Planning Information
All Freezer
odel 601F/F
M
ramed
F
Model 601F/O Overlay
Lighted electronic control panel
Adjustable wire
helves
s
utomatic ice
A
aker
m
ull-out ice
P container
Roll-out storage baskets
Hermetically sealed refrigeration units
Removable kickplate
Serial and model number plate
Front venting allows unit to be completely built in
(Stainless steel design shown )
Adjustable door
helves
s
our-sided
F magnetic gaskets
Door closers
Model 601F/S (P/B) Stainless Steel
The Sub-Zero Model 601F all freezer is available in your choice of the framed, overlay or stainless steel design application. Three stainless steel finishes are offered— classic (/S), platinum (/P) and carbon (/B).
Dimensions in parentheses are in millimeters unless otherwise specified.
11/06
With the installation of a harness kit, these appliances are Star-K compliant to meet strict religious regulations in conjunction with specific instructions found on star-k.org. You may purchase this harness kit through your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com.
Combined with the Model 601R or 601RG this
popular all freezer model strik This combination is formida
es a handsome pose
ble and no one else in the market can boast the performance these two offer. The automatic ice maker has a large storage drawer for easy access to the crescent-shaped ice.
.
1
36"
(914)
24"
(610)
73"
(1854)
36"
(914)
361/16"
(916)
351/4"
(895)
237/8"
(606)
BEHIND
FRAME
3
/8" (10)
FRAME
EXTENSION
Planning Information
FEATURES
36" (914) wide all freezer
S
ub-Zero's refrigeration system ensures the
best storage and energy efficiency
Shallow-depth design means access is easy to any area of the freezer
Electronic digital controls are up front and easy to use
Bright interior lighting
Adjustable wire shelves
Door alarm will let you know with an audible beeping if your freezer door is left ajar
Automatic ice maker provides an ample supply of crescent-shaped ice
Front venting allows unit to be completely built in and serviced from the front
Meets strict Department of Energy require­ments
UL approved for US and Canada
Two, five and twelve year residential warranty – exclusions apply; warranty information can be found on our website, subzero.com
OVERALL DIMENSIONS
Stainless steel design shown.
1
±
y
ary b
Dimensions ma
Dimensions in parentheses are in millimeters unless otherwise specified.
y v
/8" (3).
2
Planning Information
SPECIFICATIONS
M
odel 601F All Freezer
Overall Width 36" (914)
Overall Height 73" (1854)
MODEL OPTIONS
Framed Design 601F/F
Overlay Design 601F/O
Classic Stainless Steel 601F/S
Platinum Stainless Steel 601F/P
Carbon Stainless Steel 601F/B
ou must allow 90 days from order to
Y delivery for platinum and carbon finishes.
A CCESSORIES
Front panels for framed design in white, almond and classic stainless steel
Side panels in white, almond and classic stainless steel
Extended framed handle
Stainless steel and polished chrome handles for overlay design
90˚ and 105˚ door stop kits
Accessories are av Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com.
ailable through your
Overall Depth 24" (610)
Freezer Capacity 19.3 cu ft (547 L)
M
inimum Height (levelers in) 72
3
/4"
(1848)
Door Swing Clearance 361/16" (916)
Electrical Requirements 115 V AC, 60 Hz, 15 amp circuit
Plumbing Requirements
ater Supply 20–100 psi
W
1
/4" copper line
Annual Energy Usage 737 kWh / $ 67 (based on 9.06 cents per kilowatt hour)
Shipping Weight Framed – 378 lbs (171 kg)
Overlay – 378 lbs (171 kg)
Stainless Steel – 406 lbs (184 kg)
Specifications are subject to change without notice.
Dimensions in parentheses are in millimeters unless otherwise specified.
