Congratulations on the purchase of your new Portofino spa! Listed below are important maintenance recommendations you should observe on a regular basis to protect your new investment.
Filter Maintenance
Your new spa is equipped with an advanced 2-stage water filtration system that provides unsurpassed water quality! To ensure maximum water quality at all times, you should clean and reuse the larger pleated filter car­tridge every month. See page 17-18 for detailed filter cleaning/replace­ment instructions.
Water Maintenance
You will want to replace the spa’s water every 3 to 6 months. The frequen­cy depends on a number of variables including the frequency of use, num­ber of users, attention paid to water quality maintenance, etc. You will know it is time for a change when you cannot control sudsing and/or you can no longer get the normal feel or sparkle to the water, even though the key water balance measurements are all within the proper parameters. See page 22 for additional information.
Table of Contents
1.0 Important Spa Owner’s Information................................... 1
2.0 FCC Notice............................................................................ 1
3.0 Important Safety Instructions ............................................. 2
3.1 General Electrical Safety Instructions .................................... 4
4.0 Choosing a Location ........................................................... 5
4.1 Outdoor Location ................................................................... 5
4.2 Indoor Location ...................................................................... 6
5.0 Power Supply Requirements .............................................. 6
6.0 Electrical Wiring Instructions ............................................. 8
7.0 Start-Up Instructions ........................................................... 9
7.1 Filling the Spa ........................................................................ 9
7.2 Safety Check........................................................................ 10
7.3 Initiating Water Circulation ................................................... 10
7.4 Adding Start-Up Chemicals ................................................. 10
8.0 Control Panel Functions ................................................... 11
9.0 Operating Instructions ...................................................... 12
9.1 Setting Water Temperature .................................................. 12
9.2 Pump Button ........................................................................ 12
9.3 Light Button .......................................................................... 12
9.4 Solo Massage Selector / Air Control Operation ................... 13
9.5 Metro Massage Selector / Air Control Operation ................. 13
9.6 Caprio Massage / Air Control Valve Operation .................... 14
9.7 Filtration Options .................................................................. 15
9.8 Standard Skimming/Heating Modes (F0-F3) ....................... 15
9.9 Economy Skimming/Heating Models (F4-F6) ...................... 15
9.10 Lock Modes (L1-L2) ............................................................. 15
9.11 Selecting the Skimming/Heating Mode ................................ 16
10.0 Care And Maintenance ...................................................... 17
10.1 Cleaning The Filter ............................................................... 17
10.2 Draining And Refilling ........................................................... 19
10.3 Cleaning The Spa Interior .................................................... 20
10.4 Cleaning The Pillows ............................................................ 20
10.5 Maintaining The Cover ........................................................ 21
10.6 Maintaining The Wood Cabinet ........................................... 21
10.7 Maintaining The Synthetic Cabinet ..................................... 21
10.8 Winterizing The Spa ............................................................ 21
10.9 Maintaining Water Quality ................................................... 22
10.10 Controlling pH ..................................................................... 22
10.11 Sanitizing / Using Additives ................................................. 23
11.0 Error Conditions / Error Messages ................................. 24
11.1 Summer Logic ..................................................................... 24
11.2 Overheat Condition
11.3 Panel displays
11.4 Panel displays
11.5 Panel displays
11.6 Panel displays
11.7 Panel displays
11.8 Panel displays
12.0 Troubleshooting Procedures ........................................... 26
12.1 No Components Operate (e.g. Pump, Light) ...................... 26
12.2 Pump Does Not Operate But Light Does ............................ 26
12.3 Poor Jet Action .................................................................... 27
12.4 Water is Too Hot .................................................................. 27
12.5 No Heat ............................................................................... 27
OH .......................................................
SN1 .............................................................
SN2 .............................................................
FL1 or FL2 ..................................................
COL ............................................................
ICE ..............................................................
- - - -
........................................................... 26
24 24 25 25 25 26
13.0 Spa Equipment Packs ...................................................... 28
13.1 Solo Equipment Pack ......................................................... 28
13.2 Metro Equipment Pack ....................................................... 28
13.3 Caprio Equipment Pack ...................................................... 29
14.0 Spa Overhead Views......................................................... 29
14.1 Solo Overhead View ........................................................... 29
14.2 Metro Overhead View ......................................................... 30
14.3 Caprio Overhead View........................................................ 30
15.0 120/240 VAC 60 Hz Convertible Circuit Diagram ........... 31
16.0 230 VAC 50 Hz Dedicated Circuit Diagram ..................... 32
17.0 Specifications.................................................................... 33
17.1 Solo Specifications ............................................................. 33
17.2 Metro Specifications ........................................................... 35
17.3 Caprio Specifications .......................................................... 37

1.0 Important Spa Owner’s Information

Your Portofino spa is constructed of the highest standards and is capable of providing many years of trouble-free use. However, because heat retentive materials are utilized to insulate the spa for efficient operation, an uncovered spa surface directly exposed to sunlight and high temperatures for an extended period of time is subject to permanent damage. Damage caused by exposing the spa to this abuse is not covered by warranty. We recommend that you always keep the spa full of water when it is exposed to direct sunlight and that you keep the Sundance insulating cover in place at all times when the spa is not in use. Read and carefully follow the requirements for your spa’s support base.
(page 5-6).
Sundance Spas Inc. constantly strives to offer the finest spas avail­able, therefore modifications and enhancements may be made which affect the specifications, illustrations and/or instructions contained herein.
Refer to section 4.0-4.2

2.0 FCC Notice

This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communi­cations. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encour­aged to try to correct the interference by one or more of the follow­ing measures:
1. Rearrange or relocate the receiving antenna;
2. Increase the separation between the equipment and receiver;
3. Connect the equipment into an outlet on a circuit different from
the circuit connected;
4. Consult the dealer or an experienced radio/TV technician for
help.
1
Changes or modifications not expressly approved by the party responsible for FCC compliance could void the user’s authority to operate this equipment.

