The Sub-Zero Model 700TC and
700TCI integrated design accepts custom
wood or stainless steel door and drawer
panels. Stainless steel panels and handles
are available as sales accessories in three
finishes— classic, platinum and carbon.
Dimensions in parentheses are in
millimeters unless otherwise specified.
11/06
With the installation of a harness kit, these appliances are Star-K
compliant to meet strict religious regulations in conjunction with
specific instructions found on star-k.org. You may purchase this
harness kit through your Sub-Zero dealer. To obtain local dealer
information, visit the Locator section of our website, subzero.com.
For those very small galley kitchens where y
fit a full size Built-In unit, I would beg anyone to sa
ou cannot
y
they do not have room for this delightful combination
model. The refrigerator door space gives you 10.2 cu ft
(289 L) of storage with a temperature range of 34˚F
(1˚C) to 45˚F (7˚C), while the two freezer drawers give
you 5.1 cu ft (144 L) of storage in an environment
where the temperature can be set between -5˚F (-20˚C)
and +5˚F (-15˚C).
ou also have the option of ordering this model with
Y
or without an ice maker.
ou must specify the door s
Y
wing when placing an
order.
1
Page 2
Planning Information
TOP OF
R
OUGH
OPENING
789/16"*
(1995)
341/2"*
(876)
1
4"
(356)
13
/16"
(21)
93/4"
(248)
4"
(102)
80"*
(2032)
27"
(686)
24"
(610)
*
1
/2" (13)
+
_
ADJUSTMENT IN LEVELING LEGS
FRONT VIEW
SIDE VIEW
(UNIT DIMENSION)(UNIT DIMENSION)
3
/8"
(10)
131/4"
(337)
1
/2"
(13)
101/4"
(260)
203/8"
(518)
DOOR
MOUNTING
DETAIL
DRAWER
MOUNTING DETAIL
105˚
90˚
90˚ DOOR OPENING
DOOR/ DRAWER
CLOSED
MAXIMUM DOOR OPENING
*
DOOR/ DRAWER PANEL THICKNESS NOT INCLUDED – DIMENSION WILL VARY WITH INSTALLATION
DOOR/ DRAWER
CLOSED
191/2"*
(495)25
1
/2"*
(648)
24"
(610)
257/8" (657)
45/8"*(117)
TOP VIEW
Integrated Model 700TC(I)
FEATURES
Tall combination unit with upper cabinet
refrigerator and freezer storage drawers
Model 700TCI has automatic ice maker
Integrated design for "point-of-use" refrigeration anywhere in the home
Dual refrigeration system with two distinct
temperature zones ensures the freshest food
and energy efficiency
Electronic digital controls are up front and
easy to use
Flat to the ceiling bright lighting in cabinet
and drawers
Door alarm will let you know with an audible
beeping if a door or drawer is left open
Adjustable, spill-proof glass shelves
Refrigerator deli drawer for storage of
smaller items
The exclusive dual-action hinge has a built-in
90˚ door stop
Meets strict Department of Energy requirements
UL approved for US and Canada
Two, five and twelve year residential
warranty – exclusions apply; warranty
information can be found on our website,
o.com
subzer
OVERALL DIMENSIONS
Dimensions may vary by ±1/8" (3).
Dimensions in parentheses are in
millimeters unless otherwise specified.
2
Page 3
Planning Information
Integrated Model 700TC(I)
MODEL OPTIONS
T
all Combination Unit700TC
Tall Combination Unit
with Automatic Ice Maker700TCI
SPECIFICATIONS
M
odel 700TC(I)Upper Cabinet Refrigerator
w
ith Freezer Drawers
Overall Width27" (686)
Overall Height80" (2032)
Overall Depth24" (610)
Refrigerator Capacity10.2 cu ft (289 L)
F
reezer Capacity5.1 cu ft (144 L)
Minimum Height (levelers in)791/2" (2019)
PANEL OPTIONS
Integrated (custom panels)
Classic Stainless Steel Finish/S
Platinum Stainless Steel Finish/P
Carbon Stainless Steel F
Stainless steel door and drawer front
panels are ordered and shipped as sales
accessories and include tubular handles.
A CCESSORIES
inish
/B
Door and drawer front panels
with tubular handles in classic,
platinum and carbon stainless
steel
Tubular handles in classic,
platinum and carbon stainless
steel and polished chr
ome
Shelf and crisper assembly
Dozen egg container with lid
Dual installation heater kit
Accessories are av
Sub-Zero dealer. To obtain local dealer
information, visit the Locator section of
our website
ailable through your
, subzer
o.com.
