Sub-Zero 700TC-PS User Manual

Planning Information
Integrated Model 700TC(I)
Over-and-Under Refrigerator / Freezer
odel 700TC
M
Model 700TCI with Ice Maker
lectronic digital
E control panel
Adjustable spill-proof
lass shelves
g
djustable glass
A shelf and deli drawer
Stationary shelf
Location of serial number
Automatic ice maker (Model 700TCI)
Front venting with removable kickplate
eamless
S molding
Adjustable dairy
ompartment
c
djustable door
A shelves
Egg container
Magnetic door /
wer gaskets
Upper freezer storage drawer
Lower freezer storage drawer
The Sub-Zero Model 700TC and 700TCI integrated design accepts custom wood or stainless steel door and drawer panels. Stainless steel panels and handles are available as sales accessories in three finishes— classic, platinum and carbon.
Dimensions in parentheses are in millimeters unless otherwise specified.
11/06
With the installation of a harness kit, these appliances are Star-K compliant to meet strict religious regulations in conjunction with specific instructions found on star-k.org. You may purchase this harness kit through your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com.
For those very small galley kitchens where y
fit a full size Built-In unit, I would beg anyone to sa
ou cannot
y they do not have room for this delightful combination model. The refrigerator door space gives you 10.2 cu ft (289 L) of storage with a temperature range of 34˚F (1˚C) to 45˚F (7˚C), while the two freezer drawers give you 5.1 cu ft (144 L) of storage in an environment where the temperature can be set between -5˚F (-20˚C) and +5˚F (-15˚C).
ou also have the option of ordering this model with
Y or without an ice maker.
ou must specify the door s
Y
wing when placing an
order.
1
Planning Information
TOP OF R
OUGH
OPENING
789/16"*
(1995)
341/2"*
(876)
1
4"
(356)
13
/16"
(21)
93/4"
(248)
4"
(102)
80"*
(2032)
27"
(686)
24"
(610)
*
1
/2" (13)
+
_
ADJUSTMENT IN LEVELING LEGS
FRONT VIEW
SIDE VIEW
(UNIT DIMENSION) (UNIT DIMENSION)
3
/8"
(10)
131/4"
(337)
1
/2"
(13)
101/4"
(260)
203/8"
(518)
DOOR
MOUNTING
DETAIL
DRAWER
MOUNTING DETAIL
105˚
90˚
90˚ DOOR OPENING
DOOR/ DRAWER
CLOSED
MAXIMUM DOOR OPENING
*
DOOR/ DRAWER PANEL THICKNESS NOT INCLUDED – DIMENSION WILL VARY WITH INSTALLATION
DOOR/ DRAWER
CLOSED
191/2"*
(495)25
1
/2"*
(648)
24"
(610)
257/8" (657)
45/8"*(117)
TOP VIEW
Integrated Model 700TC(I)
FEATURES
Tall combination unit with upper cabinet refrigerator and freezer storage drawers
Model 700TCI has automatic ice maker
Integrated design for "point-of-use" refriger­ation anywhere in the home
Dual refrigeration system with two distinct temperature zones ensures the freshest food and energy efficiency
Electronic digital controls are up front and easy to use
Flat to the ceiling bright lighting in cabinet and drawers
Door alarm will let you know with an audible beeping if a door or drawer is left open
Adjustable, spill-proof glass shelves
Refrigerator deli drawer for storage of smaller items
The exclusive dual-action hinge has a built-in 90˚ door stop
Meets strict Department of Energy require­ments
UL approved for US and Canada
Two, five and twelve year residential warranty – exclusions apply; warranty information can be found on our website,
o.com
subzer
OVERALL DIMENSIONS
Dimensions may vary by ±1/8" (3).
Dimensions in parentheses are in millimeters unless otherwise specified.
2
Planning Information
Integrated Model 700TC(I)
MODEL OPTIONS
T
all Combination Unit 700TC
Tall Combination Unit with Automatic Ice Maker 700TCI
SPECIFICATIONS
M
odel 700TC(I) Upper Cabinet Refrigerator
w
ith Freezer Drawers
Overall Width 27" (686)
Overall Height 80" (2032)
Overall Depth 24" (610)
Refrigerator Capacity 10.2 cu ft (289 L)
F
reezer Capacity 5.1 cu ft (144 L)
Minimum Height (levelers in) 791/2" (2019)
PANEL OPTIONS
Integrated (custom panels)
Classic Stainless Steel Finish /S
Platinum Stainless Steel Finish /P
Carbon Stainless Steel F
Stainless steel door and drawer front panels are ordered and shipped as sales accessories and include tubular handles.
A CCESSORIES
inish
/B
Door and drawer front panels with tubular handles in classic, platinum and carbon stainless steel
Tubular handles in classic, platinum and carbon stainless steel and polished chr
ome
Shelf and crisper assembly
Dozen egg container with lid
Dual installation heater kit
Accessories are av Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website
ailable through your
, subzer
o.com.
Door Clearance 251/2" (648)
awer Clearance 19
Dr
1
/2" (495)
Electrical Requirements 115 V AC, 60 Hz, 15 amp circuit
Plumbing Requirements
1
/4" copper line
Water Supply 20–100 psi
Annual Energy Usage 540 kWh / $ 49 (based on 9.06 cents per kilowatt hour)
Shipping Weight 360 lbs (163 kg)
Special Note Door and drawer panels and handles are
available in three stainless steel finishes
Specifications are subject to change without notice.
