SUMAVISION TECHNOLOGIES EMR3B Operating Instructions Manual

SUMAVISION
Operating Instructions
Integrated Media Processing Platform
Enhanced Multimedia Router
SUMAVISION TECHNOLOGIES CO., LTD.
SUMAVISION EMR Operation Introduction
Introduction
Version Description
Sumavision Technologies Co., Ltd. Copyright and all rights reserved. Without paper permission of Sumavision Technologies Co., Ltd, any company or individuals are not allowed to extract, copy part or all of this book, and spread in any form. The product in this manual is: Enhanced Multimedia Routeran integrated media processing platform The version of this manual is V1.5. This manual provides complete configuration introductions of EMR series. User can choose to read relevant parts of this manual according to the equipment purchased. Any change or version upgrade of this manual will not notice again.
The Agreements of the Instructions
Before reading the Instructions, please read the following agreements carefully:
1. Font and format
The texts in the Instructions are prepared by using V Arial typeface;  The first-level titles in the Instructions are prepared in bold using II Arial typeface,
the second-level titles are prepared in bold using III Arial typeface, and the third-level titles are prepared in bold using IV Arial typeface;
All the notes of the Instructions are prepared by using regular Arial, and are
separated before and after the texts by using "=======";
2. Keyboard operation The Arial characters in “<>” refer to the key name or button name, for instance
<Enter>, <Tab>, <Back Space> are refer to Return, Tab, Backspace respectively.
<Key 1 + Key 2> refers to pressing the key 1 and key 2 on the keyboard at the same
time, for instance <Ctrl+Alt+A> refers to pressing "Ctrl", "Alt" and "A" three keys at the same time.
< Key 1, Key 2> refers to pressing Key 1 first on the keyboard, releasing, and then
pressing Key 2, for instance <Alt, D> refers to pressing <Alt> key, after releasing the key and then pressing <D> key.
3. Mouse operation
Click: Quickly press and release a mouse button.  Double-click: Press twice quickly and release a mouse button.  Drag: Hold down a mouse button, and move the mouse.
4. Signs
SUMAVISION EMR Operation Introduction
Note, carefulness, warning and danger: to remind users the matters should be
paid attention to in the day-to-day maintenance and operation.
Description, prompts and tips: to necessarily add and describe the descriptions
of the operation contents.
Help: to describe in detail the parts of the operation contents that it is not easy for
users to understand.
Target Readers
This manual introduces the functions and methods of using and maintaining the integrated media processing platform--EMR, and is applicable to the following readers:
Digital video/audio engineering technicians  Digital video/audio system administrators  Digital video/audio system engineers
Contact Us
Sumavision Technologies Co., Ltd. is committed to providing a full range of technical support. When users are not familiar with the device or any fault of the device occurs, it is recommended not to disassemble the device, but to contact Sumavision Office or the After-sales Technical Support Department of the Company. You can contact us by the following addresses: Address: Building 1, No.15 Kaituo Road, Shangdi Information and Industry Base, Haidian District, Beijing ,CHINA, 100085 After-sales Technical Support Hotline: 8008103018 24-hour hotline: Website: www.sumavision.com
SUMAVISION EMR Operation Introduction
Content
SUMAVISION ......................................................................................................................................... 1
OPERATING INSTRUCTIONS ............................................................................................................ 1
CHAPTER 1 OVERVIEW .............................................................................................................. 1
1.1 NETWORK SOLUTION ................................................................................................................ 1
1.2 MAIN PERFORMANCE PARAMETERS ......................................................................................... 1
1.3 APPLICABLE STANDARDS ......................................................................................................... 2
CHAPTER 2 PRODUCT DESCRIPTIONS .................................................................................. 3
2.1 PRODUCT IDENTIFICATION ........................................................................................................ 3
2.2 APPEARANCE ............................................................................................................................ 3
2.2.1 Indicator .............................................................................................................................. 3
2.2.2 LCD ..................................................................................................................................... 4
2.2.3 Keyboard Operating ............................................................................................................ 5
2.2.4 Connector of the Device ...................................................................................................... 5
2.2.5 Interface Performance ......................................................................................................... 6
2.3 HEAT EMISSION DESCRIPTIONS ................................................................................................ 8
2.4 CONTROL DESCRIPTIONS .......................................................................................................... 8
CHAPTER 3 SAFETY PRECAUTIONS ....................................................................................... 9
3.1 OUTLINE DIMENSIONS .............................................................................................................. 9
3.2 WEIGHT .................................................................................................................................... 9
3.3 ENVIRONMENTAL REQUIREMENTS ............................................................................................ 9
3.3.1 Requirements on Transportation Environment .................................................................... 9
3.3.2 Site room environmental requirements ................................................................................ 9
3.3.3 Power supply Requirement ................................................................................................ 11
3.4 STORAGE ................................................................................................................................ 11
