These appliances are Star-K certified from the
factory to meet strict religious regulations in
conjunction with specific instructions found on
star-k.org. No extra wiring harness is required.
Removable crisper
cover
lectronic digital
E
ontrol panel
c
Upper refrigerator
storage drawer
Lower refrigerator
storage drawer
The Sub-Zero Model 700BR integrated
design accepts custom wood or stainless
steel drawer panels. Stainless steel
panels and handles are available as sales
accessories in three finishes— classic,
platinum and carbon.
Dimensions in parentheses are in
millimeters unless otherwise specified.
11/06
One of the more popular models of the Integr
line, this handy two dr
awer refriger
ation system is a
ated
must for large and small homes alike. It is a perfect
illustration of the concept of a refrigeration system
where you can place units where they make the most
sense. They can stand alone or work together with
other Sub-Zero models to satisfy anyone’s needs.
Many homeowners are using them to supplement the
main Built-In unit that is installed in the home
temperature r
ange of 34˚F (1˚C) to 45˚F (7˚C), they are
. With a
perfect for beverages and vegetables in the island
application.
1
Page 2
DRAWER
MOUNTING DETAIL
341/2"*
(876)
93/4"
(248)
4"
(102)
FRONT VIEW
SIDE VIEW
3
/8"
(10)
131/4"
(337)
1
/2"
(13)
101/4"
(260)
203/8"
(518)
27"
(686)
24"
(610)
(UNIT DIMENSION)(UNIT DIMENSION)
*
1
/2" (13)
+
_
ADJUSTMENT IN LEVELING LEGS
*
DRAWER PANEL THICKNESS NOT INCLUDED
DRAWER CLOSED
191/2"*
(495)
24"
(610)
257/8" (657)
TOP VIEW
Planning Information
Integrated Model 700BR
FEATURES
Drawer unit with refrigerator storage
drawers
Integrated design for "point-of-use" refriger-
ation anywhere in the home
Energy Star qualified
Refrigeration system ensures the freshest
food and energy efficiency
Microprocessor offers precise temperature
control ranging from 34˚F (1˚C) to 45˚F (7˚C)
Electronic digital controls are easily accessed
in the top storage drawer
Flat to the ceiling bright lighting in storage
drawers
Alarm will let you know with an audible
beeping if a drawer is left open
Removable crisper cover with a clear-view
window can be used in either storage
drawer
Each storage drawer has a removable divider
Meets strict Department of Energy requirements
UL approved for US and Canada
Two, five and twelve year residential
warranty – exclusions apply; warranty
information can be found on our website,
subzero.com
OVERALL DIMENSIONS
Dimensions may vary by ±1/8" (3).
Dimensions in parentheses are in
millimeters unless otherwise specified.
2
Page 3
Planning Information
Integrated Model 700BR
SPECIFICATIONS
M
odel 700BRDrawer Refrigerator Unit
Overall Width27" (686)
Overall Height341/2" (876)
MODEL
D
rawer Refrigerator Unit700BR
PANEL OPTIONS
Integrated (custom panels)
Classic Stainless Steel Finish/S
Platinum Stainless Steel Finish/P
Carbon Stainless Steel Finish/B
Stainless steel drawer front panels are
ordered and shipped as sales accessories
and include tubular handles.
A CCESSORIES
Drawer front panels with tubular
handles in classic
, platinum and
carbon stainless steel
Tubular handles in classic,
platinum and carbon stainless
steel and polished chrome
Dozen egg container with lid
Drawer crisper cover with lid
Dual installation heater kit
Accessories are available through your
Sub-Zero dealer. To obtain local dealer
information, visit the Locator section of
our website, subzero.com.
Overall Depth24" (610)
Refrigerator Capacity5.3 cu ft (150 L)
M
inimum Height (levelers in)34" (864)
Drawer Clearance191/2" (495)
Electrical Requirements115 V AC, 60 Hz, 15 amp circuit
Annual Energy Usage337 kWh / $ 31
(based on 9.06 cents per kilow
att hour)
Energy Star Qualified
Shipping Weight190 lbs (86 kg)
Special NoteDrawer panels and handles are
available in three stainless steel finishes
Specifications are subject to change without notice.
