Sub-Zero BI-36UG-O, BI-36UG-F User Manual

Over-and-under Model BI-36UG offers large refrigerated storage with a glass door, plus a convenient roll-out freezer drawer. Sub-Zero dual refrigeration along with new air purification and water filtra­tion systems guard the freshness of your food and water like nothing before. Framed, overlay/flush inset and stainless steel models are available. A new flush inset installation option allows the unit to sit flush with surrounding cabinetry.
New Built-In Model BI-36UG
Over-and-Under with Glass Door
Interior Features
Refrigerator
16.1 cu ft Capacity Air Purification System 3 Adjustable Glass Shelves 1 Stationary Glass Shelf 1 High-Humidity Drawer with Dividers 1 Storage Drawer with Dividers Triple-Pane UV-Resistant Glass Door
Freezer
5.2 cu ft Capacity Water Filtration System Full-Extension Roll-Out Freezer Drawer Two-Tier Wire Storage Baskets Automatic Ice Maker
Stainless steel Model BI-36UG shown with tubular handles.
Accessories
Louvered, panel and stainless steel grilles for 83", 84" and 88" finished heights
Stainless steel front panels for framed and flush inset applications with stainless steel finish and handle options
Side panels in classic stainless steel and white
Stainless steel tubular, pro or curved handles and full-length extended handles
Dozen egg container with lid
Dual installation kit
90° door stop kit
Accessories are available through your Sub-Zero dealer. To obtain local dealer information, visit the Showroom Locator section of our website, subzero.com.
Features
Framed, overlay/flush inset and stainless steel design applications
Flush inset installation option allows unit to sit flush with surrounding cabinetry
Triple-pane, UV-resistant glass door
Air purification system
Water filtration system
Dual refrigeration system
Flip-up grille for easy access to condenser
Door shelves are adjustable in one-inch increments
Crisper and deli drawers form a special low-temperature zone
Informational freshness cards inside unit
Max ice feature to increase rate of ice production for a 24-hour period
Exceeds tough Department of Energy standards
This appliance is certified by Star-K to meet strict religious regulations in conjunction with specific instructions found on www.star-k.org.
Flip-Up Grille Air Purification System
Model Options
BI-36UG/F BI-36UG/O BI-36UG/S/TH BI-36UG/S/PH BI-36UG/S/CH
Design Framed Overlay/Flush Inset Stainless Stainless Stainless
Grille Louvered Panel Stainless Stainless Stainless
Handle Full-Length * Tubular Pro Curved
*Handle not included to allow for design flexibility.
Installation Notes
Built-In models may be used in a standard installation or in a flush inset installation which allows the unit to be flush with surrounding cabinetry.
Built-In over-and-under models with opposite hinges can be used in a dual installation.
Complete installation specifications, including panel sizes, can be found on our website, subzero.com.
Specifications
Overall Dimensions 36"W x 84"H x 24"D
Door Clearance Standard 37
1
/4"
Flush Inset 373/4"
Opening Width 35
1
/2"
Flush Inset Width 38"
Opening Height 83
3
/4"
Flush Inset Height 84"
Opening Depth 24" Flush Inset Depth 263/16"
Electrical Requirements 115 V AC, 60 Hz
15 amp circuit
Plumbing Requirements
1
/4" OD copper line
30–100 psi
Shipping Weight 523–529 lbs
Flush Inset Installation
*Anti-tip bracket must not interfere with water line. Extend water line approximately 36" from back wall.
**Dimensions based on
3
/4" (19)
panels.
Built-In Model BI-36UG Installation Specifications
Standard Installation
*Anti-tip bracket must not interfere with water line. Extend water line approximately 36" from back wall.
Dimensions in parentheses are in millimeters unless otherwise specified.
Unit dimensions may vary by ±
1
/8" (3).
Overall Dimensions
36"
(914)
84"
(2134)
24"
(610)
237/8"
(606) BEHIND FRAME
36"
(914)
371/4"
(946)
351/4"
(895)
*ANTI-TIP
BRACKET MUST NOT
WITH WATER LINE.
INTERFERE REFER TO INSTALLATION INSTRUCTIONS FOR COMPLETE DETAILS.
EXTEND WATER LINE APPROX 36" (914) FROM BACK WALL.
24" (610)
OPENING
DEPTH
TOP VIEW
833/4"
(2127)
OPENING
HEIGHT
24" (610)
OPENING
DEPTH
18" (457)*
1
/2"
(13)
OUTLINE OF
FRAMED, OVERLAY
OR STAINLESS STEEL MODEL
LOCATE
ELECTRICAL
WITHIN
SHADED AREA
351/2" (902)
OPENING WIDTH
LOCATE WATER SUPPLY
WITHIN SHADED AREA
(152)
WATER LINE
SHUT-OFF
VALVE
7"
(178)
(152)
6"
E
6"
751/2"
(1918)
18"
(457)
3" (76)
W
FRONT VIEWSIDE VIEW
18" (457)*
*ANTI-TIP
BRACKET MUST NOT
INTERFERE
WITH WATER LINE. REFER TO INSTALLATION INSTRUCTIONS FOR COMPLETE DETAILS.
**ASSUMES THICKNESS.
EXTEND WATER LINE APPROX 36" (914) FROM BACK WALL.
3
/4" (19) PANEL
24" (610)
OPENING
DEPTH
263/16" (665)
FLUSH INSET
DEPTH
1
/4" (6)
23/16"
833/4"
(2127)
OPENING
HEIGHT
(56)**
TOP VIEW
84"
(2134)
FLUSH
INSET
HEIGHT
23/16"
(56)**
23/16"
(56)
24" (610)
OPENING
DEPTH
FLUSH INSET
11/4"
(32)
1
/2"
(13)
OUTLINE
OF FLUSH INSET
APPLICATION WITH
3
/4" (19) PANEL
DETAIL
24" (610)
OPENING
DEPTH
11/4"
(32)
LOCATE WATER SUPPLY
WITHIN SHADED AREA
3" (76)
LOCATE
ELECTRICAL
WITHIN
SHADED AREA
1
/4"
(6)
351/2" (902)
OPENING WIDTH
38" (965)
FLUSH INSET WIDTH
18"
(457)
W
FRONT VIEWSIDE VIEW
(152)
(152)
WATER LINE
SHUT-OFF
VALVE
7"
(178)
(152)
(152)
6"
6"
E
6"
6"
263/16"
(665)
FLUSH INSET
DEPTH
751/2"
(1918)
11/4"
(32)
Loading...