SUCACO SUPREME CABLE Catalog

Page 1
Company
Background
pecializing in the cable business since 1970, PT SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT SUCACO Tbk.) has
S
with international reputation for quality and reliability. Established in 1970, PT SUCACO Tbk. is a pioneer in the modern industry. With technical assistance from Furukawa Electric Co Ltd. Japan and International Executives Service Corp, USA, the company began commercial operations in 1972.
We produce and markets power cable up to 150 kV, optical and telecommunication cables, control cables, instrumentation cables, coaxial cables, re resistant cable, airport lighting cable, aluminium bare over head conductors and enamelled wires under brand name of “ SUPREME “. The Company is also involved through its a󱐰liated companies, in various line of business. The company has a Quality Assurance Program and ISO 9001
grown steadly to become a largest and leading cable manufacturer,
certicate from SGS international certication body of quality management system, ISO 14001 for environment management system and ISO 18001 for safety management system. Today, PT SUCACO Tbk. has grown to become a reliable partner in infrastructures, buildings and various projects.
Page 2
2
Page 3
FLEXIBLE CABLE
TABLE OF CONTENT PAGE
Company Background
NYAF 450/750 Volt 1
NYMHY 300/500 Volt 2
NYYHY 450/750 Volt, 2 cores 3
NYYHY 450/750 Volt, 3 cores 4
NYYHY 450/750 Volt, 4 cores 5
NYYHY 450/750 Volt, Control 6
LiYCY 300/500 Volt 7
LiYCY 300/500 Volt, Control 8 - 10
Conversion Table 11
Page 4
NYAF 450/750 Volt
SNI 04-6629.3/SPLN 42-3 / IEC 60227-3
SINGLE CORE , FLEXIBLE COPPER CONDUCTOR AND PVC INSULATED CABLE
Applications:
• Fixed internal wiring with low mechanical stress for electrical equipments, machineries, distribution panels, luminaires and other electrical appliances used in dry indoor premises, substitutes NYA.
• Permanent installation in conduit, inherently flame retardant in compliance with IEC 60332-1.
DIMENSIONAL & MECHANICAL DATA
Nominal
cross-
sectional
area
mm
1.5
2.5 4 6
10 16 25 35 50 70
95 120 150 185 240 300 400
*) Standard delivery length: 100 m in coil and >100 m in drum.
ELECTRICAL DATA
Nominal
cross-
sectional
area
mm
1.5
2.5 4 6
10 16 25
35 50 70 95
120 150 185 240 300 400
Core identification : green-and-yellow, blue, black, yellow, red, green, white or brown. Test Voltage : 2500 VAC/ 5 minutes.
Other sizes, core identification and packing lengths are available upon request.
2
conductor max
2
Ω/Km MΩ.Km
0.780
0.554
0.161
0.129
0.106
0.0801
0.0641
0.0486
Maximum diameter
of wire
mm
0.25
0.25
0.30
0.30
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
Resistance at 20 ºC
DC
13.3
7.98
4.95
3.30
1.91
1.21
Insulation
min
10
9 7 6 6 5 4 4
0.386
0.272
0.206
4 3 3 3 3 3 3 3 3
Nominal
Thickness
Overall
diameter
mm
0.7
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
Current Carrying Capacity at 30
In Pipe
10.1
11.2
13.8
15.1
17.9
19.6
21.5
24.6
26.5
29.6
35.6
ºC max
15 20 25 33 45 61
83 103 132 165 197 235
-
-
-
-
-
Approximately
Net WeightInsulation
mm mm m
2.9
3.6
4.1
4.7
6.1
8.0
kg/km
19 31 46 64
110 180 280 367 538 916
1,210 1,525 1,899 2,345 3,066 3,109 3,850
In Air
24 32 42 54 73
98 128 158 197 245 290 345 390 445 525 605 725
Minimum
Bending
Radius
Standard
delivery
Length *)
70 90
100
110 150 210 270 300 360 420 500 540 610 690 740 890 990
Short circuit current of
conductor at 1.0 sec max
kAA
0.17
0.29
0.46
0.69
1.16
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
46.34
1 core
100 100 100 100
100 2000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
500
1
Page 5
NYMHY 300/500 Volt
Nominal
cross-
sectional
DC
conductorm
mm
SNI 04-6629.5/SPLN 42-6-2/IEC 60227-5
FLEXIBLE COPPER CONDUCTOR, PVC INSULATED AND SHEATHED CABLE
Applications:
• Power cord or internal wiring with low mechanical stress for electrical equipments, machineries, luminaires and other portable appliances used in dry indoor premises.
• Permanent exposed wiring in humid environment, installation in tray or under plaster for industrial three phase 380 - 415 VAC or single phase 220 - 240 VAC multipurpose applications, inherently flame retardant in compliance with IEC 60332-1.
DIMENSIONAL & MECHANICAL DATA
Nominal
No of Cores
pcs
2
cross-
sectional
area
mm
0.75
2
2
2
3
1.5
2.5
0.75
3
3
3
4
4
4
4
5
5
5
5
*) Standard delivery length: 100 m in coil and >100 m in drum.