Dimensions in parentheses are in
millimeters unless otherwise specified.
3
Page 4
A
NTI-TIP
BRACKET*
*PLACEMENT OF THE
ANTI-TIP BRACKET
SHOULD BE 24" (610)
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
41/2"
(114)
21/2" (64)
151/2" (394)
1
/4"
(6)
13" (330)
ANTI-TIP
BRACKET
LOCATE ELECTRICAL WITHIN
SHADED AREA – ORIENT GROUND
PRONG TO RIGHT AS SHOWN
25"
(635)
27"
(686)
341/2"
(876)
25"
(635)
11/2"
(38)
131/2"
(343)
TOP VIEW
SIDE VIEW FRONT VIEW
A
NTI-TIP
BRACKET
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
Planning Information
Integrated Model 700BR
INSTALLATION SPECIFICATIONS
DIMENSIONS
Finished Rough Opening Width27" (686)
Finished Rough Opening Height341/2" (876)
inished Rough Opening Depth25" (635)*
F
Location of ElectricalWithin shaded area
Dimensions in parentheses are in
millimeters unless otherwise specified.
* The depth of the Model 700BR is 24" (610) from the front of the unit to its back. Your design
may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require
a minimum rough opening depth of 25" (635).
See Installation Instructions shipped with unit for detailed specifications.
4
Page 5
Planning Information
Integrated Model 700BR
INSTALLATION NOTES
R
efer to the illustrations and specifications
for overall dimensions, finished rough opening
dimensions and installation specifics.
I
MPORTANT NOTE: The depth of Model 700BR
is 24" (610) from the front of the unit to its
back. Your design may necessitate moving the
unit back, or cabinets forward to achieve a
flush fit. This will require a minimum rough
opening depth of 25" (635). Refer to the installation illustration on page 4.
The anti-tip bracket must be installed to
prevent the unit from tipping forward.
Integrated units are compatible with virtually
any style of cabinetry. They can be used with
framed as well as frameless cabinets.
The weight of each drawer panel cannot
exceed 12 lbs (5 kg). Drawer panels must be a
minimum of
For the bottom drawer, the maximum panel
height is 16
minimum space of 4" (102) clear below the
bottom edge of the lower drawer panel, so the
unit can be properly vented. In addition, any
decorative base molding must be removable for
possible servicing and cleaning of the
condenser.
We recommend using D-style handles, which
should be located on the top, center area of the
drawer panel.
5
/8" (16) thick.
11
/16" (424). You must keep a
T
wo Integrated units may be installed next to
one another. Refer to page 10 for additional
information.
A
115 volt, 6OHz, 15 amp circuit breaker and
electrical supply are required. A separate circuit,
servicing only this appliance is necessary.
All Integrated models are equipped with a
power supply cord with a 3-prong grounding
plug, which must be plugged into a mating
3-prong grounding type wall receptacle. The
electrical outlet must be placed so the grounding prong is to the right of the thinner blades.
The outlet must be flush with the back wall.
Locate electrical within the shaded area shown
in the installation illustration on page 4.
Do not use an extension cord or two prong
adapter. Electrical ground is required on this
appliance. Do not under any circumstances
remove the power supply cord ground prong.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
The Integrated Refrigeration Installation
Instructions packed with the appliance will give
you step-by-step procedures for making sure
the unit is installed properly.