3
Planning Information
723/4"
(
1848)
ROUGH
OPENING
HEIGHT
351/2"
(902)
ROUGH OPENING WIDTH
24"
(
610)
R
OUGH
O
PENING
D
EPTH
11"
(279)
3"
(76)
24"
(610)
W
LOCATE WATER SUPPLY
WITHIN BOTTOM SHADED
AREA ONLY
LOCATE ELECTRICAL
WITHIN ENTIRE SHADED AREA
6"
(152)
E
SHUT-OFF
VALVE
E
XTEND WATER LINE
A
PPROX. 36" (914)
F
ROM BACK WALL
FRONT VIEW
TOP VIEW
INSTALLATION SPECIFICATIONS
DIMENSIONS
Finished Rough Opening Width 351/2" (902)
Finished Rough Opening Height 723/4" (1848)
Finished Rough Opening Depth 24" (610)
Location of Electrical Within entire shaded area
Location of W
See Installation Instructions shipped with unit for detailed specifications. Refer to the Sub-Zero Design Guide pdf file for additional specifications.
Dimensions in parentheses are in millimeters unless otherwise specified.
ater Supply
Within lower shaded area
4
Planning Information
INSTALLATION NOTES
R
efer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics.
A
llow the door to open a minimum of 90˚ or you'll have problems removing drawers. With the door opening at 90˚, you may have to move drawers slightly to clear the door interior. Refer to the minimum door swing clearance in the specifications chart.
For corner installations, allow for a minimum 3" (76) filler so that the door can open to 90˚. If you're using raised panels, consider using a wider filler. A 90˚ door stop is available as an accessory.
When units are installed side by side, a filler strip is recommended. The width of this filler strip will vary depending on the configuration and panels you use. An anchoring kit may also be used to attach two units together. This kit is available through your Sub-Zero dealer.
Be sure to add the filler strip width to your finished rough opening dimension. In any side­by-side installation without a filler strip, add an additional This will allow for the proper width.
Refer to the full-scale illustrations at the end of this section for specifics on door openings and filler size alternatives.
If your client has chosen the stainless steel design, the unit will be shipped complete with wrapped stainless steel doors and handle hardware. You will not have to install front panels.
If y overlay design, you will be adding front panels to give the unit the custom Sub-Zero look. The overlay design also allows you to add your own handles, or you may choose accessory handles
ailable through your Sub-Zero dealer. Refer to
av pages panels.
F maker, rough in the water supply line. Connect
1
a
/4" OD copper line to the house supply sure to use an easily accessible shut off valve between the supply and the unit.
1
/2" (13) to y
our client has chosen the fr
10 for detailed information on adding
6
our combined number
amed or
s.
or Built-In models with an automatic ice
, being
D
o not use self-piercing valves. A saddle valve kit (4200880) is available from your Sub-Zero dealer. To obtain local dealer informa­tion, visit the Locator section of our website, s
ubzero.com.
A line filter is required when water condi­tions have a high sediment content. The ice maker operates on water pressure of 20 psi (1.4 bar) to 100 psi (6.9 bar). In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently.
The water line should be routed up through
1
the floor within
/2" (13) from the back wall and no higher than 3" (76) off the floor. If you have to come through the wall, make sure the water line is no more than 3" (76) fr
om the floor. Locate water supply within the lower shaded area shown in the installation illustration.
Regardless of the routing, allow 3' (.9 m) of excess copper tubing to remain outside the wall or floor for easy connection to the unit.
A 115 v
olt, 60 Hz, 15 amp electrical supply is required. The supply circuit for this appliance must be pr
otected by a 15 amp fuse or circuit breaker. It is recommended that a separate circuit, serving only this appliance, be provided.
All Built-In models are equipped with a 6' (1.8 m) power supply cord with a 3-prong grounding plug which must be plugged into a mating 3-prong grounding type wall receptacle. Locate electrical within the shaded area shown in the installation illustration.
ou must follow all National Electrical Code
Y regulations. In addition, be aware of local codes and ordinances when installing your service.
To prevent the unit from tipping forward and
ovide a stable installation, the unit must be
pr secured in place with an anti-tip bloc
king kit. If there is a solid soffit above the unit with clear­ance between the unit and the soffit of 1" (25) or less, y
ou won't need to bloc
or installations with clear
F
k the unit.
ances of more than 1" (25), you must block the unit with the anti-tip blocking kit (wood block and hardware) provided with each Built-In unit.
