Sunleaves SAC600 User Manual

Thank you for purchasing this quality Sunleaves Air Conditioner!
Please read through this manual completely, and keep it in case you need to reference the information in the future.
Any operation of this device beyond that which is described in this manual, and/or any unapproved attempt to repair this device, will void the product’s warranty and is undertaken at your own risk. Sunleaves is not responsible for damage caused by inappropriate operation of this device.
SAC600 REV 092010
Table of Contents
Sunleaves Air Conditioner
1. Introduction .......................................................1
2. Technical Specifications ................................2
3.
Package Contents ................................................3
4. Operation ............................................................4
5. Maintenance & Trouble Shooting ..........12
6. Safety & Special Guidelines .......................13
7. Warranty Information ................................15
8. Service ...............................................................15
Temperature Conversion Table .................16
9.
Introduction
This portable air conditioner is a new generation air conditioner which is ideal for us­ing in your bedroom, study, offi ce, meeting room, warehouse, grow room or any other room that needs air conditioning. It’s fl exibility enables easy adjustments to desired room temperatures and humidity. The built-in fi lter removes dust and purifi es the air to create a healthier environment.
It is designed with practicality, portability, and convenience in mind to satisfy the need for convenient, effi cient and mobile air conditioning. It is easy to use, does not need installation and is simple to maintain. The options for remote control or manual control along with an easy to read LCD display makes it effortless to operate.
The compact design and multiple functions along with minimal noise and power con­sumption make this unit very competitive with other portable air conditioning units. Our goal is to offer an effi cient air conditioner that will help you control your environ­ment to make it comfortable.
This instruction manual is for reference only and does not constitute a contract. We reserve the right to make technical changes without prior notice.
SAC600
1
Technical Specifi cation
Model SAC600
Cooling capacity (Btu/h) 12000
Dehumidifying (G/day) 10.5
Power Cooling 1100W
Dehumidifying 950W
Heating N/A
Circulation volume (CFM) 205
Power source (single phase) AC110-120V/60Hz
Noise pressure level dB(A)
<52
Net weight 103 lbs
Dimension Body (inches) 35” x 21” x 20”
Package (inches) 43” x 21” x 23”
Refrigerant R410A
Applying space 50’ x 65’
Note:
1. The above cooling capacity is measured at ambient temperature Db86oF, WB78oF (indoor and outdoor the same)
2. Noise level is measured at the point where one yard away from the front of the machine, in cooling mode.
3. Fan power consumption is measured when fan runs at the highest speed.
4. Specifi cation listed above is for reference only, please see actual data printed on the label.
5. The compressor inside this unit is not sealed, so a small amount of air from the room in which it sits may be exchanged through the interior air inlet found on the back of the unit.
2
SAC600
Package Contents
1. Control Panel
2. Air Outlet
3. Handle
4. Caster
5. Interior Air Outlet
6. Exhausted Air Outlet
7. Exterior Air Inlet
8. Electric Cable
9. Duct Connector (2)
10. Flex Tube (2)
11. Remote Control
12. Drain Tray
13. Drain Cap
SAC600
3
Operation
The operating range for cooling and dehumidifying operation is 59OF-88OF / 15OC-31OC
* Press the UP and DOWN arrow of the temperature button at the same time to switch between Celcius and Fahrenheit
1. Panel
• Display Panel
• Operation Panel
2. Power Switch Button
Press Power button. Once the power is on, the unit will run at auto mode and the LCD window will display “AUTO”.
Press the Power button while the unit is running and the unit turns off, and the timer setting is cancelled, but the other settings (mode, set temperature, fan speed and air fl ow mode) are still set.
Press Power button to turn the unit on and the unit starts running with the previous settings but the previous timer setting has been canceled.
3. MODE Button
Press the MODE button to choose the settings of: AUTO, COOL, FAN, DEHUMIDIFY and the setting will display in the LCD window.
4
SAC600
Operation
4. SPEED Button
Press SPEED button to choose the fan speed of: LOW, MID, HIGH, and this will display in LCD window.
