Sub-Zero e Series User Manual

E SERIES BUILT-IN OVENS
INSTALLATION INSTRUCTIONS
INSTRUCCIONES DE INSTALACIÓN
INSTRUCTIONS D’INSTALLATION
ISTRUZIONI PER L’INSTALLAZIONE
INSTALLATIONSANWEISUNGEN
ENGLISH 4
ESPÃNOL 22
ITALIANO 58
DEUTSCH 76
3
As you follow these instruc tions, you will notice WARNING and CAUTION symbols. This blocked information is impor tant for the safe and efficient installation of Wolf equip­ment. There are two types of potential hazards that may occur during installation.
Another footnote we would like to identify is IMPORTANT NOTE: This highlights information that is especially relevant to a problem-free installation.
signals a situation where minor injury or product damage may occur if you do not follow instructions.
states a hazard that may cause serious injury or death if precautions are not followed.
WOLF®is a registered trademark of Wolf Appliance, Inc.
CONTACT INFORMATION
Website: wolfappliance.com
INSTALLATION REQUIREMENTS
IMPORTANT NOTE: This installation must be completed by a qualified technician.
IMPORTANT NOTE:
Save these Installation
Instructions for the local inspector’s use.
Please read the entire Installation Instruc­tions prior to installation.
Installer:
please retain these instructions for local inspector’s reference, then leave them with the homeowner.
Homeowner:
please read and keep these instructions for future reference and be sure to read the entire Use & Care Information prior to use.
IMPORTANT NOTE:
This appliance must be installed in accordance with all local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedi­cated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and amperage ratings are listed on the product rating plate.
Record the model and serial numbers before installing the built-in oven. Both numbers are listed on the rating plate, located on the right side of the oven trim, directly above the door. Open the oven door to view the rating plate. Refer to the illustration below.
WOLF E SERIES BUILT-IN OVENS
SITE PREPARATION
IMPORTANT NOTE:
A minimum 610 mm of usable cabinet depth is required, or the back panel of the cabinet may need to be removed for proper installation. A minimum 635 mm of usable cabinet depth is required for a flush inset installation. The electrical box must be flush with the back panel of the cabinet.
The installation opening must have a flat, level base platform to support the oven. Single ovens require a minimum base support of 113 kg and double ovens require a minimum base support of 181 kg.
IMPORTANT NOTE:
Wolf built-in ovens are designed and agency approved for installation with Wolf cooktops, microwaves and warming drawers only. The nominal width of the built-in oven should match the nominal width of the cooktop. A built-in oven cannot be installed below a Wolf rangetop.
RATING PLATE INFORMATION
Model Number
Serial Number
Rating plate location
Location of rating plate
5
WOLF E SERIES BUILT-IN OVENS
E SERIES BUILT-IN SINGLE OVENS
MODELS ICBSO30-2F/S AND ICBSO30-2U/S
IMPORTANT NOTE:
A minimum 610 mm of usable cabinet depth is required, or the back panel of the cabinet may need to be removed for proper installation. A minimum 635 mm of usable cabinet depth is required for a flush inset installation. The electrical box must be flush with the back panel of the cabinet.
For ease of installation, Wolf recommends using 838 mm wide cabinets with the E Series single oven. A minimum 838 mm wide cabinet is required for a flush inset installation. The cabinet base platform must be able to support 113 kg.
Refer to the following illustrations for overall dimensions, installation specifications and electrical location for the E Series single oven.
The E Series single oven requires a separate, grounded 3-wire 220-240 V AC, 50/60 Hz, 30 amp service with its own circuit breaker. Refer to Electrical Requirements on page 16. The oven is not supplied with an electrical plug.
IMPORTANT NOTE:
Unless you are using cabinets deeper than 610 mm for a standard installation or 635 mm for a flush inset installa­tion, it is recommended that the electrical supply be placed in an adjacent cabinet. Choose the location shown in the installation illustrations on pages 8–9 that best suits your installation.
OVERALL DIMENSIONS – MODELS ICBSO30-2F/S AND ICBSO30-2U/S
Unframed Model ICBSO30-2U/S shown.
6
25 mm
708 mm
759 mm
67 mm
RIGHT SIDE VIEW
CONDUIT
CHANNEL
48 mm
603 mm
BEHIND FRAME
687 mm
TOP VIEW
48 mm
718 mm
OPEN OVEN DOOR
759 mm
32 mm
603 mm
559 mm
INSTALLATION INSTRUCTIONS
E SERIES BUILT-IN SINGLE OVENS
STANDARD INSTALLATION
IMPORTANT NOTE:
For standard installations, a minimum 610 mm of usable cabinet depth is required, or the back panel of the cabinet may need to be removed for proper installation. The electrical box must be flush with the back panel of the cabinet.
For standard installations, the E Series built-in oven is installed by inserting into cabinetry from the front. The oven has a face trim on all four sides and will overlap stiles and rails. The trim overlaps 3 mm on the bottom, 8 mm on the top and 19 mm on each side.
FLUSH INSET INSTALLATION
IMPORTANT NOTE:
For flush inset installa­tions, a minimum 635 mm of usable cabinet depth is required, or the back panel of the cabinet may need to be removed for proper installation. The electrical box must be flush with the back panel of the cabinet.
