As you follow these instructions, you will
notice WARNING and CAUTION symbols.
This blocked information is important for the
safe and efficient installation of Wolf equipment. There are two types of potential
hazards that may occur during installation.
WOLF®is a registered trademark of Wolf Appliance Company, LLC
signals a situation where minor injury or
product damage may occur if you do not
follow instr
states a hazard that may cause serious
injury or death if precautions are not
followed.
Another footnote we would like to identify is
IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation.
uctions.
WOLF WARMING DRAWER
INSTALLATION REQUIREMENTS
IMPORTANT NOTE:
This installation must be
completed by a qualified installer or Wolf
uthorized service center technician.
a
nstaller:Please read the entire Installation
I
Instructions prior to installation. Save these
instructions for the local inspector’s refer-
nce, then leave them with the homeowner.
e
Homeowner:
Please read and keep these
instructions for future reference and be sure
to read the entire Use & Care Information
prior to use.
Any questions or problems about the
installation should be directed to your Wolf
dealer or Wolf Appliance Company, LLC at
800-332-9513. You can also visit our website
at wolfappliance.com.
IMPORTANT NOTE:
This appliance must be
installed in accordance with National Electrical
Codes, as well as all state, municipal and local
codes. The correct voltage, frequency and
amperage must be supplied to the appliance
from a dedicated, grounded circuit which is
protected by a properly sized circuit breaker or
time delay fuse. The proper voltage, frequency,
and amperage ratings are listed on the product
rating plate.
Record the model and serial numbers before
installing the warming drawer. Both numbers
re listed on the product rating plate, located
a
on the left front floor area of the inner cabinet.
To access the rating plate, the drawer must be
ully open. Refer to the illustration below.
f
Model Number WWD30
Serial Number
OUTDOOR APPLICATION
The Wolf warming drawer is designed and safe
for use in outdoor applications. When installed
outdoors, a ground fault circuit interrupter
(GFCI) is required to reduce the risk of electrical shock. All other aspects of the installation
are identical for indoor and outdoor use.
Model WWD30
with Stainless Steel
Drawer Front
Model WWD30
with Integrated
Drawer Front
Location of
rating plate
Rating plate location
3
WOLF WARMING DRAWER
ACCESSORIES
Optional accessories are available
through your
Wolf dealer. To
obtain local dealer
information, visit
the Locator section
of our website,
wolfappliance.com.
BEFORE YOU START
Proper installation is the responsibility of
the installer. Product failure due to
mproper installation is not covered under
i
the Wolf warranty. Refer to the Warming
Drawer Use & Care Information for
arranty details.
w
efore you install the warming drawer,
B
make sure you have the Wolf accessory
drawer front called for in your installation.
IMPORTANT NOTE:
If you are installing
the warming drawer with integrated drawer
front in an inset panel application, make
sure that your cabinetry meets the
minimum 33" (838) width and 25" (635)
depth requirement for this installation.
Check with local utilities for electrical codes
that apply in your area. Local codes vary.
Installation, electrical connections and
grounding must comply with applicable
codes. In the absence of local codes, the
drawer should be installed in accordance
with National Electrical Code ANSI/NFPA
70-1990 or latest edition.
This appliance must be properly grounded.
Refer to Electrical Requirements on
page 12.
Make sure you have the tools and materials
necessary for proper installation.
Warranty service must be performed by a
Wolf authorized service center. Wolf is not
equired to cor
esponsible for ser
r
vice r
faulty installation.
ect a
r
DRAWER FRONT OPTIONS
IMPORTANT NOTE:
Model WWD30 must be
installed with a Wolf stainless steel or
ntegrated drawer front.
i
lassic Stainless Steel
C
Platinum Stainless Steel
Carbon Stainless Steel
Integrated Drawer Front
WDFRONT/S
W
WWDFRONT/P
WWDFRONT/B
WWDFRONT/I
(accepts wood panel)
Drawer fronts are ordered and shipped as
sales accessories and include additional
installation instructions. Stainless steel drawer
fronts include a matching tubular handle.
The integrated drawer front accepts a custom
wood panel and handle to be provided by the
homeowner. Optional stainless steel tubular
handles in classic, platinum and carbon stainless finishes are available as sales accessories.