1.5
2.5
0.75
1
1.5
2.5
0.75
1
1.5
2.5
1
1
Maximum Diameter
of Wire
mm
0.20
0.20
0.25
0.25
0.20
0.20
0.25
0.25
0.20
0.20
0.25
0.25
0.20
0.20
0.25
0.25
Nominal Thickness
Insulation
mm
0.6
0.6
0.7
0.8
0.6
0.6
0.7
0.8
0.6
0.6
0.7
0.8
0.6
0.6
0.7
0.8
Outer
Sheath
mm
0.8
0.8
0.8
1.0
0.8
0.8
0.9
1.1
0.8
0.9
1.0
1.1
0.9
0.9
1.1
1.2
Approximately
Overall
Diameter
mm
6.3
6.5
7.5
9.2
6.6
6.9
8.1
10.0
7.3
7.8
9.1
10.9
8.1
8.5
10.1
12.2
Cable
Weight
kg/km
54
61
82
128
64
74
104
161
77
92
130
195
98
112
164
246
2, 3, 4, 5 Cores
Bending
Diameter
mm m
120
120
140
180
120
130
150
190
130
140
170
200
150
150
180
220
Standard
delivery
Length *)
100 or 2000
100 or 2000
100 or 2000
100 or 2000
100 or 2000
100 or 2000
100 or 2000
100 or 2000
100 or 2000
100 or 2000
100 or 2000
100 or 2000
100 or 2000
100 or 2000
100 or 2000
100 or 1000
ELECTRICAL DATA
Nominal
cross-
sectional
area
0.75
1
1.5
2.52.5
Core identification : 2 cores by colours : either light blue, brown or light blue, black; 3 cores by colours : either green-and-yellow, light blue, brown, or light blue, black, brown; 4 cores by colours : either green-and-yellow, light blue, black, brown or light blue, black, brown, black or brown; 5 cores by colours : either green-and-yellow, light blue, black, brown, black or brown, or light blue, black, brown, black or brown, black or brown. Colour of sheath : white colour. Test Voltage : 1500 VAC/ 5 minutes for insulation thickness < 0,6 mm. : 2000 VAC/ 5 minutes for insulation thickness > 0,6 mm.
Other sizes, core identification and packing lengths are available upon request.
Resistance at 20 ºC
DC
conductor
max
Insulation
/Km
26.0
19.5
13.3
7.98
min
M
.Km A
11
10
10
9
Current Carrying Capacity
in air at 30 ºC max
2 cores
9
12
19
25
3 , 4 , 5 cores
4
10
17
22
Short circuit
current of
conductor at 1.0 sec
max
kA
0.10
0.13
0.19
0.32
2
Page 6
NYYHY 450/750 Volt
SNI 04-6629.5/Manufacturing Specification
FLEXIBLE COPPER CONDUCTOR, PVC INSULATED AND SHEATHED CABLE
Applications:
• Power cord or internal wiring with medium mechanical stress for electrical equipments, machineries, luminaires and other portable appliances used in dry indoor premises.
• Permanent exposed wiring in humid environment, installation in tray or under plaster for industrial three phase 380 - 415 VAC or single phase 220 - 240 VAC multipurpose applications, inherently flame retardant in compliance with IEC 60332-1.
DIMENSIONAL & MECHANICAL DATA
Nominal
cross-
sectional
area
mm mm
0.75 1
1.5
2.5 4 6
10 16 25 35 50
*) Standard delivery length: 100 m in coil and >100 m in drum.
Maximum
Diameter
of Wire
mm
0.20
0.20
0.25
0.25
0.30
0.30
0.40
0.40
0.40
0.40
0.40
Nominal Thickness
Insulation
Outer
Sheath
mm
0.6
0.6
0.7
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
0.8
0.8
0.8
1.0
1.0
1.1
1.3
1.8
1.8
1.8
1.8
ELECTRICAL DATA
Nominal
cross-
sectional
area
mm
0.75 1
1.5
2.5 4 6
10 16
25 35 50
Resistance at 20 ºC
DC
conductor
max
/Km M
Insulation min
26.0
19.5
13.3
7.98
o
4.95
3.30
o
1.91
1.21
0.780
0.554
0.386
Current Carrying Capacity
11 10 10
9 7 6 6
5 4
4 4
Approximately
Overall
Cable
Diameter Weight
mm kg/km mm m
6.3
6.5
7.5
9.2
10.2
11.5
14.8
19.8
23.8
25.9
30.8
54
61 82 128 171 228 381 637 944
1,194 1,693
Minimum
Bending
Radius
44 46 52 65 72
80 104 137 167 181 216
Short circuit current of
at 30ºC in AIR max
conductor at 1.0 sec max
6 10 15 20 26 33 45
61 83
103 132
2 Cores
Standard
delivery
Length *)
100 or 2000 100 or 2000 100 or 2000 100 or 2000
2000 2000 1000 1000 1000 1000 1000
kA
0.09
0.12
0.17
0.29
0.46
0.69
1.16
1.84
2.87
4.03
5.75
Core identification : 2 cores by colours : either light blue, brown or light blue, black; 3 cores by colours : either green-and yellow, light blue, brown, or light blue, black, brown; 4 cores by colours : either green-and yellow, light blue, black, brown or light blue, black, brown, black or brown; 5 cores by colours : either green-and yellow, light blue, black, brown, black or brown, or light blue, black, brown, black or brown, black or brown. >5 cores by colours : either green-and-yellow and black with white numbering printing or black with white numbering printing. Colour of sheath : black colours. Test Voltage : 2500 VAC/ 5 minutes.