3.0 Important Safety Instructions

When installing and using this equipment, basic safety precautions should always be followed, including the following:
1. READ AND FOLLOW ALL INSTRUCTIONS BEFORE OPERAT­ING THE SPA!
2. DANGER - RISK OF ELECTRICAL SHOCK. Install spa at least 5 feet (1.5 m) from all metal surfaces. (A spa may be installed within 5 feet (1.5 m) of metal surfaces, if in accordance with the country electrical code).
3. DANGER - RISK OF ELECTRICAL SHOCK. Do not permit any electric appliance such as a light, telephone, radio, or television within 5 feet (1.5 m) of the spa.
4. INSTALLATION - The spa must be installed in such a manner as to provide drainage of the compartment for electrical compo­nents.
5. CAUTION, 240 VAC POWERED SPAS - These spas must be hard wired to your household electrical service box only. Do not use an extension cord or any other disconnectable power cord. The use of an extension cord or a disconnectable power cord is highly dangerous and will void all warranties!
6. A wire connector marked ground “GRN” is provided within the power box. electric shock, connect this terminal or connector to the ground­ing terminal of your electrical service or supply panel with a continuous green insulating copper wire equivalent in size to the circuit conductors supplying this equipment, but no smaller than #8 AWG (8.4 mm2). In addition, a second wire connector is provided for bonding to local ground points. To reduce the risk of electrical shock, this connector should be bonded with a #8 AWG (8.4 mm2) copper wire to any metal ladders, water pipes, or other metal within 5 feet (1.5 m) of the spa.
7. The electrical supply for this product must include a suitably
Refer to section 6.0 (page 8).
To reduce the risk of
2
rated switch or circuit breaker to open all ungrounded supply conductors to comply with the country electrical code.
8. Before entering a spa or hot tub the user should measure the
water temperature with an accurate thermometer since the tolerance of the water temperature regulating device may vary as much as ±5 °F (±3 °C).
9. Always enter and exit the spa slowly and cautiously. Wet
surfaces are slippery.
10. Do not use the spa alone.
11.WARNING - RISK OF CHILD DROWNING. Extreme caution
must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot use a spa or hot tub unless they are supervised at all times.
12. DANGER - To reduce the risk of injury, do not remove any drain
suction gate or cover.
13. Never use the weir gate for sitting or resting your feet. It is
designed to float freely.
14. The water in the spa or hot tub should never exceed 104 °F (40
°C). Water temperatures between 100 °F (38 °C) and 104 °F (40 °C) are considered safe for a healthy adult. Lower water temperatures are recommended for extended use (exceeding 10-15 minutes) and for young children.
15. Since excessive water temperatures have potential for causing
fetal damage during the early months of pregnancy, pregnant or potentially pregnant women should limit spa or hot tub water temperatures to 100 °F (38 °C).
16. The use of alcohol, drugs, or medication before or during spa or
hot tub use may lead to unconsciousness with the possibility of drowning.
17. Persons suffering from obesity or with a medical history of heart
disease, low or high blood pressure, circulatory system prob­lems, or diabetes should consult a physician before using a spa or hot tub.
18. Persons using medication should consult a physician before
using a spa or hot tub since some medications may induce drowsiness while other medications may affect heart rate, blood pressure, and circulation.
19. Long exposures in the spa may result in nausea, dizziness, or
fainting. Observe a reasonable time limit, leave the spa, then shower, cool down, and if you wish, return for another brief stay.
3
20. Excessive temperatures may cause hyperthermia. Symptoms and first aid information are as follows:
HEAT STROKE: The most susceptible people are the very young and elderly, alcoholics, and most people under the influ­ence of drugs, medication and alcohol.
SYMPTOMS: Hyperthermia causes loss of salt, sweating, dizziness, headache, dryness of mouth and nausea, faintness and/or unconsciousness, convulsions, flushed appearance of skin, and rapid pulse and/or weak, shallow breathing.
TREATMENT: Place the victim on his back, head slightly el­evated. Apply wet cloths or ice packs to the head, wrap the body in a sheet, pouring on a small amount of water. Follow with a cool shower or bath. Get medical attention as soon as possible.
21. It is recommended that the following emergency telephone numbers be listed at the nearest telephone: physician, hospital, ambulance and police.
22. Save these instructions!

3.1 General Electrical Safety Instructions

Your new Portofino spa is equipped with the “state-of-the-art” LX-10 equipment system. It contains the most advanced safety and self-protective equipment in the industry. Nonetheless, this spa must be installed properly to insure dependable usage. Please contact your dealer if you have any questions regarding your instal­lation. In the event they are unable to answer your questions, direct your inquiries to Sundance Spas Inc. Please refer to the back of this manual for our address.
Proper grounding is extremely important. Portofino spas are equipped with a current collector system. A pressure-type wire connector is provided outside the control box, located behind the equipment door to permit connection of a bonding wire between this point and any ground metal equipment, metal water pipe or conduit within 5 feet (1.5 m) of the spa, or copper clad grounding rod buried within 5 feet (1.5 m) of the spa. The bonding wire must be at least #8 AWG (8.4 mm
2
) solid copper wire. This is a very important safety assurance feature. Before installing this spa, check with the local electrical authority to insure the installation conforms to local coun­try/area state codes.
4

4.0 Choosing a Location

IMPORTANT: Because of the combined weight of the spa,
water, and users, it is extremely important that the base
upon which the spa rests be smooth, flat, level and capable of uniformly supporting this weight without shifting or settling for the entire time the spa is in place. If the spa is placed on a surface which does not meet these requirements, damage to the skirt and/or the spa shell may result. Damage caused by improper support is not covered under the manufacturer’s warranty. It is the responsibil­ity of the spa owner to assure the integrity of the support at all times.
We recommend a poured, reinforced concrete slab with a minimum thickness of 4 inches (10 cm). Wood decking is also acceptable, provided it is constructed so that it meets the requirements outlined above. The spa must be installed in such a manner as to provide drainage away from the spa. Placing the spa in a depression without provisions for proper drainage could allow rain, overflow and other casual water to flood the equipment and create a wet condition in which it would sit.
For spas which will be recessed into a floor or deck, install so as to permit access to the equipment, either from above or below, for servicing. Make certain that there are no obstructions that would prevent removal of the cabinet side panels, especially on the side with the equipment pack. Make sure provisions are made for drain­ing the spa.

4.1 Outdoor Location

In selecting the ideal outdoor location for your spa, we suggest that you take into consideration:
1. The proximity to changing area and shelter around spa (espe-
cially in colder weather).
2. The pathway to and from your spa (this should be free of debris
so that dirt and leaves are not easily tracked into the spa).
3. Closeness to trees and shrubbery (remember that leaves and
birds could create extra work in keeping the spa clean).
4. A sheltered environment (less wind and weather exposure can
result in lowered operation and maintenance costs).
5. The overall enhancement of your environment.
6. It is preferable not to place the spa under a gutter-less roof
overhang since runoff water will shorten the life expectancy of the spa cover.
5

4.2 Indoor Location

For indoor installations, be certain to make provisions for proper ventilation. When the spa is in use, considerable amounts of mois­ture will escape. This can damage various surfaces over time. A dehumidifier can help control the moisture in the room. If you have any questions regarding the placement or installation of your spa, consult your authorized Portofino dealer.
120/240 Volt Convertible Models
A spa connected to a 120 VAC electrical service must be located close enough to a grounded, grounding-type electrical outlet so that the included power cord can be plugged directly into it. DO NOT USE AN EXTENSION CORD as this could cause damage to the spa’s equipment due to insufficient voltage. The power supplied to this spa must be a dedicated circuit with no other appliances or lights sharing the power provided by the circuit.