5. Temperature Button
Press the TEMP button up or down to adjust the temperature. Select the desired temperature and it will display in LCD window. The temperature adjustments range is 59OF-88OF / 15OC-31OC. When unit is set at AUTO running mode, the default cooling temperature is 73OF / 23OC. Please see Celsius to Fahrenheit conversion table on page 16.
6. TIMER setting button
• AUTO OFF TIME SETTING
While the unit is on press the TIMER button to set the desired OFF time. The time setting ranges from 0.5 hours to 12 hours in half hour increments. The timer setting will display in the LCD window.
• AUTO ON TIME SETTING
While the unit is off, press the TIMER button to set the desired ON time. The time setting ranges from 0.5 hours to 12 hours in half hour increments. The timer setting will display in the LCD window.
7. Wind Direction Adjustment
Vertical: press the wind adjustment button in control panel or in the remote control, the air vent will swing vertically automatically.
Horizontal: adjust the air vent manually to desired wind fl ow direction.
SAC600
5
Remote Control
• Insert 2 AAA batteries (not included) into the remote control
Signal Transmission Indicator: Press once will display informa­tion in LCD window and it will disappear in a few seconds.
Wind Button: Press wind button to start or stop air fl ow
Temp Button: Press to increase set room temperature
O
F / 1OC.
1
Mode Button: Press to change the unit run mode.
in a vertical direction
Speed Button: Press once to change fan speed to Low, Mid, and High speed.
Operation
Timer Button: Adjust the Auto OFF setting while the unit is on and adjust the AUTO ON setting while the unit is off.
• Please point the remote control to the signal receiver on the unit panel.
• LCD window can display AUTO, COOL, FAN, DEHUMIDIFY, SPEED, TEMP etc.
POWER Button: Press once to start and press again to stop the unit.
Temp Button: Press to decrease set room temperature
O
1
F / 1OC.
6
SAC600
Operation
Remote Control (AUTO mode) Remote Control (WIND button)
1. Insert batteries and press POWER button to turn the system on.
Wind Button: Choose on or off mode.
• The unit automatically shuts on or off according to the room temperature.
• After the unit shuts off wait at least 3 minutes before you continue operation.
SAC600
• Please point the remote control toward the signal receiver on the unit panel.
7
Operation
Remote Control (Dehumidify mode)
1. Insert batteries and press POWER to turn the system on.
Remote Control (Cool mode)
1. Insert batteries and press POWER to turn the system on.
Mode Temp Speed
3. Press TEMP but­ton to set the desired room temperature.
4. Press SPEED but­ton to choose desired fan speed
Dehumidify mode: The compres­sor is running and interior fan motor is running at a low speed.
• When the room temperature is higher than the set temperature, the compressor will start running.
• When the room temperature is lower than the set temperature, the compressor shuts off, and the fan returns to the original speed.
8
SAC600
Operation
Remote Control (Timer button)
1. While the unit is running, press the Timer button to set auto OFF time.
2. Use the Timer but­ton to set auto OFF time at 0.5 hour incre­ments from 0.5 hour to 12 hours.
3. To cancel OFF time, press the TIMER button to 12 hours and press once more to cancel.
4. When the unit is OFF, press Timer button to set auto ON time.
5. User the Timer button to set auto ON time at 0.5 hour incre­ments from 0.5 hour to 12 hours.
Remote Control (Fan mode)
1. Insert batteries and press POWER button to turn the system on.
3. Press Speed button to choose desired fan speed.
• The unit must be connected to a power supply to set the auto ON time.
SAC600
6. To cancel ON time press the timer button to 12 hours and press once more to cancel.
• Fan mode: The compressor and outer fan motor stop and the inner fan motor runs at a set speed to circulate the air instead of cooling.
9
Operation
Air Exhaust Duct and Air Intake Duct
Since the unit is a portable air conditioner, it can move from one room to another easily. You can set up the ducting in the ways listed below to intake outer air and exhaust heated air:
1. Intake outer air and exhaust heated air from a window
Air Exhaust Duct
Air Intake Duct
• Open the window to fi t the plastic ducting outside window and secure them out of the window.