The flush inset installation requires the built-in oven to be recessed into the cabinet. A minimum 838 mm wide and 635 mm deep cabinet is needed if you want the front of the oven to be flush with surrounding cabinetry.
IMPORTANT NOTE:
For flush inset installa­tions, the inside edges of the rough opening must be finished, as they will be exposed when the oven door is open. These edges should be stained instead of having a lami­nated surface, to avoid damage from high temperatures during self-clean.
COMBINATION INSTALLATIONS
The Wolf E Series single oven may be installed below a Wolf 762 mm induction, electric or gas cooktop. Unless you are using cabinets deeper than 610 mm for a standard installation or 635 mm for a flush inset installation, it is recom­mended that the electrical supply be placed in the base cabinet to the right of the oven. The E Series single oven may also be installed below a Wolf 914 mm induction, electric or gas cooktop.
A Wolf E Series single oven may be installed next to another E Series single oven. You must allow for a 64 mm space between the oven rough openings. Also, a separate inner wall is required for each oven between openings.
7
WOLF E SERIES BUILT-IN OVENS
E SERIES BUILT-IN SINGLE OVENS
E
E
127 mm
121 mm min
838 mm
RECOMMENDED CABINET WIDTH
762 mm min
95 mm min
914 mm
STANDARD
FLOOR TO COUNTER
HEIGHT
691 mm
OPENING
HEIGHT
724 mm
OPENING WIDTH
102 mm
610 mm min
OPENING DEPTH
ELECTRICAL LOCATION WITHIN OPENING APPLIES ONLY TO CABINETS DEEPER THAN 610 mm
STANDARD INSTALLATION
Overall Oven Width 759 mm
Overall Oven Height 708 mm
Overall Oven Depth (behind frame) 603 mm
Open Door Clearance 559 mm
Recommended Cabinet Width 838 mm
Minimum Cabinet Width 762 mm
Minimum Cabinet (Opening) Depth 610 mm
Opening Width 724 mm
Opening Height 691 mm
Minimum Base Support 113 kg
STANDARD INSTALLATION – MODELS ICBSO30-2F/S AND ICBSO30-2U/S
8
838 mm
762 mm min
724 mm
OPENING WIDTH
ELECTRICAL LOCATION WITHIN OPENING APPLIES ONLY TO CABINETS DEEPER THAN 610 mm
127 mm
E
102 mm
E E
610 mm
OPENING DEPTH
691 mm
OPENING
HEIGHT
RECOMMENDED CABINET WIDTH
E
INSTALLATION INSTRUCTIONS
E SERIES BUILT-IN SINGLE OVENS
FLUSH INSET INSTALLATION
Overall Oven Width 759 mm
Overall Oven Height 708 mm
Overall Oven Depth (behind frame) 603 mm
Open Door Clearance 559 mm
Minimum Base Support 113 kg
Minimum Cabinet Width 838 mm
Minimum Flush Inset Depth 635 mm
Opening Width 724 mm
Minimum Flush Inset Width 772 mm
Opening Height 691 mm
Minimum Flush Inset Height 724 mm
FLUSH INSET INSTALLATION – MODELS ICBSO30-2F/S AND ICBSO30-2U/S
IMPORTANT NOTE
For flush inset installations, the inside edges of the rough opening must be finished, as they will be exposed when the oven door is open.
9
TOP VIEW
22 mm
610 mm
min
OPENING
DEPTH
25 mm
RECOMMENDED CABINET WIDTH
838 mm min
914 mm
635 mm
min
FLUSH
INSET
DEPTH
E
SIDE VIEW
691 mm
OPENING
HEIGHT
11 mm
724 mm
min
FLUSH
INSET
HEIGHT
724 mm
OPENING WIDTH
772 mm
FLUSH INSET WIDTH
ELECTRICAL LOCATION WITHIN OPENING APPLIES ONLY TO CABINETS DEEPER THAN 635 mm
127 mm
102 mm
E
E
E
WOLF E SERIES BUILT-IN OVENS
E SERIES BUILT-IN DOUBLE OVENS
MODELS ICBDO30-2F/S AND ICBDO30-2U/S
IMPORTANT NOTE:
A minimum 610 mm of usable cabinet depth is required, or the back panel of the cabinet may need to be removed for proper installation. A minimum 635 mm of usable cabinet depth is required for a flush inset installation. The electrical box must be flush with the back panel of the cabinet.
For ease of installation, Wolf recommends using 838 mm wide cabinets with the E Series double oven. A minimum 838 mm wide cabinet is required for a flush inset installation. The cabinet base platform must be able to support 181 kg.
Refer to the following illustrations for overall dimensions, installation specifications and electrical location for the E Series double oven.
The E Series double oven requires a separate, grounded 3-wire 220-240 V AC, 50/60 Hz, 50 amp service with its own circuit breaker. Refer to Electrical Requirements on page 16. The oven is not supplied with an electrical plug.