Dimensions in parentheses are in millimeters unless otherwise specified.
3
Planning Information
25"
(635)
27"
(686)
80"
(
2032)
27"
(
686)
25"
(
635)
ANTI-TIP
BRACKET*
W
ATER LINE
BOTTOM ENTRY
LOCATION
WATER LINE
SIDE ENTRY
LOCATIONS
11/2"
(38)
11/2"
(38)
27"
(
686)
11/2"
(38)
151/2"
(394)
9"
(229)
131/2"
(343)
131/2"
(343)
ANTI-TIP
BRACKET
6
"
(152)
TOP VIEW TOP VIEW
SIDE VIEWFRONT VIEW
WATER LINE
SIDE ENTRY
LOCATION
ANTI-TIP
BRACKET
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
41/2"
(114)
21/2" (64)
151/2" (394)
3
/4"
(19)
3"
(76)
1
/4"
(6)
13" (330) 9"
(229)
ANTI-TIP
BRACKET
LOCATE WATER LINE
(REAR ENTRY) WITHIN
SHADED AREA
LOCATE ELECTRICAL WITHIN
SHADED AREA – ORIENT GROUND
PRONG TO RIGHT AS SHOWN
*PLACEMENT OF THE
ANTI-TIP BRACKET
SHOULD BE 24" (610)
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
Integrated Model 700TC(I)
INSTALLATION SPECIFICATIONS
DIMENSIONS
Finished Rough Opening Width 27" (686)
Finished Rough Opening Height 80" (2032)
inished Rough Opening Depth 25" (635)*
F
Location of Electrical Within shaded area
Location of Plumbing (Model 700TCI only)
*The depth of the Model 700TC(I) is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum r
ough opening depth of 25" (635).
See Installation Instructions shipped with unit for detailed specifications.
Within shaded area
Dimensions in parentheses are in millimeters unless otherwise specified.
4
Planning Information
Integrated Model 700TC(I)
INSTALLATION NOTES
R
efer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics.
I
MPORTANT NOTE: The depth of Model 700TC(I) is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the installation illustration on page 4.
The anti-tip bracket must be installed to
prevent the unit from tipping forward.
Integrated units are compatible with virtually any style of cabinetry. They can be used with framed as well as frameless cabinets.
Refer to the full-scale illustrations at the end of this section for specifics on panels and door openings.
3
Door panels can grow beyond 45 and exceed the 80" (2032) height to accommo­date any size of door as long as you stay below the recommended door panel weight limit of 40 lbs (18 kg). Door panels must be a minimum
5
/8" (16) thick.
of
The weight of each dr
awer panel cannot exceed 12 lbs (5 kg). Drawer panels must be a minimum of
5
/8" (16) thick.
For the bottom drawer, the maximum panel
11
height is 16
/16" (424). You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel, so the unit can be properly vented. Any decorative base molding must be removable for possible servicing and cleaning of the condenser
e recommend using D-style handles, which
W should be located on the opposite side fr hinge, centered on the cabinet door and the top, center area of the drawer panel.
Two Integrated units may be installed next to one another
. Refer to page 11 for additional
information.
For Integrated models with an automatic ice maker, rough in the water supply line. Connect a
1
/4" OD copper line to the house supply sure to use an easily accessible shut-off valve between the supply and the unit. This shut-off valve should not be installed behind the unit.
/8"(1153)
.
om the
, being
D
o not use self-piercing valves. A saddle valve kit (4200880) is available from your Sub-Zero dealer. To obtain local dealer informa­tion, visit the Locator section of our website, s
ubzero.com.
A line filter is required when water condi­tions have a high sediment content. The ice maker operates on water pressure of 20 psi (1.4 bar) to 100 psi (6.9 bar). In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently.
When routing the water through the side
1
walls, you must place the water line within
/2" (13) of the floor and as close as possible to the back wall. The line must be routed around the anti-tip br
acket so it clears the bracket and leveling feet of the unit. Refer to the installation illustration for placement of the water line.
Do not route water supply line in front of the compressor tray. The tray must be slid forward for service.
Regardless of the routing, allow for 27" (686) of excess copper tubing to remain outside the wall or floor for easy connection to the unit, as shown in the installation illustr
ation on
page 4.
A 115 v
olt, 6OHz, 15 amp circuit breaker and electrical supply are required. A separate circuit, servicing only this appliance is necessary.
All Integrated models are equipped with a power supply cord with a 3-prong grounding plug, which must be plugged into a mating 3-prong grounding type wall receptacle. The
-
electrical outlet must be placed so the gr
ound ing prong is to the right of the thinner blades. The outlet must be flush with the back wall. Locate electrical within the shaded area shown in the installation illustration on page 4.
Do not use an extension cord or two pr
ong
adapter. Electrical ground is required.
ou must follow all National Electrical Code
Y regulations. In addition, be aware of local codes and ordinances when installing y
our service
.
The Integrated Refrigeration Installation Instructions packed with the appliance will give you step-by-step procedures for making sure the unit is installed properly.
Dimensions in parentheses are in millimeters unless otherwise specified.
5
Loading...