TROUBLESHOOTING
FREQUENTLY ASKED QUESTIONS
STORAGE INSTRUCTIONS
REPLACEMENT ACCESSORIES
WARRANTY INFORMATION
TRUSTED FOR OVER
100 YEARS
SWM5750DN
TROUBLESHOOTING
TROUBLE PROBABLE CAUSE SOLUTION
• Unitdoesnotturn
on.
• Mistoutputminimal
to none.
• WaterLeaksfrom
tank.
• CrackinTank.
• Filmontank. * Mineral deposits.
Question Answer
• What are the variables that affect
run time?
• How do I remove film on water tank?
• How can I extend the run time?
* Not plugged in.
* Outlet not functioning.
* The unit needs to be reset.
* Scale buildup on heating element.
* Humidifier is not warmed up yet.
* Tank rubber ring is missing.
* Cap not tight enough.
* Tank water is Hot.
* Hot water will cause tank to
pressurize.
* Tanks will crack if hit or dropped.
FREQUENTLY ASKED QUESTIONS
The estimated run time for this humidifier is based on average room
conditions. The actual run time of your humidifier is dependent on numerous
variables such as:
4
Air exchange in the room where the humidifier is placed.
4
Room construction of the room where the humidifier is placed.
4
Temperature of the room where the humidifier is placed.
4
Humidity levels in the room where the humidifier is placed.
4
Movement of occupants and the opening and closing of doors in the room
where the humidifier is placed.
4
Home furnishings in the room where the humidifier is placed.
4
See Daily Maintenance instructions. Regular cleaning is recommended.
4
Run your unit on the lowest setting.
4
Fill the tank all the way full, place it on the base, let the water empty into
the base until it stops bubbling, then refill the tank full again. This ensures
maximum water capacity and will extend run time.
4 Plug in unit.
4 Have outlet replaced by a licensed electrician.
4 Follow manual for Reset Instructions..
4 Remove scale from heating element
4 Allow 1 minute for the humidifier to warm up.
4
Remove tank cap and replace or reposition ring.
4 Tighten the cap.
4 Fill with cool water only.
4 Fill with cool water only.
4 Handle tank with Care.
4 Clean/disinfect tank as instructed in weekly
cleaning instructions
STORAGE INSTRUCTIONS
When not using your humidifier for an extended period of time:
1.
Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in the
unit when storing. Leaving water in the unit may render the unit inoperable for the following season.
2. Place the humidifier in the original carton and store in a cool, dry place.
3 Wait for the heating element to cool completely, and then clean the heating element with a damp soft cloth.
.
4 Remove the tank cap. Do not store with the tank cap in place.
REPLACEMENT ACCESSORIES
To order the replacement accessories you can do any of the following:
• Visityourlocalretailer
• Goto
• Callconsumerserviceat1-888-264-9669
www.sunbeam.com
If you have any questions regarding your product or would like to learn more about other Sunbeam® products, please
contact our Consumer Service Department at 1-888-264-9669 or visit our website at www.sunbeam.com.
Sunbeam Products, Inc. doing business as Jarden Consumer Solutions or if in Canada, Sunbeam Corporation (Canada)
Limited doing business as Jarden Consumer Solutions (collectively “JCS”) warrants that for a period of one year from
the date of purchase, this product will be free from defects in material and workmanship. JCS, at its option, will repair
or replace this product or any component of the product found to be defective during the warranty period.
Replacement will be made with a new or remanufactured product or component. If the product is no longer available,
replacement may be made with a similar product of equal or greater value. This is your exclusive warranty. Do NOT
attempt to repair or adjust any electrical or mechanical functions on this product. Doing so will void this warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable.
Keep the original sales receipt. Proof of purchase is required to obtain warranty performance. JCS dealers, service
centers, or retail stores selling JCS products do not have the right to alter, modify or any way change the terms and
conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or
misuse of the product, use on improper voltage or current, use contrary to the operating instructions, disassembly,
repair or alteration by anyone other than JCS or an authorized JCS service center. Further, the warranty does not
cover: Acts of God, such as fire, flood, hurricanes and tornadoes.
What are the limits on JCS’s Liability?
JCS shall not be liable for any incidental or consequential damages caused by the breach of any express, implied or
statutory warranty or condition.
Except to the extent prohibited by applicable law, any implied warranty or condition of merchantability or fitness for a
particular purpose is limited in duration to the duration of the above warranty.
JCS disclaims all other warranties, conditions or representations, express, implied, statutory or otherwise.
JCS shall not be liable for any damages of any kind resulting from the purchase, use or misuse of, or inability to use
the product including incidental, special, consequential or similar damages or loss of profits, or for any breach of
contract, fundamental or otherwise, or for any claim brought against purchaser by any other party.
Some provinces, states or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages
or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from province to province,
state to state or jurisdiction to jurisdiction.
1 YEAR LIMITED WARRANTY
Filter Free Warm Mist
Humidi
fi
er
How to Obtain Warranty Service
In the U.S.A.
If you have any question regarding this warranty or would like to obtain warranty service, please call
1-888-264-9669 and a convenient service center address will be provided to you.
In Canada
If you have any question regarding this warranty or would like to obtain warranty service, please call
1-888-264-9669 and a convenient service center address will be provided to you.
In the U.S.A., this warranty is offered by Sunbeam Products, Inc. doing business as Jarden Consumer Solutions located
© 2012 Sunbeam Products, Inc. doing business as Jarden Consumer Solutions. All Rights Reserved.
