Sub-Zero & Wolf 15 Gas, 30 Professional Gas, 30 Transitional Gas, 36 Transitional Gas, 36 Professional Gas Quick Start Manual

Gas Cooktops Installation Guide
GAS COOKTOPS
Contents
3 Gas Cooktops
4 Specications
7 Installation
7 Troubleshooting
Features and specications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information.
Important Note
To ensure this product is installed and operated as safely and efciently as possible, take note of the following types of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION indicates a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specied.
IMPORTANT NOTE: Save these instructions for the local
electrical inspector.
2 | Wolf Customer Care 800.222.7820
GAS COOKTOPS
Product Information
Important product information including the model and serial number are listed on the product rating plate. The rating plate is located on the bottom of the cooktop. Refer to the illustration below.
If service is necessary, contact Wolf factory certied service with the model and serial number. For the name of the nearest Wolf factory certied service or for questions regarding the installation, visit the contact & support section of our website, wolfappliance.com or call Wolf customer care at 800-222-7820.
Installation Requirements
If a cooktop is installed above an oven, a minimum of 1/4" (6) is required between units. A minimum 5 from the bottom of the cooktop to combustible materials.
1
/2" (140) is required
Electrical
Installation must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.
Locate the electrical supply as shown in the illustrations on pages 5–6. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz Service 15 amp dedicated circuit Receptacle 3-prong grounding-type Power Cord 6'
(1.8 m)
RATING PLATE
Rating plate location.
wolfappliance.com | 3
SPECIFICATIONS
Gas Supply
Installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code.
Locate the gas supply as shown in the illustrations on pages 5–6.
The cooktop is equipped for use with natural or liquid propane (LP) gas. It is design certied by the Canadian Standards Association (CSA) for natural or LP gases. The product rating plate has information on the type of gas that should be used. For rating plate location, refer to the illustra­tion below. If this information does not agree with the type of gas available, check with the local gas supplier. The gas pressure regulator is built into the unit.
GAS SUPPLY REQUIREMENTS
NATURAL GAS
Gas Supply Pressure 5" (12.5 mb) WC Min Line Pressure 7" Max Pressure to Regulator 14"
LP GAS
Gas Supply Pressure 10" (25 mb) WC Min Line Pressure 11" (27.4 mb) WC Max Pressure to Regulator 14"
(34.9 mb) WC, .5 psi (3.5 kPa)
(34.9 mb) WC, .5 psi (3.5 kPa)
(17.5 mb) WC
The cooktop must be connected to a regulated gas supply. The supply line must be equipped with an approved external gas shut-off valve located near the cooktop in an accessible location. Do not block access to the shut-off valve. Refer to the illustration below.
3
A gas supply line of the cooktop. If local codes permit, a certied, 3'
1
/2" (13) or 3/4" (19) ID exible metal appliance connector is
recommended to connect the units
/4" (19) rigid pipe must be provided to
(.9 m) long,
1
/2" NPT male inlet to the gas supply line. Pipe joint compounds, suitable for use with natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of .5 psi
(3.5 kPa)
. The appliance must be isolated from the gas supply piping system by closing its individual manual shut­off valve during any pressure testing of the system at test pressures equal to or less than .5 psi
Wolf natural gas cooktops will function up to 10,250'
(3124 m)
will function up to 8,600'
in altitude without adjustment and LP gas cooktops
(2621 m). If the installation exceeds
(3.5 kPa).
these elevations, contact your authorized Wolf dealer for a high altitude conversion kit.
RATING PLATE
Rating plate location.
4 | Wolf Customer Care 800.222.7820
SHUT-OFF VALVE
OPEN POSITION
Gas shut-off valve.
GAS SUPPLYTO APPLIANCE
SPECIFICATIONS
15" Gas Cooktop
STANDARD INSTALLATION
21/2" (64)
13"
(330)
18"
(457)
14"
(356)
COUNTERTOP CUT-OUT
30"
(762)
7"
(178)
E G
191/2"
(495)
21/2" (64)
ELECTRICAL
AND GAS FLOOR
5"
(127)
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
LOCATION
FRONT VIEWSIDE VIEW
wolfappliance.com | 5
SPECIFICATIONS
SIDE
NO combus El
30" and 36" Gas Cooktop
STANDARD INSTALLATION
21/2" (64)
13"
(330)
18"
(457)
9"
(229)
W
WIDTH
COUNTERTOP CUT-OUT
30"
(762)
4" (102)
31/2" (89)
E G
10"
(254)
191/2"
(495)
21/2"
(64)
VIEW
TE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
ectrical and gas supply location only applies to installations with built-in oven.
CUT-OUT WIDTH
MODEL W
30" Cooktop 29" (737) 36" Cooktop 35" (889)
6 | Wolf Customer Care 800.222.7820
FRONT VIEW