As you follow these instructions, you will
notice WARNING and CAUTION symbols.
This blocked information is important for the
safe and efficient installation of Wolf equipment. There are two types of potential
hazards that may occur during installation.
WOLF®is a registered trademark of Wolf Appliance Company, LLC
signals a situation where minor injury or
product damage may occur if you do not
follow instr
states a hazard that may cause serious
injury or death if precautions are not
followed.
Another footnote we would like to identify is
IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation.
uctions.
WOLF WARMING DRAWER
INSTALLATION REQUIREMENTS
IMPORTANT NOTE:
This installation must be
completed by a qualified installer or Wolf
uthorized service center technician.
a
nstaller:Please read the entire Installation
I
Instructions prior to installation. Save these
instructions for the local inspector’s refer-
nce, then leave them with the homeowner.
e
Homeowner:
Please read and keep these
instructions for future reference and be sure
to read the entire Use & Care Information
prior to use.
Any questions or problems about the
installation should be directed to your Wolf
dealer or Wolf Appliance Company, LLC at
800-332-9513. You can also visit our website
at wolfappliance.com.
IMPORTANT NOTE:
This appliance must be
installed in accordance with National Electrical
Codes, as well as all state, municipal and local
codes. The correct voltage, frequency and
amperage must be supplied to the appliance
from a dedicated, grounded circuit which is
protected by a properly sized circuit breaker or
time delay fuse. The proper voltage, frequency,
and amperage ratings are listed on the product
rating plate.
Record the model and serial numbers before
installing the warming drawer. Both numbers
re listed on the product rating plate, located
a
on the left front floor area of the inner cabinet.
To access the rating plate, the drawer must be
ully open. Refer to the illustration below.
f
Model Number WWD30
Serial Number
OUTDOOR APPLICATION
The Wolf warming drawer is designed and safe
for use in outdoor applications. When installed
outdoors, a ground fault circuit interrupter
(GFCI) is required to reduce the risk of electrical shock. All other aspects of the installation
are identical for indoor and outdoor use.
Model WWD30
with Stainless Steel
Drawer Front
Model WWD30
with Integrated
Drawer Front
Location of
rating plate
Rating plate location
3
WOLF WARMING DRAWER
ACCESSORIES
Optional accessories are available
through your
Wolf dealer. To
obtain local dealer
information, visit
the Locator section
of our website,
wolfappliance.com.
BEFORE YOU START
Proper installation is the responsibility of
the installer. Product failure due to
mproper installation is not covered under
i
the Wolf warranty. Refer to the Warming
Drawer Use & Care Information for
arranty details.
w
efore you install the warming drawer,
B
make sure you have the Wolf accessory
drawer front called for in your installation.
IMPORTANT NOTE:
If you are installing
the warming drawer with integrated drawer
front in an inset panel application, make
sure that your cabinetry meets the
minimum 33" (838) width and 25" (635)
depth requirement for this installation.
Check with local utilities for electrical codes
that apply in your area. Local codes vary.
Installation, electrical connections and
grounding must comply with applicable
codes. In the absence of local codes, the
drawer should be installed in accordance
with National Electrical Code ANSI/NFPA
70-1990 or latest edition.
This appliance must be properly grounded.
Refer to Electrical Requirements on
page 12.
Make sure you have the tools and materials
necessary for proper installation.
Warranty service must be performed by a
Wolf authorized service center. Wolf is not
equired to cor
esponsible for ser
r
vice r
faulty installation.
ect a
r
DRAWER FRONT OPTIONS
IMPORTANT NOTE:
Model WWD30 must be
installed with a Wolf stainless steel or
ntegrated drawer front.
i
lassic Stainless Steel
C
Platinum Stainless Steel
Carbon Stainless Steel
Integrated Drawer Front
WDFRONT/S
W
WWDFRONT/P
WWDFRONT/B
WWDFRONT/I
(accepts wood panel)
Drawer fronts are ordered and shipped as
sales accessories and include additional
installation instructions. Stainless steel drawer
fronts include a matching tubular handle.
The integrated drawer front accepts a custom
wood panel and handle to be provided by the
homeowner. Optional stainless steel tubular
handles in classic, platinum and carbon stainless finishes are available as sales accessories.
