Sun Castle Global Precision Technology Co SCGPTDL0003 Users manual

SKR600 Specification
Dimension -- Panels
290(H) x 70(W) x 72 (D)-(mm)
Product Overview
Up Button Use it to add new keycards/ PIN codes
Down Button Use it to delete keycards/ PIN codes
Battery Cover
Use the special tool provided to open
SKR600
Electronic RFID & Keypad Door Lock
Operation Manual
The picture is for reference only. Please check the actual model for specific functions.
Interior plate (Inside view)
--Accessories--
Exterior plate
(Outside view)
Sensor
Keypad
PIN codes consist of 4~8 digits, numbers can be repeated
Confirm/Exit Button
Select Button
Keyhole Cover
Horizontally position the key and turn the keyhole cover 90 clockwise to remove it then unlock with the key
Before After
Approximate Weight4520 g
Door Thickness 45mm ~ 55mm 56mm ~ 80mm
Standard US Mortise Lockbody
Use 4AA Alkaline batteries (1.5V)
Others RFID Sensor Digital Pad (Metal & Waterproof)
Temperature-10 C ~ 70 C
Unlocking Methods
1.Mechanical Key : Horizontally position the key and turn the keyhole cover 90 degrees
clockwise to remove it then unlock with the key.
2.Keycard : Press any button to enter the system, simply place the RFID card to the sensor.
3.PIN Code : Press any button to enter the system, enter assigned PIN code and press
to confirm.
4.Passage Mode : Place the RFID card to the sensor or enter assigned PIN code and press
. Press to lock.
*#*
Door Lock Status
Status
Operation Successful
Operation Failed
Enter/ Exit Setup Mode
Low Battery
Door Opened Indication
Door Closed Indication
Types of No.
Type
Administrator
User
Single-Entry User
Volume
1 beep after the right Keycard or PIN code that the lock is open.
After depressing the lever, the door is locked 1.5 seconds after the lever comes back to the horizontal position.
Quantity Function No. Instruction
4 sets
94 sets
1 set
1 set
Light
Blue
Red
Blue / Red
Red
Add/Modify/Delete
Unlock the door
Can be used only
once
Sound volume
* *
Sounds
1 beep
3 beeps
2 beeps
5 continuous beeps
00~03
Unlocking Keycards or PIN codes.
04~97
Keycards or PIN codes be used
98
only once.
99
Emergency Override Key
3 keys provided per lock
RFID Keycards
Notice
The factory default admin. PIN code is 123456. It is highly recommended to change the
admin. code upon installation of the lock.
Only one PIN code or one Keycard can be set per No. of location.
Please turn to the last page to restore to the factory default settings.
There is no need to reset PIN codes or Keycards after battery replacement.
The setup mode cannot be entered during the passage mode.
PIN Code/ RFID Keycard Setup
Administrator Setup
Enter the Setup Mode
Press the Up Button on the back of the lock for 2 seconds until hear two beeps.
1
User Setup
Administrator Recognition
- First time setup
Input the factory default admin. PIN code (123456) and then press to confirm.
- Admin. already setup
Input admin. PIN code and then press to confirm or position the admin. card to the sensor.
2
2
Press the No. 00~ 99
Press the No.
00/ 01
02/ 03
3
Enter the Intended PIN Code or Card
Enter the intended admin. PIN code (consists of 4-8 digits), and then press to confirm or position the admin. card to the sensor.
4
Exit Setup Mode
5
Press the Up Button on the back of the lock for 2 seconds until hear two beeps.
1
Single-Entry User Setup
Press the Up Button on the back of the lock for 2 seconds until hear two beeps.
1
Notice
1. The admin. and user PIN code cannot be 000000/111111/123456. Blue light flashes if the setup location has been occupied.
2.
Other Setup
User Deletion
Enter the Setup Mode
Press the Down Button on the back of the lock for 2 seconds until hear two
1 2 3 4
beeps.
Volume Setup
Enter the Setup Mode
Press the Up Button on the back of the lock for 2 seconds until hear two
1 2 3 4 5
beeps.
All User Deletion
Press the Down Button on the back of the lock for 2 seconds until hear two
1 2 3 4
beeps.
Administrator
Recognition
Input admin. PIN code and then
press to confirm or position the admin. card to the sensor.
Administrator Recognition
Input admin. PIN code and then press to confirm or position the admin. card to the sensor.
Input admin. PIN code and then
press to confirm or position the admin. card to the sensor.
Input admin. PIN code and then press to confirm or position the admin. card to the sensor.
Input admin. PIN code and then press to confirm or position the admin. card to the sensor.
Press the No.
Press
the No. 99
2
2
Enter
Enter the No. you intend to delete ( 01 ~ 97),
and then press to confirm or position the card.
Press the Down Button on the back of the lock for 5 seconds until hear a continuous beep and two short beeps mean successful reset.
Enter
Press 00(mute), 01(low), 02(medium) or 03(loud), and then press to confirm.
Exit Setup Mode
Press the No.
04 ~ 97
3
Press the No. 98
3
3.
3 beeps (red light) mean operation failure.
4.
If no actions are taken over 5 seconds during the setup mode, the system will exit automatically with two beeps (blue light).
Factory Default Setting
1. Remove one battery.
2. Next, while continuously pressing the two buttons on the back, reinstall the battery.
A continuous beeps (red light) and a short beep (blue light) after successful operation.
Troubleshooting
Continuous beeps after successful
Exit Setup Mode
No reaction when entering Keycards/
Important Notes
If the Keycard is lost, please delete it right away.
1.
* NoticeThe administrator (*00) can’t be deleted individually.
2.
Please use alkaline batteries only. Do not mix using old and new batteries.
The battery leakage will cause damage of the product. Please make
3.
regular inspections of battery leakage.
4.
Use a clean and dry cloth to preserve the cleanliness of the product. Do not use alcohol or othe rchemical agents.
5.
If you encounter any problems, please refer to the user manual first. If you
still
have questions, please feel free to contact us or email us.
Enter the intended PIN code (consistsof 4-8 digits), and then press to confirm or position the card
4
to the sensor.
Enter the intended PIN code (consistsof 4-8 digits), and then press to confirm or position the card to the sensor.
Problem
operation
PIN codes
Light doesn’t go off
4
Indication
Low battery alert. Please replace batteries immediately.
Batteries are dead. Please use the key to unlock.
Consecutive Keycards/PIN codes entry
errors. Pleae try again after 1 minute.
Replace batteries.
5
5
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: . Reorient or relocate the receiving antenna. . Increase the separation between the equipment and receiver. . Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. . Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices).
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Loading...