TOOLS AND MATERIALS REQUIRED
Wood screws or other hardware to install
the solid platform or runners that support
the warming drawer
2" (51) x 2" (51) or 2" (51) x 4" (102) lumber
for runners—runners must be able to
support 200 lbs (91 kg)
2" (51) x 2" (51) or 2" (51) x 4" (102) lumber
for anti-tip block
Power saw
Level
1
Drill and
drawer fr
/16" bit, 1/2" bit also for integrated
ont application
Dimensions in parentheses are in
millimeters unless otherwise specified.4
Phillips screwdriver
2 wood screws (provided)
ood cleats for integrated drawer fr
W
application
ont
INSTALLATION INSTRUCTIONS
285/8" (727)
OPENING WIDTH
E
5"
(127)
4"
(102)
33" (838)
RECOMMENDED CABINET WIDTH
30" min (762)
36" (914)
STANDARD
FLOOR TO
COUNTER
HEIGHT
5" min (127)
BOTTOM
OF OPENING
TO FLOOR
24" min (610)
CABINET DEPTH
91/8" (232)
OPENING
HEIGHT
237/8" min (606)
OPENING DEPTH
2"(51) x 2"(51)
ANTI-TIP BLOCK
DIMENSION
WILL VARY*
ALLOW FOR
5
/8" (16)
OVERLAP OF
DRAWER FACE
ON ALL SIDES
*Allow enough room for placement of anti-tip block and drawer face overlap.
231/2" (597)
BEHIND FRAME
297/8" (759)
OVERALL WIDTH
9"
(229)
271/8" (689)
OVERALL DEPTH
101/4"
(260)
STAINLESS STEEL DRAWER FRONT
INSTALLATION SPECIFICATIONS
he following illustrations provide the overall
T
dimensions and installation specifications for
the Wolf warming drawer with a stainless steel
rawer front.
d
Wolf recommends using a 33" (838) wide
cabinet for the warming drawer with stainless
steel drawer front. A minimum 30" (762) wide
by 24" (610) deep cabinet is required with a
minimum base support of 200 lbs (91 kg).
Refer to pages 14–15 for stainless steel drawer
front installation instructions. These instructions are also included with the stainless steel
drawer front kit.
UNDERCOUNTER INSTALLATION
For undercounter installations, 231/2" (597)
from the bottom of the warming drawer
opening to the floor is recommended. It must
be installed a minimum of 5" (127) above the
floor or 1" (25) above the toe kick.
The Wolf warming drawer with stainless steel
drawer front may be installed below an electric
or gas cooktop, provided the warming drawer
is fully enclosed, top and bottom. Allow
enough room for gas and electrical connections for the cooktop. Refer to installation
instructions for the cooktop for additional
specifications. Dimensions will vary according
to the specific installation.
*Allow 3/8" (10) additional depth for cord thickness.
Overall Dimensions – Stainless Steel Drawer Fr
ont
Undercounter Installation – Stainless Steel Drawer Front
5
WOLF WARMING DRAWER
281/2" (724)
33" (838)
RECOMMENDED CABINET WIDTH
30"min (762)
285/8" (727)
WARMING DRAWER
OPENING WIDTH
E
5"
(127)
4"
(102)
ALLOW FOR
5
/8" (16)
OVERLAP OF
DRAWER FACE
ON ALL SIDES
NOTE: Refer to the built-in 30" (762) single oven specifications for electrical location.
30-INCH OVEN
ROUGH OPENING
24"min (610)
CABINET DEPTH
23/8"
(60)
ANTI-TIP BLOCK APPLICATION
91/8" (232)
OPENING
HEIGHT
237/8"min (606)
OPENING DEPTH
273/16"
(691)
24"min
(610)
2"(51) x 2"(51)
ANTI-TIP BLOCK
PLATFORM APPLICATION
24"min (610)
CABINET DEPTH
7
/8"
(22)
91/8" (232)
OPENING
HEIGHT
237/8"min (606)
OPENING DEPTH
273/16"
(691)
24"min
(610)
7
/8" (22)
PLATFORM
STAINLESS STEEL DRAWER FRONT
INSTALLATION WITH BUILT-IN OVEN
he Wolf warming drawer with stainless steel
T
drawer front may be installed below or above
a Wolf 30" (762) built-in single oven or below a
ouble oven, provided the warming drawer is
d
fully enclosed, top and bottom. Refer to the
illustration below. Also refer to installation
instructions provided with the built-in oven for
additional specifications. Dimensions will vary
according to the specific installation.