OVERALL DIMENSIONS – MODELS ICBDO30-2F/S AND ICBDO30-2U/S
IMPORTANT NOTE:
Unless you are using cabinets deeper than 610 mm for a standard installation or 635 mm for a flush inset installa­tion, it is recommended that the electrical supply be placed in an adjacent cabinet. Choose the location shown in the installation illustrations on pages 12–13 that best suits your installation.
Unframed Model ICBDO30-2U/S shown.
10
25 mm
1280 mm 1257 mm
759 mm
67 mm
RIGHT SIDE VIEW
CONDUIT CHANNEL
48 mm
603 mm
BEHIND FRAME
TOP VIEW
48 mm
718 mm
OPEN OVEN DOOR
759 mm
32 mm
603 mm
559 mm
INSTALLATION INSTRUCTIONS
E SERIES BUILT-IN DOUBLE OVENS
STANDARD INSTALLATION
IMPORTANT NOTE:
For standard installations, a minimum 610 mm of usable cabinet depth is required, or the back panel of the cabinet may need to be removed for proper installation. The electrical box must be flush with the back panel of the cabinet.
For standard installations, the E Series built-in oven is installed by inserting into cabinetry from the front. The oven has a face trim on all four sides and will overlap stiles and rails. The trim overlaps 3 mm on the bottom, 8 mm on the top and 19 mm on each side.
FLUSH INSET INSTALLATION
IMPORTANT NOTE:
For flush inset installa­tions, a minimum 635 mm of usable cabinet depth is required, or the back panel of the cabinet may need to be removed for proper installation. The electrical box must be flush with the back panel of the cabinet.
The flush inset installation requires the built-in oven to be recessed into the cabinet. A minimum 838 mm wide and 635 mm deep cabinet is needed if you want the front of the oven to be flush with surrounding cabinetry.
IMPORTANT NOTE:
For flush inset installa­tions, the inside edges of the rough opening must be finished, as they will be exposed when the oven doors are open. These edges should be stained instead of having a lami­nated surface, to avoid damage from high temperatures during self-clean.
11
WOLF E SERIES BUILT-IN OVENS
E SERIES BUILT-IN DOUBLE OVENS
STANDARD INSTALLATION
Overall Oven Width 759 mm
Overall Oven Height 1292 mm
Overall Oven Depth (behind frame) 603 mm
Open Door Clearance 559 mm
Recommended Cabinet Width 838 mm
Minimum Cabinet Width 762 mm
Minimum Cabinet (Opening) Depth 610 mm
Opening Width 724 mm
Opening Height 1260 mm
Minimum Base Support 181 kg
STANDARD INSTALLATION – MODELS ICBDO30-2F/S AND ICBDO30-2U/S
12
838 mm
762 mm min
724 mm
OPENING WIDTH
E
610 mm min
OPENING DEPTH
1260 mm
OPENING
HEIGHT
RECOMMENDED CABINET WIDTH
1702 mm
typical
ELECTRICAL LOCATION WITHIN OPENING APPLIES ONLY TO CABINETS DEEPER THAN 610 mm
127 mm
102 mm
E
E
E
INSTALLATION INSTRUCTIONS
E SERIES BUILT-IN DOUBLE OVENS
FLUSH INSET INSTALLATION
Overall Oven Width 759 mm
Overall Oven Height 1292 mm
Overall Oven Depth (behind frame) 603 mm
Open Door Clearance 559 mm
Minimum Base Support 181 kg
Minimum Cabinet Width 838 mm
Minimum Flush Inset Depth 635 mm
Opening Width 724 mm
Minimum Flush Inset Width 772 mm
Opening Height 1260 mm
Minimum Flush Inset Height 1294 mm
FLUSH INSET INSTALLATION – MODELS ICBDO30-2F/S AND ICBDO30-2U/S
IMPORTANT NOTE
For flush inset installations, the inside edges of the rough opening must be finished, as they will be exposed when the oven doors are open.
13
TOP VIEW
22 mm
610 mm
min
OPENING
DEPTH
25 mm
RECOMMENDED CABINET WIDTH
838 mm min
914 mm
635 mm
min
FLUSH
INSET
DEPTH
E
SIDE VIEW
1260 mm
OPENING
HEIGHT
11 mm
1294 mm
min
FLUSH
INSET
HEIGHT
1702 mm
typical
724 mm
OPENING WIDTH
772 mm min
FLUSH INSET WIDTH
ELECTRICAL LOCATION WITHIN OPENING APPLIES ONLY TO CABINETS DEEPER THAN 635 mm
127 mm
102 mm
E
E
E
WOLF E SERIES BUILT-IN OVENS
STANDARD INSTALLATION OPTIONS
E SERIES BUILT-IN SINGLE OVEN
The Wolf E Series single oven may be installed in combination with a Wolf convection or non­convection microwave oven with 762 mm E Series trim kit, and a Wolf warming drawer with E Series stainless steel drawer front or integrated drawer front. Refer to the illustra­tion below, and pages 6–9 for installation spec­ifications for E Series single ovens.
Keep in mind that the size of the custom panel for the warming drawer with integrated drawer front will vary according to the specific installation. Refer to the installation instructions provided with the microwave trim kit and warming drawer front for detailed specifications. Dimensions will vary according to the specific installation.