5.0 Power Supply Requirements

All US/Canada 120/240 VAC Convertible Models (60 Hz)
120 VAC/ 240 VAC/ 240 VAC/
15 A* 30 A* 40 A**
Voltage: 120 VAC 240 VAC 240 VAC Frequency: 60 Hz 60 Hz 60 Hz Current Draw: 12 A 21 A 30 A # of Wires 3 (15 A cord/GFCI) 4 4 Circuit Breaker 15 A, 1-Pole 30 A, 2-Pole 40 A, 2-Pole
For 240 VAC Heater Operation: Move the red wire on the main terminal strip (TB1) from position #1 to position #3. Make certain wires are con­nected exactly as shown in figure-H (page 8) before applying power. Failure to do so will result in damage to the circuit board and/or related components and void the manufacturer’s warranty.
* In the 15 A / 30 A configuration, the heater will not operate at the
same time as the high-speed jets pump. The factory setting is
120 VAC/15 A.
** If the spa is to be operated on 40 A service, remove the jumper JP1
#1&2 on the circuit board to allow the heater to operate at the same time as the high-speed jets pump (see page 31).
6
All Export 230-240 VAC Models (50 / 60 Hz)
230VAC/ 230VAC/
20 A* 30 A**
Voltage: 230 VAC 230 VAC Frequency: 50 / 60Hz 50 / 60Hz Current Draw: 13A 19A # of Wires: 3 3 Circuit Breaker: 20 A 30 A
* In the 20 A configuration, the heater will not operate at the same
time as the main jets pump. This is the factory setting.
** In the 30 A configuration, the heater will operate at the same time as
the main jets pump.
Important Information: The Portofino series spa can be adapted to use higher amperage circuits when available. Please contact your dealer for details. The electrical supply for this product must comply with local electrical regulations.
7

6.0 Electrical Wiring Instructions

Important Notice: The electrical supply to this product
must be installed by a qualified, licensed electrician to comply with all regulations and standards specified by the electrical authority in your state or country.
1. A 240 VAC powered spa must be permanently connected (hard­wired) to the power supply. No plug-in connections or extension cords are to be used in conjunction with the operation of this spa. Supplying power to the spa which is not in accordance with these instructions will void both the independent listing and the manufacturer’s warranty.
2. The power supplied to this spa must be a dedicated circuit with no other appliances or lights sharing the power provided by the circuit.
3. To gain access to the spa’s power terminal strip, remove the spa’s cabinet panel on the light side of the spa. Then remove the faceplate from the load box. Refer to sections 13.1-13.3 (page 28-29) for your specific spas load box location.
4. Locate the hole in the cabinet (above the pan) and feed the wires through (Solo spa only).
5. Connect the wires to main terminal block TB1. Refer to figures G-I for your specific spas terminal block configuration. Tighten securely! All wires must be hooked up or damage could result.
6. The electrical supply for this product must include an electrical installation and circuit breaker that complies with local electrical regulations.
7. A suitably rated GFCI or RCD must be installed at the power supply in the house electrical box.
8. Reinstall the face plate and the cabinet panel.
fig. G
Power In
All US/Canada Convertible Models: 120 VAC, 3-Wire Connection (60 Hz)
WHT
BLK
TB1
1
2
3
GRN
8
WHT
RED
BLK
BLK
to Circuit Board
fig. H
Power In
All US/Canada Convertible Models:
120/240 VAC, 4-Wire Connection (60 Hz)
WHT
BLK
RED
1
2
3
GRN
TB1
WHT
BLK
BLK
RED
to Circuit Board
fig. I
TB1
1
2
Power In
230-240 VAC, 3-Wire (50/60 Hz)
GRN
All Export Models:
BLUE
BLUE
BROWN
BROWN
to Circuit Board

7.0 Start-Up Instructions

Congratulations! You are now all set to get your new spa ready to use. Simply follow this step-by-step procedure and, before long, you will be enjoying your first glorious experience in your Portofino spa. For best results, read each step in its entirety before proceeding with that step.
series of start-up displays. Refer to section 9.0 (page 12) for additional information.

7.1 Filling the Spa

Clear all debris from the spa. Although the spa shell has been polished at the factory, you may want to treat it with a specially formulated spa cleaner. For more information, consult your dealer prior to filling it. Only spas with a smooth acrylic surface require waxing. It is not necessary to wax spas with the textured Quarite™ surface.
During power-up, the control panel will display a
Remove the filter cover, then remove the filter cartridge as outlined in section 10.1 (Page 17-18). Place the end of your garden hose into the filter compartment, then fill spa. For Solo models only - fill the spa with water from a garden hose until the water level is just below the neck jets.
Refer to section 14.1 (page 29).
For Metro and
Caprio models, fill until water level is halfway up the filter skimmer.
Refer to sections 14.2-14.3 (page 30).
Do not overfill. Never fill with water from a water softener. If your water is extremely “hard”, it is preferable to fill half way with hard water and the rest of the way with softened water. Or, you may fill entirely with hard water if you use a special water additive available from your Portofino dealer.
9
Always refill with garden hose in filter compartment. This helps to purge trapped air from pump intakes. Failure to do so may cause air to be trapped in either pump 1 or the circulation pump’s intake (air lock), preventing either pump from circulating water. After filling, make sure the filter is installed properly before applying power to the spa.
Refer to section 10.1 (Page 17-18) “Cleaning the Filter” for
specific cleaning and installation instructions.
Solo Models Only - For installations that do not incorporate perma­nent drain plumbing, we recommend that you seal off the overflow plumbing by removing the s/s overflow fitting and install the provided plug and O-ring. the water from entering the overflow pipe, and prevents it from stagnating between draining periods.
Refer to section 13.1 (page 28).
This option stops

7.2 Safety Check

Open the cabinet access panel and check the pump unions to make sure they are hand tight. Loosening can occur during shipping and handling. Solo models only - turn the drain valve off.
Refer to sections 13.1-13.3 (page 28-29).
Refer to section 13.1 (page 28).

7.3 Initiating Water Circulation

Depress the JETS button on the control panel. This causes the pump to activate water flow to the jets. If the pump is properly primed, you should be able to feel a steady flow of water through at least some of the jets.
After draining and refilling the spa, it is possible that the pump does not prime adequately. Trapped air in the plumbing system can be the reason for loss of prime. In this case, turn off power to the spa and loosen the cap of the Massage Selector and carefully let trapped air escape from the plumbing.
(page 29-30).
it is tight before turning power on and starting the pump.
Screw the massage selector cap shut and make sure
Refer to section 14.1-14.3

7.4 Adding Start-Up Chemicals

Add the spa water chemicals as recommended by your Portofino dealer.
Quality” for general guidance.
10
Refer to section 10.9 (page 22) “Maintaining the Water

8.0 Control Panel Functions

A
B
C
D
E
F

Panel Functions:

A. Heat Indicator: lit when
heater is on.
B. Warmer Button:
increases water temperature setpoint.
*Display shown for example purposes only,
C. Cooler Button:
decreases water temperature setpoint.
D. LED Display: can display current water temperature (default
display*), water temperature setpoint, selected filtration mode, and error messages.
E. Light Button: turns underwater light on and off.
F. Jets Button: turns jets on and off. Press once for low speed;
press a second time for high speed; press a third time to turn off.
actual water temperature display will vary.