TOOLS AND MATERIALS REQUIRED
Wood screws or other hardware to install
the solid platform or runners that support
the warming drawer
2" (51) x 2" (51) or 2" (51) x 4" (102) lumber
for runners—runners must be able to
support 200 lbs (91 kg)
2" (51) x 2" (51) or 2" (51) x 4" (102) lumber
for anti-tip block
Power saw
Level
1
Drill and
drawer fr
/16" bit, 1/2" bit also for integrated
ont application
Dimensions in parentheses are in
millimeters unless otherwise specified.4
Phillips screwdriver
2 wood screws (provided)
ood cleats for integrated drawer fr
W
application
ont
INSTALLATION INSTRUCTIONS
285/8" (727)
OPENING WIDTH
E
5"
(127)
4"
(102)
33" (838)
RECOMMENDED CABINET WIDTH
30" min (762)
36" (914)
STANDARD
FLOOR TO
COUNTER
HEIGHT
5" min (127)
BOTTOM
OF OPENING
TO FLOOR
24" min (610)
CABINET DEPTH
91/8" (232)
OPENING
HEIGHT
237/8" min (606)
OPENING DEPTH
2"(51) x 2"(51)
ANTI-TIP BLOCK
DIMENSION
WILL VARY*
ALLOW FOR
5
/8" (16)
OVERLAP OF
DRAWER FACE
ON ALL SIDES
*Allow enough room for placement of anti-tip block and drawer face overlap.
231/2" (597)
BEHIND FRAME
297/8" (759)
OVERALL WIDTH
9"
(229)
271/8" (689)
OVERALL DEPTH
101/4"
(260)
STAINLESS STEEL DRAWER FRONT
INSTALLATION SPECIFICATIONS
he following illustrations provide the overall
T
dimensions and installation specifications for
the Wolf warming drawer with a stainless steel
rawer front.
d
Wolf recommends using a 33" (838) wide
cabinet for the warming drawer with stainless
steel drawer front. A minimum 30" (762) wide
by 24" (610) deep cabinet is required with a
minimum base support of 200 lbs (91 kg).
Refer to pages 14–15 for stainless steel drawer
front installation instructions. These instructions are also included with the stainless steel
drawer front kit.
UNDERCOUNTER INSTALLATION
For undercounter installations, 231/2" (597)
from the bottom of the warming drawer
opening to the floor is recommended. It must
be installed a minimum of 5" (127) above the
floor or 1" (25) above the toe kick.
The Wolf warming drawer with stainless steel
drawer front may be installed below an electric
or gas cooktop, provided the warming drawer
is fully enclosed, top and bottom. Allow
enough room for gas and electrical connections for the cooktop. Refer to installation
instructions for the cooktop for additional
specifications. Dimensions will vary according
to the specific installation.
*Allow 3/8" (10) additional depth for cord thickness.
Overall Dimensions – Stainless Steel Drawer Fr
ont
Undercounter Installation – Stainless Steel Drawer Front
5
WOLF WARMING DRAWER
281/2" (724)
33" (838)
RECOMMENDED CABINET WIDTH
30"min (762)
285/8" (727)
WARMING DRAWER
OPENING WIDTH
E
5"
(127)
4"
(102)
ALLOW FOR
5
/8" (16)
OVERLAP OF
DRAWER FACE
ON ALL SIDES
NOTE: Refer to the built-in 30" (762) single oven specifications for electrical location.
30-INCH OVEN
ROUGH OPENING
24"min (610)
CABINET DEPTH
23/8"
(60)
ANTI-TIP BLOCK APPLICATION
91/8" (232)
OPENING
HEIGHT
237/8"min (606)
OPENING DEPTH
273/16"
(691)
24"min
(610)
2"(51) x 2"(51)
ANTI-TIP BLOCK
PLATFORM APPLICATION
24"min (610)
CABINET DEPTH
7
/8"
(22)
91/8" (232)
OPENING
HEIGHT
237/8"min (606)
OPENING DEPTH
273/16"
(691)
24"min
(610)
7
/8" (22)
PLATFORM
STAINLESS STEEL DRAWER FRONT
INSTALLATION WITH BUILT-IN OVEN
he Wolf warming drawer with stainless steel
T
drawer front may be installed below or above
a Wolf 30" (762) built-in single oven or below a
ouble oven, provided the warming drawer is
d
fully enclosed, top and bottom. Refer to the
illustration below. Also refer to installation
instructions provided with the built-in oven for
additional specifications. Dimensions will vary
according to the specific installation.
The Wolf warming drawer is designed and
agency approved for installation with Wolf
built-in ovens.
The warming drawer platform must be able to
support 200 lbs (91 kg). It must be a minimum
of 1" (25) above the toe kick to allow for the
overlap of the warming drawer trim.
IMPORTANT NOTE:
Additional clearance
between warming drawer and oven openings
ay be required. Check that oven supports do
m
not obstruct the interior dimensions required
for the warming drawer.
When the warming drawer is installed below
built-in oven, a minimum of 2
a
3
(60)
/8"
between warming drawer and oven openings
is required for placement of the anti-tip block.
To allow the warming drawer trim and the
built-in oven trim to meet, a
7
/8" (22) platform
may be used to separate the two openings.
This will act as the support platform for the
oven and the anti-tip device for the warming
drawer. Both applications are shown in the
illustration below.
IMPORTANT NOTE:
When the warming
drawer is installed above a built-in oven, a
7
/8" (22) platform is required to allow for
clearance of overlaps.
Installation with Built-In Oven – Stainless Steel Drawer Front
6
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.