STANDARD INSTALLATION – MODELS ICBSO30-2F/S AND ICBSO30-2U/S
Single oven installed with convection microwave with 762 mm E Series trim and warming drawer with E Series stainless steel drawer front.
14
RECOMMENDED CABINET WIDTH
838 mm
762 mm
min
699 mm
MICROWAVE
OPENING WIDTH
mm
724 mm
OVEN OPENING WIDTH
ELECTRICAL LOCATION WITHIN OPENING APPLIES ONLY TO CABINETS DEEPER THAN 610 mm
102 mm
727 mm
WARMING DRAWER
OPENING WIDTH
127
127 mm
127 mm
E
102 mm
E E
E
102 mm
511 mm
610 mm
22 mm
PLATFORM
232 mm
606 mm
min
min
min
475 mm
25 mm
691 mm
22 mm
min
51 mm
ANTI-TIP BLOCK APPLICATIONPLATFORM APPLICATION
511 mm
610 mm
min
x
51 mm
ANTI-TIP BLOCK
232 mm
606 mm
min
min
475 mm
25 mm
691 mm
60 mm
min
NOTE: Unless you are using cabinets deeper than 610 mm, it is recommended that the electrical supply for the oven be placed in an adjacent cabinet.
STANDARD INSTALLATION OPTIONS
E SERIES BUILT-IN DOUBLE OVEN
The Wolf E Series double oven may be installed in combination with a Wolf warming drawer with E Series stainless steel drawer front or integrated drawer front. Refer to the illustration below, and pages 10–13 for installa­tion specifications for E Series double ovens.
e
STANDARD INSTALLATION – MODELS ICBDO30-2F/S AND ICBDO30-2U/S
Keep in mind that the size of the custom panel for the warming drawer with integrated drawer front will vary according to the specific installation. Refer to the installation instructions provided with the warming drawer front for detailed specifications. Dimensions will vary according to the specific installation.
Double oven installed above
warming drawer with E Series stainless steel drawer front.
INSTALLATION INSTRUCTIONS
15
RECOMMENDED CABINET WIDTH
838 mm
762 mm min
E
610 mm min
22 mm
PLATFORM
232 mm
606 mm min
1260 mm
22 mm
610 mm min
51 mm x 51 mm
ANTI-TIP BLOCK
232 mm
606 mm min
ANTI-TIP BLOCK APPLICATIONPLATFORM APPLICATION
1260 mm
60 mm
ELECTRICAL LOCATION WITHIN OPENING APPLIES ONLY TO CABINETS DEEPER THAN 24" (610)
NOTE: Unless you are using cabinets deeper than 610 mm, it is recommended that th electrical supply for the oven be placed in an adjacent cabinet.
724 mm
OVEN OPENING WIDTH
127 mm
127 mm
102 mm
727 mm
WARMING DRAWER
OPENING WIDTH
102
mm
E
E
E
WOLF E SERIES BUILT-IN OVENS
IMPORTANT NOTE
Be aware of local codes and ordi­nances when installing your service.
E SERIES SINGLE OVENS
Required power supply:
220-240V AC, 50/60 Hz
Maximum connected load:
5.1 kW
Total amps:
21 amps
Minimum supply wire size:
L1, N and
ground–10 AWG
E SERIES DOUBLE OVENS
Required power supply:
220-240V AC, 50/60 Hz
Maximum connected load:
8.9 kW
Refer to the wiring diagram showing the connections for each lead to the terminal box on the unit.
ELECTRICAL REQUIREMENTS
The complete appliance must be properly grounded at all times when electrical power is applied.
NOTE: Improper connection can result in a fire hazard.
Wiring diagram
Verify that power is disconnected from the electrical box before proceeding.
Open the terminal box to expose the screws with corresponding numbers. Loosen the 1, 5, and ground screws. Run the cord through the strain relief hole and into the terminal box. Attach the Neutral wire to the number 1 position. Line should be attached to the 5 position and attach the ground to the corre­sponding ground screw. After tightening the screws, tighten down the cord strain relief and close the cover to the terminal box without pinching any of the wires.
16
N
L1
GROUND
INSTALLATION INSTRUCTIONS
ELECTRICAL REQUIREMENTS
With the oven positioned directly in front of the cabinet opening, feed the properly rated cord attached to the oven terminal box through the opening in the cabinet platform (where applicable). Then, depending upon local codes, utilize one of the following tech­niques to connect the appliance to the electri­cal power supply.
INSTALLING THE OVEN
UNPACK THE OVEN
Cut the plastic straps and remove the two V-boards. Remove the four top foam corners and the corner posts. Remove the carton sleeve by lifting the sleeve up and over the appliance.
Remove all oven racks, oven rack guides and broiler pan from inside the oven cavity. For the double oven, be sure to do this for both the upper and lower ovens.
Remove the four bottom corners. Use caution as the oven is not mounted to the shipping base. Keep the bottom foam in place when moving or carting the oven. The bottom foam also protects the factory-installed trim.
IMPORTANT NOTE:
Before moving the oven, protect any finished flooring with appropriate materials to avoid damage to the floor.