Door Clearance251/2" (648)
awer Clearance19
Dr
1
/2" (495)
Electrical Requirements115 V AC, 60 Hz, 15 amp circuit
Plumbing Requirements
1
/4" copper line
Water Supply20–100 psi
Annual Energy Usage540 kWh / $ 49
(based on 9.06 cents per kilowatt hour)
Shipping Weight360 lbs (163 kg)
Special NoteDoor and drawer panels and handles are
available in three stainless steel finishes
Specifications are subject to change without notice.
Dimensions in parentheses are in
millimeters unless otherwise specified.
3
Page 4
Planning Information
25"
(635)
27"
(686)
80"
(
2032)
27"
(
686)
25"
(
635)
ANTI-TIP
BRACKET*
W
ATER LINE
BOTTOM ENTRY
LOCATION
WATER LINE
SIDE ENTRY
LOCATIONS
11/2"
(38)
11/2"
(38)
27"
(
686)
11/2"
(38)
151/2"
(394)
9"
(229)
131/2"
(343)
131/2"
(343)
ANTI-TIP
BRACKET
6
"
(152)
TOP VIEWTOP VIEW
SIDE VIEWFRONT VIEW
WATER LINE
SIDE ENTRY
LOCATION
ANTI-TIP
BRACKET
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
41/2"
(114)
21/2" (64)
151/2" (394)
3
/4"
(19)
3"
(76)
1
/4"
(6)
13" (330)9"
(229)
ANTI-TIP
BRACKET
LOCATE WATER LINE
(REAR ENTRY) WITHIN
SHADED AREA
LOCATE ELECTRICAL WITHIN
SHADED AREA – ORIENT GROUND
PRONG TO RIGHT AS SHOWN
*PLACEMENT OF THE
ANTI-TIP BRACKET
SHOULD BE 24" (610)
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
Integrated Model 700TC(I)
INSTALLATION SPECIFICATIONS
DIMENSIONS
Finished Rough Opening Width27" (686)
Finished Rough Opening Height80" (2032)
inished Rough Opening Depth25" (635)*
F
Location of ElectricalWithin shaded area
Location of Plumbing (Model 700TCI only)
*The depth of the Model 700TC(I) is 24" (610) from the front of the unit to its back. Your design
may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require
a minimum r
ough opening depth of 25" (635).
See Installation Instructions shipped with unit for detailed specifications.
Within shaded area
Dimensions in parentheses are in
millimeters unless otherwise specified.
4
Page 5
Planning Information
Integrated Model 700TC(I)
INSTALLATION NOTES
R
efer to the illustrations and specifications
for overall dimensions, finished rough opening
dimensions and installation specifics.
I
MPORTANT NOTE: The depth of Model
700TC(I) is 24" (610) from the front of the unit
to its back. Your design may necessitate
moving the unit back, or cabinets forward to
achieve a flush fit. This will require a minimum
rough opening depth of 25" (635). Refer to the
installation illustration on page 4.
The anti-tip bracket must be installed to
prevent the unit from tipping forward.
Integrated units are compatible with virtually
any style of cabinetry. They can be used with
framed as well as frameless cabinets.
Refer to the full-scale illustrations at the end
of this section for specifics on panels and door
openings.
3
Door panels can grow beyond 45
and exceed the 80" (2032) height to accommodate any size of door as long as you stay below
the recommended door panel weight limit of
40 lbs (18 kg). Door panels must be a minimum
5
/8" (16) thick.
of
The weight of each dr
awer panel cannot
exceed 12 lbs (5 kg). Drawer panels must be a
minimum of
5
/8" (16) thick.
For the bottom drawer, the maximum panel
11
height is 16
/16" (424). You must keep a
minimum space of 4" (102) clear below the
bottom edge of the lower drawer panel, so the
unit can be properly vented. Any decorative
base molding must be removable for possible
servicing and cleaning of the condenser
e recommend using D-style handles, which
W
should be located on the opposite side fr
hinge, centered on the cabinet door and the top,
center area of the drawer panel.
Two Integrated units may be installed next to
one another
. Refer to page 11 for additional
information.
