Sub-Zero 700BR User Manual

Page 1
Planning Information
Integrated Model 700BR
Refrigerator Drawers
odel 700BR
M
Seamless molding
ocation of serial
L
umber
n
Magnetic drawer gaskets
nt venting with
Fro removable kickplate
These appliances are Star-K certified from the factory to meet strict religious regulations in conjunction with specific instructions found on star-k.org. No extra wiring harness is required.
Removable crisper cover
lectronic digital
E
ontrol panel
c
Upper refrigerator storage drawer
Lower refrigerator storage drawer
The Sub-Zero Model 700BR integrated design accepts custom wood or stainless steel drawer panels. Stainless steel panels and handles are available as sales accessories in three finishes— classic, platinum and carbon.
Dimensions in parentheses are in millimeters unless otherwise specified.
11/06
One of the more popular models of the Integr
line, this handy two dr
awer refriger
ation system is a
ated
must for large and small homes alike. It is a perfect illustration of the concept of a refrigeration system where you can place units where they make the most sense. They can stand alone or work together with other Sub-Zero models to satisfy anyone’s needs.
Many homeowners are using them to supplement the main Built-In unit that is installed in the home temperature r
ange of 34˚F (1˚C) to 45˚F (7˚C), they are
. With a
perfect for beverages and vegetables in the island application.
1
Page 2
DRAWER
MOUNTING DETAIL
341/2"*
(876)
93/4"
(248)
4"
(102)
FRONT VIEW
SIDE VIEW
3
/8"
(10)
131/4"
(337)
1
/2"
(13)
101/4"
(260)
203/8"
(518)
27"
(686)
24"
(610)
(UNIT DIMENSION) (UNIT DIMENSION)
*
1
/2" (13)
+
_
ADJUSTMENT IN LEVELING LEGS
*
DRAWER PANEL THICKNESS NOT INCLUDED
DRAWER CLOSED
191/2"*
(495)
24"
(610)
257/8" (657)
TOP VIEW
Planning Information
Integrated Model 700BR
FEATURES
Drawer unit with refrigerator storage
drawers
Integrated design for "point-of-use" refriger-
ation anywhere in the home
Energy Star qualified
Refrigeration system ensures the freshest
food and energy efficiency
Microprocessor offers precise temperature
control ranging from 34˚F (1˚C) to 45˚F (7˚C)
Electronic digital controls are easily accessed
in the top storage drawer
Flat to the ceiling bright lighting in storage
drawers
Alarm will let you know with an audible beeping if a drawer is left open
Removable crisper cover with a clear-view window can be used in either storage drawer
Each storage drawer has a removable divider
Meets strict Department of Energy require­ments
UL approved for US and Canada
Two, five and twelve year residential warranty – exclusions apply; warranty information can be found on our website, subzero.com
OVERALL DIMENSIONS
Dimensions may vary by ±1/8" (3).
Dimensions in parentheses are in millimeters unless otherwise specified.
2
Page 3
Planning Information
Integrated Model 700BR
SPECIFICATIONS
M
odel 700BR Drawer Refrigerator Unit
Overall Width 27" (686)
Overall Height 341/2" (876)
MODEL
D
rawer Refrigerator Unit 700BR
PANEL OPTIONS
Integrated (custom panels)
Classic Stainless Steel Finish /S
Platinum Stainless Steel Finish /P
Carbon Stainless Steel Finish /B
Stainless steel drawer front panels are ordered and shipped as sales accessories and include tubular handles.
A CCESSORIES
Drawer front panels with tubular
handles in classic
, platinum and
carbon stainless steel
Tubular handles in classic,
platinum and carbon stainless
steel and polished chrome
Dozen egg container with lid
Drawer crisper cover with lid
Dual installation heater kit
Accessories are available through your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com.
Overall Depth 24" (610)
Refrigerator Capacity 5.3 cu ft (150 L)
M
inimum Height (levelers in) 34" (864)
Drawer Clearance 191/2" (495)
Electrical Requirements 115 V AC, 60 Hz, 15 amp circuit
Annual Energy Usage 337 kWh / $ 31 (based on 9.06 cents per kilow
att hour)
Energy Star Qualified
Shipping Weight 190 lbs (86 kg)
Special Note Drawer panels and handles are
available in three stainless steel finishes
Specifications are subject to change without notice.
Dimensions in parentheses are in millimeters unless otherwise specified.