3.5 TRANSPORT ............................................................................................................................ 11
CHAPTER 4 INSTALLATION AND DEBUGGING ................................................................ .. 12
4.1 UNPACKING AND CHECKING ................................................................................................... 12
4.2 INSTALLATION PRECAUTIONS ................................................................................................. 12
4.3 STEPS AND METHODS OF INSTALLATION ................................................................................. 12
4.4 DEBUGGING ............................................................................................................................ 13
4.5 METHODS FOR DEBUGGING AND TESTING .............................................................................. 14
4.6 DEVICE UPGRADE ................................................................................................................... 14
CHAPTER 5 OPERATING METHODS ...................................................................................... 16
5.1 WEB NETWORK MANAGEMENT .............................................................................................. 16
5.1.1 System Setting .................................................................................................................... 17
5.1.2 Operating Method .............................................................................................................. 19
5.2 BOARD CARD DESCRIPTION ................................................................................................... 22
5.2.1 Main Gigabit Card ............................................................................................................ 22
5.2.2 ASI 5-channel Input Card .................................................................................................. 29
5.2.3 ASI 4-channel Output Card ............................................................................................... 29
5.2.4 6-adjacent-channel QAM Modulation Card ...................................................................... 30
5.2.5 4-frequency DVB-T2 Demodulation Receiving Card ......................................................... 32
5.2.6 Analog SD MPEG2 Encoding Card................................................................................... 32
5.2.7 HD 422 Decoding Card ..................................................................................................... 33
5.2.8 4-frequency DVB-S2 Demodulation Receiving Card ......................................................... 34
5.3 WEB NETWORK MANAGEMENT FOR SCRAMBLING MODULE .................................................. 35
5.3.1 System Setting .................................................................................................................... 36
5.3.2 Program Scramble ............................................................................................................. 39
5.3.3 Port Setting ........................................................................................................................ 40
5.3.4 CAS Setting ........................................................................................................................ 41
5.3.5 EMM Setting ...................................................................................................................... 41
CHAPTER 6 DESCRIPTIONS OF ADVANCED ........................................................................ 43
SUMAVISION EMR Operation Introduction
6.1 OUTPUT SETTINGS .................................................................................................................. 43
CHAPTER 7 FAULT ANALYSIS AND TROUBLESHOOTING .............................................. 44
7.1 ALARM INFORMATION ............................................................................................................ 44
7.1.1 LCD does not display after powering on ........................................................................... 44
7.1.2 ASI 5-channel input card fails to refresh any input signals. .............................................. 45
7.1.3 ASI 4-channel output card fails to output the decoding normally ..................................... 45
7.1.4 6-adjacent-frequncy QAM modulation card output can’t be received by STB. .................. 46
7.1.5 The main Gigabit card inputs no system bit rate. .............................................................. 46
7.1.6 The main Gigabit card outputs abnormally ....................................................................... 46
CHAPTER 8 MAINTENANCE .................................................................................................... 47
8.1 MAINTENANCE METHOD ......................................................................................................... 47
8.2 MAINTENANCE DETAILS ......................................................................................................... 47
8.3 ROUTINE MAINTENANCE ......................................................................................................... 48
8.4 MONTHLY MAINTENANCE ....................................................................................................... 48
8.5 QUARTERLY MAINTENANCE ................................................................................................... 49
8.6 ANNUAL MAINTENANCE ......................................................................................................... 49
8.7 CLEAN-UP AND MAINTENANCE ............................................................................................... 49
8.8 OPERATION AND MAINTENANCE ............................................................................................. 50
ANNEX A .............................................................................................................................................. 51
SUMAVISION EMR Operation Introduction
1 /53
Chapter 1 Overview
SUMAVISION Enhanced Multimedia Route, which can be abbreviated to EMR, is a new generation multi-media exchange platform. This device, which uses 1U card plug-in structure, and supports at most 6 boards (cards) as well as dual-power redundancy backup. The platform integrates multiple functions such as encoding, decoding, multiplexing, modulation, IP input/output and adaption, can be configured flexibly according to the different needs of users, and meet the vast number of operators’ demands for integrated devices and multiple functions in the process of digital TV head-end platform construction sufficiently .