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
Page 6
Planning Information
Integrated Model 700BR
CABINETRY APPLICATIONS
Integrated refrigeration is compatible with virtually any
style and look of cabinetry. The models can be used with
framed as well as frameless cabinets. Because of the
precise application and the look you may want to achieve,
there are important questions you need to answer before
ordering panels for the drawers. As you look at styles of
cabinets, keep some important facts in mind:
IMPORTANT NOTE: The depth of each Integrated unit is
24" (610) from the front of the unit to its back. You
must
allow for the thickness of the panel you are applying when
planning for the finished rough opening depth if you want
the front panel to be flush with surrounding cabinetry. You
may have to move the unit back into drywall or bring the
cabinets forward to achieve a flush fit.
Weight Limitations – The weight of each drawer panel
cannot exceed 12 lbs (5 kg).
Panel Thickness – Dr
5
/8" (16) thick.
The toe kic
k clear
lower drawer panel; the maximum panel height is 16
awer panels must be a minimum of
ance can vary with the height of the
11
/16"
(424). You must keep a minimum space of 4" (102) clear
below the bottom edge of the lower dr
awer panel so the
unit can be properly vented.
IMPORTANT NOTE: The inside edges of the rough
opening, as well as the sides and a portion of the backside
of the decorative panels will need to be finished, as they
will be exposed when the drawers are open.
e recommend using D-style handles. Locate handles in
W
the top center area of the drawer panels.
Dimensions in parentheses are in
millimeters unless otherwise specified.
6
Page 7
Planning Information
SUB-ZERO
UNIT
P
ANEL
C
ABINET
D
OOR
CABINET
FRAME
TO WALL
24
(
610)
1
/8" (3)
REVEAL
2
7
(
686)
PANEL
C
ABINET
DOOR
CABINET
FRAME
SUB-ZERO
UNIT
TO WALL
24
(
610)
1
/8" (3)
REVEAL
27
(
686)
PANEL
CABINET
DOOR
CABINET
FRAME
SUB-ZERO
UNIT
TO WALL
24
(610)
1
1
/8" (3)
REVEAL
2
27
(686)
2
Integrated Model 700BR
FRAMED CABINETRY
Traditional Frame – full overlay (top view).
FRAMED CABINETRY APPLICATIONS
Framed cabinetry applications present you with different
questions to address. The illustrations on this page show
common applications of framed cabinetry. These are not
meant to be the only alternatives, but are suggestions
from designers around the country.
I
MPORTANT NOTE:The depth of each Integrated unit is
24" (610) from the front of the unit to its back. You
must
allow for the thickness of the panel you are applying when
planning for the finished rough opening depth if you want
the front panel to be flush with surrounding cabinetry. You
may have to move the unit back into drywall or bring the
cabinets forward to achieve a flush fit. Refer to the
illustrations.
Illustrations on the following pages give dimensions for an
Integrated drawer unit installed within a framed cabinetry
beaded inset application. Review the illustrations, giving
particular attention to the overall panel specifications.
Traditional Frame – standard overlay
(top view).
raditional Frame –
T
3
/8" (10) offset
(top view).
Dimensions in parentheses are in
millimeters unless otherwise specified.
7
Page 8
Planning Information
A) ALL REVEALS ARE 1/8" (3)
B) DRAWER RAILS ARE ATTACHED TO DRAWER FRONTS
C) BOTTOM RAIL MUST BE REMOVABLE
*DIMENSIONS MAY VARY
C
A
A
A
B
B
PANEL WIDTH
11/2"
(38)
FRONT VIEWSIDE VIEW
263/4" (679)
139/16"
(345)
151/16"
(383)
11/2"
(38)
11/2"
(38)
4"*
(102)
4" (102)
341/2"
(876)
*
24"
(610)
27"
(686)
SHADED AREA
INDICATES STATIONARY
STYLES AND RAILS
TOP VIEW
AA
PANEL
CABINET DOOR
TO WALL
SUB-ZERO
UNIT
27"
(686)
24"
(610)
Integrated Model 700BR
FRAMED CABINETRY – BEADED INSET APPLICATION
The illustration shows an Integrated drawer unit
installed within a framed cabinetry beaded inset
application.
IMPORTANT NOTE: Dimensions are based on a 1/8" (3)
reveal. A reveal of up to
d
imensions need to be adjusted accordingly.