2. Intake outer air and exhaust heated air from the door
Air Intake Duct
• Open the door to fi t the plastic ducting and secure them outside of the door. Warning: The air exhaust duct must be placed above the air intake duct
Air Exhaust Duct
• Duct can be placed on the ground safely
• When fi nished using the unit, remove the ducts and store them carefully
10
SAC600
Operation
1. The duct can be extended from 20” to
78” , however, the shorter the exhaust duct, the better the performance.
2. The air exhaust duct must be placed above the air intake duct.
3. Make sure the heat exhaust duct is not kinked or bent, this can cause blockage in the exhaust duct and cause back fl ow, triggering the auto shut-off mechanism.
4. In order to make sure the air intake duct functions properly, please do not put any objects around the duct. Otherwise the air conditioner will fail to remove the hot air and cool the condensor. This will also cause the compressor to auto shut off.
5. Follow all specifi cations, or the unit will not function properly.
SAC600
11
Maintenance & Trouble Shooting
• Turn off unit before cleaning to prevent electric shock
• Unplug power cord to prevent electric shock
• Don’t use chemical solvent (like benzene, alcohol) to clean the unit’s surface. Otherwise, the unit’s surface can be easily damaged.
• If the air fi lter is blocked, the unit will not function properly. Please clean air fi lter at least once every few weeks to avoid clogs.
To open the air fi lter:
1. Open the air fi lter cover and remove air fi lter cover.
2. Remove air fi lter from fi lter cover.
To clean the air fi lter
Wash the air fi lter by immersing it gently into warm water with a neutral detergent. Fully rinse the fi lter and allow to dry completely before re-inserting.
12
SAC600
Maintenance & Trouble Shooting
Use soft cloth to clean surface, and remove all moisture before using.
Drainage:
This portable air conditioner collects moisture from the air. If the humidity around the machine is low, the water in the unit will be completely vaporized by the condenser. There will be less water in the tank, and there will be no need to drain the water tank. But, if the humidity around the unit is heavy, the unit will capture more water, and the water will not be able to be vaporized by the condense r. When the water tank is full, the machine will shut off, and an alarm will sound. The LCD display will show “E4”. Then the machine will stop after the fan keeps working for 3 minutes. In order to drain the water in the water tank, please do the following:
1. Put the water drain tray under the machine.
2. Remove the drain cap underneath the back of the unit.
3. Drain all the water in the water tank.
4. Re-fasten the drain cap.
Before contacting repair services, please check the following:
Problem Cause Solution
The unit does not work
The unit stops running automatically
No cool air in cooling mode
No cool air in dehumidifying mode
Power supply faulty
1. Not plugged in
2. Bad plug or socket
3. Fuse blown, or faulty wiring
Timer is set, or room temperature is lower than set temperature
1. Room temperature is lower than set temperature
2. There is frost on the evaporator
Frost on the evaporator The unit is defrosting and
1. Plug in correctly
2. Change the plug or socket
3. Send unit to service center to replace fuse (fuse:3.15A 250V)
Shut off timer or wait to run automatically
1. It is a normal occurrence
2. The unit is defrosting and will run properly when process is fi nished
will run properly when process is fi nished
Error code E2 Room temperature sensor failure Change the room
Error code E3 Indoor coil sensor failure Change the indoor coil sensor
Error code E4 Water tank is full Empty water in water tank
SAC600
temperature sensor
13
Safety & Special Guidelines
• Do not use unit near gas appliances, fires, or near flammable or combustible liquids
• Do not incline the unit while moving
• Do not mishandle or shake the unit
• Keep the unit one yard away from televisions or radios to avoid electromagnetic interference
• Do not place air exhaust duct too close to walls to avoid overheating of unit
• Do not use unit in crowded areas
• Avoid direct sunlight on unit to retain color
• Do not use the unit in water or near water to avoid electric shock
• If the power cord is damaged, it must be replaced by a certified technician
• Do not spray insecticide or other chemicals to avoid damaging the plastic housing
• To prolong the life of the unit, please make sure water tank is emptied completely before it is stored
• When using the auto-drain for a long period of time, please connect the drainage pipe
When there are problems with the unit, please stop using it and ask for advice from your local dealer or manufacturer.
After running the unit for an extended period of time, there will be dust in the air intake duct and it could effect the efficiency of the unit. We suggest cleaning the air intake duct and the air filter occasionally or asking for advice from your local dealer.