Distributed by Sunbeam Products, Inc. doing business as Jarden Consumer Solutions, Boca Raton, Florida 33431.
Printed In China
in Boca Raton, Florida 33431. In Canada, this warranty is offered by Sunbeam Corporation (Canada) Limited doing
business as Jarden Consumer Solutions, located at 20 B Hereford Street, Brampton, Ontario L6Y 0M1. If you have any
other problem or claim in connection with this product, please write our Consumer Service Department. PLEASE DO
NOT RETURN THIS PRODUCT TO ANY OF THESE ADDRESSES OR TO THE PLACE OF PURCHASE.
Instruction Leaflet
PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS
DIAGNÓSTICO DE PROBLEMAS
PREGUNTAS FRECUENTES
PROBLEMA
• La unidad no se
enciende.
•
Salida de vapor
mínima o nula.
•
El agua está
goteando del
tanque
.
•
El tanque está
agrietado
•
Hay residuos en
el tanque.
PREGUNTAS RESPUESTAS
•
Cuáles son las variables que
afectan el tiempo de
funcionamiento?
•
Cómo quito la película del
tanque de agua?
• Cómo puedo extender el
tiempo de funcionamiento?
* No está enchufada.
* El omacorriente no funciona.
* Se debe reiniciar la unidad.
* Acumulación de sarro en el calentador.
*
El humidificador no se ha calentado
*
El aro de goma no está colocado en el
*
La tapa no está suficientemente apretada.
*
El agua del tanque está caliente.
*
*
.
*
DIAGNÓSTICO DE PROBLEMAS
POSIBLE CAUSA SOLUCIÓN
4 Enchúfela.
4
Haga reemplazar el tomacorriente por
un electricista matriculado.
4 Siga manual para Repuso Instrucciones.
4
Retire el sarro del calentador
4
Espere 1 minuto para que el
todavía.
tanque
.
El agua caliente causará presión en el tanque.
El tanque se agrietará si es golpeado o
está goteando.
Hay depósitos minerales.
PREGUNTAS FRECUENTES
El tiempo de funcionamiento estimado de este humidificador está basado en las
condiciones ambientales promedio. El tiempo de funcionamiento actual de su
humidificador depende de varios factores tales como:
4
El intercambio de aire en el cuarto donde se encuentra el humidificador.
4
La estructura del cuarto donde se encuentra el humidificador.
4
La temperatura del cuarto donde se encuentra el humidificador.
4
Los niveles de humedad en el cuarto donde se encuentra el humidificador.
4
La actividad de los ocupantes y la secuencia en que se abren y cierran las puertas del
cuarto donde se encuentra el humidificador.
4
El número de muebles presentes en el cuarto donde se encuentra el humidificador.
4
Consulte las instrucciones diarias de mantenimiento. Se recomienda una limpieza
regular.
4
Haga funcionar la unidad en el modo más bajo.
4
Llene el tanque al máximo, colóquelo en la base, deje que el agua se vacíe en la base
hasta que deje de burbujear, luego llene nuevamente el tanque al máximo. Esto
asegura una capacidad máxima de agua que extenderá el tiempo de funcionamiento.
humidificador se caliente.
4
Remueva la tapa del tanque y coloque el
aro de goma correctamente.
4 Cierre la tapa.
4 Llene con agua fría solamente.
4
Llene con agua fría solamente.
4
Maneje el tanque con cuidado.
4
Clean/disinfect tank as instructed in
weekly cleaning instructions.
INSTRUCCIONES PARA GUARDAR
INFORMACION DE LA GARANTIA
ACCESORIOS DE REPUESTO
INSTRUCCIONES PARA GUARDAR
Cuando no esté utilizando su humidificador por un tiempo prolongado:
1. Limpie, enjuague y seque el humidificador como se indica en las instrucciones de mantenimiento semanal. NO deje
ningún residuo de agua dentro de la unidad mientras esté guardado. El dejar agua dentro de la unidad podría
causar daños en su funcionamiento para cuando desee volverlo a utilizar.
2. Coloque el humidificador en su empaque original y guárdelo en un lugar fresco y seco.
3. Espere hasta que el calentador se enfríe completamente, y luego límpielo con un paño suave y húmedo.
.
4. Retire la tapa del tanque. No guarde el tanque con la tapa puesta.
ACCESORIOS DE REPUESTO
Puede ordenar accesorios de repuesto de una de las siguientes formas:
• Visitesudistribuidorlocal
• Vallaa
• Llameaservicioalconsumidoral1-888-264-9669
Si tiene preguntas relacionadas con este producto o si está interesado en conocer otros productos Sunbeam®,
póngase en contacto con nuestro Departamento de Servicio al Cliente: llame al 1-888-264-9669 o visite nuestro
sitio web www.sunbeam.com.
www.sunbeam.com
Sunbeam Products, Inc. operando bajo el nombre de Jarden Consumer Solutions, o en Canadá, Sunbeam Corporation
(Canada) Limited operando bajo el nombre de Jarden Consumer Solutions, (en forma conjunta, “JCS”), garantiza que
por un período de uno años a partir de la fecha de compra, este producto estará libre de defectos de materiales y
mano de obra. JCS, a su elección, reparará o reemplazará este producto o cualquier componente del mismo que
presente defectos durante el período de garantía. El reemplazo se realizará por un producto o componente nuevo o
reparado. Si el producto ya no estuviera disponible, se lo reemplazará por un producto similar de valor igual o
superior. Ésta es su garantía exclusiva. No intente reparar o ajustar ninguna función eléctrica o mecánica de este
producto. Al hacerlo elimínará ésta garantía.