The Wolf warming drawer is designed and
agency approved for installation with Wolf
built-in ovens.
The warming drawer platform must be able to
support 200 lbs (91 kg). It must be a minimum
of 1" (25) above the toe kick to allow for the
overlap of the warming drawer trim.
IMPORTANT NOTE:
Additional clearance
between warming drawer and oven openings
ay be required. Check that oven supports do
m
not obstruct the interior dimensions required
for the warming drawer.
When the warming drawer is installed below
built-in oven, a minimum of 2
a
3
(60)
/8"
between warming drawer and oven openings
is required for placement of the anti-tip block.
To allow the warming drawer trim and the
built-in oven trim to meet, a
7
/8" (22) platform
may be used to separate the two openings.
This will act as the support platform for the
oven and the anti-tip device for the warming
drawer. Both applications are shown in the
illustration below.
IMPORTANT NOTE:
When the warming
drawer is installed above a built-in oven, a
7
/8" (22) platform is required to allow for
clearance of overlaps.
Installation with Built-In Oven – Stainless Steel Drawer Front
6
INSTALLATION INSTRUCTIONS
285/8" (727)
WARMING DRAWER
OPENING WIDTH
281/2" (724)
30-INCH OVEN
OPENING WIDTH
5"
(127)
4"
(102)
E
E
MICROWAVE
ROUGH OPENING
33" (838)
RECOMMENDED CABINET WIDTH
30"min (762)
23/8"
(60)
273/16"
(691)
1"min
(25)
24"min
(610)
273/16"
(691)
NOTE: Refer to the built-in 30" (762) single oven specifications for electrical location.
2"(51) x 2"(51)
ANTI-TIP BLOCK
91/8" (232)
OPENING
HEIGHT
237/8"min (606)
OPENING DEPTH
1"min
(25)
24"min
(610)
91/8" (232)
OPENING
HEIGHT
237/8"min (606)
OPENING DEPTH
ANTI-TIP BLOCK APPLICATIONPLATFORM APPLICATION
7
/8" (22)
PLATFORM
7
/8"
(22)
91/8"
(232)
103/4"
(273)
1
0
1
/4"
(
260)
WARMING DRAWER
ROUGH OPENING
3
/4" (19) THICK WALL OVEN
SUPPORT PLATFORM
OVEN TRIM EXTENDS
1
/8" (
3)
B
ELOW OVEN PLATFORM
OVEN ROUGH OPENING
S
IDE VIEW
FRONT
2" x 2"
ANTI-TIP
BLOCK
FACE RAIL
5
/8"
(
16)
235/8" (600)
15/8"
(41)
REVEAL
23/8"
(60)
5
/8"
(16)
STAINLESS STEEL DRAWER FRONT
OPTIONAL INSTALLATIONS
he Wolf warming drawer with stainless steel
T
drawer front may be installed in combination
with a 30" (762) single oven and microwave
ven with 30" (762) trim, provided the
o
warming drawer is fully enclosed, top and
bottom. Refer to the illustration below. Also
refer to installation instructions provided with
the built-in oven and microwave for additional
specifications. Dimensions will vary according
to the specific installation.
The warming drawer platform must be able to
support 200 lbs (91 kg). It must be a minimum
of 1" (25) above the toe kick to allow for the
overlap of the warming drawer trim.
Installation with Built-In Oven – Stainless Steel
Drawer Front
The Wolf warming drawer with stainless steel
drawer front may be installed next to or above
another Wolf warming drawer, provided each
unit is fully enclosed, top and bottom.
Installation with Built-In Oven and Microwave – Stainless Steel Drawer Front
Dimensions in parentheses are in
millimeters unless otherwise specified.
7
WOLF WARMING DRAWER
291/2" (749)
OPENING WIDTH
E
5"
(127)
4"
(102)
33" (838)
RECOMMENDED CABINET WIDTH
30" min (762)
36" (914)
STANDARD
FLOOR TO
COUNTER
HEIGHT
5" min (127)
BOTTOM
OF OPENING
TO FLOOR
24" min (610)
CABINET DEPTH
24" min (610)
OPENING DEPTH
ALLOW FOR
OVERLAP OF
DECORATIVE
DRAWER FACE
ON ALL SIDES**
DIMENSION
WILL VARY*
*Allow enough room for placement of anti-tip block and drawer face overlap.
