Sunchaser Duo-Therm Rotary XL 55812.041, Duo-Therm Classic 54812.041, Duo-Therm Classic 54815.041, Duo-Therm Classic 54812.042, Duo-Therm Rotary XL 55812.042 Installation And Operating Instructions Manual

...
INSTALLATION
and OPERATING
INSTRUCTIONS
ROOF MOUNT
AIR CONDITIONER
Rotary XL (558 Series)
and Classic (548
QUICK START
SHUR START
MODELS
MODELS
54812.041
54812.042
55812.041
55812.042
54815.041
54815.042
54815.043
54815.044
55815.041
55815.042
READ THESE INSTRUCTIONS CAREFULLY, KEEP FOR FUTURE REFERENCE.
AVIS:
Cet appareil
doit
etre
repare
seulement par
un reparateur
autorise.
Modification de
I’appareil pourrait
etre
extremement
dangereuse.
CAUTION
MODIFICATION OF THIS APPLIANCE
CAN
BE
EXTREMELY
HAZARDOUS.
ALWAYS CONSULT
THE MANUFACTURER BEFORE MAKING CHANGES.
et pourrait
Causer
mal ou mort.
Form No. 19-1112-2 7-14-80
SPECIFICATIONS
* For
two units
USE
5000 watt generator
DUO-THERM TESTED UNDER ARI STANDARD 250-74
UL STANDARD 484
.
CSA STANDARD 22.2 No.
0,46
and 119
14” x 14” OPENING FROM ROOF VENT REMOVAL
Right
1.
Normally, roof mount air conditioners are installed where an existing roof vent has been removed. This creates the
14” x 14” opening required for installation (Fig. 1). If an opening has to be cut, be sure to check for proper clearance on the inside of the RV for the air box (Fig. 2) and on the outside for the unit. (Fig. 3).
AIR
CONDITIONER DIMENSIONS
7
ROOF FLASHING DIMENSIONS
(On
Top of Vehicle)
7 I
FIG. 2
Left
RIGHT
Air Box Perimeter
I
LEFT
MINIMUM DISTANCE TO ANY
VERTICAL SURFACE (Example:
Luggage Rack) FOR CONDENSER
AIR FLOW
14” x 14” OPENING
FIG. 3
-2-
INSTALLATION LAYOUT
Fig. 4
AIR CONDITIONING UNIT
NOTE:The anchor bolts, supplied as standard equipment, will cover a range of 2
3/8"
to 4
1/8" roof thickness. For roof thicknesses, other than the standard, special Bolt Kits can be obtained by
special order. For roof sections thinner than the standard, bolts can be cut off, care must be taken so that threads are not damaged. Bolt Kits are available as follows:
Threaded Hole
ROOF
KIT PART NO.
THICKNESS RANGE
3-14870(std)
2-3/8"
to 4-
1/8"
3-14867(opt)
1 to 2-3/8”
314868(opt)
3-3/4" to 5-1 /4"
314869(opt)
5-
1/4" to 6- 1/8"
(B)
Machine Screw
1
(Cl
Hex Nut
2
(D)
Nut & Lockwasher 4
Total No.
x
v B
@
e
63
(E)
Self Taping Screw 4
(Blunt Point)
(F)
Wire Connector
2
(G)
Anchor Bolt (Straight)
1
(H)
Anchor Bolt (Hook) 3
OPTIONAL HEAT PACKAGE AVAILABLE FROM DEALER
PART NUMBER 3-15603 SOLD IN U.S.A. ONLY (UL Listed)
AIR BOX ASSEMBLY 3-13577 FOR CANADA
(CSA
Certified)
MOUNTING PARTS
Roof
Flashing
Adhesive .
Return Air
J
Conduit Attached to Unit
\
Control
BOX
./
Guide Flanges
7
Power Supply Line
\
Framing Stock
Loading...
+ 5 hidden pages