Remove and discard all packing materials, including cardboard and tape on the outside of the oven and inside the oven cavity.
Oven is not mounted to the shipping base. Do not remove banding until the oven is at the point of installation.
Do not remove the bottom foam until oven has been positioned next to the installation opening.
Do not lift the unit by the oven door handle(s). This will damage the oven door and hinges.
17
WOLF E SERIES BUILT-IN OVENS
POSITION THE OVEN
Holding the oven by the upper edge and bottom side of the oven chassis, carefully lift the oven up to the cabinet opening.
Resting the oven on the cabinet base platform, slide the oven into the opening until it is approximately 152 mm from full insertion. If applicable, ensure that the installer supplied cable slides through the opening in the cabinet platform as the oven is slid into place.
IMPORTANT NOTE:
The installer supplied cable must be placed in the recessed area located along the right rear vertical edge of the oven. Make sure that the cable is not trapped between the oven and the inner cabinet wall.
Do not block the oven air exhaust located at the bottom of the oven. Blocking the exhaust may cause cabinet damage and poor baking performance.
The oven is very heavy—use caution when lifting. It is recommended that two people lift and position the oven into the opening. Wear gloves to protect hands from any sharp edges.
INSTALLING THE OVEN
OVEN DOOR REMOVAL
To reduce the weight of the oven and ease installation, removal of the oven door(s) is an option.
To Remove Oven Door:
Open oven door all the way.
Flip down the hinge latch on each side.
Close the oven door as far as it will shut.
While holding the oven door on each side with both hands, lift the oven door up. Continue to push the oven door closed and pull it away from the oven frame.
To Reinstall Oven Door:
Insert both hanger arms into the oven frame openings.
Open the oven door. You should hear a ”click” as the door is set into place.
Move the hinge levers back to the locked position. Ensure that the door is free to open and close. If not, repeat the removal and reinstallation procedures.
18
INSTALLATION INSTRUCTIONS
INSTALLING THE OVEN
MOUNT OVEN TO CABINETRY
Once the oven is fully inserted into the cabinet opening, locate the mounting holes on the oven side trim. There will be four mounting holes for a single oven and six for a double oven. Refer to the illustration below. Use a 2 mm drill bit to drill pilot holes into the cabinet. Use the provided wood screws to secure the oven to the cabinet through the oven mounting holes.
OVEN OPERATION
IMPORTANT NOTE:
Prior to operating the oven, be sure to read the entire Wolf E Series Built-In Ovens Use & Care Information included with the oven for important safety information.
Unpack the box containing the oven compo­nents found in each oven cavity. Install the oven rack guides onto the shoulder screws located on the interior side walls of the oven. Slide the oven racks onto the support racks within the oven. There are three racks per oven. Place the broiler pan and grid on a rack within the oven, if desired.
Turn on the power supply to the oven. Set the time of day by pressing the
SET CLOCK
touch pad, input the desired time by using the number pads, then touch
ENTER
.
Select any of the ten cooking modes on the control panel. Verify that the oven is coming up to temperature. For the double oven, be sure to verify operation of both ovens.
IMPORTANT NOTE:
A small amount of smoke and odor may be noticed during the initial break-in period. Refer to the Use & Care Information for additional information.
Failure to install the mounting screws may cause the oven to move or tip forward during use. This may result in damage to the oven or personal injury.
Location of mounting holes
19
CONTACT INFORMATION
Website: wolfappliance.com
TROUBLESHOOTING
IMPORTANT NOTE:
If the built-in oven does not operate properly, follow these trouble­shooting steps:
Verify that power is being supplied to the oven.
Check the electrical connections to ensure that the installation has been completed correctly.
Follow troubleshooting procedures as described in the Wolf E Series Built-In Ovens Use & Care Information.
If the oven still does not work, contact a Wolf authorized service center. Do not attempt to repair the oven yourself. Wolf is not responsible for service required to correct a faulty installation.
WIRING DIAGRAM
The wiring diagram covering the control circuit is located on the top of the oven in a sealed plastic bag.
WOLF E SERIES BUILT-IN OVENS
IF YOU NEED SERVICE
For service in your area, contact either your Wolf dealer or visit the Showroom Locator section of our website, wolfappliance.com to find the regional distributor by country.
When calling for service, you will need the built-in oven model and serial numbers. Both numbers are listed on the product rating plate, located on the right side of the oven trim, directly above the door. Open the oven door to view the rating plate. Refer to the illustration on page 5 for location of the rating plate.
20
The information and images in this book are the copyright property of Wolf Appliance, Inc., an affiliate of Sub-Zero, Inc. Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc., an affiliate of Sub-Zero, Inc.
©Wolf Appliance, Inc. all rights reserved.
21
Cuando consulte las instrucciones que aparecen en esta guía, encontrará símbolos de AVISO y PRECAUCIÓN. Esta información en recuadros es importante para instalar el equipo de Wolf de forma segura y eficaz. Existen dos tipos de posibles riesgos que pueden producirse durante una instalación.
Otro tipo de anotación que es importante resaltar es la que se incluye en NOTA IMPORTANTE: En esta nota se resalta la información que resulta especialmente importante para que la instalación se realice sin problemas.