3
Page 4
A
NTI-TIP
BRACKET*
*PLACEMENT OF THE
ANTI-TIP BRACKET
SHOULD BE 24" (610)
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
41/2"
(114)
21/2" (64)
151/2" (394)
1
/4"
(6)
13" (330)
ANTI-TIP
BRACKET
LOCATE ELECTRICAL WITHIN
SHADED AREA – ORIENT GROUND
PRONG TO RIGHT AS SHOWN
25"
(635)
27"
(686)
341/2"
(876)
25"
(635)
11/2"
(38)
131/2"
(343)
TOP VIEW
SIDE VIEW FRONT VIEW
A
NTI-TIP
BRACKET
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
Planning Information
Integrated Model 700BR
INSTALLATION SPECIFICATIONS
DIMENSIONS
Finished Rough Opening Width 27" (686)
Finished Rough Opening Height 341/2" (876)
inished Rough Opening Depth 25" (635)*
F
Location of Electrical Within shaded area
Dimensions in parentheses are in millimeters unless otherwise specified.
* The depth of the Model 700BR is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635).
See Installation Instructions shipped with unit for detailed specifications.
4
Page 5
Planning Information
Integrated Model 700BR
INSTALLATION NOTES
R
efer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics.
I
MPORTANT NOTE: The depth of Model 700BR is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the instal­lation illustration on page 4.
The anti-tip bracket must be installed to
prevent the unit from tipping forward.
Integrated units are compatible with virtually any style of cabinetry. They can be used with framed as well as frameless cabinets.
The weight of each drawer panel cannot exceed 12 lbs (5 kg). Drawer panels must be a minimum of
For the bottom drawer, the maximum panel height is 16 minimum space of 4" (102) clear below the bottom edge of the lower drawer panel, so the unit can be properly vented. In addition, any decorative base molding must be removable for possible servicing and cleaning of the condenser.
We recommend using D-style handles, which should be located on the top, center area of the drawer panel.
5
/8" (16) thick.
11
/16" (424). You must keep a
T
wo Integrated units may be installed next to one another. Refer to page 10 for additional information.
A
115 volt, 6OHz, 15 amp circuit breaker and electrical supply are required. A separate circuit, servicing only this appliance is necessary.
All Integrated models are equipped with a power supply cord with a 3-prong grounding plug, which must be plugged into a mating 3-prong grounding type wall receptacle. The electrical outlet must be placed so the ground­ing prong is to the right of the thinner blades. The outlet must be flush with the back wall. Locate electrical within the shaded area shown in the installation illustration on page 4.
Do not use an extension cord or two prong adapter. Electrical ground is required on this appliance. Do not under any circumstances remove the power supply cord ground prong.
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
The Integrated Refrigeration Installation Instructions packed with the appliance will give you step-by-step procedures for making sure the unit is installed properly.
Dimensions in parentheses are in millimeters unless otherwise specified.
5
Page 6
Planning Information
Integrated Model 700BR
CABINETRY APPLICATIONS
Integrated refrigeration is compatible with virtually any style and look of cabinetry. The models can be used with framed as well as frameless cabinets. Because of the precise application and the look you may want to achieve, there are important questions you need to answer before ordering panels for the drawers. As you look at styles of cabinets, keep some important facts in mind:
IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. You
must
allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry. You may have to move the unit back into drywall or bring the cabinets forward to achieve a flush fit.
Weight Limitations – The weight of each drawer panel cannot exceed 12 lbs (5 kg).
Panel Thickness – Dr
5
/8" (16) thick.
The toe kic
k clear
lower drawer panel; the maximum panel height is 16
awer panels must be a minimum of
ance can vary with the height of the
11
/16" (424). You must keep a minimum space of 4" (102) clear below the bottom edge of the lower dr
awer panel so the
unit can be properly vented.
IMPORTANT NOTE: The inside edges of the rough opening, as well as the sides and a portion of the backside of the decorative panels will need to be finished, as they will be exposed when the drawers are open.
e recommend using D-style handles. Locate handles in
W the top center area of the drawer panels.
Dimensions in parentheses are in millimeters unless otherwise specified.
6
Page 7
Planning Information
SUB-ZERO
UNIT
P
ANEL
C
ABINET D
OOR
CABINET
FRAME
TO WALL
24
(
610)
1
/8" (3)
REVEAL
2
7
(
686)
PANEL
C
ABINET DOOR
CABINET
FRAME
SUB-ZERO
UNIT
TO WALL
24
(
610)
1
/8" (3)
REVEAL
27
(
686)
PANEL
CABINET
DOOR
CABINET
FRAME
SUB-ZERO
UNIT
TO WALL
24
(610)
1
1
/8" (3)
REVEAL
2
27
(686)
2
Integrated Model 700BR
FRAMED CABINETRY
Traditional Frame – full overlay (top view).
FRAMED CABINETRY APPLICATIONS
Framed cabinetry applications present you with different questions to address. The illustrations on this page show common applications of framed cabinetry. These are not meant to be the only alternatives, but are suggestions from designers around the country.
I
MPORTANT NOTE:The depth of each Integrated unit is
24" (610) from the front of the unit to its back. You
must
allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry. You may have to move the unit back into drywall or bring the cabinets forward to achieve a flush fit. Refer to the illustrations.
