Sub-Zero & Wolf 30 Built-In Double Oven - E Series - Contemporary, 30 Built-In Double Oven - E Series - Professional, 30 Built-In Double Oven - E Series - Transitional, E Series, 30 Built-In Oven - E Series (Earlier Models) Quick Start Manual

...
E Series Ovens Installation Guide
E SERIES OVENS
Contents
3 E Series Ovens
4 Specications
10 Installation
11 Troubleshooting
Features and specications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information.
Important Note
To ensure this product is installed and operated as safely and efciently as possible, take note of the following types of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION indicates a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specied.
IMPORTANT NOTE: Save these instructions for the local
electrical inspector.
2 | Wolf Customer Care 800.222.7820
E SERIES OVENS
Product Information
Important product information including the model and serial number are listed on the product rating plate. The rating plate is located below the control panel. The oven door must be open to view the rating plate. Refer to the illustration below.
If service is necessary, contact Wolf factory certied service with the model and serial number. For the name of the nearest Wolf factory certied service or for questions regarding the installation, visit the contact & support section of our website, wolfappliance.com or call Wolf customer care at 800-222-7820.
Rating plate location.
RATING
PLATE
wolfappliance.com | 3
SPECIFICATIONS
Installation Requirements
The oven can be installed in a standard or ush inset application. Location of the electrical supply within the oven opening may require additional cabinet depth. Refer to the chart below.
Finish the edges of the opening. They may be visible when the door is open.
1
For ush inset installations, a minimum required on all sides. To ensure consistent
/4" (6) reveal is
1
/4" (6) reveals,
each corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT
Single Oven 250 lb (115 kg) Double Oven 400 lb (181 kg)
CABINET DEPTH
Standard Installation 24" (610) min Flush Inset Installation 25" (635) min Flush Inset (contemporary model) 251/4" (641) min
TRIM (STANDARD INSTALLATION)
Top Overlap Bottom Overlap Side Overlap
5
/8" (16)
1
/8" (3)
3
/4" (19)
COMBINATION INSTALLATIONS
Wolf built-in ovens are designed and agency approved for installation with Wolf cooktops, microwaves and warming drawers only. The nominal width of the oven should match the nominal width of the cooktop. A built-in oven cannot be installed below a Wolf rangetop.
For typical combination installations, refer to the Wolf Design Guide.
The single oven may be installed next to another E series
1
single oven. You must allow for a 1
/2" (38) space between oven openings. A separate inner wall is required for each oven between openings.
4 | Wolf Customer Care 800.222.7820
SPECIFICATIONS
Electrical
Installation must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.
Locate the electrical supply ush with the back wall and within the shaded area shown in the illustration for your specic installation on the following pages. For ease of installation, the electrical supply for the oven can be placed in an adjacent cabinet within reach of the conduit. Use only the conduit supplied with this appliance.
Performance may be compromised if the electrical supply is less than 240 volts.
The wiring diagram covering the control circuit is provided with the oven.
ELECTRICAL REQUIREMENTS
SINGLE OVEN
Electrical Supply grounded, 240/208 VAC, 60 Hz Service 30 amp dedicated circuit Total Amps 21 Max Connected Load 5.1 kW Min Supply Wire L1, L2, ground—10 AWG
DOUBLE OVEN
Electrical Supply grounded, 240/208 VAC, 60 Hz Service 50 amp dedicated circuit Total Amps 37 Max Connected Load 8.9 kW Min Supply Wire L1, L2, ground—10 AWG
WARNING
The complete appliance must be properly grounded at all times when electrical power is applied.
Grounding through the neutral conductor is prohibited for new branch-circuit installations (1996 NEC); mobile homes and recreational vehicles, or where local codes prohibit grounding through the neutral conductor.
If aluminum house supply wiring is utilized, splice the appliance copper wire to the aluminum house wiring using special connectors design and agency certied for joining copper and aluminum. Follow the connector manufacturer's recommended procedure carefully. Improper connection can result in a re hazard.