La garantía es válida para el comprador minorista original a partir de la fecha de compra inicial y la misma no es
transferible. Conserve el recibo de compra original. Para solicitar servicio en garantía se requiere presentar un recibo de
compra. Los agentes y centros de servicio de JCS o las tiendas minoristas que venden productos de JCS no tienen
derecho a alterar, modificar ni cambiar de ningún otro modo los términos y las condiciones de esta garantía.
Esta garantía no cubre el desgaste normal de las piezas ni los daños que se produzcan como resultado de uso negligente
o mal uso del producto, uso de voltaje incorrecto o corriente inapropiada, uso contrario a las instrucciones operativas, y
desarme, reparación o alteración por parte de un tercero ajeno a JCS o a un Centro de Servicio autorizado por JCS.
Asimismo, la garantía no cubre actos fortuitos tales como incendios, inundaciones, huracanes y tornados.
¿Cuál es el límite de responsabilidad de JCS?
JCS no será responsable de daños incidentales o emergentes causados por el incumplimiento de alguna garantía o
condición expresa, implícita o legal.
Excepto en la medida en que lo prohíba la ley aplicable, cualquier garantía o condición implícita de comerciabilidad o
aptitud para un fin determinado se limita, en cuanto a su duración, al plazo de la garantía antes mencionada.
JCS queda exenta de toda otra garantías, condiciones o manifestaciones, expresa, implícita, legal o de cualquier otra
naturaleza.
JCS no será responsable de ningún tipo de daño que resulte de la compra, uso o mal uso del producto, o por la
imposibilidad de usar el producto, incluidos los daños incidentales, especiales, emergentes o similares, o la pérdida de
ganancias, ni de ningún incumplimiento contractual, sea de una obligación esencial o de otra naturaleza, ni de ningún
reclamo iniciado contra el comprador por un tercero.
Algunas provincias, estados o jurisdicciones no permiten la exclusión o limitación de los daños incidentales o
emergentes ni las limitaciones a la duración de las garantías implícitas, de modo que es posible que la exclusión o las
limitaciones antes mencionadas no se apliquen en su caso.
Esta garantía le otorga derechos legales específicos y es posible que usted tenga otros derechos que varían de un
estado, provincia o jurisdicción a otro.
GARANTÍA LIMITADA DE 1 AÑO
CONFIANZA
DESDE HACE
100 AÑOS
SWM5750DN
Niebla Cálida de Filtro Libre
Humidicador
Cómo solicitar el servicio en garantía
En los Estados Unidos
Si tiene alguna pregunta sobre esta garantía o desea recibir servicio de garantía, llame al 1-888-264-9669 y podrá
obtener la dirección del centro de servicio que le resulte más conveniente.
En Canadá
Si tiene alguna pregunta sobre esta garantía o desea recibir servicio de garantía, llame al 1-888-264-9669 y podrá
obtener la dirección del centro de servicio que le resulte más conveniente.
© 2012 Sunbeam Products, Inc. operando bajo el nombre de Jarden Consumer Solutions. Todos los derechos reservados.
Distribuido por Sunbeam Products, Inc. operando bajo el nombre de Jarden Consumer Solutions, Boca Raton, Florida 33431.
157950 Rev. B SWM5750DN_12ESM2 Impreso en China
GCDS-SUN25194-ZZ
En los Estados Unidos, esta garantía es ofrecida por Sunbeam Products, Inc. operando bajo el nombre de Jarden
Consumer Solutions, Boca Ratón, Florida 33431. En Canadá, esta garantía es ofrecida por Sunbeam Corporation
(Canada) Limited operando bajo el nombre de Jarden Consumer Solutions, 20 B Hereford Street, Brampton, Ontario
L6Y 0M1. Si usted tiene otro problema o reclamo en conexión con este producto, por favor escriba al Departamento
de Servicio al Consumidor. POR FAVOR NO DEVUELVA ESTE PRODUCTO A NINGUNA DE ESTAS
DIRECCIONES NI AL LUGAR DE COMPRA.
Folleto de instrucciones
LEA Y CONSERVE ESTAS IMPORTANTES INSTRUCCIONES
SWM5750DN_12ESM2.indd 1 6/29/12 11:00 PM
PLEASE READ AND SAVE THESE
IMPORTANT SAFETY INSTRUCTIONS
FEATURES - OPERATIONS
FEATURES - OPERATIONS
CLEANING / MAINTENANCE
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire, electric
shock, and injury to persons, including the following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance
directlyintoa120VACelectricaloutlet.
3. Keep the cord out of heavy traffic areas. To avoid
firehazard,NEVERputthecordunderrugsornear
heat registers.
4. DO NOT place humidifier near heat sources such as
stoves, radiators, and heaters. DO locate your
humidifier on an inside wall near an electrical outlet.
The humidifier should be at least 4 inches away from
the wall for best results.
5. NEVERplacehumidifierinanareawhereitis
accessibletochildren.NEVERusehumidifierina
closed room, particularly where a child may be
sleeping, resting, or playing (a closed room may
result in excessive humidity).