1
/4" (6) is possible, but panel
Installation of an Integr
awer unit
ated dr
within framed cabinetry.
*Dimensions may vary.
Dimensions in parentheses are in
millimeter
s unless otherwise specified
8
.
Page 9
A
A
A) ALL REVEALS ARE 1/8" (3)*DIMENSIONS MAY VARY
SIDE VIEW
24"
(610)
PANEL WIDTH
263/4"* (679)
139/16"
(345)
1611/16"*
(424)
4"*
(102)
341/2"
(876)
*
27"
(686)
FINISHED OPENING
TOE KICK
Planning Information
Integrated Model 700BR
FRAMELESS CABINETRY APPLICATIONS
The illustration below shows a hypothetical installation of
an Integrated drawer unit within frameless cabinetry.
Review the illustration, giving particular attention to the
overall panel specifications.
FRAMELESS CABINETRY
IMPORTANT NOTE: Dimensions are based on a 1/8" (3)
r
eveal. A reveal of up to
1
/4"
(6) is possible, but panel
dimensions need to be adjusted accordingly.
awer unit
Installation of an Integr
within frameless cabinetry.
*Dimensions may vary.
Dimensions in parentheses are in
millimeters unless otherwise specified.
ated dr
9
Page 10
Planning Information
T
OP VIEW
CABINETS
25
(
635)
2
7
(686)
CABINETS
25
(
635)
2
7
(
686)
MINIMUM 5/8" (16) SIDE PANELS
TOP VIEW
CABINETS
54
(1372)
25
(635)
CABINETS
25
(635)
2
27
(686)
MINIMUM 5/8" (16) SIDE PANELS
Integrated Model 700BR
Installation without side panels.
INSTALLATION OPTIONS
The illustrations on this page show some typical
installations and their dimension considerations.
The depth dimension in the illustrations may vary
depending on cabinet styles, treatment of countertops or other design options.
IMPORTANT NOTE: The depth of each Integrated
unit is 24" (610) from the front of the unit to its
back. Your design may necessitate moving the unit
back, or cabinets forward to achieve a flush fit. This
will require a minimum rough opening depth of 25"
(635). Refer to the illustrations.
Installation with side panels.
Installation of two units side b
y side
DUAL INSTALLATIONS
If two or more Integrated models are installed side
by side where there is 2" (51) or less of space
between the units, a heater kit is recommended—
BBDUAL for two drawer units installed side by side
or a drawer unit and a tall unit installed side b
y
side. This optional component is available through
your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website,
subzero.com.
.
Installation at end of run.
Dimensions in parentheses are in
millimeters unless otherwise specified.
10
Page 11
Planning Information
10
9
16
(268)
16
11
16
(424)
PANEL
PANEL
10
(254)
4
(102)
OPTIONAL
2
5
8
(67) 4(102)
TO
9
11
16
(246)
1
2
(13)
FLOOR
TO WALL
25
(635)
BASE MOLDING MUST
BE REMOVABLE
Integrated Model 700BR
TOE KICK CLEARANCE
TOE KICK AREA DETAIL
The toe kick clearance can vary with the height of the
1
lower drawer panel; the maximum panel height is 16
1
/16"
(424).
IMPORTANT NOTE: You must keep a minimum space of
4" (102) clear below the bottom edge of the lower drawer
p
anel so the unit can be properly vented. In addition, any
decorative base molding must be removable for possible
servicing and cleaning of the condenser.
The illustration below shows the area below the lower
drawer where the operating mechanical equipment of the
Integrated unit is housed.
IMPORTANT NOTE: The depth of each Integrated unit is
24" (610) from the front of the unit to its back. Your
design may necessitate moving the unit back, or cabinets
forward to achieve a flush fit. This will require a minimum
rough opening depth of 25" (635). Refer to the illustration.
Dimensions in parentheses are in
millimeters unless otherwise specified.
11