Features and specications are subject to change at any
time without notice. Visit subzero.com/specs for the most
up-to-date information.
Throughout this guide, dimensions may vary by ±
1
/8" (3).
Dimensions in parentheses are millimeters unless otherwise
specied.
BUILT-IN REFRIGERATION
Built-In Refrigeration
For the built-in line, Sub-Zero designers and engineers took
a fresh look at everything, inside and out. Exterior renements include redesigned grilles and lower-prole hinges.
Inside, new technology in food preservation makes the builtin line nothing short of revolutionary.
For the classic Sub-Zero look, choose framed custom
door panels that contrast with the stainless steel full-length
handles and louvered grille (shown). The framed application is an overlay model with framed design features. Panel,
grille and handle options are available.
Panels | Custom panels, stainless steel or white enamel.
Grille | Classic louvered grille insert or solid custom panel
for 84" (standard), 83" or 88" overall unit height. Dual wide
grille for dual installations.
Handles | Full-length standard or extended.
OVERLAY
Custom overlay door panels can be combined with unique
handle hardware for design exibility. Shown with pro
handle option to complement Wolf ranges. Customize with
panel, grille and handle options.
Panels | Custom panels or stainless steel.
Grille | Solid custom panel or pro louvered grille for 84"
(standard), 83" or 88" overall unit height. Dual wide grille for
dual installations.
Handles | Custom, tubular or pro handles.
UNDERCOUNTERWINEINTEGRATEDPRO 48BUILT-IN
Framed.
6 | Sub-Zero Customer Care 800.222.7820
Overlay.
BUILT-IN REFRIGERATION
Built-In Design Options
BUILT-INPRO 48INTEGRATEDWINEUNDERCOUNTER
FLUSH INSET
The ush inset design option allows for ush door and grille
panels and custom handle hardware. Shown with tubular
handle option to match Wolf built-in ovens. The ush inset
application is an overlay model with ush inset panels. Customize with panel, grille and handle options.
Panels | Custom panels or stainless steel.
Grille | Solid custom panel or pro louvered grille for 84"
(standard), 83" or 88" overall unit height. Dual wide grille for
dual installations.
Handles | Custom, tubular or pro handles.
STAINLESS STEEL
For a professional look, classic stainless steel models
require no customization. To complement the look of Wolf
ranges, choose the pro handle option (shown). Grille and
handle options are available.
Grille | Pro louvered grille for 84" (standard), 83" or 88"
overall unit height. Dual wide grille for dual installations.
Handles | Tubular or pro handles.
Flush inset.
Stainless steel.
subzero.com/specs | 7
BUILT-IN REFRIGERATION
Overall Dimensions
ALL REFRIGERATOR | ALL FREEZER
HEIGHT DIMENSIONS ±
237/8"
(606)
36"
(914)
1
/2" (13)
733/4"
(1873)
141/8"
(359)
84"
(2134)
4" (102)
263/16"
237/8"
(665)
(606)
Overall dimensions are based on stainless steel models.
Shipping weights are based on stainless steel models.
(KG)
(KG)
BUILT-INPRO 48INTEGRATEDWINEUNDERCOUNTER
subzero.com/specs | 13
BUILT-IN REFRIGERATION
NOTE: Shaded line represents profile of unit.
SIDE
Opening Dimensions
STANDARD INSTALLATION
24" (610)
OPENING
DEPTH
TOP VIEW
W
OPENING WIDTH
FRONT VIEW
VIEW
833/4"
(2127)
OPENING
HEIGHT
OPENING WIDTH
30" Model291/2" (749)
36" Model351/2" (902)
42" Model411/2" (1054)
48" Model471/2" (1206)
W
If an 83" (2108) grille height is specied, the opening height
7
must be decreased by
specied, the opening height must be increased by 4"
/8" (22). If an 88" (2235) grille height is
(102).
If two units are installed side by side, refer to page 16 for
dual standard installations.
UNDERCOUNTERWINEINTEGRATEDPRO 48BUILT-IN
14 | Sub-Zero Customer Care 800.222.7820
BUILT-IN REFRIGERATION
*3
NOTE: Shaded line represents profile of unit with
SIDE
Opening Dimensions
FLUSH INSET INSTALLATION
263/16"
(665)
FLUSH
INSET
23/16"
DEPTH
(56)
TOP VIEW
FINISHED
CLEATS*
BUILT-INPRO 48INTEGRATEDWINEUNDERCOUNTER
1
/4"
(6)
84"
(2134)
FLUSH
INSET
HEIGHT
VIEW
" (76) typical depth. Shaded areas will be visible and should be finished to match cabinetry.