Other sizes, core identification and packing lengths are available upon request.
3
Page 7
m
NYYHY 450/750 Volt
SNI 04-6629.5/Manufacturing Specification
FLEXIBLE COPPER CONDUCTOR, PVC INSULATED AND SHEATHED CABLE
Applications:
• Power cord or internal wiring with medium mechanical stress for electrical equipments, machineries, luminaires and other portable appliances used in dry indoor/outdoor premises.
• Permanent exposed wiring in humid environment, installation in tray or under plaster for industrial three phase 380 - 415 VAC or single phase 220 - 240 VAC multipurpose applications, inherently flame retardant in compliance with IEC 60332-1.
DIMENSIONAL & MECHANICAL DATA
Nominal
cross-
sectional
area
mm mm mm mm kg/km mm
0.75 1
1.5
2.5 4 6
10 16 25 35 50 70
95 120 150 185 240
*) Standard delivery length: 100 m in coil and >100 m in drum.
Maximum
Diameter
of Wire
mm
0.20
0.20
0.25
0.25
0.30
0.30
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.50
0.50
0.50
Nominal Thickness
Insulation
0.6
0.6
0.7
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
Outer
Sheath
0.8
0.8
0.9
1.1
1.1
1.2
1.4
1.8
1.8
1.8
1.8
1.9
2.0
2.1
2.2
2.4
2.5
Approximately
Overall
Diameter Weight
6.6
6.9
8.1
10.0
11.1
12.4
16.0
20.8
25.4
27.7
32.9
36.8
43.4
47.4
51.7
58.9
66.3
Cable
64
73 104 161 217 293 489 797
1,189 1,526 2,172 2,899 3,865 4,784 5,887 7,280 9,444
Minimum
Bending
Radius
46 48 57 70 78
87 112 146 178 194 230 258 304 332 362 412 464
3 Cores
Standard
delivery
Length *)
100 or 2000 100 or 2000 100 or 2000 100 or 2000
2000 1000 1000 1000 1000 1000 1000 1000 1000
500 500 500 300
ELECTRICAL DATA
Nominal
cross-
sectional
area
mm /Km M
0.75 1
1.5
2.5 4 6
10 16 25 35 50 70
95 120 150 185 240
Resistance at 20 ºC
DC
conductor
max
26.0
19.5
13.3
7.98
o4.95
3.30
o1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801
Insulation min
11 10 10
9 7 6 6 5 4 4 4 3 3 3 3 3 3
Current Carrying Capacity
at 30ºC in AIR
max
6 10 15 20 26 33 45 61 83
103 132 165 197 235 264 297 351
Short circuit current of
conductor at 1.0 sec max
kA
0.09
0.12
0.17
0.29
0.46
0.69
1.16
1.84
2.87
4.03
5.75
8.05
10.92
13.80
17.25
21.27
27.60
4
Page 8
m
NYYHY 450/750 Volt
SNI 04-6629.5/Manufacturing Specification
FLEXIBLE COPPER CONDUCTOR, PVC INSULATED AND SHEATHED CABLE
Applications:
• Power cord or internal wiring with medium mechanical stress for electrical equipments, machineries, luminaires and other portable appliances used in dry indoor/outdoor premises.
• Permanent exposed wiring in humid environment, installation in tray or under plaster for industrial three phase 380 - 415 VAC or single phase 220 - 240 VAC multipurpose applications, inherently flame retardant in compliance with IEC 60332-1.
DIMENSIONAL & MECHANICAL DATA
Nominal
cross-
sectional
area
mm mm
0.75 1
1.5
2.5 4 6
10 16 25 35 50 70
95 120 150 185 240
*) Standard delivery length: 100 m in coil and >100 m in drum.