Operation Details:

•Temperature Adjustment: 65 to 104 °F (18 to 40 °C). Software
default setting is 100 °F (38 °C).
• Underwater Light Operation: light runs for 1 hour then shuts off for
increased bulb life.
• JETS button Operation: jets run for 20 minutes after activated
then turn off automatically to conserve energy. Simply press JETS button to continue operation for an additional 20 minutes.
11

9.0 Operating Instructions

The spa control system has automatic functions that operate upon start-up and normal operation to protect the system. Upon power up, the readout displays the following information:
1. Control displays current software release (e.g. 3.54), then;
2. Control panel displays “888” and all indicator LEDs are lit, permitting visual inspection of all display segments and indicator lights for proper operation.
3. After the initial start-up sequence ends actual water temperature is displayed. If water temperature at this time is less then the factory default temperature setting of 100 °F (38 °C), the circulation pump and heater will turn on and run until the water temperature rises to the factory default temperature setting. Then the heater turns off and the circulation pump remains on for 24-hour operation.
Note: it is common for the heater to turn on
Startup
Sequence
1.
2.
3.
after the spa is first filled because tap water is often very cold.

9.1 Setting Water Temperature

The spa’s thermostat provides optimum control of water temperature. The temperature setpoint (set temperature) can be adjusted from 65 °F to 104 °F (18 °C to 40 °C). To raise the set temperature, press the WARMER arrow button. To lower the set temperature, press the COOLER
or COOLER button displays the set temperature.
arrow button.
Note: The first press of either WARMER

9.2 Pump Button

The JETS button activates the functions of the pump. The first press activates low speed, the second press activates high speed, and the third press shuts the pump off. The pump has a twenty-minute default when manually activated.

9.3 Light Button

The LIGHT button activates the spa light when pressed.
12

9.4 Solo Massage Selector / Air Control Operation

Air Controls Functions:
Air Controls A-C Open An Air
A
A
Venturi to Specified Jets:   = Jets A
A
 = Jets B
B
 = Jet Group C
C
Massage Selector Functions:
Z
 Diverts Water Flow Between Jet
A
B
A
B
Z
B
C
C
B
Group C and Jets A&B

9.5 Metro Massage Selector / Air Control Operation

Air Controls Functions:
Air Controls A&B Open An Air Venturi to Specified Jets:
A
 = Jets A  = Jets B
B
Massage Selector Functions:
 Diverts Water
Z
Flow Between Jet Group A and Jets B
A
A
A
B
B
B
B
Z
A
13

9.6 Caprio Massager / Air Control Valve Operation

Air Controls Functions:
Air Controls A-C Open An Air Venturi to Specified Jets:
= Jet Group A
A
= Jet Group B
B
= Jet Group C
C
A
Z
Massage Selector Functions:
Diverts Water Flow Between Jet Group
Z
A and Jets D.
Jet Groups B & C Are Always On. However, The Jet Faces of These Jets Can be Adjusted to Personal Preference Levels.
A B
D
B
14
D
C
D
C

9.7 Filtration Options

Your new spa includes a 24-hour circulation pump which filters the water continuously while using less energy than a common 100 watt light bulb! The circulation pump draws water through the short side of the double-ended filter cartridge and effectively removes small debris in your spa.
Note: the 24-hour circulation pump system also supplies heated water to the spa when the heater turns on. This features cannot be altered or disabled.
The control system activates a programmable “standard” or “economy” skimming/heating cycle to remove larger debris missed by the 24-hour circulation pump filtration system. These cycles utilize pump#1 and the larger filter cartridge end to quickly clear “skim” the water of large debris and minimize their “bathtub ring” effect. Apart from their skimming benefit, each mode also effects the operation of your spa’s heater. Refer to sections 9.8 and 9.9 below for additional information.

9.8 Standard Skimming/Heating Modes (F0 - F3)

Standard skimming/heating modes are typically selected by custom­ers in cold climates where heatup times are extended due to lower ambient temperatures. In these modes, the water temperature is regulated by the set temperature, 24-hour circulation pump, and heater which turns on as needed. After the programmed set tem­perature is reached, the heater turns off and the circulation pump continues to operate 24-hours to filter and clean your spa.

9.9 Economy Skimming/Heating Modes (F4 - F6)

Economy skimming/heating modes are typically selected by custom­ers in warm climates where heatup times are minimized due to higher ambient temperatures. In these modes, the water tempera­ture is regulated by the set temperature, 24-hour circulation pump, and heater only while a programmed filter cycle is running (unless in summer logic; see section 11.1, page 24).
Note: these modes consume far less energy than standard modes F0-F3 outlined above.

9.10 Lock Modes (L1 - L2)

These modes are designed for use during spa service or to prevent unauthorized use.
15

9.11 Selecting The Skimming/Heating Mode

Press and hold both control panel WARMER and COOLER buttons at the same time, then release. Then press either WARMER or COOLER button to select skimming/heater mode F0-F6 or lock modes L1-L2 below:
Standard Skimming/Heating Modes F0 5 minutes of skimming per day (one 5 minute
“Blow-Out” cycle every 24 hours to purge all plumbing lines)
F1 1 hour of skimming per day (one 30-minute
cycle every 12 hours); this is the factory default setting.
F2 1.5 hours of skimming per day (one 30-minute
cycle every 8 hours)
F3 2 hours of skimming per day (one 30-minute
cycle every 6 hours)
Economy Skimming/Heating Modes F4 1 hour of skimming/heating per day (one
30-minute cycle every twelve hours)
F5 1.5 hours of skimming/heating per day (one
30-minute cycle every eight hours)
F6 2 hours of skimming/heating per day (one
30-minute cycle every six hours)
Lock Modes L1 Lock Out (disables all spa functions to permit
filter cleaning)
L2 Lock Mode (disables the jets and light buttons to
prevent unauthorized use of spa.) Skimming/ heating cycle will continue to operate as programmed in this mode. The temperature display flashes when this function is enabled.
Example: the “F3” skimming/heating cycle was enabled prior to choosing lock mode. The spa continues to perform the “F3” cycle until lock mode is canceled, allowing another cycle to be selected.
16
To set a time for the first skimming/heating cycle, simply turn power on to the spa two minutes prior to the desired time.
EXAMPLE: If you desire your first skimming/heating cycle to begin at 10:00 AM turn off power to the spa and turn it back on again at 9:58 AM. Note: start time is approximate and may vary slightly from day to day.

10.0 Care And Maintenance

Proper and regular maintenance of your spa will help it retain its beauty and performance. Your authorized Portofino dealer can supply you with all the information, supplies and accessory products you will need to accomplish this.