3/4" (19) panel.
11/4"
(32)
FLUSH INSET WIDTH
FRONT VIEW
W
4" (102)
11/4"
(32)
3"
(76)*
TYPICAL
23/16"
(56)
FLUSH INSET WIDTH
30" Model32" (813)
36" Model38" (965)
42" Model44" (1118)
48" Model50" (1270)
W
Dimensions assume a 3/4" (19) panel thickness.
If an 83"
height must be decreased by
(2108) grille height is specied, the ush inset
7
/8" (22). If an 88" (2235) grille
height is specied, the ush inset height must be increased
(102).
by 4"
If two units are installed side by side, refer to page 17 for
dual ush inset installations.
subzero.com/specs | 15
BUILT-IN REFRIGERATION
NOTE: Shaded line represents profile of unit.
SIDE
Opening Dimensions
DUAL STANDARD INSTALLATION
24" (610)
OPENING
DEPTH
TOP VIEW
VIEW
833/4"
(2127)
OPENING
HEIGHT
OPENING WIDTH
FRONT VIEW
DUAL OPENING WIDTH
Two 30" Models 593/4" (1518)
30" and 36" Models 653/4" (1670)
Two 36" Models 713/4" (1822)
W
W
A dual installation kit will be required for this installation.
UNDERCOUNTERWINEINTEGRATEDPRO 48BUILT-IN
16 | Sub-Zero Customer Care 800.222.7820
BUILT-IN REFRIGERATION
*3
NOTE: Shaded line represents profile of unit with
SIDE
Opening Dimensions
DUAL FLUSH INSET INSTALLATION
263/16"
(665)
FLUSH
INSET
23/16"
DEPTH
(56)
TOP VIEW
FINISHED
CLEATS*
BUILT-INPRO 48INTEGRATEDWINEUNDERCOUNTER
1
/4"
(6)
84"
(2134)
FLUSH
INSET
HEIGHT
VIEW
" (76) typical depth. Shaded areas will be visible and should be finished to match cabinetry.
3/4" (19) panel.
11/4"
(32)
FLUSH INSET WIDTH
FRONT VIEW
W
11/4"
(32)
4" (102)
3"
(76)*
TYPICAL
23/16"
(56)
DUAL FLUSH INSET WIDTH
Two 30" Models 621/4" (1581)
30" and 36" Models 681/4" (1734)
Two 36" Models741/4" (1886)
W
Dimensions assume a 3/4" (19) panel thickness. A dual installation kit will be required for this installation.
subzero.com/specs | 17
BUILT-IN REFRIGERATION
Electrical
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit, servicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause
interruption of operation.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
Electrical Supply115 VAC, 60 Hz
Service15 amp
Receptacle3-prong grounding-type
7"
E
(178)
6"
(152)
751/2" (1918)
FROM FLOOR
RIGHT SIDE
OF OPENING
Plumbing
The water supply line should be located within the shaded
area shown in the illustration below. The water supply line
should be connected to the house supply with an easily
accessible shut-off valve. Do not use self-piercing valves.
The water supply line must not interfere with installation of
the anti-tip brackets.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
to the unit at all times. A copper line is not recommended
for this application.
Installation must comply with all applicable plumbing codes.
PLUMBING REQUIREMENTS
Water Supply
Pressure35–120 psi
Excess Line for Connection36" (914)
RIGHT SIDE
OF OPENING
1
/4" OD copper, braided stainless
(2.4–8.3 bar) supplied
steel or PEX tubing
(2.4–8.3 bar)
UNDERCOUNTERWINEINTEGRATEDPRO 48BUILT-IN
Electrical supply location.
18 | Sub-Zero Customer Care 800.222.7820
1
/2" (13)
6" (152)
18" (457)
AREA EXTENDS
FORWARD ON FLOOR
Water supply location.
3" (76)
BUILT-IN REFRIGERATION
Custom Panels
BUILT-INPRO 48INTEGRATEDWINEUNDERCOUNTER
For framed, overlay and ush inset applications, custom
door panels must be provided. Handle hardware must
also be provided for overlay and ush inset applications.