1.1 Network Solution
The typical networking of EMR is shown as Fig. 1-1 EMR Network solution Diagram.
Fig. 1-1 EMR Networking Diagram
In Fig. 1-2 EMR Network solution Diagram, EMR receives and encodes & compresses the analog or digital TV video & audio signals; and can also receive and adapt the adaptive signals such as DS3 and ATM; additionally, it can receive and demodulate the satellite signals as TS, and transmit them into the multiplexer, then multiplex with EPG information to become a standard DVB stream, which will be encrypted by the scrambler and CAS, and modulated by the modulator and finally transmitted on HFC network.
1.2 Main Performance Parameters
Main performance parameters of EMR are shown as follows: Support MPEG-2, H.264 standard encoding
SUMAVISION EMR Operation Introduction
2 /53
Support the encoding of HD and SD video resolutions  Audio encoding: Dolby AC3 and MPEG-1 Layer II  Support DS3, ATM and other adaption format  Support Gigabit Ethernet input/output  Support multi-channel ASI output  Support ASI, DS3 and RF signal backup and switching  Support bit rate shaping and statistical multiplexing  The encoding supports at most 12-channel AV or SDI input and 24-channel
single-track balanced audio input
Support DVB-S/DVB-S2 descrambling and receiving, and support at most 6-channel
DVB-S2 signal input descrambling
Support BISS descrambling  DVB-S/DVB-S2 receiving supports at most 24-channel satellite receiving and
multiplexing
DVB-T/DVB-T2 receiving supports at most 24-channel Terrestrial signal receiving
and multiplexing
Support digital SDI (embeddable audio) and digital audio input  Support PCR correction, PSI/SI table editing and inserting functions  Built-in comb filter and time-base correction circuitry, significantly reducing the
requirements for signal sources
Card-insertion 1U stand-alone structure, which can be used flexibly and
conveniently
Support key-press LCD operations  Support SNMP network management functions
1.3 Applicable Standards
EMR is in compliance with the national and industrial standards, including: GB/T 17975.2-2000 Information technology--Generic coding of moving pictures
and associated audio information--Part 2: Video
GY/T 170-2001 Specifications of framing structure, channel coding and modulation
for digital cable broadcasting system.
SUMAVISION EMR Operation Introduction
3 /53
Chapter 2 Product Descriptions
2.1 Product Identification
There are product name, model and manufacturer, etc. on the front panel of EMR, as shown in Fig. 2-1 EMR Front Panel.
Fig. 2-1 EMR Front Panel
Product name: Integrated Media Processing Platform Model: EMR3.0, as shown in Fig. 2-2 EMR Front Panel. Manufacturer: Sumavision Technologies Co., Ltd., as shown in Fig. 2-3 EMR Front
Panel. Identification description: there’s the ex-factory identification on the rear panel of the
device, as shown in Fig. 2-2 Ex-factory Identification.
Fig. 2-4 Ex-factory Identification
Where, “S/N” refers to the ex-factory serial number, “EMR3B stands for the device model and “081006” is the production code.
2.2 Appearance
EMR appearance is shown as Fig. 2-3 EMR Appearance.
Fig. 2-3 EMR Appearance
2.2.1 Indicator
There are 8 indicators on EMR front panel, including:
Power
Installed
component
Indicator
LCD display
Control & scrambling
Gigabit input/output
EMR3B081006
Name & Model
Company’s trademark
SUMAVISION EMR Operation Introduction
4 /53
Run/Alarm Operating indicators (1-6)
Connect to the power supply and turn on the power switch, the indicator of Power keep lighting. When the device starts and operates normally, there is no abnormalty, the indicator of Run/Alarm on the device panel will turn green. When the device operates abnormally, the indicator of Run/Alarm on the device panel will turn red, which prompts the user that an error has occurred. Operating indicators of 1 to 6 are used to indicate the operating status of slot 1 to 6 respectively, and the indicator of Alarm is used to indicate the device status. =======================================
After the device has been powered on, generally the indicator of power will keep
lighting once the device is started.