**Overlap of decorative drawer face will vary depending on the size of the custom panel.
101/4"
(260)
OPENING
HEIGHT
97/8"(251)
2"(51) x 2"(51)
ANTI-TIP BLOCK
293/8" (746)
OVERALL WIDTH
231/2" (597)
BEHIND FRAME
9"
(229)
101/8"
(257)
INTEGRATED DRAWER FRONT
INSTALLATION SPECIFICATIONS
he following illustrations provide the overall
T
dimensions and installation specifications for
the Wolf warming drawer with integrated
rawer front. The warming drawer with inte-
d
grated drawer front can be used in an overlay
application or an inset panel application where
it will be completely recessed in to the cabinet.
Keep in mind that the size of the custom panel
for the warming drawer with integrated drawer
front will vary according to the specific installation. The following chart provides minimum
dimensions for the overlay and inset panel
applications.
Refer to pages 16–18 for integrated drawer
front installation instructions. These instructions are also included with the integrated
drawer front kit.
Overlay33" (838) W x 24" (610) D
Inset33" (838) W x 25" (635) D
Minimum Base Support200 lbs (91 kg)
Opening Width291/2" (749)
Opening Height101/4" (260)
Opening Depth**24" (610)
Minimum Panel Size
Overlay30" (762) W x 10
3
/8" (264) H
Inset293/8" (746) W x 101/8" (257) H
Minimum Panel Thickness
5
/8" (16)
Maximum Panel Weight25 lbs (11 kg)
*Allow 3/8" (10) additional depth for cord thickness.
**For the inset application, add the thickness of
the drawer face to the opening depth.
8
Overall Dimensions – Integrated Drawer Front
Integrated Drawer Front – Overlay Application
25" min (635)
CABINET DEPTH
291/2" (749)
OPENING WIDTH
E
5"
(127)
4"
(102)
33" (838)
MINIMUM CABINET WIDTH
36" (914)
STANDARD
FLOOR TO
COUNTER
HEIGHT
5" min (127)
BOTTOM
OF OPENING
TO FLOOR
*Allow enough room for placement of anti-tip block.
24" (610) + THICKNESS
OF DRAWER FACE
FOR OPENING DEPTH
DIMENSION
WILL VARY*
101/4"
(260)
OPENING
HEIGHT
97/8"(251)
2"(51) x 2"(51)
ANTI-TIP BLOCK
INSTALLATION INSTRUCTIONS
INTEGRATED DRAWER FRONT
OVERLAY APPLICATION
A minimum 33" (838) wide by 24" (610) deep
cabinet is required for the warming drawer
ith integrated drawer front using the overlay
w
application. A minimum base support of 200
lbs (91 kg) is required. Refer to the illustration
n page 8.
o
INSET APPLICATION
IMPORTANT NOTE:
The inset application
requires the warming drawer to be recessed
into the cabinet. A minimum 25" (635) deep
cabinet is needed if you want the front panel
to be flush with surrounding cabinetry.
If you are installing the warming drawer with
integrated drawer front in an inset application,
a minimum 33" (838) wide and 25" (635) deep
cabinet is required for this installation. A
minimum base support of 200 lbs (91 kg) is
required. Refer to the illustration below.
UNDERCOUNTER INSTALLATION
For undercounter installations, 231/2" (597)
from the bottom of the warming drawer
pening to the floor is recommended. It must
o
be installed a minimum of 5" (127) above the
floor or 1" (25) above the toe kick.
The Wolf warming drawer with integrated
drawer front may be installed below a 30"
(762) or 36" (914) wide electric or gas cooktop,
provided the warming drawer is fully enclosed,
top and bottom. Refer to installation instructions for the cooktop for additional specifications. Dimensions will vary according to the
specific installation.
Integrated Drawer Front – Inset Application
Dimensions in parentheses are in
millimeters unless otherwise specified.
9
WOLF WARMING DRAWER
NOTE: Refer to the built-in 30" (762) single oven specifications for electrical location.