Refer to panel requirements below and the charts on pages
22–27 for custom panel dimensions for your specic design
application.
IMPORTANT NOTE: Do not cover a glass door with a solid
panel.
Finish all sides of the custom panels. They may be visible
when the door is open or through the window of glass door
models.
PANEL REQUIREMENTS
WEIGHT PER PANELMAX
BI-36R, BI-36RG, BI-36F 75 lb (34 kg)
All Other Models50 lb (23 kg)
Grille Panel13 lb (6 kg)
PANEL THICKNESSMIN
Framed
Overlay and Flush Inset
1
/4" (6)
5
/8" (16)
FRAMED PANELS
The framed application is an overlay model with framed
design features. It is not a separate model.
1
If the custom panel is thinner than
/4" (6), a ller material
must be added to achieve a proper t. If the panel is thicker
1
/4" (6), rout an edge around the panel or mount the
than
custom panel on a sheet of
1
/4" (6) thick material and insert
into the channel. Refer to the illustrations below.
Routing, recessing or optional extended handles may be
required for nger clearance. Refer to the full-scale template
on page 34.
When installing two units side by side, refer to page 16 for
dual standard installations.
1
/4" (6) TRIM REVEAL
1
/4" (6) PANEL
DOOR
1
/4" (6) min
ROUT TO
DOOR
1
/4" (6)
Panel 1/4" thick or less.
Panel thicker than 1/4".
subzero.com/specs | 19
BUILT-IN REFRIGERATION
Custom Panels
PARTIAL FRAMED OPTION
The partial framed kit includes a stainless steel panel for
above and below the external dispenser. Refer to the chart
below for panel width. The kit is avail able through an authorized Sub-Zero dealer. For local dealer information, visit the
nd a showroom section of our website, subzero.com.
PARTIAL FRAMED PANEL
BI-42SD151/16" (383)
BI-48SD183/4" (476)
PANEL MOUNTING KIT
A Sub-Zero custom panel mounting kit eliminates the need
for a backer and spacer panel and is avail able through an
authorized Sub-Zero dealer. For local dealer information, visit
the nd a showroom section of our website, subzero.com.
The kit consists of mounting cleats, screws and gages used
to properly position the cleats. The kit is available for all
W
built-in models except glass door models. Dual installations
require two mounting kits.
OVERLAY PANELS
Overlay panels are typically created by combining a 3/4" (19)
custom panel, a .10"
(3) spacer panel and a
1
/4" (6) backer
panel. Refer to the illustrations below.
When installing two units side by side, refer to page 16 for
dual standard installations.
The ush inset application is an overlay model with ush
inset panels. It is not a separate model.
The ush inset design allows custom panels to be installed
ush with adjacent cabinets. Similar to overlay, ush inset
3
panels are typically created by combining a
panel, a .10"
(3) spacer panel and a
1
/4" (6) backer panel.
/4" (19) custom
Refer to the illustrations for overlay panels.
3
For ush inset panels thicker than
/4" (19), a 90° door stop
may be required to prevent interference with adjacent
cabinets. Refer to the full-scale templates at the end of this
guide.
When installing two units side by side, refer to page 17 for
dual ush inset installations.
ICE AND WATER DISPENSER
For models BI-42SD and BI-48SD, the refrigerator door
panel must include a cut-out to accommodate the external
dispenser. The thickness of the panel in this area can range
1
/4" (6) to a maximum of 11/8" (29). Refer to the illustra-
from
tions below.
Dispenser dimensions.
2"
(51)
1"
(25)
HANDLE
GLASSWELL
Dispenser dimensions.
Handle placement.