For Integrated models with an automatic ice
maker, rough in the water supply line. Connect a
1
/4" OD copper line to the house supply
sure to use an easily accessible shut-off valve
between the supply and the unit. This shut-off
valve should not be installed behind the unit.
/8"(1153)
.
om the
, being
D
o not use self-piercing valves. A saddle
valve kit (4200880) is available from your
Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website,
s
ubzero.com.
A line filter is required when water conditions have a high sediment content. The ice
maker operates on water pressure of 20 psi
(1.4 bar) to 100 psi (6.9 bar). In some cases a
reverse osmosis water filter system may not be
able to maintain the minimum water pressure
consistently.
When routing the water through the side
1
walls, you must place the water line within
/2"
(13) of the floor and as close as possible to the
back wall. The line must be routed around the
anti-tip br
acket so it clears the bracket and
leveling feet of the unit. Refer to the installation
illustration for placement of the water line.
Do not route water supply line in front of the
compressor tray. The tray must be slid forward
for service.
Regardless of the routing, allow for 27"
(686) of excess copper tubing to remain outside
the wall or floor for easy connection to the unit,
as shown in the installation illustr
ation on
page 4.
A 115 v
olt, 6OHz, 15 amp circuit breaker and
electrical supply are required. A separate circuit,
servicing only this appliance is necessary.
All Integrated models are equipped with a
power supply cord with a 3-prong grounding
plug, which must be plugged into a mating
3-prong grounding type wall receptacle. The
-
electrical outlet must be placed so the gr
ound
ing prong is to the right of the thinner blades.
The outlet must be flush with the back wall.
Locate electrical within the shaded area shown
in the installation illustration on page 4.
Do not use an extension cord or two pr
ong
adapter. Electrical ground is required.
ou must follow all National Electrical Code
Y
regulations. In addition, be aware of local codes
and ordinances when installing y
our service
.
The Integrated Refrigeration Installation
Instructions packed with the appliance will give
you step-by-step procedures for making sure
the unit is installed properly.
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
Page 6
Planning Information
Integrated Model 700TC(I)
CABINETRY APPLICATIONS
Integrated refrigeration is compatible with virtually any
style and look of cabinetry. The models can be used with
framed as well as frameless cabinets. Because of the
precise application and the look you may want to achieve,
there are important questions you need to answer before
ordering panels for the doors and/or drawers. As you look
at styles of cabinets, keep some important facts in mind:
As the reveal between cabinets
and the Integrated unit decreases,
the potential exists for severe
finger pinching or crushing if a
hand or fingers are placed in the
opening when the door is closing.
IMPORTANT NOTE: The depth of each Integrated unit is
24" (610) from the front of the unit to its back. You
must
allow for the thickness of the panel you are applying when
planning for the finished rough opening depth if you want
the front panel to be flush with surrounding cabinetry. You
may have to move the unit back into drywall or bring the
cabinets forward to achieve a flush fit.
Weight Limitations – The door panel cannot exceed
40 lbs (18 kg) and each drawer panel must not exceed
12 lbs (5 kg).
Panel Thickness – Door and drawer panels must be a
minimum of
The height of the door panel can grow beyond 45
5
/8" (16) thick.
3
/8"
(1153) and exceed the 80" (2032) overall height as long as
you sta
y below the recommended door panel weight limit.
The toe kick clearance can vary with the height of the
lower drawer panel; the maximum panel height is 16
11
/16"
(424). You must keep a minimum space of 4" (102) clear
below the bottom edge of the lower drawer panel so the
unit can be properly vented.
IMPOR
ANT NO
T
TE:
The inside edges of the r
ough
opening, as well as the sides and a portion of the backside
of the decorative panels will need to be finished, as they
will be exposed when the door or drawers are open.
Dimensions in parentheses are in
millimeters unless otherwise specified.
e recommend using D-style handles. F
W
or the cabinet
door, handles must be located near the edge of the panel
opposite the hinge, centered top to bottom. Locate
handles in the top center area of the dr
awer panels.
6
Page 7
Planning Information
S
UB-ZERO
UNIT
PANEL
CABINET
D
OOR
C
ABINET
FRAME
TO WALL
24
(
610)
1
/8"
(3)
REVEAL
27
(686)
P
ANEL
CABINET
D
OOR
CABINET
FRAME
S
UB-ZERO
UNIT
TO WALL
24
(
610)
1
/8"
(3)
REVEAL
27
(686)
PANEL
CABINET
DOOR
CABINET
FRAME
SUB-ZERO
UNIT
TO WALL
24
(
610)
1
1
/8" (3)
REVEAL
2
27
(686)
2
Integrated Model 700TC(I)
FRAMED CABINETRY
Traditional F
rame – full overla
y (top view).