INSET APPLICAT IONOVERLAY APPLICATI ON
273/16"
(691)
24"min
(610)
24" min (610)
OPENING DEPTH
24" min (610)
CABINET DEPTH
273/16"
(691)
24"min
(610)
24" (610) + THICKNESS
OF DRAWER FACE
FOR OPENING DEPTH
25" min (635)
CABINET DEPTH
291/2" (749)
WARMING DRAWER
OPENING WIDTH
281/2" (724)
30-INCH OVEN
OPENING WIDTH
33" (838)
CABINET WIDTH
E
5"
(127)
4"
(102)
11/2"min*
(38)
11/2"min*
(38)
101/4"
(260)
OPENING
HEIGHT
97/8"(251)
2"(51) x 2"(51)
ANTI-TIP BLOCK
101/4"
(260)
OPENING
HEIGHT
97/8"(251)
2"(51) x 2"(51)
ANTI-TIP BLOCK
*Dimension may increase depending on the size of the drawer front panel.
INTEGRATED DRAWER FRONT
INSTALLATION WITH BUILT-IN OVEN
he Wolf warming drawer with integrated
T
drawer front may be installed below or above
a Wolf 30" (762) or 36" (914) built-in single
ven, provided the warming drawer is fully
o
enclosed, top and bottom. Refer to the
illustration below. Also refer to installation
instructions provided with the built-in oven for
additional specifications. Dimensions will vary
according to the specific installation.
The Wolf warming drawer is designed and
agency approved for installation with Wolf
built-in ovens.
The warming drawer platform must be able to
support 200 lbs (91 kg). It must be a minimum
of 1" (25) above the toe kick to allow for the
overlap of the warming drawer trim.
IMPORTANT NOTE:
Additional clearance
between warming drawer and oven openings
ay be required. Check that oven supports do
m
not obstruct the interior dimensions required
for the warming drawer.
When the warming drawer is installed below
built-in oven, a minimum of 1
a
1
(38)
/2"
between warming drawer and oven openings
is required for placement of the anti-tip block
and oven platform. When installed above a
built-in oven, a minimum of
7
/8" (22) is
required.
IMPORTANT NOTE:
In an overlay application,
the amount of space between warming drawer
and built-in oven openings may need to be
increased depending on the size of the overlay
panel and the amount of overlap.
Installation with Built-In Oven – Integrated Drawer Front
10
INSTALLATION INSTRUCTIONS
291/2" (749)
WARMING DRAWER
OPENING WIDTH
281/2" (724)
30-INCH OVEN
OPENING WIDTH
E
33" (838)
CABINET WIDTH
11/2"min*
(38)
273/16"
(691)
1"min
(25)
24"min
(610)
MICROWAVE
ROUGH OPENING
24" min (610)
OPENING DEPTH
NOTE: Refer to the built-in 30" (762) single oven specifications for electrical location.
INSET APPLICAT IONOVERLAY APPLICATI ON
*Dimension may increase depending on the size of the drawer front panel.
E
5"
(127)
4"
(102)
24" min (610)
CABINET DEPTH
11/2"min*
(38)
273/16"
(691)
1"min
(25)
24"min
(610)
24" (610) + THICKNESS
OF DRAWER FACE
FOR OPENING DEPTH
25" min (635)
CABINET DEPTH
101/4"
(260)
OPENING
HEIGHT
97/8"(251)
2"(51) x 2"(51)
ANTI-TIP BLOCK
101/4"
(260)
OPENING
HEIGHT
97/8"(251)
2"(51) x 2"(51)
ANTI-TIP BLOCK
INTEGRATED DRAWER FRONT
INSTALLATION OPTIONS
he Wolf warming drawer with integrated
T
drawer front may be installed in combination
with a 30" (762) single built-in oven and
icrowave with 30" (762) trim, provided the
m
warming drawer is fully enclosed, top and
bottom. Refer to the illustration below.
The Wolf warming drawer with integrated
drawer front may also be installed in combination with a 36" (914) single built-in oven and
microwave with 36" (914) trim.
The warming drawer platform must be able to
support 200 lbs (91 kg). It must be a minimum
of 1" (25) above the toe kick to allow for the
overlap of the warming drawer trim.
Refer to installation instructions provided with
the built-in oven and microwave for additional
pecifications. Dimensions will vary according
s
to the specific installation.