======================================= Table 2-1 Description for the operating status of indicator 1: lists the operating status of
indicator 1 by taking one MPEG2 analog encoding card in slot 1 as an example.
Table 2-1 Description for the operating status of indicator 1:
Indicator 1 can be divided into six kinds of status as shown in the table above, “Y” stands for normal or Yes; “N” refers to abnormal or No; "-" denotes the content has nothing to do with this item. For detailed alarm contents, please query in [Status Information] of sub-cards in the menu of the device or in [Alarm Display] of Sumavision network management system. The operating indicator of slot 2, 3, 4, 5 and 6 has the same status of indicator 1. Here no repeated description will be made.
2.2.2 LCD
Users can check IP address of the device and alarm information by querying LCD. Touch
Operating
indicator
No.
Encoder
Signal
source
Multiplexing
or not
Indicator
result
Slot
Indicator 1
1
Encoder 1
Y
Y
Green
Slot 1
Encoder 2
Y
Y
2
Encoder 1
Y
Y
Encoder 2
N
3
Encoder 1
N
Encoder 2
Y
Y
4
Encoder 1
N
Encoder 2
N
5
Encoder 1
Y
Red
Encoder 2
N
Y
6
Encoder 1
N
Y
Encoder 2
Y
SUMAVISION EMR Operation Introduction
5 /53
LCD button to display IP and subnet mask information of the device, press and hold the LCD button to display current alarm information of the device.
2.2.3 Keyboard Operating
User can enable the LCD panel through keyboard to view the IP of the device.
2.2.4 Connector of the Device
SUMAVISION EMR rear panel adopts the form of sub-panels. 6 slots formed with 6 sub-panels can be handled independently, which can facilitate the plugging and un-plugging of sub-cards. Ground terminal, power switch are placed on the rear panel, see Fig. 2-4 Appearance of SUMAVISION EMR rear panel. Definition of slot: lower left Slot 1; lower center Slot 2; lower right Slot 3; upper left Slot 4; upper center Slot 5; upper right Slot 6.
Fig. 2-5 Appearance of SUMAVISION EMR Rear Panel
The corresponding relationship between the function board and the slot used is shown in Table 2-1 Function board and the slot used. =======================================
User can select to read relevant part of the Instructions according to the function
board/card purchased.
=======================================
Table 2-2 Function board and the slot used
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
ASI 5-input card
▼ ▼ ▼ ▼ ▼
ASI 4-output scrambling card
▼ ▼ ▼ ▼ ▼
6-adjacent-channel QAM
modulation card
▼ ▼ ▼ ▼ ▼
4-frequency DVB-T2
Demodulation Receiving
Card
▼ ▼ ▼ ▼ ▼
Analog SD MPEG2 Encoding
Card
▼ ▼ ▼ ▼ ▼
HD 422 Decoding Card
▼ ▼ ▼ ▼ ▼
4-frequency DVB-S2
Demodulation Receiving
Card
▼ ▼ ▼ ▼ ▼
SUMAVISION EMR Operation Introduction
6 /53
2.2.5 Interface Performance
2.2.5.1 ASI 5-input card
ASI 5-input card provides 5-channel 75ΩBNC interface for ASI signal input, as shown in Fig. 2-6 ASI 5-input card:
Fig. 2-7 ASI 5-input card
2.2.5.2 ASI 4-Output Scrambling Card
ASI 4-Output Scrambling Card provides 4-channel 75ΩBNC interface for ASI signal output, and an Ethernet interface for CAS connection, as shown in Fig. 2-8 ASI 4-Output Card:
Fig. 2-9 ASI 4-Output Card
2.2.5.3 6-adjacent-channel QAM modulation card
6-adjacent-channel QAM modulation card provides one 6-adjacent-channel RF output interface for the output of modulated signals, and one Ethernet interface for connecting and communicating CAS, as shown in Fig. 2-7 6-adjacent-channel QAM Modulation Card:
Fig. 2-10 6-adjacent-channel QAM modulation card
2.2.5.4 4-frequency DVB-T2 Demodulation Receiving Card
4-frequency DVB-T2 Demodulation Receiving Card provides four RF input interfaces, for
DVB-T/T2 standard RF signal reception. 4-frequency DVB-T2 Demodulation Receiving
Card is shown in Fig. 2-8.