6. WARNING: Do not attempt to refill humidifier
without first unplugging the unit from its electrical
outlet. Failure to heed this warning may cause
personal injury. Be sure to unplug the unit by pulling
on the plug and not the cord.
7. Never place anything over moisture outlet when the
unit is running.
8. NEVERdroporinsertanyobjectintoanyopenings.
DO NOT place hands, face or body directly over or
near Moisture Outlet while unit is in operation. DO
NOT cover Moisture Outlet while the unit is operating.
9. DO NOT operate any appliance with a damaged cord
or plug, after the appliance malfunctions, or if it has
been dropped or damaged in any manner. Return
appliance to manufacturer for examination, electrical
or mechanical adjustment, or repair.
10. Use appliance only for intended household use as
described in this manual. Any other use not
THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the
other). To reduce the risk of electric shock, this plug is intended to fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to
install the proper outlet.
DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS
SAFETY FEATURE IN ANY WAY.
recommended by the manufacturer may cause fire,
electric shock, or injury to persons. The use of
attachments not recommended or sold the
manufacturer may cause hazards.
11. DO NOT use outdoors.
12. Always place humidifier on a firm, flat, level surface.
A waterproof mat or pad is recommended for use
underthehumidifier.NEVERplaceitonarugor
carpet, or on a finished floor that may be damaged
by exposure to water or moisture.
13. DO NOT allow the Moisture Outlet to directly face the
wall. Moisture could cause damage, particularly to
wallpaper.
14. Humidifier should be unplugged when not in use.
15.NEVERtilt,move,orattempttoemptyunitwhileitis
operating. Shut off and unplug before removing the
water tank and moving the unit. If you have a warm
mist humidifier, DO NOT attempt to remove the
water tank within 15 minutes after the humidifier is
turned off and unplugged. Serious injury may result.
16. This humidifier requires daily and weekly
maintenance to operate appropriately. Refer to daily
and weekly cleaning procedures. Use only cleaners
and additives recommended by the manufacturer.
Never use gasoline, glass cleaner, furniture polish,
paint thinner, or other household solvents to clean
any part of the humidifier.
17. Excessive humidity in a room can cause water
condensation on windows and some furniture. If this
happens, turn the humidifier OFF.
18. Do not use humidifier in an area where humidity
level is in excess of 50%. Use a hygrometer,
available at your local retailer or through the
manufacturer, to measure the humidity.
19. DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void
your warranty. The inside of the unit contains no
user serviceable parts. All servicing should be
performed by qualified personnel only.
20. Never place housing under water flow, or immerse in
liquids.
21. DO NOT plug in the cord with wet hands, electric
shock could result.
22. DO NOT pour water in any openings other than the
water tank.
23. If you have a warm mist humidifier, allow unit to cool
before refilling water tank or maintenance as the
heater bulb is hot.
24. To prevent damage to surfaces, do not place
humidifier under overhanging surfaces.
25.NEVERoperateunitwithoutwaterinthetank.
26. Do not move unit after it has been used until unit
cools completely.
27. Use both hands when carrying full tank of water.
CAUTION: Mist can be HOT. Keep away
from children.
PLEASE READ AND SAVE
THESE IMPORTANT
SAFETY INSTRUCTIONS
CONSUMER SAFETY INFORMATION
NOTE: This is an electrical appliance and requires attention
when in use.
NOTE: If moisture forms on the walls or windows of the
room, turn off the humidifier. The room already has plenty
of humidity and additional moisture may cause damage.
NOTE: DO NOT block air inlet or outlet.
Cord and Plug Installation Safety Instructions:
The length of cord used on this appliance was selected to
reduce the hazards of becoming tangled in, or tripping
over a longer cord. If a longer cord is necessary an
approved extension cord may be used. The electrical
rating of the extension cord must be equal to or greater
than the rating of the humidifier (refer to the rating
information placed on the humidifier). Care must be
taken to arrange the extension cord so that it will not
drape over the countertop or tabletop where it can be
pulled on by children or accidentally tripped over.
HOW WARM MIST WORKS
Your Sunbeam® Warm Mist humidifier is designed to
allow the proper amount of water to flow out of the tank.
Air is drawn in through the grill openings located in the
back of the unit and mixed with steam in the misting
chamber. The warm mist is then dispersed out of the top
of the misting chamber through the outlet grill and into
the room.
NOTE: A humidity level below 20% can be unhealthy
and uncomfortable. The recommended humidity level is
between 40%-50%.
PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is switched off.
2. Select a location for your humidifier, on a flat level
surface about 4 inches (10cm) away from the wall.
DO NOT place the humidifier on a finished floor or
near furniture, which can be damaged by too much
moisture or water. Place on a moisture resistant surface.
3. Remove the tank from the main housing.
4. Bring the tank to the sink, turn upside down and
twist off the tank cap by turning counter clockwise.
Fill tank with cool, fresh tap water. DO NOT fill with
warm water as this may cause leaking. Replace the
cap on tank FIRMLY. The tank will hold 1 gallon of water.
5. Make sure the safety lock is rotated completely to the
locked position. Place tank back on to the housing.
The tank will immediately begin to empty into the base.
6. Plugthehumidifierintoa120Velectricaloutlet.
MEDICINE TRAY
There is a medicine tray located on top of the mist chamber
grill. To use, pour designated humidifier medication into the
tray and then turn on your humidifier as directed.
