Contents
Tubular and Pro Handle Installation
subzero.com 800.222.7820
TUBULAR HANDLE
1 Handle
2 Standoff
2 Screw, #10–24 x 2"
2 Screw, #10–24 x 21/4"
2 Washer, at
2 Washer, star
1 Instructions
PRO HANDLE
1 Handle
2 Standoff
2 Screw, #10–24 x 21/4"
2 Screw, #10–24 x 21/2"
2 Washer, at
2 Washer, star
1 Instructions
Handle Installation
Panels thicker than 3/4" may require additional counter bore
depth or longer bolts.
HANDLE LENGTH A
TUBULAR HANDLE
501/8" (1273) 471/8" (1197)
331/4" (845) 301/4" (768)
271/4" (692) 241/4" (616)
241/4" (616) 211/4" (540)
211/4" (540) 181/4" (464)
PRO HANDLE
483/8" (1229) 471/8" (1197)
311/2" (800) 301/4" (768)
251/2" (648) 241/4" (616)
221/2" (572) 211/4" (540)
191/2" (495) 181/4" (464)
FLAT
WASHER
A
STAR
WASHER
Determine the overall length of the handle. For pro handles,
the overall length includes the standoffs. Refer to the handle
length chart and illustration for the center to center dimension
(A), then mark and drill two 7/32" holes. Using a smaller bit to
drill pilot holes will help ensure a proper t.
Counter bore panels so the bolt heads and washers are
completely recessed. Place a star and at washer onto each
bolt then insert the bolts through the panel. Refer to the
illustration.
Insert the bolts through the standoffs and into the handle.
Tighten bolts to secure the handle to the panel.
Hole location.
PANEL
Panel preparation (side view).
7026122 REV-A 02/2013