FRAMED CABINETRY APPLICATIONS
Framed cabinetry applications present you with different
questions to address. The illustrations on this page show
common applications of framed cabinetry. These are not
meant to be the only alternatives, but are suggestions
from designers around the country. Also refer to the fullscale illustrations at the end of this section for specifics
on door openings.
IMPORTANT NOTE: The depth of each Integrated unit is
24" (610) from the front of the unit to its back. You
must
allow for the thickness of the panel you are applying when
planning for the finished rough opening depth if you want
the front panel to be flush with surrounding cabinetry. You
may have to move the unit back into drywall or bring the
cabinets forward to achieve a flush fit. Refer to the
illustrations.
Illustrations on the following pages give dimensions for an
Integrated 27" (686) wide tall unit installed within a framed
cabinetry beaded inset application. Review the illustrations,
giving particular attention to the overall panel specifications. Also refer to the full-scale illustrations at the end of
this section for specifics on door openings.
Traditional Frame – standard overlay
(top view).
aditional Frame –
r
T
3
/8" (10) offset
(top view).
Dimensions in parentheses are in
millimeters unless otherwise specified.
7
Page 8
Planning Information
A) ALL REVEALS ARE 1/8" (3)
B) DRAWER RAILS ARE ATTACHED TO DRAWER FRONTS
C) BOTTOM RAIL MUST BE REMOVABLE
*DIMENSIONS MAY VARY
C
A
A
A
B
B
TOP VIEW
AA
DOOR PA NEL
CABINET DOOR
TO WALL
SUB-ZERO
UNIT
PANEL WIDTH
11/2"
(
38)
11/2"
(38)
477/8"
(1216)
FRONT VIEWSIDE VIEW
263/4" (679)
139/16"
(345)
151/16"
(383)
84"
(2624)
11/2"
(38)
11/2"
(38)
4"*
(102)
4" (102)
80"*
(2032)
341/2"
(876)
*
24"
(610)
27"
(686)
SHADED AREA
INDICATES STATIONARY
STYLES AND RAILS
27"
(686)
24"
(610)
Integrated Model 700TC(I)
FRAMED CABINETRY – BEADED INSET APPLICATION
T
he illustration shows an Integrated 27" (686) wide tall
unit installed within a framed cabinetry beaded inset
application.
IMPORTANT NOTE: Dimensions are based on a 1/8" (3)
reveal. A reveal of up to
1
/4" (6) is possible, but panel
dimensions need to be adjusted accordingly.
Installation of an Integrated 27" (686)
wide tall unit within framed cabinetry.
*Dimensions ma
Dimensions in parentheses are in
millimeters unless otherwise specified.
ary.
y v
8
Page 9
Planning Information
A
A
A
A) ALL REVEALS ARE 1/8" (3)*DIMENSIONS MAY VARY
SIDE VIEW
24"
(610)
PANEL WIDTH
453/8"
(
1153)
263/4"* (679)
139/16"
(345)
1611/16"*
(424)
4"*
(102)
80"*
(2032)
341/2"
(876)
*
27"
(686)
FINISHED OPENING
TOE KICK
797/8"*
(2029)
Integrated Model 700TC(I)
FRAMELESS CABINETRY APPLICATIONS
The illustration below shows a hypothetical installation of
an Integrated 27" (686) wide tall unit within frameless
cabinetry. Review the illustration, giving particular attention
to the overall panel specifications. Also refer to the fullscale illustrations at the end of this section for specifics
on door openings.
FRAMELESS CABINETRY
IMPORTANT NOTE: Dimensions are based on a 1/8" (3)
reveal. A reveal of up to
1
/4" (6) is possible, but panel
dimensions need to be adjusted accordingly.
Installation of an Integr
ated 27" (686)
wide tall unit within frameless cabinetry.
*Dimensions may vary.
Dimensions in parentheses are in
millimeters unless otherwise specified.