NOTES:
• DONOTaddmedicationtothewatertank.
• DONOTaddmedicationtothemedicinetraywhenthe
unit is already operating.
OPERATING INSTRUCTIONS
IMPORTANT:
1. Press the Power Button (
NOTE: This humidifier is featured with rapid steam.
After powered on, the humidifier will begin to mist
within 1 minute. A boiling noise is normal. To
minimize the noise level, operate the unit at low setting.
* Visible mist under 1 minute was measured using
water at an average temperature of 65°F (18°C).
2. After the unit begins misting, the humidifier will run
at Hi setting (Hi indicator light will illuminate). Press
the Mist Button( ) to switch to the Lo setting and
the Lo indicator light will illuminate.
3. To switch the humidifier off, press the Power Button
until all indicator lights go off.
WARNING: DO NOT move the humidifier with water in
the tank or the humidifier base. The moving action of the
water may activate the water tank’s release nozzle and
overfill the humidifier base. This may cause the
humidifier to function intermittently, or stop emitting
mist. Should this occurs, simply remove the excess water
from the humidifier base.
Figure 1
A. Humidifier Tank
B. Humidifier Housing
C. Humidifier Base
D. Power Button( )
G
F
E
D
) to switch on the unit.
A
B
C
E. Mist Button( )
F. Hi/Lo Indicator Lights
G. Misting Chamber with
Medicine Tray
RESET PROCEDURE
When the water in the tank is empty and the water in the
heating chamber is almost empty, the Automatic Shut Off
will activate to prevent overheating. The humidifier will
stop operation until the water tank is refilled and
humidifier is reset as below:
1. Switch OFF the humidifier and unplug.
2. Remove and refill the water tank, follow the "Daily
Maintenance" and Pre-Operating Instructions to clean
and refill the water tank. Replace the tank onto the unit.
3. Allow 15 minutes for the Automatic Shut off to reset.
4. After 15 minutes, plug in the unit and switch ON the
humidifier to begin operation. Within 1 minute, the
unit will begin to produce moisture. If the unit does
not start working, it is still too hot. Unplug the unit,
wait 15-30 additional minutes, plug the unit back in.
The unit should now be cool enough and operate
normally.
Control Panel
F
E
D
CLEANING AND MAINTENANCE
INSTRUCTIONS
The following maintenance procedures must be
routinely followed in order to ensure proper,
efficient operation of your humidifier. The unit
WILL NOT WORK CORRECTLY if it is not cleaned
properly.
When the unit is in use, daily and weekly maintenance is
recommended. Regular weekly cleaning prevents scale
buildup on the heating element and tray. It also prevents
micro-organisms from growing on the tray and tank. This
ensures that maximum efficiency will be achieved.
We cannot over-emphasize how essential proper
cleaning is to the maintenance and continued use
of your unit and to the avoidance of algae or
bacteria build-up.
DAILY MAINTENANCE
Allow to cool before maintenance.
1. Before cleaning, switch OFF the humidifier and
unplug the unit from the electrical outlet.
2. Remove the water tank then unlock the humidifier
housing by rotating the safety lock towards the front
of the unit. Lift housing up from the humidifier base
(see Figure 2).
Figure 2
Safety Lock
Base
Safety Lock on Base
UNLOCK
Housing
3. Empty water and minerals from the base and place in
the top rack of the dishwasher. This will remove any
sediment and dirt that has accumulated in the base.
NOTE: It is imperative that the base is cleaned properly.
The base is dishwasher safe (top rack ONLY) for easy cleaning.
4. Wipe the heating element clean with a soft cloth after
it has had a chance to cool.
5. Replace housing and engage safety lock. The
Electronic Thermal Control Heating element is lined
with a coating that is designed to provide the easiest
cleaning and prolong the operating efficiency of the
humidifier. DO NOT use any metal or hard objects to
clean the Heating Element. Never use detergents,
gasoline, kerosene, glass cleaner, furniture polish,
paint thinner or other household solvents to clean
any part of the humidifier.
WEEKLY MAINTENANCE
Remove Scale: Allow to cool before maintenance.
1. Repeat steps 1-5 in the Daily Maintenance section.
2. Clean tray, heating element and heating element
shroud by filling tray with water solution containing
8-oz of undiluted white vinegar. Allow tray, heating
element and heating element shroud to sit in water
solution for 20 minutes. Clean tray, heating element
and heating element shroud with a soft brush.
Dampen a cloth with undiluted white vinegar and
wipe out entire tray/base, heating element and
heating element shroud area to remove scale.
3. Rinse with clean warm water to remove scale and the
white vinegar solution before beginning to disinfect
the tank.
4. Wipe the heating element clean with a soft cloth after
it has had chance to cool.
Disinfect tank:
1. Fill tank with 1/2 teaspoon of chlorine bleach and
1/2 gallon (1.9L) of water.
2. Let the solution stand for 20 minutes, swishing every
few minutes. Wet all surfaces.
3. Empty the tank after 20 minutes, and rinse well with
water until the bleach smell is gone. Dry with a clean
cloth or paper towel.
4. Refill the water tank with cool water; replace the
water tank. Repeat ALL Operating Instructions.