PRECAUCIÓN
indica una situación en la que se pueden sufrir heridas leves o provocar daños secundarios al producto si no se siguen las instrucciones.
AVISO
indica peligro de que se produzcan heridas personales graves o incluso puede provocar la muerte si no se siguen las precauciones especificadas.
WOLF®es una marca comercial registrada de Wolf Appliance, Inc.
INFORMACIÓN DE CONTACTO
Página Web: www.sub-zero.eu.com
23
REQUISITOS DE INSTALACIÓN
NOTA IMPORTANTE: Esta instalación debe ser realizada por un técnico cualificado.
NOTA IMPORTANTE:
Guarde estas instrucciones de instalación para que el inspector local pueda utilizarlas.
Lea las instrucciones de instalación antes de llevar a cabo la instalación.
Instalador:
guarde estas instrucciones para que el inspector local pueda utilizarlas como referencia y, a continuación, entréguelas al propietario del aparato.
Propietario:
lea y guarde estas instrucciones para que pueda utilizarlas como referencia en el futuro y asegúrese de leer la guía de uso y mantenimiento antes de utilizar el aparato.
NOTA IMPORTANTE:
Este aparato debe instalarse siguiendo todas las normativas nacionales correspondientes. Se debe aplicar al aparato el voltaje, la frecuencia y el amperaje adecuados desde una instalación eléctrica resistente con toma de tierra protegida por un fusible de retardo. El voltaje, la frecuencia y el amperaje se muestran en la placa de datos del producto.
Apunte la referencia del modelo y los números de serie antes de instalar el horno integrable. Encontrará estos números en la placa de datos, situada en el lado derecho del borde del horno, justo encima de la puerta. Abra la puerta del horno para verla. Observe la siguiente ilustración.
HOR NOS INTEGRABLES SERIE E DE WOLF
PREPARACIÓN DEL
SITIO
NOTA IMPORTANTE:
Es necesario dejar un fondo mínimo de 610 mm utilizables, si no, podría ser necesario quitar el panel trasero del armario para que el horno quede bien instalado. En el caso de una instalación empotrable, es necesario dejar un fondo mínimo de 635 mm utilizables. La caja de conexiones debe empotrarse con el panel trasero del armario.
La apertura de la instalación debe tener una plataforma con una superficie nivelada y plana para aguantar el horno. Los hornos sencillos necesitan un apoyo de superficie mínimo de 113 kg mientras que los hornos dobles necesitan que este apoyo sea de 181 kg.
NOTA IMPORTANTE:
Los hornos integrables Wolf están diseñados y aprobados por el organismo regulador correspondiente para que se puedan instalar solamente con placas, microondas y cajones calentadores de Wolf. El ancho nominal del horno integrable debe coincidir con el ancho nominal de la placa. No se puede instalar un horno integrable debajo de una cocina de gas de Wolf.
INFORMACIÓN DE LA PLACA DE DATOS
Referencia del modelo
Número de serie
Ubicación de la placa de datos
Ubicación de la placa de datos
24
HOR NOS INTEGRABLES SERIE E DE WOLF
HORNOS SENCILLOS INTEGRABLES
SERIE E
MODELOS ICBSO30-2F/S Y ICBSO30-2U/S
NOTA IMPORTANTE:
Es necesario dejar un fondo mínimo de 610 mm utilizables, si no, podría ser necesario quitar el panel trasero del armario para que el horno quede bien instalado. En el caso de una instalación empotrable, es necesario dejar un fondo mínimo de 635 mm utilizables. La caja de conexiones debe empotrarse con el panel trasero del armario.
Para facilitar la instalación, Wolf recomienda utilizar un armario con un ancho de 838 mm para el horno sencillo Serie E. En el caso de una instalación empotrable, es necesario que el armario tenga 838 mm de ancho como mínimo. La plataforma base del armario debe aguantar un peso de 113 kg.
Vea las siguientes ilustraciones para conocer las medidas totales, las especificaciones de instalación y la ubicación de los componentes eléctricos del horno sencillo de la Serie E.
El horno sencillo de la Serie E requiere una red eléctrica individual de 220-240 V CA, 50/60 Hz y 30 amperios, con toma a tierra, cable de tres clavijas y con su propio cortacircuitos. Consulte la sección Requisitos eléctricos en la página 34. El horno no se entrega con un enchufe eléctrico.
NOTA IMPORTANTE:
A menos que utilice armarios con un fondo superior a 610 mm para una instalación estándar o con un fondo superior a 635 mm para una instalación empotrable, se recomienda que la toma eléctrica se coloque en un armario contiguo. Elija la ubicación entre las que se muestran en las ilustraciones de instalación en las páginas 26-27 que mejor se adapte a su instalación.