The Wolf warming drawer with integrated
drawer front may be installed next to or above
nother Wolf warming drawer, provided each
a
unit is fully enclosed, top and bottom.
Installation with 30" (762) Built-In Oven and Microwave – Integrated Drawer Front
Dimensions in parentheses are in
millimeters unless otherwise specified.
11
WOLF WARMING DRAWER
ELECTRICAL REQUIREMENTS
IMPORTANT
NOTE
You must follow
all National
Electrical Code
regulations. In
addition, be aware
of local codes and
ordinances when
installing your
service.
The Wolf warming drawer requires a separate,
grounded 120 V AC, 50/60 Hz power supply
nd must be connected to an individual
a
properly grounded branch circuit and
protected by a 15 or 20 amp circuit breaker or
ime delay fuse.
t
MPORTANT NOTE: The warming drawer is
I
equipped with a power supply cord with a
3-prong grounding plug, which must be
plugged into a mating 3-prong grounding-type
electrical outlet to minimize the possibility of
electric shock.
The location of the outlet is not critical, but
must be within reach of the 6' (1.8 m) power
cord. If it is placed behind the unit, make sure
the outlet is flush with the back wall. For
location of the electrical outlet, refer to the
installation illustration for your specific
installation on pages 5–11.
The electrical outlet can be located in an
adjacent cabinet within reach of the power
cord. If the outlet is located in an adjacent
cabinet, you will need to drill a 2" (51)
diameter hole in the cabinet wall for the power
cord.
IMPORTANT NOTE:
When installed outdoors,
A ground fault circuit interrupter (GFCI) is
equired to reduce the risk of electrical shock.
r
ou must follow all National Electrical Code
Y
regulations. In addition, be aware of local
codes and ordinances when installing your
ervice.
s
The electrical outlet must be checked by
a qualified electrician to be sure that it is
wired with the correct polarity. Verify
that the outlet provides 120 V AC and is
properly grounded.
Do not use an extension cord or twoprong adapter. Electrical ground is
required on this appliance. Do not remove
the power supply cord ground prong.
If two warming drawers are installed side by
side, they can operate from the same electrical
outlet. A 30 amp circuit breaker is required for
this installation.
12
INSTALLATION INSTRUCTIONS
CABINET SUPPORTS
IMPORTANT NOTE:
When the warming
drawer is installed with a built-in oven,
dditional clearance between openings may be
a
required. Check that oven supports do not
obstruct the interior dimensions required for
he warming drawer.
t
he warming drawer with stainless steel
T
drawer front may be supported by either a
solid platform, 2" (51) x 2" (51) runners or 2"
(51) x 4" (102) runners. The platform or runners
must be level, rigidly mounted and flush with
the bottom edge of the opening. They must be
able to support 200 lbs (91 kg).
If an integrated drawer front is used, it must be
supported by a
5
/8" (16) solid platform. The
platform will need to be recessed and allow for
overlap of the warming drawer collar. Refer to
page 16 for additional details. The platform
must be level, rigidly mounted and must be
able to support 200 lbs (91 kg).
IMPORTANT NOTE:
Make sure that the
platform or runners are level. There is no way
to level the warming drawer once it has been
installed.
UNPACK THE WARMING DRAWER
Unpack the warming drawer on a flat surface.
Remove all packaging materials and tape from
nside the warming drawer and discard. Do not
i
discard the package containing the two wood
screws needed for installation.
Dimensions in parentheses are in
millimeters unless otherwise specified.
13
WOLF WARMING DRAWER
Collar
Location of
mounting holes
STAINLESS STEEL FRONT PANEL
INSTALL ANTI-TIP BLOCKING
An anti-tip block or platform must be
installed to prevent the warming drawer
from tipping forward while opened when
l
oaded. Failure to do so could result in
personal injury and damage to the
cabinet.
Install a 2" (51) x 2" (51) or 2" (51) x 4" (102)
anti-tip block against the rear cabinet wall.
When the warming drawer is installed below a
7
built-in oven, you may use a
/8" (22) thick
platform to allow the warming drawer trim and
the oven trim to meet. The platform will act as
an anti-tip device for the warming drawer. Both
applications are shown in the illustrations on
page 6.
INSTALL WARMING DRAWER TRIM
emove all packaging materials from the trim.