subzero.com/specs | 21
BUILT-IN REFRIGERATION
H
H
H
W
AA
A
A
H
H
W
AA
A
B
H
H
H
W
H
H
H
W
WW
H
H
H
W
AA
A
A
H
H
H
W
WW
H
H
H
W
AA
A
A
H
H
H
W
H
H
H
W
WW
H
H
H
W
WW
Framed Panel Dimensions
W
BI-36R, BI-36F
H
A
H
B
W
BI-36RG
H
H
AA
BI-30U, BI-36U(ID)
MODEL BI-36R, BI-36RG, BI-36F
REFRIGERATOR/FREEZERWH
Door Panel353/4" (908)699/16" (1767)
GRILLE (OPTIONAL)WH
Grille Panel353/4" (908)815/16" (227)
BI-36RGAB
Stiles | Rails53/16" (132)105/16" (262)
MODEL BI-30U, BI-30UG
REFRIGERATORWH
Door Panel293/4" (756)4915/16" (1268)
FREEZERWH
Drawer Panel293/4" (756)1811/16" (475)
GRILLE (OPTIONAL)WH
Grille Panel293/4" (756)815/16" (227)
BI-30UGA
Stiles | Rails53/16" (132)
H
A
H
A
H
W
W
BI-30UG, BI-36UG
H
AA
H
WW
H
BI-36UFD(ID),
BI-42UFD(ID)
MODEL BI-36U(ID), BI-36UG
REFRIGERATORWH
Door Panel353/4" (908)4915/16" (1268)
FREEZERWH
Drawer Panel353/4" (908)1811/16" (475)
GRILLE (OPTIONAL)WH
Grille Panel353/4" (908)815/16" (227)
BI-36UGA
Stiles | Rails53/16" (132)
MODEL BI-36UFD(ID)
REFRIGERATOR (2 PANELS)WH
Door Panel175/8" (448)4915/16" (1268)
FREEZERWH
Drawer Panel353/4" (908)1811/16" (475)
GRILLE (OPTIONAL)WH
Grille Panel353/4" (908)815/16" (227)
H
H
H
W
UNDERCOUNTERWINEINTEGRATEDPRO 48BUILT-IN
22 | Sub-Zero Customer Care 800.222.7820
MODEL BI-42UFD(ID)
REFRIGERATOR (2 PANELS)WH
Door Panel205/8" (524)4915/16" (1268)
FREEZERWH
Drawer Panel413/4" (1060)1811/16" (475)
GRILLE (OPTIONAL)WH
Grille Panel413/4" (1060)815/16" (227)
BUILT-IN REFRIGERATION
H
H
H
W
AA
A
A
H
H
W
H
H
W
AA
A
B
H
H
H
W
H
H
H
WW
B
A
H
H
W
WW
H
H
H
W
AA
A
A
H
H
W
AA
A
B
H
H
H
W
H
H
H
W
WW
Framed Panel Dimensions
BUILT-INPRO 48INTEGRATEDWINEUNDERCOUNTER
H
H
A
B
W
BI-36S, BI-42S(ID),
W
WW
BI-42SD, BI-48SD
BI-48S(ID)
MODEL BI-36S
REFRIGERATORWH
Door Panel1913/16" (503)699/16" (1767)
FREEZERWH
Door Panel157/16" (392)699/16" (1767)
GRILLE (OPTIONAL)WH
Grille Panel353/4" (908)815/16" (227)
MODEL BI-42S, BI-42SID, BI-42SD
REFRIGERATORWH
Door Panel2413/16" (630)699/16" (1767)
FREEZERWH
Door Panel167/16" (418)699/16" (1767)
GRILLE (OPTIONAL)WH
Grille Panel413/4" (1060)815/16" (227)
BI-42SDWH
Dispenser Cut-Out*57/8" (149)127/16" (316)
AB
Cut-Out Location17/8" (48)283/4" (730)
H
H
MODEL BI-48S, BI-48SID, BI-48SD
REFRIGERATORWH
Door Panel281/2" (724)699/16" (1767)
FREEZERWH
Door Panel183/4" (476)699/16" (1767)
GRILLE (OPTIONAL)WH
Grille Panel473/4" (1213)815/16" (227)
BI-48SDWH
Dispenser Cut-Out*57/8" (149)127/16" (316)
Cut-Out Location17/8" (48)283/4" (730)
*For models BI-42SD and BI-48SD, panel thickness in dispenser area can
range from
landing area to accommodate dispenser.
1
/4" (6) to 11/8" (29) max. If panel is thicker, rout out 1/4" (6) min at
(2108) height, subtract 1" (25) from grille panel height dimensions and for
88"
(2235) height, add 4" (102). A specic panel grille must be ordered for an
83" or 88" overall unit height.