9
Page 10
Planning Information
26
3
4
(679)
3
4
(
19)
P
ANEL
APPLIANCE
DOOR WIDTH
SUB-ZERO
UNIT
T
O BACK
OF UNIT
25
7
8
(657)
27
(686)
24
(610)
C
ABINETRY
OR SIDE
PANEL
25
(635)
C
ABINETRY
OR SIDE
PANEL
25
(635)
1
8
(3)
REVEAL
min
*
1
8
(3)
REVEAL
min
*
*SUBTRACT PANEL WIDTH FROM CABINETRY OPENING TO DETERMINE ACTUAL WIDTH OF REVEAL
26
13
16
(681)
26
13
16
(681)
3
4
(19)
PANEL
3
4
(19)
PANEL
DOOR
SUB-ZERO
UNIT
DOOR
SUB-ZERO
UNIT
54
(1372)
TO BACK
OF UNIT
24
(610)
1
8
(3)
REVEAL
min
*
1
8
(3)
REVEAL
min
*
1
8
(3)
REVEAL
min
*
*SUBTRACT PANEL WIDTH FROM CABINETRY OPENING TO DETERMINE ACTUAL WIDTH OF REVEAL
*
CABINETRY
OR SIDE
PANEL
25
(635)
CABINETRY
OR SIDE
PANEL
25
(635)
Integrated Model 700TC(I)
PANEL CONSIDERATIONS
The illustrations below provide panel
width dimensions for installation of a
27" (686) wide tall unit and for
installing two 27" (686) wide tall units
side by side.
I
MPORTANT NOTE:Dimensions are
based on a
up to
dimensions need to be adjusted
accordingly.
1
1
/8" (3) reveal. A reveal of
/4" (6) is possible, but panel
When 3/4" (19) or thicker panels are used and a reveal
less than
1
/4" (6) is maintained, the door panels may
cause damage to the Sub-Zero unit when the door is
open at the maximum 105˚ door stop. You should use
the built-in 90˚ door stop to prevent damage.
Dimensions in parentheses are in
millimeters unless otherwise specified.
Panel width dimensions for
installation of a 27" (686) wide
tall unit.
Panel width dimensions for
installation of two 27" (686)
wide tall units side by side.
10
Page 11
Planning Information
T
OP VIEW
CABINETS
25
(
635)
2
7
(686)
CABINETS
25
(
635)
2
7
(
686)
MINIMUM 5/8" (16) SIDE PANELS
TOP VIEW
CABINETS
54
(1372)
25
(635)
CABINETS
25
(635)
2
27
(686)
MINIMUM 5/8" (16) SIDE PANELS
Integrated Model 700TC(I)
Installation without side panels.
INSTALLATION OPTIONS
The illustrations on this page show some typical
installations and their dimension considerations.
The depth dimension in the illustrations may vary
depending on cabinet styles, treatment of countertops or other design options.
IMPORTANT NOTE: The depth of each Integrated
unit is 24" (610) from the front of the unit to its
back. Your design may necessitate moving the unit
back, or cabinets forward to achieve a flush fit. This
will require a minimum rough opening depth of 25"
(635). Refer to the illustrations.
Installation with side panels.
Installation of two units side b
y side
DUAL INSTALLATIONS
If two or more Integrated models are installed side
by side where there is 2" (51) or less of space
between the units, a heater kit is recommended—
TTDUAL for two tall units installed side by side and
BBDUAL for a tall unit and a dr
awer unit installed
side by side. These optional components are available through your Sub-Zero dealer. To obtain local
dealer information, visit the Locator section of our
website, subzero.com.
.
Installation at end of run.
Dimensions in parentheses are in
millimeters unless otherwise specified.
11
Page 12
Planning Information
45
3
8
(1153)
TO
BOTTOM
OF
DOOR
PANEL
TO
FLOOR
1
8
(3)
1
1
2
(
38)
TO WALL
DECORATIVE VALANCE
DECORATIVE VALANCE
CANNOT EXTEND BEYOND
THE FRONT OF THIS PLANE
REMOVABLE MOLDING
BY SUB-ZERO
TOP HINGE
25
(635)
*
FINISHED HEIGHT OF 80" (2032) IS TO TOP OF SUB-ZERO MOLDING
80*
(2032)
Integrated Model 700TC(I)
DOOR PANEL HEIGHT
The height of the door panel can grow beyond 453/8"
(1153) and exceed the 80" (2032) overall height, as long as
you stay below the recommended door panel weight limit
of 40 lbs (18 kg).
The illustration below shows how the panel may grow and
w
hat you need to consider doing to finish the area in back
of the door panel.
