,4000/SUNW,hme@2,1" 1 "hme" (Sun FastEthernet PCI hme interface) "/pci@1f,4000/pci@2/SUNW,hme@0,1" 2 "hme" (SunSwift PCI hme interface)
In the example above, the network@1,1 instance is the on-board FastEthernet device, the old SUNW,hme@2,1 instance is for the previous Sun FastEthernet PCI adapter, and the new SUNW,hme@0,1 instance is for the SunSwift PCI adapter.
You will need to know the instance number for the SunSwift PCI adapter. In the above example, the instance number for the SunSwift PCI adapter is 2, which is shown in bold.
8. Using the instance number found in Step 7, rename the /etc/hostname.hme<num> file previously used by the Sun FastEthernet PCI adapter to reflect the new instance number.
For example, if the previous file had an *.hme1 extension, and the new instance number is 2, you would type:
# mv /etc/hostname.hme1 /etc/hostname.hme2
9. Halt and reboot your system.
# init 6
Note – Refer to the SunSwift PCI Adapter Installation and User’s Guide for more
information about configuring the driver software.
Sun FastEthernet PCI Adapter Product Note 5
Using the test net Command on an Adapter With an External Transceiver
If your adapter is connected to an external transceiver, you will see incorrect error messages when using the OpenBoot PROM (OBP) test net command. Although the test net command will pass the first time it is used, it will fail on subsequent tests, even though the Ethernet interface is functional and can be used.
You can avoid seeing these false test failures by using the OBP reset-all command between testing the adapter with test net command. Refer to bug id. 4062368 for more information.
Note – Refer to the OpenBoot 3.x Command Reference Manual (part number:
802-5837-xx) for more information about the test net and reset-all commands. This document can be found in the Solaris 2.6 Answerbook.
Known Problems
The following sections list the known problems and workarounds if they exist.
Fiber Optic Transceivers
The Sun FastEthernet PCI adapter’s MII interface does not support external Fiber Optic (FX) transceivers. However, the adapter’s MII interface does support TX, T4, and AUI external transceivers that comply with the IEEE 802.3u standard.
Refer to bug id. 4062714 for more information.
FastEthernet Switches (100BASET)
There are two FastEthernet (100BASET) switches which currently do not operate with the Sun FastEthernet PCI adapter:
Bay Networks Model 28115
Fore Systems (all models)
6 Sun FastEthernet PCI Adapter Product Note • August 1997
Autonegotiation
Autonegotiation is broken (10Mbps) in the hme driver. Refer to bug id. 4064879 for more information. Patch 104212-06 fixes bug 4064879.
Ultra 170E
In the Ultra 170E, an MII-AUI transceiver hangs the network in 10Base-T mode. Refer to bug id. 1252776 for more information. Patch 10412-04 fixes bug 1252776 and resolves the problems with MII-AUI
transceivers in full-duplex mode on dumb 10Base-T hubs.
Sun FastEthernet PCI Adapter Product Note 7
8 Sun FastEthernet PCI Adapter Product Note • August 1997
Loading...