Sumo Seeder Quick Start Manual

Page 1
Sumo UK Ltd Redgates Melbourne York YO42 4RG Tel. 01759 319900 Fax. 01759 319901
Figure 2: Change Implement Width
Figure 1: View Implement Width
Figure 4: Adjust Target Rate
Figure 3: View current Target Rate
Quick Start Guide
1.0 Set Implement Width
1. Select the Area Total channel ( ).
2. Press and hold the button for 5 seconds. The display will flash "tot.1", then "tot.2" then shows the programmed implement width (fig. 1).
Default width = 4 metres.
3. Continue holding the button and PRESS to select the digit/decimal point to change.
4. HOLD to change the digit (or move the decimal point). Releasing the button selects the next digit (fig. 2).
5. Release the button to return to the normal display mode.
2.0 Changing the Target Rate
When the drilling rate is currently at the target rate:-
1. With the rate display selected, press and hold either the button or the
button for 5 seconds (fig. 4) until the number is flashing, then release.
2. Press either the button to increase the target rate (KG/Ha), or the button to decrease the target rate (KG/Ha) (fig. 4). The longer the button is held, the faster the number changes. Release the button.
3. When the desired target rate (KG/Ha) is displayed, press and hold the button. The instrument will beep 5 times and the display will alternate between the set rate and the calculated minimum forward speed for that rate.
After 5 seconds the instrument will display ‘done’ after which the button can
be released to return to normal operating mode.
Page 2
Sumo UK Ltd Redgates Melbourne York YO42 4RG Tel. 01759 319900 Fax. 01759 319901
Figure 5: Prime button
Figure 6: Seeder unit
Figure 7: Calibration tray
3.0 Calibration
1. Switch the ‘FAN’ switch to the off (‘O’)
position on the junction box. This automatically enables the product calibration function.
2. Remove the calibration slide as shown
3. Remove the calibration tray, weight it and Zero the
scales.
4. Press and hold the prime button (fig 5). The display will
count up the theoretical weight (in grams) of product based on the calibration factor currently stored in memory.
5. Once you have dispensed sufficient product, release the priming switch
and weigh the product metered in grams. The theoretical weight will remain flashing on the display.
NOTE 1: If the priming switch is held for long enough to exceed 9999 grams then the
instrument will simply show ‘HiGh’, informing the operator that he must re-test to ensure the weight does not exceed 9999 grams. Simply release the PRIME button and press again when ready to restart the count from zero.
6. Adjust the displayed weight to match the measured weight (in grams) using the or buttons.
7. Press the button once to display the calculated minimum forward speed (see note 2 below).
8. Press the button again to save the new calibration factor. The instrument displays ‘done’ to indicate
the new factor is now stored. After 3 seconds the instrument reverts back to the normal operating mode.
9. Repeat the test as many times as necessary so the measured rate is within a reasonable range of the
displayed weight.
10. Switch the ‘FAN’ switch back on and refit the calibration tray and calibration slide and secure with the
lynch pin
NOTE 2: If you find that the minimum forward speed is too high at low application rates you should change the
feed roll to a lower volume roll and re do the product calibration.