Illustrations on the following pages give dimensions for an Integrated drawer unit installed within a framed cabinetry beaded inset application. Review the illustrations, giving particular attention to the overall panel specifications.
Traditional Frame – standard overlay (top view).
raditional Frame –
T
3
/8" (10) offset
(top view).
Dimensions in parentheses are in millimeters unless otherwise specified.
7
Page 8
Planning Information
A) ALL REVEALS ARE 1/8" (3) B) DRAWER RAILS ARE ATTACHED TO DRAWER FRONTS C) BOTTOM RAIL MUST BE REMOVABLE
*DIMENSIONS MAY VARY
C
A
A
A
B
B
PANEL WIDTH
11/2"
(38)
FRONT VIEW SIDE VIEW
263/4" (679)
139/16"
(345)
151/16"
(383)
11/2"
(38)
11/2"
(38)
4"*
(102)
4" (102)
341/2"
(876)
*
24"
(610)
27"
(686)
SHADED AREA INDICATES STATIONARY STYLES AND RAILS
TOP VIEW
A A
PANEL
CABINET DOOR
TO WALL
SUB-ZERO
UNIT
27"
(686)
24"
(610)
Integrated Model 700BR
FRAMED CABINETRY – BEADED INSET APPLICATION
The illustration shows an Integrated drawer unit installed within a framed cabinetry beaded inset application.
IMPORTANT NOTE: Dimensions are based on a 1/8" (3) reveal. A reveal of up to d
imensions need to be adjusted accordingly.
1
/4" (6) is possible, but panel
Installation of an Integr
awer unit
ated dr
within framed cabinetry.
*Dimensions may vary.
Dimensions in parentheses are in millimeter
s unless otherwise specified
8
.
Page 9
A
A
A) ALL REVEALS ARE 1/8" (3) *DIMENSIONS MAY VARY
SIDE VIEW
24"
(610)
PANEL WIDTH
263/4"* (679)
139/16"
(345)
1611/16"*
(424)
4"*
(102)
341/2"
(876)
*
27"
(686)
FINISHED OPENING
TOE KICK
Planning Information
Integrated Model 700BR
FRAMELESS CABINETRY APPLICATIONS
The illustration below shows a hypothetical installation of an Integrated drawer unit within frameless cabinetry. Review the illustration, giving particular attention to the overall panel specifications.
FRAMELESS CABINETRY
IMPORTANT NOTE: Dimensions are based on a 1/8" (3)
r
eveal. A reveal of up to
1
/4"
(6) is possible, but panel
dimensions need to be adjusted accordingly.
awer unit
Installation of an Integr within frameless cabinetry.
*Dimensions may vary.
Dimensions in parentheses are in millimeters unless otherwise specified.
ated dr
9
Page 10
Planning Information
T
OP VIEW
CABINETS
25
(
635)
2
7
(686)
CABINETS
25
(
635)
2
7
(
686)
MINIMUM 5/8" (16) SIDE PANELS
TOP VIEW
CABINETS
54
(1372)
25
(635)
CABINETS
25
(635)
2
27
(686)
MINIMUM 5/8" (16) SIDE PANELS
Integrated Model 700BR
Installation without side panels.
INSTALLATION OPTIONS
The illustrations on this page show some typical installations and their dimension considerations. The depth dimension in the illustrations may vary depending on cabinet styles, treatment of counter­tops or other design options.
IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the illustrations.
Installation with side panels.
Installation of two units side b
y side
DUAL INSTALLATIONS
If two or more Integrated models are installed side by side where there is 2" (51) or less of space between the units, a heater kit is recommended— BBDUAL for two drawer units installed side by side or a drawer unit and a tall unit installed side b
y side. This optional component is available through your Sub-Zero dealer. To obtain local dealer informa­tion, visit the Locator section of our website, subzero.com.
.
Installation at end of run.
Dimensions in parentheses are in millimeters unless otherwise specified.
10
Page 11
Planning Information
10
9
16
(268)
16
11 16
(424)
PANEL
PANEL
10
(254)
4
(102)
OPTIONAL
2
5 8
(67) 4(102)
TO
9
11 16
(246)
1 2
(13)
FLOOR
TO WALL
25
(635)
BASE MOLDING MUST BE REMOVABLE
Integrated Model 700BR
TOE KICK CLEARANCE
TOE KICK AREA DETAIL
The toe kick clearance can vary with the height of the
1
lower drawer panel; the maximum panel height is 16
1
/16"
(424).
IMPORTANT NOTE: You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer p
anel so the unit can be properly vented. In addition, any decorative base molding must be removable for possible servicing and cleaning of the condenser.
The illustration below shows the area below the lower drawer where the operating mechanical equipment of the Integrated unit is housed.
IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the illustration.
Dimensions in parentheses are in millimeters unless otherwise specified.
11
Loading...