10.1 Cleaning The Filter

Solo Models - These models are equipped with a double-ended
polyester mesh (pleated) filter cartridge under the filter lid
14.1, page 29).
drawing water through the smaller side of the cartridge. Larger debris are filtered by the main 2-speed pump drawing water through the larger side of the cartridge during normal operation and during each skimming/heating cycle. Combined, both halves work together to give you clean water by trapping suspended particles on their outer surface.
Debris are filtered 24-hours by the circulation pump
Note: To ensure optimum performance, clean and
reuse the filter cartridge once a month.
(section
Metro and Caprio Models - These models are equipped with an exclusive MicroCleanTM 2-stage filter cartridge located under the filter lid hours by the circulation pump drawing water through the ultra-fine (stage 2) cartridge. Larger debris are filtered by the main 2-speed pump drawing water through the (stage 1) polyester mesh (pleated) cartridge during normal operation and during each skimming/heating cycle. Combined, both filter halves work together to give you unsur­passed water quality by trapping suspended particles on their outer surface.
(section 14.2-14.3, page 30)
. Fine debris are filtered 24-
Note: To ensure optimum performance, clean and reuse the stage 1 cartridge once a month and replace the stage 2 car­tridge every 3 months, or as needed.
17
ALWAYS TURN POWER TO HOT TUB OFF BEFORE CLEANING THE FILTER CARTRIDGE!
Refer to the filter cleaning/replacement
procedure below.
A
TURN POWER TO HOT TUB OFF!
B
Filter Nut
Loosen filter nut to provide clearance, then remove filter assembly.
To p
To p
All Models
Solo Filter
Metro and Caprio (Stage 1) Filter
D
Rinse debris from all filter pleats using a garden hose and high-pressure nozzle. Start at top and work downward to face. Repeat process until all filter pleats are clean.
C
1. Rotate stage 2 retainer counterclockwise
2. Replace (throw-away) stage 2 filter after 3
E
1. Install new stage 2 filter onto clean stage 1 filter.
2. Insert retainer into stage 2 filter and rotate
Metro and Caprio Models OnlyAll Models
Replace! DO NOT
Reuse!
1.
to release, then separate filter assembly.
months use or as needed. DO NOT reuse!
clockwise to assembly. DO NOT overtighten retainer (finger tight only).
2.
Stage 2
filter
Metro and Caprio Models Only
1.2.
New
Stage 2
filter
Stage 1
filter
(Reuseable)
Stage 1
filter
F
Submerge assembled filter in spa and tilt each end upward to remove trapped air bubbles from inside each filter cavity.
All Models
Tr apped
Air
Bubbles
18
G
1. Install filter assembly, then tighten filter nut so it just touches filter face. DO NOT OVERTIGHTEN!
2. Turn power to hot tub back on.
All Models
Filter
Nut
Periodically, the polyester mesh (pleated) filter will need a more thorough cleaning to remove imbedded oils and minerals. For this, we suggest cleaning as illustrated above (step D), followed by soaking the filter overnight in a plastic container filled with a solution of water and a specially formulated filter cleanser available from your Portofino dealer.
CAUTION! Never scrub the polyester mesh filter cartridge with a brush as this will cause the polyester mesh to wear out and come apart. Never let the spa pump run or have a filter cycle come on without a filter cartridge in the skim­mer compartment. Running the spa without a filter car­tridge may permit debris to enter the spa plumbing and void the warranty!
The average life expectancy of the polyester mesh filter cartridge is approximately two years with proper care and water quality maintenance. The smaller stage 2 filter cannot be cleaned and must be replaced (thrown-out) every 3-months, or as needed. DO NOT reuse this cartridge! Attempts to reuse this cartridge will reintroduce debris back into your spa! Replacement cartridges may be purchased from your Portofino dealer.

10.2 Draining And Refilling

WARNING: Read This Before Draining
To prevent damage to the spa’s components, turn off power to the spa at the circuit breaker before draining it. Do not turn power back on until your spa has been refilled.
CAUTION: There are certain precautions to keep in mind when draining your spa. If it is extremely cold, and the spa is outdoors, freezing could occur in the plumbing or the equipment. On the other hand, if it is hot outdoors, do not leave the spa’s surface exposed to direct sunlight for long periods.
19
To drain Solo model, first, shut off the power to the spa. Next, re­move the drain cap, then open the equipment access panel and locate the drain valve and turn handle to open.
(page 28).
power to the spa. Pull the external drain cap from the wood skirt (attached to it is a drain hose) and continue pulling upward until it is above the water line. Connect garden hose and drain spa. After draining spa, refer to section 7.1 (page 9) for filling instructions.
To drain Metro and Caprio models, first, shut off the
Refer to section 13.1

10.3 Cleaning The Spa Interior

To preserve the sheen of your spa’s surface, it is crucial that you avoid using abrasive cleaners or cleaners which have adverse chemical effects on the surface. If you are not certain about the suitability of a particular cleaner, please consult your authorized Portofino dealer. Regardless of the cleanser used, use extreme care to assure that no soap residue is left on the surface. This could cause foaming when the spa is refilled.

10.4 Cleaning The Pillows

Remove and clean the headrest pillows as needed with soapy water using a cloth or soft-bristle brush. To maintain water resistance and luster, apply a quality vinyl conditioner once a month. Always re­move the pillows when adding chemical shock treatment to the hot tub water. The pillows can be returned to the hot tub when the sanitizer reading drops below 5 ppm.
IMPORTANT: Never attempt to remove the pillows by pulling on them! The pillows utilize a bolt-on design that prohibits removal without tools.
To remove pillows:
1. Grasp center pillow insert (A) with finger tips and gently pry outward from pillow base (C).
2. Use a standard screwdriver to loosen and remove mounting bolts (B) from pillow base.
3. Assemble in reverse order after cleaning. DO NOT overtighten pillow mounting bolts!
20

10.5 Maintaining The Cover

Using the Portofino insulating spa cover anytime the spa is not in use will significantly reduce your operating costs, heat-up time and maintenance requirements. To prolong the life of the cover, handle it with care and clean it regularly using mild soap and water. Periodic treatments with a special conditioner developed for Sundance spa covers will help protect against deterioration caused by UV rays from the sun. Never allow anyone to stand or sit on the cover, and avoid dragging it across rough surfaces.

10.6 Maintaining The Wood Cabinet

With time and exposure to the elements, the wood on your spa will tend to lose its new appearance. Protecting or reviving the wood surface is a fairly simple process. Light sanding with fine-grit sand­paper will help smooth any roughness. Regular applications of a penetrating wood preservative will enhance and protect the richness of the wood. A specially formulated wood stain available from your Sundance dealer is ideal for this job.
shellac or other surface sealant to the wood. These tend to react with the chemicals in the wood and the UV rays of the sun, causing yellowing, flaking and peeling.
Note: Do not apply varnish,

10.7 Maintaining The Synthetic Cabinet

Your new spa’s synthetic cabinet requires little or no maintenance of any kind. To clean, simply wipe cabinet with a clean towel and mild soap solution.
CAUTION: Never spray cabinet with a garden hose for any reason since this action may induce an electrical short in the spa’s electrical equipment.