Fig. 2-8 4-frequency DVB-T2 Demodulation Receiving Card
SUMAVISION EMR Operation Introduction
7 /53
2.2.5.5 Analog SD MPEG2 Encoding Card
Analog SD MPEG2 Encoding Card provides the video input interface of 75ΩBNC, and provides audio input interface as the phoenix printed circuit board terminals of MINI COMBICON (MC) socket and plug, plug direction parallel with conductors axial. Analog SD MPEG2 Encoding Card is shown in Fig. 2-9.
Fig. 2-9 Analog SD MPEG2 Encoding Card
2.2.5.6 HD 422 Decoding Card
HD 422 Decoder Card has two types hardware 2.0 as Fig. 2-10, hardware 3.2 as Fig. 2-11. Hardware 2.0 provides two HD-SDI digital video output interfaces, one group of analog video output interfaces CVBS / YPbPr , 2 AES / EBU digital audio output interfaces, and also an analog audio (balanced) output interface with the interface of phoenix printed circuit board terminal MINI COMBICON (MC) type socket. Hardware 3.2 provides one GENLOCK frame synchronization signal input interface, two HD-SDI digital video output, an CVBS analog video output interface, two AES / EBU digital audio output interfaces, 2 audio output interfaces with DB-9 (male), which contains an analog balanced audio and an digital balanced audio.
Fig. 2-10 HD 422 Decoding Card (hardware 2.0)
Fig. 2-11 HD 422 Decoding Card (hardware 3.2)
2.2.5.7 4-frequency DVB-S2 Demodulation Receiving Card
4-frequency DVB-S2 Demodulation Receiving Card provides four RF input interfaces for
DVB-S/S2 standard RF signal reception, Fig. 2-12 shows 4-frequency DVB-S2
Demodulation Receiving Card.
SUMAVISION EMR Operation Introduction
8 /53
Fig. 2-12 4-frequency DVB-S2 Demodulation Receiving Card
2.2.5.8 Power socket
EMR provides two power sockets on the rear panel. The device will be powered on if the power lead is insert the power socket correctly. The power sockets used by EMR fully conform to the international industrial standards, for detailed information, refer to Table 10-3 Power Socket Parameters.
2.3 Heat Emission Descriptions
There are two exhaust fans installed inside the EMR to lower the risen temperature caused by the working chips during the operation of the device. EMR exhaust flow is shown as Fig.2-13 Exhaust Diagram.
Fig. 2-13 Exhaust Diagram
=======================================
Do not block the exhaust channel when installing the device.
=======================================
2.4 Control Descriptions
The integrated media processing platform-- SUMAVISION EMR can achieve the control through Web and SNMP network management system.
Exhaust channel
Inlet channel
Inlet channel
SUMAVISION EMR Operation Introduction
9 /53
Chapter 3 Safety Precautions
3.1 Outline Dimensions
EMR external structure is shown as Table 3-1 EMR Physical Parameters.
Table 3-1 EMR Physical Parameters
Physical Parameters
Value (Unit)
Height
44.4mm (1U)
Width
482.6mm (19")
Depth
564.7mm
3.2 Weight
The device weights <7.5kg, and its specific quality is related to the configurations of the device. Please be subject to the device actually purchased.
3.3 Environmental Requirements
3.3.1 Requirements on Transportation Environment
The device must be handled prudently and carefully to avoid damages to the device. Ensure that people who transport, maintain or operate the device have professional skills and are familiar with the operation of device. If there’s any question during the transport, maintenance and operation of the device, please contact the Aftersales Technical Support Department of Sumavision, with the way to contact refering to the foregoing contents. The device is high-grade electronic product, and should be handled gently and kept away from falling or collision. And additionally, attention should be paid to the following: Please do not place this device on unstable trolleys, shelves, brackets or tables, otherwise, the device may fall and cause serious damages, which can lead to abnormal operation. During transportation, the trolley used to transport the device should be kept balance. When user has arrived at the designated location or have to stop on the way, ensure whether the trolley is reliable first, and then stop moving to aviod the falling of device, causing malfunction. Please arrange special person to transport or install this device, and avoid many persons participating in the transportation.