Refer to the Built-In Installation Instructions
ed with the a
k
pac
ppliance
, which pr
ovides step-by-step procedures for making sure the unit is installed properly.
Dimensions in parentheses are in millimeters unless otherwise specified.
5
Planning Information
ADDING PANELS
In your plan for panels, be sure you are working with the Sub-Zero panel design family called for in your design. If you have chosen the stainless steel design, the unit will be shipped complete with wrapped stainless steel doors and h
andle hardware. You will not have to install front door
panels.
If you and your client have ordered a framed or overlay design model, you will be adding panels to give the unit the custom Sub-Zero look. Specifications on the following pages provide installation considerations for framed and overlay door panels.
Side panels can be used with the framed, overlay and stainless steel design applications. Refer to specifications on page 10.
Dimensions in parentheses are in millimeters unless otherwise specified.
6
Planning Information
PANELS
1
/4" (6) THICK OR LESS
1
/4" (6) Panel
Trim reveal
1
/4" (6) min
PANELS THICKER THAN
1
/4" (6)
Trim reveal
1
/4" (6) min
Rout to 1/4" (6)
thickness
W
H
A
14" (356)
FRAMED PANELS
Framed door panel 1/4" (6) thick or less
FRAMED PANELS
If the thickness of the custom panels is less than 1/4" (6), they must be backed up with a sheet of shim material to build the total thickness to
1
than
/4" (6), an edge must be routed around the panel to
1
/4" (6). If the panel is thicker
ensure a proper fit. Refer to the illustrations on this page.
I
MPORTANT NOTE:Routing, recessing or optional
extended handles may be required on raised panels for finger clearance under the handle. Refer to the full-scale illustrations on pages 11– 14.
IMPORTANT NOTE: The weight of each panel cannot exceed 50 lbs (23 kg).
The traditional framed models come with an 11" (279) louvered grille and elegant full-length handle. Optional extended full-length handles that provide additional finger clearance for raised panels are available through your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website
, subzero.com.
Framed door panel thicker than 1/4" (6)
To install framed panels, refer to the installation instruc­tions shipped with each unit
. These instructions can also
be found on our website, subzero.com.
FRAMED PANEL DIMENSIONS
WIDTH HEIGHT
Door Panel 341/8" (867) 5815/16"(1497)
Handle Recess Location A – 2915/32" (749)
Maximum Panel Weight 50 lbs (23 kg)
Framed Door Panel
Dimensions in parentheses are in millimeters unless otherwise specified.
7
Planning Information
Door/Drawer /
Grille Trim
1
/16" (2)
5
/32" (4)
1
/4" (6) Backer Panel
5
/16" (8) min
.
10"
(3)
Spacer Panel
Overlay Panel
Spacer Panel
Overlay Panel
1
/4" (6)
Backer
Panel
.10"
(3)
~3/4"
(19)
OVERLAY PANELS
OVERLAY PANELS
The overlay design allows decorative panels to cover the door trim for a more seamless appearance that blends with the design of the room. To achieve this look, the most common way is to work with three panels—the decorative overlay panel, a .10" (3) spacer panel and a
1
/4" (6) backer panel. Depending on your cabinet manufacturer, this could be one panel routed for different dimensions or more likely, three different panels.
Regardless of the physical construction of the panels (routing or three panel assembly), you will need to follow the exact dimensions and panel placement to ensure a proper fit.
The top illustration on this page is a cross section view of the three panel assembly showing placement of the door / drawer / grille trim. The bottom illustration shows a rear view of the three panel assembly and critical dimen­sions, standard for all overlay models.
Three panel assembly— cross section
Three panel assembl
y— rear view
Overlay models will come with no handle hardware, because the beauty of this design is that you can match the surr
ounding cabinetry hardware. For overlay door panel
dimensions, refer to specifications on page 9.
IMPOR
TANT NOTE:
Keep in mind that the Sub-Zer
o door panels have the potential for hitting adjacent cabinets and/ or countertops when they are opened. You need to be
are of your surrounding cabinetry and space limitations
aw when using the overlay models. Refer to the full-scale illustrations on pages 13 –14.