10.8 Winterizing The Spa

Your Portofino spa is designed to automatically protect itself against freezing when operating properly. During periods of severe freezing temperatures, you should check periodically to be certain that the electrical supply to the spa has not been interrupted. If you do not intend to use your spa, or if there is a prolonged power outage
21
during periods of severe freezing temperatures, it is important that all water be removed from the spa and equipment to protect against damage from freezing. For expert winterization of your spa, contact your authorized Portofino dealer.

10.9 Maintaining Water Quality

Maintaining the quality of the water within specified limits will serve to enhance your enjoyment and prolong the life of the spa’s equip­ment. It is a fairly simple task, but it requires regular attention because the water chemistry involved is a balance of several
factors. A careless attitude in regard to water maintenance will
result in poor and potentially unhealthy conditions for soaking and even damage to your spa investment. For specific guidance on maintaining water quality, consult your authorized Portofino dealer who can recommend appropriate chemical products for sanitizing and balancing your spa water.
CAUTION: Never store spa chemicals inside the spa’s equipment bay.

10.10 Controlling pH

pH is a measure of relative acidity or alkalinity of water and is measured on a scale of 0 to 14. The midpoint of 7 is neutral, above 7 is alkaline, and below 7 is acidic.
In spa water, it is very important to maintain a slightly alkaline condition of 7.2 to 7.8. Problems become proportionally severe when this range is exceeded or diminished. A low pH will be corro­sive to metals in the spa equipment. A high pH will cause minerals to deposit on the interior surface of the spa and equipment (scaling). In addition, the ability of the sanitation agents to keep the spa clean is severely affected as the pH moves beyond the ideal range. Your Portofino dealer can provide you with any chemicals and instruc­tions you may need to adjust the pH of your spa water.
22

10.11 Sanitizing / Using Additives

To destroy bacteria and organic compounds in the spa water, a sanitizing agent must be used regularly. Consult your Sundance dealer for specific sanitizing instructions.
IMPORTANT: Do not use Trichlor in your spa. This chemical can have an extremely corrosive effect on certain materials in the spa. Damage caused by use of this chemical, or improper use of any chemicals, is not covered under the manufacturer’s warranty. Many other additives are available for your spa. Some are necessary to compensate for out-of-balance water, some aid in cosmetic water treatment, and others simply alter the feel or smell of the water. Your authorized Portofino dealer can advise you on the use of these additives.
23

11.0 Error Conditions / Error Messages

11.1 Summer Logic

When the actual spa water temperature reaches up to 2 °F (1 °C) above the set temperature, the spa goes into “summer logic.” The circulation pump will turn off automatically to avoid adding additional heat to the water, eventually creating an overheat condition. This setting is not user-programmable.
effect until the spa water temperature reaches 95
Note: The summer logic does not take
°
F (35 °C).
11.2 Overheat Condition
WARNING! DO NOT ENTER HOT TUB WATER!
Water is too hot. Overheat protection. Heater is deactivated. Spa water temperature is above acceptable limits. When the actual water temperature is approximately 2 °F (1 °C) above the set temperature, the circula­tion pump will stop operating to reduce (frictional) heating. If the spa water temperature continues to rise and gets above 112 °F (44 °C), the spa will go into an “OH” overheat condition.
To Correct Condition:
1. Remove the spa’s cover and allow your spa to cool down.
2. Reduce the temperature setting.
3. When the water temperature drops below 106 °F (41 °C), the spa will resume normal operation.
4. If the water does not drop below 106 °F (41 °C), contact your authorized dealer.
There are a number of unique functions designed into your spa to protect it from damage and/or aid in troubleshooting. Refer to sections 11.3-11.8 below for a listing of all possible error messages and their meanings.
OH
11.3 Panel displays
Open sensor (heater is disabled) or shorted sensor (spa is deactivated). The high-limit temperature
24
SN1
sensor is not functioning. Your authorized dealer must repair this.
11.4 Panel displays
Open or shorted sensor (heater disabled). The temperature sensor is not functioning. Your authorized
dealer must repair this.
SN2

11.5 Panel displays FL1 or FL2

A flashing “FL1” display means the flow switch is malfunctioning open; a flashing “FL2” display means the flow switch is malfunctioning closed.
Flow switch has malfunctioned.
Heater is deactivated. Pump may also be deactivated.
Proper flow of water is inhibited, or the flow switch has malfunctioned.
To Correct Condition:
1. Remove filter and allow air to bleed out of cartridge.
2. Check for proper water level.
3. Check for clogged/excessively dirty filter cartridge.
4. Check secondary screen filter (Solo models only).
5. Check for sticking or damaged weir gate.
6. If problem persists, contact your authorized dealer.
Note: This message can also appear if the pump has not regained prime after the spa has been drained and refilled. If you suspect this is the case, refer to section 7.3, page 10.
11.6 Panel displays
Cool Condition - Temperature has dropped 20 °F (11 °C) below the current set temperature. The pump and heater have been activated to bring the temperature to within 15 °F (8 °C) of the set tempera­ture. No corrective action is required.
COL
25
11.7 Panel displays
Freeze Protection - A potential freeze condition has been detected. No action is required. Main pump will operate to circulate warm water through the plumbing until the spa is out of danger.
ICE

11.8 Panel Displays - - -

The safety “Watchdog” software has been triggered and the spa is deactivated. A problem has been detected which could cause damage to the spa or its components. Contact your authorized dealer.

12.0 Troubleshooting Procedures

In the event your Portofino spa is not working the way it should, please first review all the installation and operating instructions in this manual and check the message on the panel display. If you are still not satisfied it is working properly, please follow the appropriate troubleshooting instructions.
accessories are damaged, they must be replaced by authorized service personal.
Note: If any of the supply cords to the

12.1 No Components Operate (e.g. Pump, Light)

Check the following:
1. Is there power to the spa?
2. Is the household circuit breaker tripped?
3. Call your authorized dealer.

12.2 Pump Does Not Operate But Light Does

Press the JETS button:
1. If no water movement is detected, make sure power is going to the spa and check the water level. If it does not solve the prob­lem, contact your authorized Portofino dealer.
2. The main pump operates but no water flows to jets. Pump may not be properly primed. This can happen after the spa is drained and refilled. Press the JETS Button several times, never leaving the motor on for more than 5 to 10 seconds at-a-time. Turn power off and let the air out by loosening the cap on the diverter and/or remove the filter.
26
Refer to section 7.3 (page 10).
Make
certain you tighten the diverter cap and/or reinstall the filter before turning on spa power and restarting the pump.

12.3 Poor Jet Action

1. Press the JETS button to make certain the pump is on.
2. Rotate the air control to the “on” position.
3. Solo Models Only - make certain that the water level is to below the neck jets.
4. Check for dirty filter. Clean, if necessary.
5. Make sure jets are all the way open.
just

12.4 Water is Too Hot

Reduce thermostat setting so the circulation pump turns off.