MEDIDAS TOTALES - MODELOS ICBSO30-2F/S E ICBSO30-2U/S
759 mm
25 mm
708 mm
67 mm
VISTA LATERAL DERECHA
CANAL DEL
CONDUCTO PARA
CABLES
48 mm
603 mm
DETRÁS DEL MARCO
VISTA SUPERIOR
48 mm
687 mm
718 mm
PUERTA DEL HORNO ABIERTA
759 mm
32 mm
603 mm
559 mm
25
INSTRUCCIONES DE INSTALACIÓN
HORNOS SENCILLOS INTEGRABLES
SERIE E
INSTALACIÓN ESTÁNDAR
NOTA IMPORTANTE:
Para las instalaciones estándar, es necesario dejar un fondo mínimo de 610 mm utilizables, si no, podría ser necesario quitar el panel trasero del armario para que el aparato quede bien instalado. La caja de conexiones debe empotrarse con el panel trasero del armario.
Para las instalaciones estándar, el horno integrable Serie E queda instalado al insertarlo en el armario desde la parte delantera. El horno tiene un contramarco frontal en cada uno de los cuatro lados que va superpuesto sobre los raíles y montantes. El contramarco sobresale 3 mm en la parte inferior, 8 mm en la parte superior y 19 mm a cada uno de los lados.
INSTALACIÓN EMPOTRABLE
NOTA IMPORTANTE:
Para las instalaciones empotrables, es necesario dejar un fondo mínimo de 635 mm utilizables, si no, podría ser necesario quitar el panel trasero del armario para que el aparato quede bien instalado. La caja de conexiones debe empotrarse con el panel trasero del armario.
La instalación empotrable exige que el horno integrable quede bien acoplado dentro del armario. Si desea que el frente del horno quede empotrado respecto al mobiliario circundante, necesitará un mueble con un ancho mínimo de 838 mm y un fondo mínimo de 635 mm.
NOTA IMPORTANTE:
En las instalaciones empotrables, los bordes internos de la cavidad deben estar acabados, ya que quedarán expuestos cuando la puerta del horno esté abierta. Estos bordes deberían estar teñidos en vez de tener una superficie laminada con el fin de evitar que las altas temperaturas de la limpieza automática los dañen.
INSTALACIONES COMBINADAS
Los hornos sencillos Serie E de Wolf se pueden instalar debajo de una vitrocerámica, una placa de gas o de inducción de 762 mm de Wolf. A menos que utilice armarios con un fondo superior a 610 mm para una instalación estándar o con un fondo superior a 635 mm para una instalación empotrable, se recomienda que la toma eléctrica se coloque en el armario base situado a la derecha del horno. Los hornos sencillos Serie E también se pueden instalar debajo de una vitrocerámica, una placa de gas o de inducción de 914 mm de Wolf.
Además, existe la posibilidad de instalar un horno sencillo Serie E de Wolf al lado de otro horno sencillo Serie E. Debe dejar un espacio de 64 mm entre las cavidades del horno. También es necesario dejar una pared interior separada entre las cavidades de cada uno de los hornos.
26
HOR NOS INTEGRABLES SERIE E DE WOLF
HORNOS SENCILLOS INTEGRABLES
SERIE E
E
E
127 mm
121 mm mín
838 mm
ANCHURA DE ARMARIO
RECOMENDADA
762 mm mín
95 mm mín
914 mm
ALTURA
ESTÁNDAR DEL SUELO A LA ENCIMERA
691 mm
ALTURA DE LA CAVIDAD
724 mm
ANCHURA DE LA CAVIDAD
102 mm
610 mm mín
FONDO DE LA CAVIDAD
LA UBICACIÓN ELÉCTRICA DE LA CAVIDAD SE APLICA SÓLO PARA ARMARIOS CON UN FONDO SUPERIOR A 610 mm
INSTALACIÓN ESTÁNDAR
Anchura total del horno 759 mm Altura total del horno 708 mm Fondo total del horno (marco posterior) 603 mm Margen de apertura de la puerta 559 mm Anchura del armario recomendada 838 mm
Anchura mínima del mueble 762 mm Fondo mínimo del armario (apertura) 610 mm Anchura de la cavidad 724 mm Altura de la cavidad 691 mm Soporte mínimo de la base 113 kg
INSTALACIÓN ESTÁNDAR - MODELOS ICBSO30-2F/S E ICBSO30-2U/S
838 mm
ANCHURA DE ARMARIO
610 mm
FONDO DE LA CAVIDAD
691 mm
ALTURA DE LA CAVIDAD
RECOMENDADA
762 mm mín
724 mm
ANCHURA DE LA CAVIDAD
LA UBICACIÓN ELÉCTRICA DE LA CAVIDAD SE APLICA SÓLO PARA ARMARIOS CON UN FONDO SUPERIOR
A 610 mm
127 mm
E
102
mm
E E
E
27
INSTRUCCIONES DE INSTALACIÓN
HORNOS SENCILLOS INTEGRABLES
SERIE E
INSTALACIÓN EMPOTRABLE
Anchura total del horno 759 mm Altura total del horno 708 mm Fondo total del horno (marco posterior) 603 mm Margen de apertura de la puerta 559 mm Soporte mínimo de la base 113 kg
Anchura mínima del mueble 838 mm Fondo mínimo de
instalación empotrable 635 mm Anchura de la cavidad 724 mm Anchura mínima de
instalación empotrable 772 mm Altura de la cavidad 691 mm Altura mínima de
instalación empotrable 724 mm
INSTALACIÓN EMPOTRABLE - MODELOS ICBSO30-2F/S E ICBSO30-2U/S
NOTA IMPORTANTE
En las instalaciones empotrables, los bordes internos de la cavidad deben estar acabados, ya que quedarán expuestos cuando la puerta del horno esté abierta.