LEA Y CONSERVE ESTAS IMPORTANTES
INSTRUCCIONES DE SEGURIDAD
Debe tomar precauciones básicas de seguridad siempre que
utilice artefactos eléctricos para reducir el riesgo de incendio,
descarga eléctrica y daños personales, incluyendo lo siguiente:
1. Lea completamente las instrucciones antes de utilizar
el artefacto.
2. Para evitar incendio o descarga eléctrica, enchufe el
artefactodirectamenteenuntomacorrientede120VCA.
3.
Mantenga el cable fuera de las zonas de mucho tráfico.
Para evitar incendios, NUNCA coloque el cable debajo
de alfombrillas o cerca de salidas de calefacción.
4.
NO coloque el humidificador cerca de fuentes de calor
como estufas, radiadores y calefactores. NO coloque el
humidificador contra una pared interna cerca de un
tomacorriente. El humidificador debe estar a por lo
menos 4" de la pared para obtener el mejor resultado.
5.
NUNCA coloque el humidificador en una zona accesible
para los niños. NUNCA use el humidificador en un
cuarto cerrado, especialmente donde pueda haber un
niño durmiendo, descansando, o jugando (un cuarto
cerrado puede resultar en excesiva humedad).
6. ADVERTENCIA: No intente llenar nuevamente el
humidificador sin antes desenchufarlo del tomacorriente.
El no tener en cuenta esta advertencia puede causar
daños personales. Asegúrese de desenchufar la
unidad tirando del enchufe y no del cable.
7.
Nunca coloque algo sobre la salida de humedad
cuando la unidad esté funcionando.
8.
NUNCA inserte ningún objeto en una de las ranuras.NO
coloque las manos, la cara o el cuerpo directamente
sobre o cerca de la Salida de Humedad mientras la
unidad está funcionando. NO cubra la Salida de
Humedad mientras la unidad está funcionando.
9. NO utilice ningún artefacto si el cable o el enchufe están
dañados, luego de una falla, o si se ha caído o ha sufrido
cualquier tipo de daño. Devuelva el artefacto al fabricante
para su inspección, ajuste eléctrico o mecánico, o reparación.
10
.
Utilice el artefacto únicamente para el propósito
hogareño indicado en este manual. Cualquier uso
distinto al recomendado por el fabricante puede causar
incendio, descarga eléctrica, o daños personales. El uso
ESTE PRODUCTO TIENE UN ENCHUFE POLARIZADO (una hoja es más
ancha que la otra). A fin de disminuir el riesgo de descarga eléctrica, este
enchufe está diseñado para insertarse en un tomacorriente polarizado en
un solo sentido. Si el enchufe no entra completamente en el tomacorriente,
inviértalo. Si aun así no entra, llame a un electricista calificado para
instalar un tomacorriente apropiado.
NO MODIFIQUE EL ENCHUFE NI ANULE ESTA FUNCION DE SEGURIDAD
de accesorios no recomendados o que no sean vendidos
por el fabricante puede ser peligroso.
11. NO utilizar en el exterior.
12. Siempre coloque el humidificador en una superficie firme,
plana y nivelada. Se recomienda el colocar una alfombrilla
o bandeja resistente al agua debajo del humidificador.
NUNCA lo coloque sobre un tapete o una alfombra, o en
un piso que pueda dañarse con el agua o la humedad.
13.
NO haga que la salida de humedad apunte
directamente a la pared. La humedad puede causar
daños, especialmente al empapelado.
14. Se debe desenchufar el humidificador cuando no se usa.
15.
NUNCA incline, mueva o intente vaciar la unidad
mientras esté funcionando. Apague y desenchufe la
unidad antes de quitar el tanque de agua y moverla.
Si tiene un humidificador de aire caliente, NO
intenteretirar el tanque de agua dentro de los 15
minutos después de haber apagado y desenchufado
el humidificador. Podría causar una lesión grave.
16. Este humidificador requiere mantenimiento diario y
semanal para funcionar correctamente. Refiérase a los
procedimientos de limpieza diarios y semanales. Use
únicamente limpiadores y aditivos recomendados por el
fabricante. NUNCA use detergentes, gasolina, limpiavidrios,
limpiador de muebles, diluyente de pintura u otro solvente
hogareño para limpiar ninguna parte del humidificador.
17.
La humedad excesiva en un cuarto puede causar
condensación de agua en las ventanas y en algunos
muebles. Si sucede esto, apague el humidificador.
18.
No use el humidificador en un área donde el nivel de
humedad es mayor al 50%. Use un Higrómetro,
disponible en su tienda local o a través del
fabricante, para medir la humedad
19. NO intente reparar o ajustar ninguna función eléctrica o
mecánica de esta unidad. El hacerlo invalidará la
garantía. La unidad no contiene partes reparables por el
usuario. Toda reparación debe ser realizada únicamente
por personal calificado.
20. Nunca coloque el gabinete debajo de la canilla o lo
sumerja en líquidos.
DE NINGUNA MANERA.
.
CARACTERISTICA - FUNCIONAMIENTO
21. No enchufe el cable con las manos húmedas. Puede
ocasionarle una descarga eléctrica.
22. No coloque agua en ninguna abertura que no sea el
tanque de agua.
23. Si tiene un humidificador de aire caliente, permita que la
unidad se enfríe antes de recargar el tanque del agua o
realizar el mantenimiento ya que la bombilla del
calentador está caliente.
24. Para prevenir el daño a las superficies, no coloque el
humidificador debajo de ninguna superficie que
sobresalga por encima del mismo.