3.3.2 Site room environmental requirements
Site room area: The front door and back door of the cabinet should leave at least 1.2m to 1.5m for opening
SUMAVISION EMR Operation Introduction
10 /53
the door or routine maintenance. The cabinet can not be installed against the wall, and the distance between the cabinet side and the wall should be not less than 0.8m. Site room floor: Site room floor should be non-conductive, dust-proof, and its surface smoothness error should be less than 2mm per square meter. The volume resistivity of anti-static material should range from 1×10
7
Ω to 1×10
20
Ω, and the ground current-limiting resistor is 1MΩ. Floor load-bearing should be larger than 450kg/ m2. Environment temperature: The device can operate normally in the environment whose temperature ranges from 10 to 40, and the places where conditions permit can install air-conditioning system for cooling. Relative humidity: Normal working humidity: ≤90% (20); Allowed working humidity: ≤95% (without condensation). Environmental pressure: 86-105kpa. Site room doors and windows: Doors and windows of the site room should be sealed with dust-proof rubber strips, and windows should be double-glazed and strictly sealed. Site room wall suface: The wall suface of site room can use wallpapers or be printed with lusterless paint, however, powder coating is not suitable. Air cleanliness: The requirements are shown as Table 3-2 Site room dust indicators and Table 3-3
Table 3-2 Site room dust indicators
Maximum diameter (μm)
0.05
1.00
3.00
5.00
Maximum concentration (particles per cubic meter)
14×105
7×105
24×104
13×104
Table 3-3 Site room harmful gas indicators.
Gas
Average (mg/m3)
Max. (mg/m3)
Sulfur dioxide SO2
0.20
1.50
Hydrogen sulfide, H2S
0.01
0.30
Nitrogen dioxide, NO2
0.04
0.15
Ammonia, NH3
0.05
0.15
Chlorine, Cl2
0.01
0.30
Fire-fighting requirements: Site room should be equipped with automatic fire alarm system, hand-held extinguishing
SUMAVISION EMR Operation Introduction
11 /53
system or fixed extinguishing system. Power supply requirements: The devices, air-conditioning system and lighting system should have their own power system respectively.
3.3.3 Power supply Requirement
Parameters for normal operation of EMR are shown as follows:
Power supply:
Voltage: 100V-240V AC; Power frequency: 50Hz-60Hz
Power consumption:: < 100W Nominal fuse: 2A Grounding: the device should be well grounded through the ground
terminal.
3.4 Storage
Requirement: Humidity: ≤95% (20)
Temperature: -20℃~60
Don’t store with corrosive liquids and gases. Don’t place the device nearby strong electromagnetic fields.
Prohibit infection by radioactive substances.
3.5 Transport
EMR is packaged by using the special packaging of Sumavision. In case of intact packaging, such transportation modes like highway, railway, airline and shipping are acceptable. In case of damaged packaging, the device should be transported after being packaged by professional electronic product transportation companies. During the transportation, the device should be handled gently to avoid throwing, falling or severe collision, and kept the labeling on the package upward.
SUMAVISION EMR Operation Introduction
12 /53
Chapter 4 Installation and Debugging
4.1 Unpacking and Checking
Please check whether the package of the device is damaged or not when receiving the device; in case of devices damage, please contact the carrier company or the After-sales Technical Support Department of Sumavision in a timely manner. If you complete the installation and debugging of the device by yourself, please pay attention to the deformation of device and abnormal sound inside the device when unpacking the device; check whether the device model and name are in conformity with those specified in the contract; whether the serial number of device is identical to that in the Delivery and Maintenance Certificate of Device; and whether the power lead, connectors and fittings, operating instructions and Certificate of Fitness are completely contained in the package case of the device. If the installation and debugging are conducted by the after-sales technical engineers of Sumavision, they will confirm the above-mentioned information with you. You are required to sign and return the Delivery and Maintenance Certificate of Device to our company after confirming there’s no problem upon the unpacking and inspection, and according to which we’ll provide high-quality satisfactory after-sales services.
4.2 Installation Precautions
Check whether the environmental requirements in Section 3 of Chapter III have been met. The device can be powered on for debugging after the installation is completed by following the installation steps.
4.3 Steps and Methods of Installation
EMR needs to be installed and used on a 19-inch cabinet. When installing the device, please open the box first, then take out the device. To ensure the device is installed firmly, please put the device on L bracket after installing L bracket on the cabinet, and fasten the device on the assembly cabinet with screws. Device installation can be shown as Fig. 4-1 Assembly cabinet for EMR.