VISTA
SUPERIOR
610 mm
mín FONDO
DE CAVIDAD
635 mm
mín FONDO
DE INSTALACIÓN EMPOTRABLE
VISTA
LATERAL
22 mm
691 mm
ALTURA DE LA CAVIDAD
11 m m
724 mm
mín
ALTURA
DE INSTALACIÓN EMPOTRABLE
25 mm
ANCHURA DE ARMARIO RECOMENDADA
LA UBICACIÓN ELÉCTRICA DE LA CAVIDAD SE APLICA SÓLO PARA ARMARIOS CON UN FONDO SUPERIOR A 635 mm
914 mm
838 mm mín
724 mm
ANCHURA DE LA CAVIDAD
772 mm
ANCHURA DE INSTALACIÓN
EMPOTRABLE
102 mm
127 mm
E
E
E
E
28
HOR NOS INTEGRABLES SERIE E DE WOLF
HORNOS DOBLES INTEGRABLES
SERIE E
MODELOS ICBDO30-2F/S E ICBDO30-2U/S
NOTA IMPORTANTE:
Es necesario dejar un fondo mínimo de 610 mm utilizables, si no, podría ser necesario quitar el panel trasero del armario para que el horno quede bien instalado. En el caso de una instalación empotrable, es necesario dejar un fondo mínimo de 635 mm utilizables. La caja de conexiones debe empotrarse con el panel trasero del armario.
Para facilitar la instalación, Wolf recomienda utilizar un armario con un ancho de 838 mm para el horno doble Serie E. En el caso de una instalación empotrable, es necesario que el armario tenga 838 mm de ancho como mínimo. La plataforma base del armario debe aguantar un peso de 181 kg.
Vea las siguientes ilustraciones para conocer las medidas totales, las especificaciones de instalación y la ubicación de los componentes eléctricos del horno doble de la Serie E.
El horno doble Serie E requiere una red eléctrica individual de 220-240 V CA, 50/60 Hz y 50 amperios, con toma a tierra, cable de tres clavijas y con su propio cortacircuitos. Consulte la sección Requisitos eléctricos en la página 34. El horno no se entrega con un enchufe eléctrico.
MEDIDAS TOTALES - MODELOS ICBDO30-2F/S E ICBDO30-2U/S
NOTA IMPORTANTE:
A menos que utilice armarios con un fondo superior a 610 mm para una instalación estándar o con un fondo superior a 635 mm para una instalación empotrable, se recomienda que la toma eléctrica se coloque en un armario contiguo. Elija la ubicación entre las que se muestran en las ilustraciones de instalación en las páginas 30-31 que mejor se adapte a su instalación.
Se muestra el modelo ICBDO30-2U/S sin marco
25 mm
1280 mm 1257 mm
759 mm
67 mm
VISTA LATERAL DERECHA
CANAL DEL CONDUCTO
PARA CABLES
48 mm
603 mm
DETRÁS DEL MARCO
VISTA SUPERIOR
48 mm
718 mm
PUERTA DEL HORNO ABIERTA
759 mm
32 mm
603 mm
559 mm
29
INSTRUCCIONES DE INSTALACIÓN
HORNOS DOBLES INTEGRABLES
SERIE E
INSTALACIÓN ESTÁNDAR
NOTA IMPORTANTE:
Para las instalaciones estándar, es necesario dejar un fondo mínimo de 610 mm utilizables, si no, podría ser necesario quitar el panel trasero del armario para que el aparato quede bien instalado. La caja de conexiones debe empotrarse con el panel trasero del armario.
Para las instalaciones estándar, el horno integrable Serie E queda instalado al insertarlo en el armario desde la parte delantera. El horno tiene un contramarco frontal en cada uno de los cuatro lados que va superpuesto sobre los raíles y montantes. El contramarco sobresale 3 mm en la parte inferior, 8 mm en la parte superior y 19 mm a cada uno de los lados.
INSTALACIÓN EMPOTRABLE
NOTA IMPORTANTE:
Para las instalaciones empotrables, es necesario dejar un fondo mínimo de 635 mm utilizables, si no, podría ser necesario quitar el panel trasero del armario para que el aparato quede bien instalado. La caja de conexiones debe empotrarse con el panel trasero del armario.
La instalación empotrable exige que el horno integrable quede bien acoplado dentro del armario. Si desea que el frente del horno quede empotrado respecto al mobiliario circundante, necesitará un mueble con un ancho mínimo de 838 mm y un fondo mínimo de 635 mm.
NOTA IMPORTANTE:
En las instalaciones empotrables, los bordes internos de la cavidad deben estar acabados, ya que quedarán expuestos cuando las puertas del horno estén abiertas. Estos bordes deberían estar teñidos en vez de tener una superficie laminada con el fin de evitar que las altas temperaturas de la limpieza automática los dañen.
Loading...