When the unit begins to work inefficiently, is broken, or other problems arise, please turn off and unplug the unit and request service from your local service provider.
14
SAC600
Warranty
Sunleaves 1-Year Limited Warranty
Sunleaves Portable Air Conditioners are protected against manufacturer defect by a limited 1-year manufacturer’s warranty.
Limited 1-Year Warranty Terms
Subject to the following limitations, Sunleaves Garden Products warrants that the Portable Air Conditioner will, for 1 (one) year from date of original retail purchase, but not exceeding two years from date of manufacture, remain free from appearance of defects in workmanship or materials. This warranty is subject to the following limitations: (a) manufacturer’s liability is limited to the replacement or repair of the unit, as decided by the manufacturer; (b) a defective unit must be returned, prepaid, with proof of purchase, to the point of purchase or as instructed below; and
(c) this warranty does not apply to defects resulting from the alteration, abuse, accidental damage, unauthorized repair, or misuse of the unit. This warranty is given in lieu of all other warranties, guarantees, and conditions on manufacturer’s part, and the manufacturer shall have no tortious or other liability in respect to this Portable Air Conditioner.
Portable Air Conditioner Warranty is Void if:
• NOT ACCOMPANIED BY ORIGINAL PROOF OF PURCHASE.
• AIR CONDITIONER HAS BEEN WIRED IN A MANNER DIFFERENT FROM MANUFACTURER RECOMMENDATION.
• AIR CONDITIONER HAS BEEN USED IN A NON-STANDARD WAY INCLUDING GENERAL MISUSE AND OUTDOOR USE.
• AIR CONDITIONER HAS BEEN DAMAGED AS A RESULT OF ACCIDENT, IMPROPER INSTALLATION, ALTERATION, FIRE, FLOOD, OR OTHER NATURAL DISASTER.
Sunleaves Garden Products
7854 North State Road 37
Bloomington, IN 47404
Sunleaves Product Warranty Claims
In the event that your Portable Air Conditioner fails to operate, we rec-
ommend first returning it to the place of purchase. Often times the supplier
will be able to examine the Portable Air Conditioner in closer detail. If the
dealer is unable to resolve the problem, or if you prefer to deal directly with
Sunleaves Garden Products, simply follow these instructions:
1. Call a Return Authorization Specialist toll-free at 888-464-9676 to obtain a Return Authorization number for warranty service as well as the shipping address to send your Portable Air Conditioner in for repairs.
Don’t forget to include the following items if you are returning your Portable Air Conditioner directly to Sunleaves:
Legible copy of your properly dated sales receipt
• Return Authorization number on outside of package
• This completed form
Return Authorization number (required): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Name: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Address: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Phone #: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Email Address: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Phone: 888-464-9676
Email: info@sunleaves.com
2. Carefully package problem Portable Air Conditioner. BE SURE TO WRITE YOUR RETURN AUTHORIZATION NUMBER ON THE OUTSIDE OF THE PACKAGE.
3. Complete the form below and enclose it with your shipment along with a legible copy of your properly dated sales receipt. Because Sunleaves is not responsible for damages in shipping, we recommend insuring your package. Note: Warranty claims which are not clearly
marked with your Return Authorization Number will be returned unopened to sender. Please allow eight to ten weeks for the return of your Portable Air Conditioner.
Explain the problem: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Note: This form is available at www.sunleaves.com on the product information page for each covered product.
SAC600
15
Celsius to Fahrenheit Conversion Table
Thank you for purchasing this quality Sunleaves Air Conditioner!
Celsius Fahrenheit
15
16
17
18
19
20
21
22
23
24
o
o
o
o
o
o
o
o
o
o
= 59.0
= 60.8
= 62.6
= 64.4
= 66.2
= 68.0
= 69.8
= 71.6
= 73.4
= 75.2
o
o
o
o
o
o
o
o
o
o
25
26
27
28
29
30
31
o
o
o
o
o
o
o
= 77.0
= 78.8
= 80.6
= 82.4
= 84.2
= 86.0
= 87.8
o
o
o
o
o
o
o
SAC600