25.
NUNCA haga funcionar la unidad sin agua en el tanque.
26.
Una vez utilizada la unidad, no la mueva hasta que
se haya enfriado completamente.
27. Use las dos manos cuando cargue el tanque de agua.
PRECAUCIÓN: EI vapor puede estar
CALIENTE. Mantenga alejado de los ni
ños.
LEA Y CONSERVE ESTAS
INSTRUCCIONES
IMPORTANTES DE SEGURIDAD
INFORMACION DE SEGURIDAD PARA EL
CONSUMIDOR
NOTA: Este es un artefacto eléctrico y requiere ser usado con
cuidado.
NOTA: Si se acumula humedad en las paredes o ventanas del
cuarto, apague el humidificador. El cuarto ya tiene demasiada
humedad y la humedad adicional puede causar daños.
NOTA: NO bloquee la entrada o salida de aire.
Instrucciones de Seguridad en la Instalación del
Cable y el Enchufe:
La longitud del cable de este artefacto fue seleccionada para
reducir el riesgo de enredarse o tropezarse con un cable más
largo. Si necesita usar un cable más largo, puede utilizar un
cable de extensión aprobado. La capacidad eléctrica del cable
de extensión debe ser igual o mayor que la capacidad del
humidificador (consulte la información de capacidad que
aparece en el humidificador). No debe permitir que el cable de
extensión cuelgue de la mesada o mesa de tal forma que
pueda ser halado por niños o causar que alguien se tropiece.
CÓMO FUNCIONA EL AIRE CALIENTE
El humidificador de vapor caliente de Sunbeam® está
diseñado para permitir que fluya la cantidad adecuada de
agua del depósito y pase por la cámara de calentamiento
en donde el elemento de calentamiento del control
electrónico térmico calienta el agua. El aire pasa a través
de las aperturas de la rejilla que se encuentra en la parte
trasera de la unidad y se mezcla con vapor en el
receptáculo nebulizador. El vapor caliente sale por la
parte superior del receptáculo nebulizador a través de la
rejilla de salida y penetra en la habitación.
NOTA: Un nivel de humedad menor al 20% puede ser
nocivo e incómodo. El nivel de humedad recomendado es
entre el 40% y el 50%.
INSTRUCCIONES PREVIAS AL USO
1. Asegúrese de que el humidificador esté apagado.
2. Escoja una ubicación para su humidificador, sobre
una superficie plana y nivelada, separada unas 4" de
la pared. NO coloque el humidificador sobre un piso
o cerca de muebles que puedan ser dañados por la
humedad o el agua. Colóquelo sobre una superficie
resistente a la humedad.
3. Retire el tanque de la caja principal.
4. Acerque el tanque hasta la pileta, délo vuelta y
desenrosque la tapa del tanque girando en sentido
contrario a las agujas del reloj. Llene el tanque con
agua fría del grifo. NO llene con agua caliente ya
queestopuedeproducirunapérdida.Vuelvaa
colocar la tapa del tanque CON FIRMEZA. El tanque
tiene una capacidad de 1 galone de agua.
5. Asegúrese de que la cerradura de seguridad haya
girado completamente hasta la posición de bloqueo.
Ponga el tanque de nuevo en su alojamiento. El tanque
comenzará a vaciarse inmediatamente en la base.
6. Enchufeelhumidificadorenuntomacorrientede120V.
BANDEJA PARA MEDICAMENTOS
Hay una bandeja para medicamentos en la parte superior del
enrejado de la cámara de vapor. Para utilizarlo, vierta la
medicación designada para el humidificador en la bandeja y
enciéndalo como se indica.
NOTAS:
• NOagreguemedicamentosaltanquedeagua.
• NOagreguemedicamentosalabandejacuandola
unidad se encuentre en funcionamiento.
CARACTERISTICA - FUNCIONAMIENTO
INSTRUCCIONES DE USO
IMPORTANTE:
1. Presione el botón de encendido (
la unidad.
NOTA: Este humidificador de vapor cuenta con una
característica de vapor rápido. Después del
encendido, el humidificador comenzará a producir
vapor en 1 minuto. Es normal escuchar un ruido de
ebullición. Para reducir al mínimo el nivel de ruido,
opere la unidad en una configuración baja.
* El vapor visible producido en menos de 1 minuto
fue medido utilizando agua a una temperatura
promedio de 65 °F (18 °C).
2. Después de que la unidad comience la vaporización,
el humidificador funcionará en una configuración alta
(la luz indicadora de configuración alta se ilumina).
Presione el botón Mist (
configuración baja y luz indicadora de configuración
baja se iluminará.
3. Para apagar el humidificador, vuelva a presionar el
botón de encendido hasta que todas las luces se
apaguen.
ADVERTENCIA: NOMUEVAelhumidificadorcuando
tenga agua en el tanque o en la base. La acción de
movimiento podría activar la boquilla de descarga del
tanque de agua y saturar la base del humidificador. Si
sucediera, el humidificador funcionaría intermitentemente
y dejaría de emitir vapor. En este caso, simplemente
elimine el exceso de agua de la base del humidificador.