Rating plate location.
RATING
PLATE
wolfappliance.com | 5
SPECIFICATIONS
E Series Single Oven
STANDARD INSTALLATION
TOP VIEW
24" (610)
OPENING
DEPTH
271/4"
(692)
OPENING
HEIGHT
43/4" (121)
TYPICAL
NOTE: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit
.
281/2" (724)
OPENING WIDTH
FRONT VIEWSIDE VIEW
5"
(127)
E
4"
(102)
E
6 | Wolf Customer Care 800.222.7820
SPECIFICATIONS
E Series Double Oven
STANDARD INSTALLATION
TOP VIEW
24" (610)
OPENING
DEPTH
E
493/4"
(1264)
OPENING
HEIGHT
17" (432)
TYPICAL
NOTE: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit
.
281/2" (724)
OPENING WIDTH
FRONT VIEWSIDE VIEW
5"
(127)
4"
(102)
E
E
E
wolfappliance.com | 7
SPECIFICATIONS
E Series Single Oven
FLUSH INSET INSTALLATION
283/8"
(721)
FLUSH INSET
HEIGHT
1" (25)
OR
11/4" (32)**
TOP VIEW
303/8" (772)
FLUSH INSET WIDTH
3
/4"(19)
15
/16" (24)
3
/8" (10)
25" (635)
FLUSH INSET
DEPTH
(102)
5"
(127)
FINISHED
CLEATS*
4"
E
E
E
*Shaded areas will be visible and should be finished to match cabinetry. **1"
(25) for professional and transitional models and 1
NOTE: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit
.
1
/4" (32) for contemporary model.
8 | Wolf Customer Care 800.222.7820
FRONT VIEWSIDE VIEW
SPECIFICATIONS
E Series Double Oven
FLUSH INSET INSTALLATION
507/8"
(1292)
FLUSH INSET
HEIGHT
17" (432)
TYPICAL
1" (25)
OR
11/4" (32)**
TOP VIEW
303/8" (772)
FLUSH INSET WIDTH
3
/4"(19)
15
/16" (24)
3
/8" (10)
25" (635)
FLUSH INSET
DEPTH
(102)
5"
(127)
FINISHED
CLEATS*
4"
E
E
E
*Shaded areas will be visible and should be finished to match cabinetry.
(25) for professional and transitional models and 1
**1"
NOTE: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit
.
1
/4" (32) for contemporary model.
FRONT VIEWSIDE VIEW
wolfappliance.com | 9
INSTALLATION
Preparation
Before moving the oven, protect any nished ooring and secure oven door(s) closed to prevent damage.
Use an appliance dolly to move the unit near the opening. Remove and recycle packing materials. Do not lift or carry the oven by the door handle.
CAUTION
Do not lift oven by the door handle. This will damage the oven door and hinges.
OVEN DOOR REMOVAL
To lighten the load or to t through a door way, the oven door(s) can be removed. Only remove if necessary. Door removal should only be done by a certied installer or service technician.
To remove, open the door completely. Rotate both hinge latches forward to the open position, then lift door up and out. Refer to the illustration below.
To reinstall, insert door hinges into frame openings, then rotate hinge latches to the closed position.
Electrical Connection
WARNING
Verify that power is disconnected from the electrical box before proceeding.
With the oven positioned directly in front of the opening, feed the conduit through the opening in the cabinet platform (if applicable). Depending on local codes, connect the oven to the electrical supply following these steps for a three-wire or four-wire system:
1 Connect the black appliance wire to the black (L1) power
supply wire in the electrical box.
2 Connect the red appliance wire to the red (L2) power
supply wire in the electrical box.
3 Connect the ground appliance wire to the green/ground
house grounding wire in the electrical box.
4 For a four-wire system, leave the white neutral wire in the
house electrical box unconnected. Seal with a wire cap.
CLOSED
OPEN
Oven door removal.
10 | Wolf Customer Care 800.222.7820
Loading...
+ 22 hidden pages