Sub-Zero UC-15I, UC-15IO, Undercounter Ice Machine Installation Manual

INSTALLATION GUIDE
Undercounter Ice Machine
Contents
Important Note
Undercounter Ice Machine . . . . . . . . . . . . . . . . . . . . . 3
Ice Machine Specifications . . . . . . . . . . . . . . . . . . . . . 4
ce Machine Installation . . . . . . . . . . . . . . . . . . . . . . . . 8
I
Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . 14
Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Features and specifications are subject to change at any time without notice. Visit subzero.com/specs for the most up-to­date information.
IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified.
o ensure the safe and efficient installation of Sub-Zero
T equipment, please take note of the following types of highlighted information throughout this guide:
CAUTION signals a situation where minor injury or product damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or death if precautions are not followed.
Undercounter Ice Machine 3
subzero.com/specs
Sub-Zero Undercounter Ice Machine
IMPORTANT NOTE: T
he importance of the installation of the Sub-Zero ice machine cannot be overemphasized. Installation must be completed by a qualified installer.
Read this entire installation guide prior to installation. There are key details that you should observe during the installation to make the process easier, problem-free and, most importantly, safe. The homeowner should keep this installation guide for future reference.
Any questions or problems regarding the installation should be directed to your authorized Sub-Zero dealer or Sub-Zero customer care at 800-222-7820. You may also check the contact & support sectionofour website, subzero.com.
Important product information, including the model and serial number of your unit are listed on the product rating plate, located in the upper left corner of the ice bin and on the back of the unit. Refer to the illustration below.
RATING PLATE
Proper installation requires connection to the water supply, a drain and a dedicated electrical circuit. These connections are the responsibilities of the installer. Improper connections can result in personal injury, property damage and improper operation.
Location of rating plate.
Ice Machine Specifications 4
18"
(457)
1
4
3
/4" (375) 2
3"
(584)
3
3
5
/8"
(854)
4" (102)
6"
(152)
24" (610)
OPENING
DEPTH
151/4"
(387)
OPENING
WIDTH
24" (610)
OPENING DEPTH
341/2" (876)
OPENING
HEIGHT
TOP VIEW
FRONT VIEWSIDE VIEW
Ice Machine Specifications
OVERALL DIMENSIONS
INSTALLATION
Specifications
Ice Storage Capacity 26 lbs (12 kg)
Shipping Weight 117 lbs (53 kg)
Overall dimensions do not include panels or handles.
IMPORTANT NOTE:
It is recommended that the electrical and water supply be placed in an adjacent cabinet. If they are placed within the opening, additional cabinet depth may be required.
Ice Machine Specifications 5
E
E
E
subzero.com/specs
Electrical Requirements
he ice machine must be installed with adequate clear-
T ance for electrical connection at the rear of the unit. The electrical supply for the ice machine requires installation of a grounded receptacle on a separate circuit, servicing only this appliance. Follow the National Electrical Code and local codes and ordinances when installing the receptacle.
IMPORTANT NOTE: Although it can be located anywhere
on the back wall, it is recommended that the receptacle be placed in an adjacent cabinet or in the lower right of the opening. If it is placed within the opening, additional cabinet depth may be required. Refer to the illustration below.
Models UC15IO and UC-15IPO are designed and safe for use in outdoor applications. When installed outdoors, a ground fault circuit interrupter (GFCI) is required to reduce the risk of electrical shock. For outdoor models, or if a ground fault circuit interrupter (GFCI) is required by local codes, it must be a breaker type, not an outlet type.
Electrical Requirements
Power Supply 115 V AC, 60 Hz
Receptacle 3-prong grounding-type
Circuit Breaker 15 amp
Minimum Circuit 4.1 amp
he electrical supply for the ice machine must be installed
T by a qualified electrician in accordance with all applicable national and local electrical codes. Observe the following:
The ice machine must be grounded in accordance with
national and local electrical codes.
A separate fuse or circuit breaker must be provided for
each ice machine.
The maximum allowable voltage variation is ±10% of
the rated voltage at ice machine start-up, when the electrical load is highest.
The minimum wire size is #14 for less than 100'
(31 m)
or #12 for more than 100' (31 m) to 200' (61 m), use solid copper conductor only. The recommended breaker is 15 amp. Local or state electrical code, length of run or materials used, can increase the minimum wire gauge required. A qualified electrician must determine the proper wire size, although #14 is the minimum size allowed.
The minimum circuit requirement is used to help select
the wire size of the electrical supply. Minimum circuit requirement is not the ice machine’s running amp load.
Observe correct polarity of incoming line voltage.
Incorrect polarity can lead to erratic ice machine opera­tion and a safety issue.
Location of electrical supply.
Do not use an extension cord or two-prong adapter. Electrical ground is required on this appliance.