Figura 1
A. Tanque del
B. Cubierta del
C. Base del Humidificador
G
F
E
D
Humidificador
Humidificador
) para encender
) para cambiar a la
A
B
C
D. Botón de encendido ( )
E. Botón de vapor( )
F. Luces indicadoras Hi/Lo
G. Cámara nebulizadora con
Bandeja para medicina
PROCEDIMIENTO DE REINICIO
Cuando se agota el agua del tanque y casi se ha terminado
el agua en la cámara de calor, se activará el apagado
automático para evitar el recalentamiento. El
humidificador dejará de funcionar hasta que se llene
nuevamente el tanque y se reinicie del siguiente modo:
1. APAGUE el humidificador y desconéctelo.
2. Retire y vuelva a llenar el tanque de agua, siga las
instrucciones de "Mantenimiento Diario" y de
"Funcionamiento previo" para limpiar y volver a
llenareltanquedeagua.Vuelvaacolocareltanque
en la base.
3. Espere 15 minutos para que el Apagado Automático
se reinicie.
4. Después de 15 minutos, conecte la unidad y
ENCIENDA el humidificador para que comience a
funcionar. En aproximadamente 1 minuto, la unidad
comenzará a producir humedad. Si la unidad no
empieza a funcionar es que todavía está demasiado
caliente. Desenchufe la unidad, espere unos 15 a 30
minutos más, y conecte de nuevo la unidad. Ahora la
unidad debe de estar lo suficientemente fría y
funcionar con normalidad.
INSTRUCCIONES DE LIMPIEZA Y
MANTENIMIENTO
Los siguientes procedimientos de mantenimiento
se deben seguir rutinariamente para poder asegurar
un funcionamiento correcto y eficiente de su
PANEL DE CONTROL
F
E
D
humidificador. La unidad NO FUNCIONARÁ
CORRECTAMENTE si no se la limpia de manera
adecuada.
Cuando la unidad está en uso, se recomienda realizar
mantenimientos diarios y semanales. Las limpiezas
semanales regulares evitan la acumulación de sarro en el
calentador y la base. Además impide el crecimiento de
microorganismos en la base. Esto garantiza que se pueda
lograr una máxima eficiencia.
No exageramos cuando hacemos hincapié en la
importancia de una limpieza adecuada para lograr
un mantenimiento y uso continuo de su unidad y
para evitar la acumulación de algas o bacterias.
MANTENIMIENTO DIARIO
Permita que se enfríe antes de realizar el
mantenimiento.
1. Antes de la limpieza, apague el humidificador y
desconecte la unidad de la toma eléctrica.
2. Retire el tanque de agua, luego desbloquee la
cubierta del humidificador girando el cierre de
seguridad hacia el frente de la unidad. Levante la
cubierta de la base de la humidificador
(ver la Figura 2).
Figura 2
Cierre de
seguridad
Base
3. Retire el agua y los minerales de la base y colóquela en
el estante superior del lavavajillas. Esto eliminará los
sedimentos y la suciedad que se ha acumulado en la base.
LIMPIEZA / MANTENIMIENTO
NOTA: Es sumamente importante que la base se limpie
correctamente. La base se puede lavar en el lavavajillas
(ÚNICAMENTE en el estante superior) con facilidad.
4. Pase un paño suave sobre el calentador para
limpiarlo una vez que se haya enfriado.
5.
Vuelvaacolocarlacubiertadelhumidificadory
ajuste el cierre de seguridad. El Calentador con
regulación térmica electrónica está revestido con una
capa que está diseñada para proporcionar una
limpieza más sencilla y prolongar la eficiencia
operativa del humidificador. NO utilice ningún objeto
duro o de metal para limpiar el Calentador. Nunca
utilice detergentes, gasolina, kerosén, limpiador de
cristales, lustramuebles, diluyente de pintura u otros
solventes para el hogar para limpiar cualquier parte
del humidificador.
MANTENIMIENTO SEMANALE
Extraer el sarro: Permita que se enfríe antes de
realizar el mantenimiento.
1. Repita los pasos 1 al 5 de la sección Mantenimiento
Diario.
2. Limpiar bandeja y el elemento calefactor y de
elemento calentador mortaja llenando la bandeja con
una solución de agua que contiene 8 onzas de
vinagre blanco sin diluir. Permitir bandeja, elemento
El cierre de segridad en base
desbloquee
Cubierta
de calentamiento y de elemento calentador mortaja a
sentarse en una solución de agua durante 20
minutos. Limpie la bandeja, el elemento de
calefacción y de elemento calentador cubierta con un
cepillo suave. Humedezca un paño con vinagre
blanco sin diluir y eliminar toda la bandeja / base,
elemento de calefacción y el elemento calefactor
cubierta zona para retirar el sarro.
3. Enjuague con agua tibia para quitar la escama y la
solución de vinagre blanca antes de comenzar a
desinfectar el tanque.
4. Friegue suavemente el elemento calefactor y sus
alrededores con un cepillo suave.
Desinfectar el Depósito:
1. Llene el tanque con 1/2 cucharadita de blanqueador
clorado y 1/2 galón (1.9L) de agua.
2. Deje reposar las partes en la solución durante 20
minutos, removiéndolas de vez en cuando.
Humedezca todas las superficies.
3. Vacíeeltanquedespuésde20minutos,yenjuague
bien con agua hasta que el olor del blanqueador
haya desaparecido. Seque con un paño limpio o
toallita de papel.
4. Vuelvaallenareltanquedeaguaconaguafría;
vuelva a poner el tanque de agua. Repita TODAS las
instrucciones de funcionamiento.