ELECTRICAL DATA
Nominal
cross-
sectional
area
mm /Km M .Km A kA
0.75 1
1.5
2.5 4 6
10 16 25 35 50 70
95 120 150 185 240
Maximum
Diameter
of Wire
mm
0.20
0.20
0.25
0.25
0.30
0.30
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.50
0.50
0.50
Resistance at 20 ºC
DC
conductor
max
26.0
19.5
13.3
7.98
o4.95
3.30
o1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801
Nominal Thickness
Insulation
0.6
0.6
0.7
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
Insulation min
11 10 10
9 7 6 6 5 4 4 4 3 3 3 3 3 3
Outer
Sheath
mm
0.8
0.9
1.0
1.1
1.2
1.3
1.5
1.8
1.8
1.8
1.8
1.9
2.0
2.1
2.2
2.4
2.5
Current Carrying Capacity
Approximately
Overall
Diameter Weight
mm kg/km mm
7.3
7.8
9.1
10.9
12.3
13.8
17.7
22.9
28.0
30.5
36.6
40.9
48.3
52.8
57.8
65.6
74.0
at 30 ºC in AIR
max
6
10
15 20 26 33 45 61
83 103
132 165 197 235 364 297
351
Cable
77 92 130 195 273 369 616 986
1,478 1,910 2,743
3,675 4,887 6,063 7,502
9,220
12,010
Short circuit current of
conductor at 1.0 sec
Minimum
Bending
Radius
51 54 64 77 86
97 124 160
196
214 256
287 338 370 405
459
518
max
0.46
10.92
13.80
17.25
21.27
27.60
4 Cores
Standard
delivery
Length *)
100 or 2000 100 or 2000
1000
1000 1000 1000 1000 1000 1000 1000 1000
1000
500 500
500 300 300
0.09
0.12
0.17
0.29
0.69
1.15
1.84
2.87
4.03
5.75
8.05
5
Page 9
m
NYYHY 450/750 Volt
SNI 04-6629.5/Manufacturing Specification
Applications:
• Power cord or internal wiring with medium mechanical stress for electrical equipments, machineries, luminaires and other portable appliances used in dry indoor/outdoor premises.
• Permanent exposed wiring in humid environment, installation in tray or under plaster for industrial three phase 380 - 415 VAC or single phase 220 - 240 VAC multipurpose applications, inherently flame retardant in compliance with IEC 60332-1.
*) Standard delivery length: 100 m in coil and >100 m in drum.
ELECTRICAL DATA
FLEXIBLE COPPER CONDUCTOR, PVC INSULATED AND SHEATHED CABLE
DIMENSIONAL & MECHANICAL DATA Control cable
Nominal
cross-
sectional
area
mm mm mm mm kg/km mm
5 x 0.75
5 x 1 5 x 1.5 5 x 2.5
5 x 4
5 x 6
5 x 10
7 x 0.75
7 x 1 7 x 1.5 7 x 2.5
10 x 0.75
10 x 1
10 x 1.5 10 x 2.5
12 x 0.75
12 x 1 12 x 1.5 12 x 2.5
Nominal
cross-
sectional
area
mm /Km M .Km A kA
5 x 0.75
5 x 1.0 5 x 1.5 5 x 2.5
5 x 4 5 x 6
5 x 10 7 x 0.75
7 x 1.0 7 x 1.5 7 x 2.5
10 x 0.75
10 x 1.0 10 x 1.5 10 x 2.5
12 x 0.75
12 x 1.0 12 x 1.5 12 x 2.5
Maximum
Diameter
of Wire
mm
0.20
0.20
0.25
0.25
0.30
0.30
0.40
0.20
0.20
0.25
0.25
0.20
0.20
0.25
0.25
0.20
0.20
0.25
0.25
Resistance at 20 ºC
DC
conductor
max
26.0
19.5
13.3
7.98
o4.95
3.30
o1.91
26.0
19.5
13.3
o7.98
26.0
19.5
13.3
o7.98
26.0
19.5
13.3
o7.98
Nominal Thickness
Insulation Outer Sheath
0.6
0.6
0.7
0.8
0.8
0.8
1.0
0.6
0.6
0.7
0.8
0.6
0.6
0.7
0.8
0.6
0.6
0.7
0.8
Insulation min
11 10 10
9 7 6
6 11 10
9
7 11 10
9
7 11 10
9
7
0.9
0.9
1.1
1.2
1.2
1.4
1.6
1.0
1.0
1.2
1.3
1.1
1.1
1.3
1.5
1.1
1.2
1.3
1.5
Current Carrying Capacity
Approximately
Overall
Diameter Weight
8.1
8.5
10.1
12.2
13.5
15.4
19.7
9.1
9.5
11.3
13.6
11.7
12.2
14.5
17.6
12.0
12.8
14.9
18.1
at 30 ºC in AIR
max
6 10 15 20 26 33 45
6 9
10 16
6 8 9
13
6 8 9 13
Cable
98 112 164 246 334 460 767 125 144 203 314 183 211 305 465 208 247 349 535
Minimum
Bending
