WOLF WARMING DRAWER
INSTALLATION REQUIREMENTS
IMPORTANT NOTE:
This installation must be
completed by a qualified installer or Wolf
uthorized service center technician.
a
nstaller:Please read the entire Installation
I
Instructions prior to installation. Save these instructions for the local inspector’s refer-
nce, then leave them with the homeowner.
e
Homeowner:
Please read and keep these instructions for future reference and be sure to read the entire Use & Care Information prior to use.
Any questions or problems about the installation should be directed to your Wolf dealer or Wolf Appliance Company, LLC at 800-332-9513. You can also visit our website at wolfappliance.com.
IMPORTANT NOTE:
This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and amperage ratings are listed on the product rating plate.
Record the model and serial numbers before installing the warming drawer. Both numbers
re listed on the product rating plate, located
a on the left front floor area of the inner cabinet. To access the rating plate, the drawer must be
ully open. Refer to the illustration below.
f
Model Number WWD30
Serial Number
OUTDOOR APPLICATION
The Wolf warming drawer is designed and safe for use in outdoor applications. When installed outdoors, a ground fault circuit interrupter (GFCI) is required to reduce the risk of electri­cal shock. All other aspects of the installation are identical for indoor and outdoor use.
Model WWD30
with Stainless Steel
Drawer Front
Model WWD30
with Integrated
Drawer Front
Location of rating plate
Rating plate location
3
WOLF WARMING DRAWER
ACCESSORIES
Optional acces­sories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com.
BEFORE YOU START
Proper installation is the responsibility of the installer. Product failure due to
mproper installation is not covered under
i the Wolf warranty. Refer to the Warming Drawer Use & Care Information for
arranty details.
w
efore you install the warming drawer,
B make sure you have the Wolf accessory drawer front called for in your installation.
IMPORTANT NOTE:
If you are installing the warming drawer with integrated drawer front in an inset panel application, make sure that your cabinetry meets the minimum 33" (838) width and 25" (635) depth requirement for this installation.
Check with local utilities for electrical codes that apply in your area. Local codes vary. Installation, electrical connections and grounding must comply with applicable codes. In the absence of local codes, the drawer should be installed in accordance with National Electrical Code ANSI/NFPA 70-1990 or latest edition.
This appliance must be properly grounded. Refer to Electrical Requirements on page 12.
Make sure you have the tools and materials necessary for proper installation.
Warranty service must be performed by a Wolf authorized service center. Wolf is not
equired to cor
esponsible for ser
r
vice r
faulty installation.
ect a
r
DRAWER FRONT OPTIONS
IMPORTANT NOTE:
Model WWD30 must be
installed with a Wolf stainless steel or
ntegrated drawer front.
i
lassic Stainless Steel
C Platinum Stainless Steel Carbon Stainless Steel Integrated Drawer Front
WDFRONT/S
W WWDFRONT/P WWDFRONT/B WWDFRONT/I
(accepts wood panel)
Drawer fronts are ordered and shipped as sales accessories and include additional installation instructions. Stainless steel drawer fronts include a matching tubular handle.
The integrated drawer front accepts a custom wood panel and handle to be provided by the homeowner. Optional stainless steel tubular handles in classic, platinum and carbon stain­less finishes are available as sales accessories.
TOOLS AND MATERIALS REQUIRED
Wood screws or other hardware to install the solid platform or runners that support the warming drawer
2" (51) x 2" (51) or 2" (51) x 4" (102) lumber for runners—runners must be able to support 200 lbs (91 kg)
2" (51) x 2" (51) or 2" (51) x 4" (102) lumber for anti-tip block
Power saw Level
1
Drill and drawer fr
/16" bit, 1/2" bit also for integrated
ont application
Dimensions in parentheses are in millimeters unless otherwise specified.4
Phillips screwdriver 2 wood screws (provided)
ood cleats for integrated drawer fr
W application
ont
INSTALLATION INSTRUCTIONS
285/8" (727)
OPENING WIDTH
E
5"
(127)
4"
(102)
33" (838)
RECOMMENDED CABINET WIDTH
30" min (762)
36" (914)
STANDARD
FLOOR TO COUNTER
HEIGHT
5" min (127)
BOTTOM
OF OPENING
TO FLOOR
24" min (610)
CABINET DEPTH
91/8" (232)
OPENING
HEIGHT
237/8" min (606)
OPENING DEPTH
2"(51) x 2"(51)
ANTI-TIP BLOCK
DIMENSION WILL VARY*
ALLOW FOR
5
/8" (16)
OVERLAP OF
DRAWER FACE
ON ALL SIDES
*Allow enough room for placement of anti-tip block and drawer face overlap.