R
The stainless steel drawer front kit comes with
two long trim pieces for the top and bottom
ollar of the warming drawer and two short
c
trim pieces for the sides. Each trim piece has a
groove that fits over the edge of the collar.
Refer to the illustration below.
Place one of the long trim pieces on the top
collar of the warming drawer so the groove in
the trim fits on the top collar.
Next, place one of the small side trim pieces
on the left collar edge. The top trim and side
trim should nest together. On the backside of
the trim pieces are mounting holes. Use the
5
small
/16" (8) long screws provided in the kit to
secure these two pieces together.
Repeat this process to attach the right side and
bottom trim.
14
Install warming drawer trim
INSTALLATION INSTRUCTIONS
Location of
side hole
Drawer Front
Assembly
Front
Panel Lip
STAINLESS STEEL FRONT PANEL
INSTALL FRONT PANEL
emove all packaging materials from the
R
handle and front panel. Gently remove the
protective covering from the stainless steel
ront panel. The adhesive covering should peel
f
away from the surface cleanly, but any remaining residue should be cleaned off with a mild
detergent.
To attach the handle to the front panel, line up
holes in the standoffs and handle with holes
on the front panel. Insert handle screws
through the holes in the front panel and
tighten screws to the front panel.
Slide the top lip of the front panel over the
drawer front. Insert three screws in the top of
the front panel lip through the drawer front
assembly and tighten screws. Insert three
screws in the bottom of the front panel
through the drawer front assembly and tighten
screws. Refer to the illustration below.
Turn power off to the electrical outlet.
INSTALL WARMING DRAWER
Slide the left corner of the warming drawer
into the opening. If the electrical outlet is
nstalled inside the opening, plug the power
i
cord into the outlet. The excess cord should be
coiled behind or beside the unit. If the outlet
s located in an adjacent cabinet, thread the
i
power cord through the hole in the cabinet
wall. Push the drawer back into the opening
until the trim meets the cabinet front. Make
sure the power cord does not get trapped
under the warming drawer.
IMPORTANT NOTE:
Do not lift up on the
handle to push the drawer into place. Doing so
could scratch the control panel.
Open the warming drawer to its full extension.
Drill pilot holes in each side hole, located
toward the front on each side of the warming
drawer. Install the wood screws provided with
the unit. Refer to the illustration below.
Turn power back on to the electrical outlet.
Dimensions in parentheses are in
millimeters unless otherwise specified.
Warming drawer installationAttach handle
15
WOLF WARMING DRAWER
Platform
Top Cleat
Side Cleat
Cabinetry
Opening
Cleats and platform
recessed 3/16" (5)
plus thickness
of decorative panel
Platform
Top Cleat
Side Cleat
Cabinetry
Opening
Cleats and platform
recessed 3/16" (5)
INTEGRATED FRONT PANEL
INSTALL CLEATS AND PLATFORM
For an overlay or inset application, you will
need to install a recessed platform and cleats
f the following dimensions into the opening.
o
Top Cleat Dimensions
1
29
/2" (749) W x 1/2" (13) H x 2" (51) D
Side Cleat Dimensions
1
/2" (13) W x 91/8" (232) H x 2" (51) D
Platform Dimensions
1
29
/2" (749) W x 5/8" (16) H x 233/4" (603) D
Depth of platform may increase depending
cabinet depth.
For an overlay application, the platform and
3
cleats will need to be recessed
inset application, they must be recessed
/16" (5). For an
3
/16"
(5) plus the thickness of the decorative drawer
panel, allowing the decorative panel to be
flush with the front of the cabinet. Be sure to
rigidly mount the platform so that it can
support a minimum of 200 lbs (91 kg). Refer to
the illustrations below.
IMPORTANT NOTE:
be sure to recess the cleats no more than
In an overlay application,
3
/16"
(5). Recessing deeper than this may cause the
drawer to not close properly.
IMPORTANT NOTE:
Be sure to finish the
inside lip of the opening and the front face of
he shelf and cleats. Some of these areas will
t
be visible when the drawer is open.
IMPORTANT NOTE:
Be aware of the location
of the mounting holes on the warming drawer
rame to make sure the screws used to attach
f
the cleats do not interfere with the screw holes
for mounting the warming drawer.