Radius
57 59 71 85
95 108 138
63
66
79
94
81
85 106
122
84
89 104 126
Short circuit current of
conductor at 1.0 sec
Standard
delivery
Length *)
2000
2000 2000
1000 1000 1000
500
2000
2000 2000 1000
2000
2000 1000 1000
1000
1000 1000 1000
max
0.09
0.12
0.17
0.29
0.46
0.69
1.16
0.09
0.12
0.17
0.29
0.09
0.12
0.17
0.29
0.09
0.12
0.17
0.29
6
Page 10
Applications:
Power cord or internal wiring with low mechanical stress for electrical equipment, machineries, luminares and other portable appiances used in dry indoor premises. Signal and control cables used for connection in electronic control technology, data transmission for voice frequency. Process control and instrumentation, The screening protects the cable againts external electrical inteference (EMI Protection)
Cu/PVC/TCWB/PVC (LiYCY) 300/500 Volt
Manufacturing Spec. / IEC 60227.7
FLEXIBLE COPPER CONDUCTOR, PVC INSULATED,
BRAIDED WITH TINNED COPPER WIRE SHIELDED AND PVC SHEATHED CABLE
Core identification :
2 Cores by Colours
: Light Blue, Brown
3 Cores by Colours
: Yellow Green and yellow, light blue, brown
4 Cores by Colours
: Yellow Green and yellow, light blue, Black, Brown
5 Cores by Colours
: Yellow Green and yellow, light blue, brown, Black, Gray
Colour of Outer sheath
: Grey Colour. Other size, core identification and packing length are available upon request Note : This only general information. For other specific requirement, please cont
act our marketing
DIMENSIONAL & MECHANICAL DATA 2,3,4,5 Cores
2 0.5 0.20 0.88 0.6 0.8 6.4 71 64 1000
2 0.75 0.20 1.13 0.6 0.8 6.9 83 69 1000
2 1 0.20 1.26 0.6 0.8 7.1 92 71 1000
2 1.5 0.25 1.53 0.7 0.9 8.3 112 83 1000
2 2.5 0.25 2.00 0.8 0.9 9.6 167 96 1000
3 0.5 0.20 0.88 0.6 0.8 6.7 74 67 1000
3 0.75 0.20 1.13 0.6 0.8 7.2 88 72 1000
3 1 0.20 1.26 0.6 0.9 7.7 102 77 1000
3 1.5 0.25 1.53 0.7 0.9 8.7 119 87 1000
3 2.5 0.25 2.00 0.8 1.0 10.4 191 104 1000
4 0.5 0.20 0.88 0.6 0.8 7.3 86 73 1000
4 0.75 0.20 1.13 0.6 0.9 8.0 106 80 1000
4 1 0.20 1.26 0.6 0.9 8.4 120 84 1000
4 1.5 0.25 1.53 0.7 0.
9 9.5 157 95 1000
4 2.5 0.25 2.00 0.8 1.1 11.5 233 115 1000
5 0.5 0.20 0.88 0.6 0.9 8.1 103 81 1000
5 0.75 0.20 1.13 0.6 0.9 8.7 124 87 1000
5 1 0.20 1.26 0.6 1.0 9.3 145 93 1000
5 1.5 0.25 1.53 0.7 1.1 10.7 195 107 1000
5 2.5 0.25 2.00 0.8 1.2 12.9 292 129 1000
Standard
Length
Nominal
Area
Maximum
Diameter
wire
Diameter Insulation
Outer
Sheath
Diameter
Weight of
Cable
Number of
Core
Conductor Thickness Approximately
Bending
Radius
ELECTRICAL DATA
mm2 Ω/Km
0.5 39.0 13 4
0.75 26.0 11 6
1 19.5 10 10
1.5 13.3 10 15
2.5 7.98 9 20
mΩ/Km
DC conductor max
Resistance at 20
o
C
Current Carrying Capacity
in air at 30
o
C max
A kA
0.05
0.08
0.10
0.16
0.26
Nominal
cross-
sectional
area
Short circuit current of
conductor at 1.0 sec max
Insulation min
7
Page 11
Cu/PVC/TCWB/PVC (LiYCY) 300/500 Volt
DIMENSIONAL & MECHANICAL DATA Control Cable
ELECTRICAL DATA
area
Manufaturing Spec. / IEC 60227.7
FLEXIBLE COPPER CONDUCTOR, PVC INSULATED,
BRAIDED WITH TINNED COPPER WIRE SHIELDED AND PVC SHEATHED CABLE
Applications:
Power cord or internal wiring with low mechanical stress for electrical equipment, machineries, luminares and other portable appiances used in dry indoor premises. Signal and control cables used for connection in electronic control technology, data transmission for voice frequency. Process control and instrumentation, The screening protects the cable againts external electrical inteference (EMI Protection)
Conductor Thickness Approximately
Number of
Core
10 0.5 0.20 0.88 0.6 1.1 11.2 184 112 1000
10 0.75 0.20 1.13 0.6 1.2 12.3 230 123 1000
10 1 0.20 1.26 0.6 1.2 12.9 262 129 1000
10 1.5 0.25 1.53 0.7 1.4 15.2 372 152 1000
10 2.5 0.25 2.00 0.8 1.5 18.1 540 181 1000
Nominal
Area
6 0.5 0.20 0.88 0.6 0.9 8.7 119 87 1000
6 0.75 0.20 1.13 0.6 1.0 9.6 148 96 1000
6 1 0.20 1.26 0.6 1.0 10.0 167 100 1000
6 1.5 0.25 1.53 0.7 1.1 11.6 226 116 1000
6 2.5 0.25 2.00 0.8 1.3 14.1 343 141 1000
7 0.5 0.20 0.88 0.6 0.9 8.7 125 87 1000
7 0.75 0.20 1.13 0.6 1.0 9.6 155 96 1000
7 1 0.20 1.26 0.6 1.0 10.0 176 100 1000
7 1.5 0.25 1.53 0.7 1.1 11.7 246 117 1000
7 2.5 0.25 2.00 0.8 1.3 14.1 366 141 1000
8 0.5 0.20 0.88 0.6 1.0 9.5 144 95 1000
8 0.75 0.20 1.13 0.6 1.0 10.3 180 103 1000
8 1 0.20 1.26 0.6 1.1 11.0 211 110 1
8 1.5 0.25 1.53 0.7 1.2 12.8 289 128 1000
8 2.5 0.25 2.00 0.8 1.4 15.4 427 154 1000
Maximum
Diameter
wire
Diameter Insulation
Outer
Sheath
Diameter
Weight of
Cable
Bending
Radius
Standard
Length
000
Nominal
cross-
sectional
mm2 Ω/Km
6x0.5 39.0 13
6x0.75 26.0 11
6x1 19.5 10
6x1.5 13.3 10
6x2.5 7.98 9
7x0.5 39.0 13
7x0.75 26.0 11
7x1 19.5 10
7x1.5 13.3 10
7x2.5 7.98 9
8x0.5 39.0 13
8x0.75 26.0 11
8x1 19.5 10
8x1.5 13.3 10
8x2.5 7.98 9
10x0.5 39.0 13
10x0.75 26.0 11
10x1 19.5 10
10x1.5 13.3 10
10x2.5 7.98 9
Other size, core identification and packing length are available upon request Note : This only general information. For other specific requirement, please contact our marketing
DC conductor max Insulation min
Resistance at 20 oC
Current Carrying Capacity
in air at 30
mΩ/Km A kA
o
C max
3
5
9
14
19
3
5
9
14
19
3
5
8
12
16
3
4
7
11
15
Short circuit current of
conductor at 1.0 sec max
0.05
0.08
0.10
0.16
0.26
0.05
0.08
0.10
0.16
0.26
0.05
0.08
0.10
0.16
0.26
0.05
0.08
0.10
0.16
0.26
8
Page 12
Cu/PVC/TCWB/PVC (LiYCY) 300/500 Volt
Nominal
area
Manufaturing Spec. / IEC 60227.7
FLEXIBLE COPPER CONDUCTOR, PVC INSULATED,
BRAIDED WITH TINNED COPPER WIRE SHIELDED AND PVC SHEATHED CABLE
Applications:
Power cord or internal wiring with low mechanical stress for electrical equipment, machineries, luminares and other portable appiances used in dry indoor premises. Signal and control cables used for connection in electronic control technology, data transmission for voice frequency. Process control and instrumentation, The screening protects the cable againts external electrical inteference (EMI Protection)
Conductor Thickness Approximately
Number of
Core
12 0.5 0.20 0.88 0.6 1.1 11.6 216 116 1000
12 0.75 0.20 1.13 0.6 1.2 12.8 269 128 1000
12 1 0.20 1.26 0.6 1.2 13.3 308 133 1000
12 1.5 0.25 1.53 0.7 1.4 15.7 417 157 1000
12 2.5 0.25 2.00 0.8 1.6 18.9 614 189 1000
14 0.5 0.20 0.88 0.6 1.2 12.3 234 123 1000
14 0.75 0.20 1.13 0.6 1.2 13.4 287 134 1000
14 1 0.20 1.26 0.6 1.3 14.2 335 142 1000
14 1.5 0.25 1.53 0.7 1.4 16.4 457 164 1000
14 2.5 0.25 2.00 0.8 1.7 20.0 688 200 1000
15 0.5 0.20 0.88 0.6 1.2 12.9 253 129 1000
15 0.75 0.20 1.13 0.6 1.3 14.3 317 143 1000
15 1 0.
