Sub-Zero ELECTRIC COOKTOPS INSTALL GUIDE

E LECTRIC C OOKTOPS
INSTALLATION INSTRUCTIONS
As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equip­ment. There are two types of potential hazards that may occur during installation.
signals a situation where minor injury or product damage may occur if you do not follow instr
uctions.
states a hazard that may cause serious injury or death if precautions are not followed.
WOLF®is a registered trademark of Wolf Appliance Company, LLC
WOLF ELECTRIC COOKTOPS
INSTALLATION REQUIREMENTS
IMPORTANT NOTE:
Save these Installation
Instructions for the local inspector’s use.
Please read the entire Installation Instruc-
ions prior to installation.
t This installation must be completed by a
qualified technician.
Installer:
please retain these instructions for local inspector’s reference, then leave them with the homeowner.
Homeowner:
please read and keep these instructions for future reference and be sure to read the entire Use & Care Information prior to use.
IMPORTANT NOTE:
This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and amperage ratings are listed on the product rating plate.
Record the model and serial numbers before installing the cooktop. Both numbers are on the rating plate, located on the underside of the cooktop.
BEFORE YOU START
Proper installation is your responsibility. Have a qualified technician install this
ooktop. You must also assure that electri-
c cal installation is adequate and in compli­ance with all local codes and ordinances.
Installations and repairs must be performed
y a qualified or licensed contractor or
b electrician qualified or licensed by the state, province, or region where this appliance is being installed.
Make sure you have everything necessary for correct installation. It is the responsibil­ity of the installer to comply with the instal­lation clearances specified on the product rating plate. The rating plate is located on the underside of the cooktop.
Electrical ground is required; see Electrical Requirements on page 13.
Warranty service must be preformed by a Wolf authorized service center.
This cooktop is intended for indoor use.
CONTACT INFORMATION
Wolf Customer Service: 800-332-9513
Website: wolfappliance.com
Model Number
Serial Number
3
WOLF ELECTRIC COOKTOPS
D
H
E
A
B
C
F
G
SITE PREPARATION
IMPORTANT NOTE:
Installation of the Wolf
electric cooktop must meet the following
ocation requirements. All dimensions listed
l are minimum requirements for safe operation.
To eliminate the risk of burns or fire by reaching over heated surface units, c
abinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a ventilation hood that pr minimum of 5" (127) beyond dimension H on overhead cabinets.
otects horizontally a
LOCATION IN COUNTERTOP
inimum flat countertop surface. Must be
A)M
equal to or greater than cooktop width.
B)
Minimum 2" (51) wide clearance from the cooktop side edge to any combustible surface up to 18" (457) above the cooktop (noted by shaded area).
C)
Minimum 2" (51) wide clearance from the cooktop side edge to any combustible surface up to 18" (457) above the cooktop (noted by shaded area).
OVERHEAD CABINET DIMENSIONS
D)
Minimum spacing between cabinets directly over cooktop must be greater than or equal to the nominal width of the cooktop unit(s).
E)
Minimum 18" (457) vertical distance from the countertop surface to the bottom of cabinets adjacent to the cabinet directly above the cooktop unit.
F)
Minimum 24" (610) clearance between top of countertop and bottom of wood or metal cabinet which is protected by not less than
1
/4" (6) flame retardant millboard covered with not less than No. 28 MSG sheet steel, .015" (.4) stainless steel, or .024" (.6) aluminum or .02" (.5) copper. Minimum 30" (762) clearance between the top of the countertop and the bottom of an unpro­tected wood or metal cabinet.
Minimum clearances for installation
G)
Minimum 0" (0) from rear wall.
H)
Maximum 13" (330) depth of overhead cabinets dir
ectly above and within side wall
clearances.
Failure to locate the cooktop unit without the proper clearances will result in a fire hazard.
Dimensions in parentheses are in millimeters unless otherwise specified.4
INSTALLATION INSTRUCTIONS
E
133/8" (340)
CUT-OUT
WIDTH
4" (102)
FRONT OF COUNTERTOP
15"
(381)
15"
(381)
33" (838)
RECOMMENDED CABINET WIDTH
21/2"min
(64)
191/4" (489)
COOKTOP
CUT-OUT DEPTH
133/8" (340)
COOKTOP
CUT-OUT
WIDTH
191/4" (489)
COOKTOP CUT-OUT
DEPTH
21/2"min
(64)
13" max
(330)
18"
(457)
2"**
(51)
18"
(457)
2"**
(51)
24" OR 30"*
(610 or 762)
TO COUNTERTOP
NOTE: Application shown allows for installation of two 15" (381) modules side-by-side. 18" (457) recommended cabinet width for installation of single 15" (381) module. *Minimum 24" (610) from protected cabinet or 30" (762) from unprotected cabinet to countertop. **Minimum clearance from side edge of cooktop cut-out to combustible surface up to 18" (457) above countertop.
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
21"
(533)
OVERALL
DEPTH
15" (381)
OVERALL WIDTH
31/2" (89)
INSTALLATION SPECIFICATIONS
Wolf electric cooktops are designed to fit a standard 24" (610) deep base cabinet with a
5" (635) deep countertop. Before making the
2 countertop cut-out, verify that the cooktop will clear the side walls of the base cabinet below.
For framed models, a minimum 5
learance is required between the countertop
c
1
/2" (140)
and any combustible surface directly below the cooktop. For unframed models, a minimum 6" (152) clearance is required.
Refer to illustrations on the following pages for installation specifications for each of the Wolf electric cooktop models.
FRAMED
The illustrations below provide the overall dimensions, installation specifications and
ountertop cut-out for Model CT15E.
c
f Model CT15E is installed above cabinets, the
I electrical placement is not critical. A grounded electrical box should be located within 4' (1.2 m)
f the right rear of the cooktop. For installation
o above an oven, unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply be placed in the base cabinet to the right of the oven.
IMPORTANT NOTE:
and/or modules are installed side by side, refer to countertop cut-out dimensions on page 12.
INSTALLATION SPECIFICATIONS – MODEL CT15E
MODEL CT15E
When multiple cooktops
Overall Dimensions
MODEL CT15E
Overall Width 15" (381)
Overall Height 31/2" (89)
Overall Depth 21" (533)
Minimum Cabinet Depth 223/4" (578)
Minimum Height Clearance* 4" (102)
Cut-Out W
Cut-Out Depth 191/4" (489)
*Minimum 51/2" (140) clearance is
equir
r combustible sur
idth 13
ed between counter
face dir
3
/8" (340)
top and any
ectly below the
Countertop Cut-Out
cooktop.
1
Dimensions may vary to
±
/8" (3).
5
Loading...
+ 11 hidden pages