Sunfull 1002-LITE, 1002-ARM, 2004-LITE, 2004-ARM, 2004-A9 Installation Instructions Manual

...
Installation instructions
Suitable gateway type1 network port 4 serial port 4 RS485, 1 RS232
Basic version: W7-1041 Gateway version: W7-1041-GW
1.0 Before use the software configuration step (refer to the relevant configuration software operation manual), please confirm the following:
- the configuration project is correct;(please refer to the X2View configuration software
- upload engineering files to the touch panel;
- simulation test to collect data;
2.0 Touch panel size
7 inch touch panel Hole size: 210.5mm x 146.5mm (L * W) weight: 550g Installation method: (Card buckle installation)
3.0 wiring instructions
Power supply: AC/DC 9~24V (rated power 5W); Network port: default IP address 192.168.1.88;
Full isolation RS485 interface: (COM1, COM2, COM3, COM4) A positive (+) B negative (-) GND (ground) Full isolation RS232 interface: Rx (2) TX (3) GND (5) DB9-M: Gateway RX (2) ~~ device TX (3)
Gateway TX (3) ~~ device RX (2) Gateway GND (5) ~~ equipment GND (5)
DB9-F: Gateway RX (2) ~~ device RX (2)
Gateway TX (3) ~~ device TX (3) Gateway GND (5) ~~ equipment GND (5)
4.0 Login touch panel Web server
Under the network cable to the Ethernet port, enter the URL on the browser:
http://192.168.1.88/login.html Login Username: admin Password: admin123456
Note: download gateway configuration software after entering the web server, please refer to the PDF document under the Help folder for specific operation.
5.0 common problems Q1: how to modify the IP address of the gateway/touch panel? A1: The gateway factory default IP address 192.168.1.88, subnet mask 255.255.255.0, default
gateway 192.168.1.1.
For the first time using, user need a cable directly connect computer and gateway/touch panel, and then change the IP address to the computer and gateway/touch panel within the same network segment (e.g., computer IP to 192.168.1.55), after confirmation to ping, open the browser, enter the URL: http://192.168.1.88/ login. HTML, log on to the Web server, as shown above in the " network" column set IP address.
Q2: What if the project files are not found in the computer? A2: The project files can be downloaded in the configuration software; or login the
gateway/touch panel to the WEB page "download " and click "project file" to download.
Q3: what is the difference between different models of the gateway hardware? A3:The main models are as follows:
Model
Hardware
Parameter
Interfaces
Supported
Points
Supported Ports
1002-LITE
CPU240MHz
Memory32M
1 ethernet
2 serial ports
256
2 RS485 &
2 RS232
1002-ARM
CPU240MHz
Memory32M
1 ethernet
2 serial ports
256
2 RS485 &
2 RS232
2004-LITE
CPU400MHz
Memory64M
2 ethernets
4 serial ports
1024
4 RS485
2004-ARM
CPU400MHz
Memory64M
2 ethernets
4 serial ports
1024
4 RS485
2004-A9
CPU1.4GMHz Memory512M
2 ethernets
4 serial ports
2048
4 RS485
1022-1U
CPU400MHz
MemoryDDR2
1 ethernets
4 serial ports
1024
4 RS485
Sunfull Gateway model
BACnet Gateway: BAC1002-LITE(economical),BAC1002-ARM,BAC2004-LITE(economical),
BAC2004-ARM, BAC2004-A9
Modbus Gateway: MOD1002-LITE (economical), MOD1002-ARM, MOD2004-LITE (economical),
MOD2004- ARM, MOD2004-A9
Modbus Hub Gateway: HUB1002- ARM, HUB2004-ARM SMS Alarm Gateway: HMI2004-A9-GPRS SNMP Gateway: SNMP1002- ARM, SNMP2004-ARM IEC104 Gateway: IEC 2004-ARM WEB Configuration Gateway: HMI2004-A9-GW
Sunfull WEB Touch Panel series
Basic version: W7-1041 Gateway version: W7-1041-GW, W10-1041-GW, W15-1041-GW
Sunfull Software Gateway
OPC transfer BACnet: O2B- Softkey, O2B-USBkey OPC transfer Modbus: O2M- Softkey, O2M-USBkey OPC transfer Modbus- cloud: O2M-WEB- Softkey, O2M-WEB-USBkey OPC transfer IEC104: O2I-SoftkeyO2I-USBkey OPC transfer SMS: O2S-SoftkeyO2S-USBkey OPC transfer Web: O2W-SoftkeyO2W-USBkey OPC transfer SNMP: OtS-SoftkeyOtS-USBkey
Sunfull OPC server
OPC server: X2O- Softkey, X2O-USBkey OPC server: OPCHub
Sunfull Free Software
BACnetScan scanning tool, MBUS scanning tool, Niagara interface, and WEBS interface
Welcome to follow Shanghai Sunfull’s wechat public number : BACnet
to know more new products and solutions.
Shanghai Sunfull Automation Co., LTD. TEL: +86-021-58776098 Address: A466,building1, NO.2588,JinhaiRoad,Pudong,Shanghai,China Technical support E-mail: support@opcmaster.com Technical support Tel: 021-20252795 Website 1: www.bacnetchina.com SalesTel: 13564889340 Contacts: Linda Chen Website 2: www.opcmaster.com