15 1.5 0.25 1.53 0.7 1.5 17.5 501 175 1000
15 2.5 0.25 2.00 0.8 1.7 21.1 745 211 1000
16 0.5 0.20 0.88 0.6 1.2 12.9 263 129 1000
16 0.75 0.20 1.13 0.6 1.3 14.3 330 143 1000
16 1 0.20 1.26 0.6 1.3 14.9 376 149 1000
16 1.5 0.25 1.53 0.7 1.5 17.5 519 175 1000
16 2.5 0.25 2.00 0.8 1.7 21.1 770 211 1000
Nominal
Area
Maximum
Diameter
wire
Diameter Insulation
20 1.26 0.6 1.3 14.9 362 149 1000
Outer
Sheath
Diamet
er
Weight of
Cable
Bending
Radius
Standard
Length
ELECTRICAL DATA
cross-
sectional
mm2 Ω/Km
12x0.5 39.0 13
12x0.75 26.0 11
12x1 19.5 10
12x1.5 13.3 10
12x2.5 7.98 9
14x0.5 39.0 13
14x0.75 26.0 11
14x1 19.5 10
14x1.5 13.3 10
14x2.5 7.98 9
15x0.5 39.0 13
15x0.75 26.0 11
15x1 19.5 10
15x1.5 13.3 10
15x2.5 7.98 9
16x0.5 39.0 13
16x0.75 26.0 11
16x1 19.5 10
16x1.5 13.3 10
16x2.5 7.98 9
DC conductor max Insulation min
Resistance at 20 oC
Current Carrying Capacity
in air at 30
mΩ/Km A kA
o
C max
3
4
7
11
15
3
4
7
10
14
3
4
7
10
14
3
4
7
10
13
Short circuit current of
conductor at 1.0 sec max
0.05
0.08
0.10
0.16
0.26
0.05
0.08
0.10
0.16
0.26
0.05
0.08
0.10
0.16
0.26
0.05
0.08
0.10
0.16
0.26
Other size, core identification and packing length are available upon request Note : This only general information. For other specific requirement, please contact our marketing
9
Page 13
Cu/PVC/TCWB/PVC (LiYCY) 300/500 Volt
DIMENSIONAL & MECHANICAL DATA Control Cable
19 2.5 0.25 2.00 0.8 1.8 22.3 876 223 1000
21 2.5 0.25 2.00 0.8 2.1 25.1 1.016 251 1000
24 2.5 0.25 2.00 0.8 2.1 26.5 1.136 265 1000
27 2.5 0.25 2.00 0.8 2.1 27.2 1267 272 1000
ELECTRICAL DATA
Nominal
Manufaturing Spec. / IEC 60227.7
FLEXIBLE COPPER CONDUCTOR, PVC INSULATED,
BRAIDED WITH TINNED COPPER WIRE SHIELDED AND PVC SHEATHED CABLE
Applications:
Power cord or internal wiring with low mechanical stress for electrical equipment, machineries, luminares and other portable appiances used in dry indoor premises. Signal and control cables used for connection in electronic control technology, data transmission for voice frequency. Process control and instrumentation, The screening protects the cable againts external electrical inteference (EMI Protection)
Conductor Thickness Approximately
Number of
Core
19 0.5 0.20 0.88 0.6 1.3 13.7 293 137 1000 19 0.75 0.20 1.13 0.6 1.3 15.0 362 150 1000 19 1 0.20 1.26 0.6 1.4 15.8 424 158 1000 19 1.5 0.25 1.53 0.7 1.6 18.6 587 186 1000
21 0.5 0.20 0.88 0.6 1.4 15.2 335 152 1000 21 0.75 0.20 1.13 0.6 1.5 16.8 432 168 1000 21 1 0.20 1.26 0.6 1.6 17.7 489 177 1000 21 1.5 0.25 1.53 0.7 1.8 20.7 675 207 1000
24 0.5 0.20 0.88 0.6 1.4 16.0 376 160 1000 24 0.75 0.20 1.13 0.6 1.6 17.9 475 179 1000 24 1 0.20 1.26 0.6 1.6 18.7 550 187 1000 24 1.5 0.25 1.53 0.7 1.8 21.9 755 219 1000
Nominal
Area
Maximum
Diameter
wire
Diameter Insulation
Outer
Sheath
Diameter
Weight of
Cable
Bending
Radius
Standard
Length
27 0.5 0.20 0.88 0.6 1.4 16.3 401 163 1000 27 0.75 0.20 1.13 0.6 1.5 18.0 505 180 1000 27 1 0.20 1.26 0.6 1.6 19.1 591 191 1000 27 1.5 0.25 1.53 0.7 1.8 22.3 822 223 1000
cross-
sectional
mm2 Ω/Km
19x0.5 39.0 13 2.5 0.05
19x0.75 26.0 11 4 0.08
19x1 19.5 10 6 0.10
19x1.5 13.3 10 9 0.16
19x2.5 7.98 9
21x0.5 39.0 13 2.5 0.05
21x0.75 26.0 11 4 0.08
21x1 19.5 10 6 0.10
21x1.5 13.3 10 8 0.16
21x2.5 7.98 9
24x0.5 39.0 13 2.5 0.05
24x0.75 26.0 11 4 0.08
24x1 19.5 10 6 0.10
24x1.5 13.3 10 8 0.16
24x2.5 7.98 9
27x0.5 39.0 13 2.5 0.05
27x0.75 26.0 11 4 0.08
27x1 19.5 10 6 0.10
27x1.5 13.3 10 8 0.16
27x2.5 7.98 9
DC conductor max Insulation min
Resistance at 20 oC