(2134) overall unit height. For
subzero.com/specs | 27
BUILT-IN REFRIGERATION
1
/4" (6)
REVEAL
5
/16" (8)
1
/8" (3)
DOORDOOR
TOP VIEW
5
/8"
(16)
5
/16"
(8)
1
/2"
(13)
1
/2"(13)
3
/32"
(2)
5
/16"
(8)
5
/16"
(8)
5
/32"
(4)
GRILLE
DOOR
1
/4" (6)
REVEAL
5
/16" (8)
1
/8" (3)
FLUSH INSET PANEL
SPACER
BACKER
DOORDOOR
DOOR / DRAWER / GRILLE
TOP VIEWTOP VIEW
SIDE VIEW
CABINETRY
1
/4" (6)
REVEAL
5
/16" (8)
1
/8" (3)
DOORDOOR
TOP VIEWTOP VIEW
5
/8"
(16)
5
/16" (8)
1
/2"
(13)
5
/16"
(8)
3
/32"
(2)
DOOR /
DRAWER
1
/2"(13)
3
/32"
(2)
5
/16"
(8)
5
/16"
(8)
5
/32"
(4)
GRILLE
DOOR
1
/4" (6)
REVEAL
5
/16" (8)
1
/8" (3)
FLUSH INSET PANEL
SPACER
BACKER
DOORDOOR
DOOR / DRAWER / GRILLE
1
/2"(13)
5
/16"
(8)
1
/8"
(3)
CABINETRY
GRILLE
TOP VIEWTOP VIEW
SIDE VIEWSIDE VIEW
SIDE VIEW
CABINETRY
1
/2"(13)
3
/32"
(2)
5
/16"
(8)
5
/16"
(8)
5
/32"
(4)
GRILLE
DOOR
1
/4" (6)
REVEAL
5
/16" (8)
1
/8" (3)
DOORDOOR
TOP VIEWTOP VIEW
Flush Inset Panels
PANEL OFFSET
The illustrations provide panel offsets and reveals for built-in
models in a ush inset application. Refer to the chart below
for reference to the illustrations.
PANEL OFFSET
ALL REFRIGERATOR | ALL FREEZERILLUS
Door | Grille SidesA
Grille TopC
Grille Bottom | Door TopD
Door BottomF
OVER-AND-UNDERILLUS
Door (hinge) | Drawer | Grille SidesA
Doors (handle) Sides (French door only)B
Grille TopC
Grille Bottom | Door TopD
Door Bottom | Drawer TopE
Drawer BottomF
SIDE-BY-SIDEILLUS
Doors (hinge) | Grille SidesA
Doors (handle) SidesB
Grille TopC
Grille Bottom | Door TopD
Door BottomF
5
/16"
TOP VIEW
(8)
DOOR / DRAWER / GRILLE
BACKER
SPACER
FLUSH INSET PANEL
Illus. A
CABINETRY
GRILLE
Illus. C
DOOR
DRAWER
CABINETRY
5
/8"
(16)
5
/16"
(8)
SIDE VIEW
5
/16"
(8)
5
/16"
(8)
SIDE VIEW
TOP VIEW
DOORDOOR
5
1
/2"
(13)
1
/2"(13)
1
/8"
(3)
3
/32"
(2)
5
/8"(16)
5
/32"
(4)
/16" (8)
1
Illus. B
DOOR
Illus. D
/8" (3)
GRILLE
DOOR /
DRAWER
SIDE VIEW
1
/4" (6)
REVEAL
5
/16"
(8)
5
/16"
(8)
SIDE VIEW
5
5
3
/16"
(8)
/32"
(4)
/32"
(2)
1
/2"(13)
3
/32"
(2)
UNDERCOUNTERWINEINTEGRATEDPRO 48BUILT-IN
28 | Sub-Zero Customer Care 800.222.7820
Illus. E
Illus. F
BUILT-IN REFRIGERATION
Dual Installation
BUILT-INPRO 48INTEGRATEDWINEUNDERCOUNTER
If two units are installed side by side, a dual installation kit
may be required. Installations without a custom ller strip
require a dual installation kit. If a dual installation kit is not
specied, a 2"
(51) ller strip is recommended between units.
A custom ller strip is required when installing two French
door or side-by-side models. Dual installations without a
ller strip can only be accomplished using two units with
opposite hinges. Refer to the illustrations below.
Dual installation kits are available through an authorized
Sub-Zero dealer. For local dealer information, visit the nd a
showroom section of our website, subzero.com. For questions regarding the installation, call Sub-Zero customer care
at 800-222-7820.
For dual standard installations, panel dimensions are the
same as for single installations. Refer to the charts on pages
22–25. Panel dimensions and offsets for dual ush inset