Sub-Zero & Wolf 30 Gas Range (R30 - Open Burner), 36 Gas Range (R36 - Open Burner), 48 Gas Range (R48 - Open Burner), 60 Gas Range (R60 - Open Burner) Quick Start Manual

INSTALLATION GUIDE
Gas Ranges
Contents
Important Note
Wolf Gas Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Gas Range Specifications . . . . . . . . . . . . . . . . . . . . . . 5
Gas Range Installation . . . . . . . . . . . . . . . . . . . . . . . . 14
Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Features and specifications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information.
IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified.
o ensure the safe and efficient use of Wolf equipment,
T please take note of the following types of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially important.
CAUTION signals a situation where minor injury or product damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or death if precautions are not followed.
Wolf Gas Ranges 3
wolfappliance.com/specs
Gas Range Installation
IMPORTANT NOTE: T
his installation must be completed
by a qualified installer, service agency or gas supplier.
Read this entire installation guide prior to installation and save for the local inspector’s reference. The homeowner should keep this installation guide for future reference.
This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedi­cated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and amperage ratings are listed on the product rating plate.
Wolf gas ranges are manufactured for use with natural gas or LP gas. Check the product rating plate for the type of gas for your specific model. If this appliance does not correspond to your type of gas, contact your authorized Wolf dealer.
Record the model and serial numbers before installing the gas range. Both numbers are listed on the product rating plate, located under the drip pan that supports the cooking grates, inside the left side panel of the range. Refer to the illustration below.
olf Gas Range
W
Model Number
Serial Number
RATING PLATE
Location of rating plate (inside panel).
Safety Instructions 4
IMPORTANT INSTRUCTIONS
WHAT TO DO IF YOU SMELL GAS:
If the information in this guide is not followed exactly, a fire or explosion may result, causing property damage, personal injury or death.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Warranty service must be performed by a Wolf authorized service center.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
A ventilation hood is recommended for use with the Wolf gas range.
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
This range can tip. Injury to persons could result. Install the anti-tip device provided with this range according to instructions on page 14.
In Massachusetts: Installations and repairs must be performed by a qualified or licensed contractor, plumber or gasfitter qualified or licensed by the state, province, or region where this appliance is being installed. Only use gas shut-off valves approved for use within the state, province, or region where this appliance is being installed. A flexible gas connector, when used, must not exceed 3' (.9 m).
Gas Range Specifications 5
30" (762)
3
7"
(940)
HEIGHT TO
COOKING SURFACE
36" (914)
3
7"
(940)
HEIGHT TO
COOKING SURFACE
48" (
1219)
3
7"
(
940)
H
EIGHT TO COOKING SURFACE
60" (1524)
36" (914)
37" (940)
HEIGHT TO
COOKING SURFACE
21/2"
(64)
241/2" (622)
251/4" (641)
LEGS AND CASTERS ALLOW 1" (25) HEIGHT ADJUSTMENT
433/8" (1102)
463/4"
(1187)
10"
RISER
563/4"
(1441)
20"
RISER
271/4" (692)
91/4"
(235)
283/8" (721)
413/4"
(1060)
5"
RISER
wolfappliance.com/specs
Gas Ranges
30" (762) RANGE
60" (1527) RANGE
36" (914) RANGE 48" (1219) RANGE
SIDE VIEW—ALL RANGES
Gas Range Specifications 6
AIR INTAKES
HEATED AIR EXITS
Installation Requirements
VENTILATION
Failure to locate the range without the proper clear­ances will result in a fire hazard.
IMPORTANT NOTE: Caution must be used in planning the
proper installation of the Wolf gas range to avoid fires or damage to adjacent cabinetry or kitchen equipment. Follow all minimum clearances to combustible surfaces shown in the installation illustration for your specific model on the following pages.
IMPORTANT NOTE: A minimum 5" (127) riser is required
when installing a gas range against a combustible surface. A minimum 10" (254) riser is required when installing a gas range with a charbroiler or griddle against a combustible surface.
Risers and other accessories are available through your authorized Wolf dealer. To obtain local dealer information, visit the find a showroom section of our website, wolfappliance.com.
The gas range must have an adequate supply of fresh air to assure proper combustion and ventilation. The location of the range should be away from strong draft areas, such as windows, doors and strong heating vents or fans. Do not obstruct the flow of air.
For the cooking surface, fresh air intakes are located below the bullnose and control knobs. For the oven, there are fresh air intakes at the bottom front of the kick panel. Never block the fresh air intakes. Most of the heated air and burner combustion by-products from the oven(s) exit through the back riser. Refer to the illustration below.
Due to the high volume of ventilation air required, a source of outside replacement air is recommended. This is espe­cially important for tightly sealed and insulated homes. A qualified HVAC contractor should be consulted.
It is recommended that you use a Wolf pro ventilation hood or hood liner with the Wolf gas range. Refer to the Wolf ventilation guide.
Air intakes and exits.
Loading...