16
Recessed cleats and platform –
overlay application
Recessed cleats and platform –
inset application
INSTALLATION INSTRUCTIONS
Location of
side hole
INTEGRATED FRONT PANEL
INSTALL ANTI-TIP BLOCKING
Install a 2" (51) x 2" (51) or 2" (51) x 4" (102)
anti-tip block against the rear cabinet wall as
hown in the installation illustration for your
s
specific installation on pages 9–11.
INSTALL WARMING DRAWER
Turn power off to the electrical outlet. Slide the
left corner of the warming drawer into the
pening. If the electrical outlet is installed
o
inside the opening, plug the power cord into
the outlet. The excess cord should be coiled
ehind or beside the unit. If the outlet is
b
located in an adjacent cabinet, thread the
power cord through the hole in the cabinet
wall. Push the unit back into the opening until
the warming drawer collar meets up with the
recessed cleats and platform. Make sure the
power cord does not get trapped under the
warming drawer.
Open the drawer to its full extension. Drill pilot
holes in each side hole, one located toward
the front on each side of the warming drawer.
Install the wood screws provided with the
warming drawer. Refer to the illustration
below. Turn power back on to the electrical
outlet.
ming drawer installation
ar
W
Dimensions in parentheses are in
millimeters unless otherwise specified.
17
WOLF WARMING DRAWER
Rubber Bumper
Decorative
Panel
Screw
Metal
Panel
INTEGRATED FRONT PANEL
INSTALL FRONT PANEL TO DRAWER
emove the front panel that came attached to
R
the warming drawer. Save the six screws used
to attach the panel.
Using the six screws, install the metal panel
from the integrated drawer front kit onto the
warming drawer front. Make sure the brushed
side of the metal panel is facing the warming
drawer interior.
Temporarily place the decorative front panel
against the metal panel and make sure it is in
its correct final position.
Open the drawer. Trace the holes in the metal
panel onto the back of the decorative panel.
Remove the decorative panel. The markings on
the back of the decorative panel should look
like the top panel illustration below.
Draw a line from the edge of the oblong holes
to the the corresponding oblong hole below it.
The markings on the back of the decorative
panel should look like the bottom panel illustration below.
For every round marking on the decorative
panel (12 locations), drill a
eep in the back of the panel.
d
oute out the rectangular areas (8 locations)
R
1
/2" hole, 1/4" (6)
marked on the back of the decorative panel
1
/4" (6) deep.
Attach the handle hardware to the front of the
decorative panel. The integrated drawer front
kit does not include a handle. This allows the
homeowner to match handle hardware with
the surrounding cabinetry.
Install the six rubber bumpers, provided with
the drawer front kit, onto the metal panel.
Attach the decorative panel to the warming
drawer using the six 1/2" screws provided with
the kit. Refer to the illustration below for
location of bumpers and screws.
18
Back view of decorative panel
Location of bumpers and mounting
screws
INSTALLATION INSTRUCTIONS
TROUBLESHOOTING
IMPORTANT NOTE:
If the warming drawer
does not operate properly, follow these
roubleshooting steps:
t
erify that power is being supplied to the
V
warming drawer.
Check electrical connections to ensure that
the installation has been completed
correctly.
Refer to the Troubleshooting Guide in the
Wolf Warming Drawer Use & Care
Information.
If the warming drawer still does not work,
contact a Wolf authorized service center. Do
not attempt to repair the warming drawer
yourself. Wolf is not responsible for service
required to correct a faulty installation.
IF YOU NEED SERVICE
Maintain the quality built into your warming
drawer by calling a Wolf authorized service
enter.
c
or the name and number of the Wolf
F
authorized service center nearest you,
check the Locator section of our website,
olfappliance.com,or call Wolf Customer
w
Service at
800-332-9513
.
When calling for service, you will need the
model and serial numbers of the warming
drawer. Both numbers are listed on the
product rating plate, located on the left
front floor area of the inner cabinet. To
access the rating plate, the drawer must
be fully open. Refer to the illustration on
page 3.
CONTACT
NFORMATION
I
Wolf Customer
Service:
800-332-9513
Website:
wolfappliance.com
The information and images are the copyright
ty of W
oper
pr
affiliate of Sub-Zero Freezer Company, Inc.
Neither this book nor any information or images
contained her
or in part without the express written permission
of Wolf Appliance Company, LLC, an affiliate of
Sub-Zer