I
MPORTANT NOTE:The valance you use to finish the area
behind the door panel must stay behind the front plane of
the finished molding as shown in the illustration.
IMPORTANT NOTE: The depth of each Integrated unit is
24" (610) from the front of the unit to its back. Your
design may necessitate moving the unit back, or cabinets
forward to achieve a flush fit. This will require a minimum
rough opening depth of 25" (635). Refer to the illustration.
UPPER VALENCE DETAIL
Dimensions in parentheses are in
millimeters unless otherwise specified.
12
Page 13
Planning Information
10
9
16
(268)
16
11
16
(424)
PANEL
PANEL
10
(254)
4
(102)
OPTIONAL
2
5
8
(67) 4(102)
TO
9
11
16
(246)
1
2
(13)
FLOOR
TO WALL
25
(635)
BASE MOLDING MUST
BE REMOVABLE
Integrated Model 700TC(I)
TOE KICK CLEARANCE
TOE KICK AREA DETAIL
The toe kick clearance can vary with the height of the
1
lower drawer panel; the maximum panel height is 16
1
/16"
(424).
IMPORTANT NOTE: You must keep a minimum space of
4" (102) clear below the bottom edge of the lower drawer
p
anel so the unit can be properly vented. In addition, any
decorative base molding must be removable for possible
servicing and cleaning of the condenser.
The illustration below shows the area below the lower
drawer where the operating mechanical equipment of the
Integrated unit is housed.
IMPORTANT NOTE: The depth of each Integrated unit is
24" (610) from the front of the unit to its back. Your
design may necessitate moving the unit back, or cabinets
forward to achieve a flush fit. This will require a minimum
rough opening depth of 25" (635). Refer to the illustration.
Dimensions in parentheses are in
millimeters unless otherwise specified.
13
Page 14
Planning Information
1
8
3
4
MIN.
(3)
PANEL
SIDE MOLDING AND
INSTALLATION HARDWARE
PROVIDED BY SUB-ZERO
LINE OF INTERFERENCE*
AT MAXIMUM DOOR OPENING
MOUNTING BRACKET SCREW
(19)
FLUSH
FURNITURE
FINISH
LINE OF INTERFERENCE*
TO BACK
OF UNIT
24
(610)
SUB-ZERO DOOR
25
7
8
(657)
APPLIANCE DOOR WIDTH
REVEAL
T
24
(610)
LINE OF INTERFERENCE*
SUB-ZERO
DOOR
TO BACK
OF UNIT
Integrated Model 700TC(I)
FRAMED CABINETRY
IMPORTANT NOTE: The depth of each Integrated
unit is 24" (610) from the front of the unit to its
back. Your design may necessitate moving the unit
back, or cabinets forward to achieve a flush fit.
105˚ maximum door opening –
1
/4 scale (top view)
Door closed – full scale (top view)
Dimensions in parentheses are in
millimeters unless otherwise specified.
*If the panel is thicker than
utilize the built-in 90˚ door stop to prevent damage to the panel
and face fr
ame
.
3
/4" (19), it is recommended that you
14
Page 15
Planning Information
1
8
MIN.
(3)
REVEAL
3
4
PANEL
LINE OF INTERFERENCE*
AT MAXIMUM DOOR OPENING
MOUNTING BRACKET SCREW
(19)
TO BACK
OF UNIT
24
(610)
SIDE MOLDING AND
INSTALLATION HARDWARE
PROVIDED BY SUB-ZERO
LINE OF INTERFERENCE*
SUB-ZERO DOOR
25
7
8
(657)
APPLIANCE DOOR WIDTH
TO
WALL
24
(610)
LINE OF INTERFERENCE*
SUB-ZERO DOOR
3
/4" (19) DOOR PANEL
SIDE PANEL
COUNTERTOP
Integrated Model 700TC(I)
FRAMELESS CABINETRY
IMPORTANT NOTE: The depth of each Integrated
unit is 24" (610) from the front of the unit to its
back. Your design may necessitate moving the unit
back, or cabinets forward to achieve a flush fit.
105˚ maximum door opening – 1/4 scale (top view)
Adjacent side panel and countertop application
Door closed – full scale (top view)*If the panel is thicker than
Dimensions in parentheses are in
millimeters unless otherwise specified.
utilize the built-in 90˚ door stop to prevent damage to the panel
and face fr
ame
.
3
/4" (19), it is recommended that you
15
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.