12.5 No Heat

1. Check thermostat setting.
2. Keep the spa cover in place while heating.
Your authorized dealer is a trained service repair center. Should checking the above steps fail to correct the problem, please call your dealer so that they may arrange service.
We build the best spas in the industry. Nonetheless, we are always striving to improve the quality and features of our products. Your input as a Sundance Portofino spa owner is a cherished part of this process. If you have any comments or suggestions, or if you wish to be informed on any new products for your spa, please write to us.
CONGRATULATIONS on your good taste and welcome to the happiest and most relaxed family in the world!
27

13.0 Spa Equipment Packs

13.1 Solo Equipment Pack

1. Overflow Fitting
2. Drain Cap
3. Auxiliary Pan Drain Location
4. Load Box
5. Safety Screen and Heater Intake
6. Drain Valve
7. Heater
8. Circulation Pump
9. Main Pump
10. Filter
11. Pan
3
2
12. Wood Frame
13. Pump Unions

13.2 Metro Equipment Pack

1. Load Box
2. Heater
3. Circulation Pump
4. Main Pump
5. Pump Unions
12
13
1
5
10
8
11
1
3
6
7
4
9
4
28
5
2

13.3 Caprio Equipment Pack

1. Load Box
2. Heater
3. Circulation Pump
1
4. Main Pump
5. Pump Unions

14.0 Spa Overhead Views

14.1 Solo Overhead View

1. Overflow
2. Control Panel
3. Air Controls
4. Massage Selector
5. Skimmer Weir
6. Filter
7. Neck Jets
8. Filter Nut
9. Safety Screen (Located Inside Filter Wall Fitting)
121.92 cm (48")
5
9
6
Equipment Access Side - Do Not Obstruct
5
180.34 cm (71")
3
1
8
3
4
2
7
4
3
2
29
223.52 cm (88")
200.66 cm (79")
Equipment Access Side - Do Not Obstruct
5
3
6
3
4
2
1
7
3

14.2 Metro Overhead View

1. Control Panel
2. Air Controls
3. Massage Selector
4. Filters
5. Neck Jets
6. Skimmer Weir
7. Filter Nut
8. Safety Screen (Located Inside Filter Wall Fitting)
163 cm
(64")
5
6
4
213 cm (84")
2 2
3
1

14.3 Caprio Overhead View

1. Filter Nut
2. Control Panel
3. Air Control
4. Massage
5. Filters
6. Neck Jets
7. Filter Pipe
Selector
7
Equipment Access Door
8
Do Not Obstruct
30

15.0 120/240 VAC Convertible Circuit Diagram

Ozonator
O
3
GRN
TB1
Standard 120 VAC 3-Wire Connection
(60 Hz, 1 Phase, 15 A Service)
Use copper conductors ONLY. Wire size must be
appropriate per NEC and/or local codes.
WHT
WHT
WHT
WHT
WHT
BLK
BLK
RED
BLK
BLK
BLK
BLK
BLK
RED
RED
RED
BLK
321
Heater
1.0 kW @ 120 VAC
4.0 kW @ 240 VAC
Flow Switch
Hi-limit/Freeze
Sensor
Temperature Sensor
J2
J3
F1
20A
250V
SC-20
Circ.
Pump
Main
Pump
Spa Light
Transformer
120 VAC
J4
BLK
RED
*
GRN
TB1
WHT
BLK
RED
321
Optional 120/240 VAC
4-Wire Convertible
Heater Connection
1. Remove and discard the
factory installed GFCI Cord.
2. Move RED
*
wire from TB1
position #1 to TB1 position #3
as shown below.
3. Permanently connect to
the power supply.
Use
copper conductors ONLY.
Wire size must be
appropriate per NEC and/or
local codes.
4. If hot tub is to be operated
on 30A service, make sure
the jumper provided at
location JP1 #1&2 on the
circuit board is installed. If
hot tub is to be operated on
40A service, remove the
jumper JP1 #1&2 on the
circuit board.
HILO
JP1
4
2
3
1
65
87
Logic Jumper Settings (Factory Defaults Shown)
JP1 1-2 ON = 15A Logic (3-wire 120 VAC operation only)
JP1 1-2 ON = 30A Logic (4-wire 120/240 VAC operation only)
JP1 1-2 OFF = 40A Logic (4-wire 120/240 VAC operation only)
JP1 7-8 ON =
°C Temperature Display
JP1 7-8 OFF =
°F Temperature Display
J20
J21
J12
J14
J16
J11
J15
J13
J17 J7 J8 J9 J10
J5
J6
Heater IN Heater OUT
F1*
K1
K2
K3
K4
K5 K7 K8
J1
Control
Panel
This wiring diagram is used for all US/Canada convertible power Caprio, Metro, and Solo Models with 120/240 VAC (60 Hz) power requirements.
31

16.0 230VAC 50Hz Dedicated Circuit Diagram

Ozonator
O
3
TB1
230 VAC, 3-Wire Connection (50 Hz, 1-Phase Service)
USE COPPER CONDUCTORS ONLY. WIRE SIZE MUST
BE APPROPRIATE PER NEC AND/OR LOCAL CODES
21
Flow Switch
Hi-limit/Freeze Sensor
Temperature Sensor
J2
J3
F1
20A
250V
SC-20
Circ.
Pump
Main
Pump
Spa
Light
Transformer
230 VAC
J4
HILO
GRN
Export 230 VAC 50 Hz
Power Connections
Logic Jumper Settings
All Models:
JP1 1-2 ON = 20A Logic*
JP1 1-2 OFF = 30A Logic
*Factory Jumper Setting
Temp. Jumper Settings (All Models):
JP1 7-8 ON = °C Temp Display
JP1 7-8 OFF = °F Temp Display
N
L
JP1
4
2
3
1
65
87
Heater
2.7 kW @ 230 VAC
J20
J21
J12
J14
J16
J11
J15
J13
J17 J7 J8 J9 J10
J5
J6
Heater IN Heater OUT
F1
K1
K2
K3
K4
K5 K7 K8
BLK
WHT
BRN
BRN
BLU
BLU
BLU
BRN
BRN
BLK BLU BRN BLU BRN
J1
Control Panel
This wiring diagram is used for all Export Caprio, Metro, and Solo Models with dedicated 230 VAC (50 Hz) power requirements.
32