mΩ/Km A kA
Current Carrying Capacity
in air at 30
o
C max
13
12
12
12
Short circuit current of
conductor at 1.0 sec max
0.26
0.26
0.26
0.26
Other size, core identification and packing length are available upon request Note : This only general information. For other specific requirement, please contact our marketing
10
Page 14
---
---
---
--
--
---
--
---
--
---
---
--
---
---
--
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
--
CONVERSION TABLE
mm
11
Nominal cross sectional area
Inc
2
2
Circular
Mils
( CM ) CSA
SWG
Equivalent
Metric
= British Standard Wire Gauge
Wire gauge
AWG BWG SWG
Nominal cross sectional area
Circular
2
mm2Inc
0.0005 644 0.325 22 -- 0.0290 36,874 18.68 --6
0.0006 487 0.397 -2222 0.0324 41,217 20.88 -6-
0.0006 821 0.416 21 -- 0.0326 41,750 21.15 4--
0.50 0.0008 987 ---- 0.0353 44,948 22.77 --5
0.0008 1,021 0.517 20 -- 0.0380 48,402 24.52 -5-
0.0008 1,025 0.519 -212125 0.0388 49,350 -
0.0009 1,198 0.607 -20- 0.0413 52,627 26.66 3--
0.0010 1,289 0.653 19 -- 0.0423 53,831 27.27 --4
0.0010 1,297 0.657 --20 0.0445 56,654 28.70 -4 -
0.0013 1,601 0.811 --19 0.0499 63,523 32.18 --3
0.75 0.0012 1,481 ---- 0.0521 66,386 33.63 2--
0.0013 1,625 0.823 18 -- 0.0527 67,096 33.99 -3-
0.0014 1,765 0.894 -19- 35 0.0543 69,090 -
1.0 0.0016 1,974 ---- 0.0598 76,196 28.60 --2
0.0016 2,053 1.040 17 -- 0.0633 80,677 40.87 -2-
0.0016 2,304 1.167 --18 0.0657 83,717 42.41 1--
0.0019 2,402 1.217 -18- 0.0707 90,014 45.60 -11
0.0020 2,584 1.309 16 -- 50 0.0775 98,700 -
1.5 0.0023 2,961 ---- 0.0824 404,997 53.19 --1/0
0.0025 3,137 1.589 --17 0.0829 105,589 53.49 1/0
0.0026 3,257 1.650 15 -- 0.0908 115,637 58.58 - 1/0 -
0.0026 3,366 1.705 -17- 0.0951 121,125 61.36 --2/0
0.0032 4,096 2.075 --16 0.1045 133,087 67.42 2/0
0.0032 4,108 2.081 14 -- 70 0.1085 138,180 -
0.0033 4,226 2.141 -16- 0.1087 138,417 70.12 --3/0
2.5 0.0039 4,935 ---- 0.1134 144,438 73.17 - 2/0 -
0.0040 5,180 2.624 13 -- 0.1257 160,032 81.07 --4/0
0.0040 5,186 2.627 -1515 0.1318 167,849 85.03 3/0
0.0050 6,402 3.243 --14 0.1419 180,660 91.52 - 3/0 -
0.0051 6,532 3.309 12 -- 0.1466 186,661 94.56 --5/0
0.0054 6,891 3.491 -14- 95 0.1473 187,530 -
4 0.0062 7,896 ---- 0.1616 206,086 104.40 - 4/0 -
0.0065 8,236 4.172 11 -- 0.1691 211,613 107.20 4/0
0.0066 8,466 4.269 --13 0.1860 215,363 109.10 --6/0
0.0071 9,072 4.573 -13- 120 0.1860 236,880 -
0.0082 10,387 5.262 10 -- 0.1963 249,987 126.64
0.0085 10,819 5.481 --12 0.1964 250,106 126.70 - 5/0 7/0
0.0093 11,883 6.020 -12- 0.2091 266,332 134.92 5/0
6 0.0093 11,844 ---- 150 0.2325 296,100 -
0.0103 13,092 6.632 9-- 0.2356 300,048 152.00
0.0106 13,459 6.816 --11 0.2642 336,488 170.46 6/0
0.0113 14,404 7.297 -11- 185 0.2868 365,190 -
0.0129 16,388 8.302 --10 0.3142 400,150 202.71
0.0130 16,518 8.368 8-- 240 0.3720 473,760 -
0.0141 17,959 9.098 -10- 0.3927 500,113 253.35
10 0.0155 19,740 ---- 300 0.4650 592,200 -
0.0163 20,766 10.520 --9 0.4712 600,096 304.00
0.0164 20,826 10.550 7-- 0.5498 700,198 354.71
0.0172 21,911 11.100 -9- 400 0.6200 789,600 -
0.0201 25,603 12.970 --8 0.6283 800,161 405.35
0.0206 26,254 13.300 6-- 500 0.7750 987,000
0.0214 27,241 13.800 -8- 0.7854 1,000,246 506.71
0.0243 30,992 15.700 --7 625 0.9688 1,233,750 -
16 0.0248 31,584 ---- 630 0.9765 1,243,620 -
0.0255 32,413 16.420 -7- 800 1.2400 1,597,200 -
0.0260 33,104 16.770 5-- 1,000 1.5500 1,974,000 -
Note :
AWG
Mils
( CM ) CSA
= American Wire Gauge
Equivalent
Metric
Wire gauge
AWG BWG SWG
BWG
= Birmingham Wire Gauge
Page 15
Page 16