231/2" (597)
BEHIND FRAME
297/8" (759)
OVERALL WIDTH
9"
(229)
271/8" (689)
OVERALL DEPTH
101/4"
(260)
STAINLESS STEEL DRAWER FRONT
INSTALLATION SPECIFICATIONS
he following illustrations provide the overall
T dimensions and installation specifications for the Wolf warming drawer with a stainless steel
rawer front.
d Wolf recommends using a 33" (838) wide
cabinet for the warming drawer with stainless steel drawer front. A minimum 30" (762) wide by 24" (610) deep cabinet is required with a minimum base support of 200 lbs (91 kg).
Refer to pages 14–15 for stainless steel drawer front installation instructions. These instruc­tions are also included with the stainless steel drawer front kit.
UNDERCOUNTER INSTALLATION
For undercounter installations, 231/2" (597) from the bottom of the warming drawer opening to the floor is recommended. It must be installed a minimum of 5" (127) above the floor or 1" (25) above the toe kick.
The Wolf warming drawer with stainless steel drawer front may be installed below an electric or gas cooktop, provided the warming drawer is fully enclosed, top and bottom. Allow enough room for gas and electrical connec­tions for the cooktop. Refer to installation instructions for the cooktop for additional specifications. Dimensions will vary according to the specific installation.
MODEL WWD30
with Stainless Steel Drawer Front
Overall Width 297/8" (759) Overall Height 101/4" (260) Overall Depth 271/8" (689) Depth Behind Frame* 231/2" (597) Minimum Cabinet Width 30" (762) Minimum Cabinet Depth 24" (610) Minimum Base Support 200 lbs (91 kg) Opening Width 285/8" (727) Opening Height 91/8" (232) Opening Depth 237/8" (606)
*Allow 3/8" (10) additional depth for cord thickness.
Overall Dimensions – Stainless Steel Drawer Fr
ont
Undercounter Installation – Stainless Steel Drawer Front
5
WOLF WARMING DRAWER
281/2" (724)
33" (838)
RECOMMENDED CABINET WIDTH
30"min (762)
285/8" (727)
WARMING DRAWER
OPENING WIDTH
E
5"
(127)
4"
(102)
ALLOW FOR
5
/8" (16)
OVERLAP OF
DRAWER FACE
ON ALL SIDES
NOTE: Refer to the built-in 30" (762) single oven specifications for electrical location.
30-INCH OVEN
ROUGH OPENING
24"min (610)
CABINET DEPTH
23/8"
(60)
ANTI-TIP BLOCK APPLICATION
91/8" (232)
OPENING
HEIGHT
237/8"min (606)
OPENING DEPTH
273/16"
(691)
24"min
(610)
2"(51) x 2"(51)
ANTI-TIP BLOCK
PLATFORM APPLICATION
24"min (610)
CABINET DEPTH
7
/8"
(22)
91/8" (232)
OPENING
HEIGHT
237/8"min (606)
OPENING DEPTH
273/16"
(691)
24"min
(610)
7
/8" (22)
PLATFORM
STAINLESS STEEL DRAWER FRONT
INSTALLATION WITH BUILT-IN OVEN
he Wolf warming drawer with stainless steel
T drawer front may be installed below or above a Wolf 30" (762) built-in single oven or below a
ouble oven, provided the warming drawer is
d fully enclosed, top and bottom. Refer to the illustration below. Also refer to installation instructions provided with the built-in oven for additional specifications. Dimensions will vary according to the specific installation.
The Wolf warming drawer is designed and agency approved for installation with Wolf built-in ovens.
The warming drawer platform must be able to support 200 lbs (91 kg). It must be a minimum of 1" (25) above the toe kick to allow for the overlap of the warming drawer trim.
IMPORTANT NOTE:
Additional clearance
between warming drawer and oven openings
ay be required. Check that oven supports do
m not obstruct the interior dimensions required for the warming drawer.
When the warming drawer is installed below
built-in oven, a minimum of 2
a
3
(60)
/8" between warming drawer and oven openings is required for placement of the anti-tip block. To allow the warming drawer trim and the built-in oven trim to meet, a
7
/8" (22) platform may be used to separate the two openings. This will act as the support platform for the oven and the anti-tip device for the warming drawer. Both applications are shown in the illustration below.
IMPORTANT NOTE:
When the warming
drawer is installed above a built-in oven, a
7
/8" (22) platform is required to allow for
clearance of overlaps.