17.0 Specifications

17.1 Solo Specifications

• Dimensions: 48” x 71” x 29”
(122 cm x 180 cm x 74 cm)
• Seating Capacity: 1 Adult
• Dry Weight: 401 lbs / 182 kg
• Filled Weight: 1,238 lbs / 562 kg
•Water Capacity (Avg. Fill): 100 US Gal / 380 Liters
• Controls: Solid-State Electronic Controls with LED Readout,
Programmable Temperature, Filtration, and Heat Cycles
•Water Delivery: 1 TheraFlo
TM
High-Flow Pump
• Pump 1 Rating:
- US/Canada Convertible Model (60 Hz): 2-Speed /1.5 hp Continuous, 13.6 A Max.
- Export Models (50/60Hz): 2-Speed/2.0 hp Continuous,
8.7 A Max.
• Pump 2: Circulation Pump
•Total Hydrojets: 24
• Therapy Jets: 4 Pro-Touch II
•Vertical Jets: 6 PulsatorTM, 2 Accu-Pressure
TM
TM
• Accu-Ssage Therapy Seat Jets: 12 Accu-Pressure
• Air Controls / Massage Selectors: 3 / 1
33
• Filter: Double-End Cartridge, 20” Slipstream Automatic Brominator
TM
TM
•Water Treatment: Brominator Chemical Feeder
Weir with
• Lighting: Underwater with Two Colored Lenses; Optional SunGlow
TM
Multi-Color LED Light Kit
• Handrails: 2 High Quality Stainless Steel
• Pillows: 2-Part/2-Tone Gray, Bolt-on; Optional Blue or Camel
Insert
• Heater:
- US/Canada Convertible Model (60 Hz): Low Flow, 1 kW @ 120 VAC or 4 kW @ 240 VAC
- Export Models (50/60 Hz): Low Flow, 2.7 kW
• Electrical Requirements:
- USA/Canada Convertible Model (60 Hz): 120 VAC @ 15 A or 240 VAC @ 25 A or 40 A
- Export Models (50/60 Hz): 230 - 240 VAC @ 20 A or 30 A; or suitably rated circuit breaker to comply with local electrical regulations. Certain countries may require dual power inputs; two 16 A and breakers are required for this configura­tion.
34

17.2 Metro Specifications

• Dimensions:
-With Wood Cabinet: 64” x 84” x 30.5” (163 cm x 213 cm x 78 cm)
- With Synthetic Cabinet: 62” x 82” x 30.5” (157 cm x 208 cm x 78 cm)
• Seating Capacity: 2 Adults
• Dry Weight: 498 lbs / 226 kg
• Filled Weight: 2083 lbs / 945 kg
•Water Capacity (Avg. Fill):
190 US Gal / 719 Liters
• Controls: Solid-State Electronic Controls with LED Readout, Programmable Temperature, Filtration, and Heat Cycles
•Water Delivery: 1 TheraFlo
TM
High-Flow Pump
• Pump 1 Rating:
- US/Canada Convertible Model (60 Hz): 2-Speed/1.5 hp Continuous, 13.6 A Max.
- Export Models (50/60 Hz): 2-Speed/2.0 hp Continuous,
8.7 A Max.
• Pump 2: Circulation Pump
•Total Hydrojets: 17
• Therapy Jets: 5 Rotating Pro-Touch II
•Vertical Jets: 2 Pulsator
TM
TM
• Therapy Seat Jets: 8 Directional Pro-Touch II, 2 Mini-Mag Jets
35
• Air Controls / Massage Selectors: 2 / 1
TM
• Filter: 2-Stage MicroClean with Automatic Brominator
Cartridge, 20” SlipstreamTM Weir
TM
•Water Treatment: Brominator Chemical Feeder; Ready for PermaClear
TM
or SunZoneTM CD Installation
• Lighting: Underwater, with Two Colored Lenses; Optional SunGlowTM Multi-Color LED Light Kit
• Handrails: Integral
• Pillows: 2-Part/2-Tone Gray, Bolt-on; Optional Blue or Camel
Insert
• Heater:
- US/Canada Convertible Model (60 Hz): Low Flow, 1 kW @ 120 VAC or 4 kW @ 240 VAC
- Export Models (50/60 Hz): Low Flow , 2.7 kW
• Electrical Requirements:
- US/Canada Convertible Model (60 Hz): 120 VAC @ 15 A or 240 VAC @ 25 A or 40 A
- Export Models (50/60 Hz): 230 - 240 VAC @ 20 A or 30 A; or suitably rated circuit breaker to comply with local electrical regulations. Certain countries may require dual power in­puts; two 16 A breakers are required for this configuration.
36

17.3 Caprio Specifications

• Dimensions:
-With Wood Cabinet: 79” x 88” x 33” (201 cm x 224 cm x 84 cm)
- With Synthetic Cabinet: 77” x 86” x 33” (196 cm x 218 cm x 84 cm)
• Seating Capacity: 3-4 Adults
• Dry Weight: 638 lbs / 289 kg
• Filled Weight: 3,543 lbs / 1,607 kg
•Water Capacity (Avg. Fill):
350 US Gal / 1,325 Liters
• Controls: Solid-State Electronic Controls with LED Readout, Programmable Temperature, Filtration, and Heat Cycles
•Water Delivery: 1 TheraFlo
TM
High Flow Pump
• Pump 1 Rating by Model:
- US/Canada Convertible Model (60 Hz): 2-Speed/1.5 hp
Continuous, 13.6 A Max.
- Export Model (50 Hz/60 Hz): 2-Speed / 2.0 hp Continuous,
8.7 A Max.
• Pump 2: Circulating Pump
•Total Hydrojets: 23
• Therapy Jets: 3 Pro-Touch II
TM
, 1 Duo-Path
TM
•Vertical Jets: 3 Pro-Touch II
• Therapy Lounge Jets: 6 Mini-Intelli-Jet
• Accu-Ssage Therapy Seat Jets: 10 Accu-Pressure
TM
TM
37
• Air Controls/Massage Selectors: 3/1
TM
• Filter: 2-Stage MicroClean with Automatic Brominator
Cartridge, 20” SlipstreamTM Weir
TM
•Water Treatment: Brominator Chemical Feeder; Ready for
TM
PermaClear
or SunZoneTM CD Installation
• Lighting: Underwater, with Two Colored Lenses; Optional
TM
SunGlow
Multi-Color LED Light Kit
• Handrail: 1 High Quality Stainless Steel, 1 Integral
• Pillows: 2-Part/2-Tone Gray, Bolt-on; Optional Blue or Camel
Insert
• Heater:
- US/Canada Convertible Model (60 Hz): Low Flow, 1 kW @ 120 VAC or 4 kW @ 240 VAC
- Export Model (50 Hz/60 Hz): Low Flow, 2.7 kW @ 230-240 VAC
• Electrical Requirements:
- US/Canada Convertible Model (60 Hz): 120 VAC @ 15 A or 240 VAC @ 25 A or 40 A
- Export Model (50 Hz / 60 Hz): 230 - 240 VAC @ 20 A or 30 A; or suitably rated circuit breaker to comply with local electrical regulations. Certain countries may require dual power in­puts; two 16 A breakers are required for this configuration.
38
D.A.L./11.20.03
Notes:
Sundance Spas, Inc.
14525 Monte Vista Ave, Chino, CA 91710/U.S.A.,
Phone: (909) 606-7733, Fax: (909) 606-0195
Website: http://www.sundancespas.com
6530-386, Rev. A © 2003 Sundance Spas, Inc. Printed in U.S.A.