IMPORTANT NOTE: The weight of each door panel assembly cannot exceed 50 lbs (23 kg). The total thick­ness of all panels for an overlay model must be at least
5
/8" (16) thick.
To install overlay panels, refer to the installation instruc­tions shipped with each unit
. These instructions can also
be found on our website, subzero.com.
Dimensions in parentheses are in millimeters unless otherwise specified.
8
Planning Information
W
H
Overlay Door Panel
OVERLAY PANELS
OVERLAY PANEL DIMENSIONS
WIDTH HEIGHT
Door Panel 347/16" (875) 591/4" (1505)
Door Spacer 331/2" (851) 585/16" (1481)
5
Door Backer 341/8" (867) 58
1
/16"(1497)
Maximum Weight (panel assembly) 50 lbs (23 kg)
Dimensions in parentheses are in millimeters unless otherwise specified.
9
Planning Information
4"
(102)
3" (76)
237/8" (
606)
B
EHIND FRAME
SIDE PANELS
SIDE PANELS
Side panels can be used with the framed, overlay and stainless steel design applications. When planning for side panels with the installation of the Built-In model, you need to be aware of space configuration to achieve a pleasing fit. Depending on the exact panel you are using with your unit, the height of the panel will vary.
Cut-outs around the toe kick and grille area are required if
1
a
/4" (6) thick panel will be inserted into the main frame channel. The panel will need to be 24" (610) deep. Refer to the illustration on this page for placement of toe kick and grille area cut-outs. If a panel will abut the main frame and should be 23
3
/8" (10) thick panel is used, the
7
/8" (606) deep. The toe kick area may or may not be cut out depending on the look you want to achieve.
IMPORTANT NOTE: The use of side panels may change the width of your rough opening.
Cut-outs for grille and toe kick area
HARDWARE CONSIDERATIONS
Overlay models come without handle hardware. The beauty of this design is that you can match the surround­ing cabinet hardware. You or the cabinet manufacturer must provide handle hardware to match the overall deco­rating scheme.
The handle hardware must be installed before installing the panel assembly. Use larger D-style handles. If screws with thick heads are used, the screws will need to be countersunk into the door before the panel is put into
. Refer to the full-scale illustr
place
ations on pages 1
1–12
for handle hardware considerations.
IMPORTANT NOTE: Sub-Zero does not recommend using single pull knobs on any of its Built-In models.
Optional stainless steel handles are available in a variety of diameter
s and lengths in the classic, platinum and carbon stainless steel finishes and polished chrome. Contact your Sub-Zero dealer for specifics. To obtain local dealer information, visit the Locator section of our website,
o.com.
subzer
Dimensions in parentheses are in millimeters unless otherwise specified.
10
Planning Information
11/4"(
32) PANEL
1"(25) PANEL
1
/4"(6) P
ANEL
1
/2"(13) PANEL
3
/4"(19) PANEL
O
PTIONAL
EXTENDED
FULL-LENGTH
HANDLE
S
TANDARD
FULL-LENGTH
HANDLE
DOOR
1
/4"(
6)
FRAMED PANEL
1"
(25)
2"
(
51)
3"
(
76)
HANDLE PROFILE – FRAMED APPLICATION
FULL-SCALE TEMPLATES
The following full-scale illustrations enable you to under
stand some of the unique situations you may face as you design the Built-In units into homes. These templates can be easily photocopied or used in y
Dimensions in parentheses are in millimeters unless otherwise specified.
our tr
acings.
HANDLE PROFILE
The full-scale illustration above shows handle placement for the fr
amed a
pplication standard full-length handle and the optional extended full-length handle shown in the dashed line.
11
Planning Information
11/4" (32) PANEL
1" (25) PANEL
1
/4" (
6) PANEL
1
/2" (
13) PANEL
3
/4" (19) PANEL
5
/8" (16) PANEL
DOOR
1
/4" (
6)
APPROXIMATE THICKNESS OF WRAPPED STAINLESS STEEL DOOR
NOTE: FOR OVERLAY APPLICATIONS, OPTIONAL STAINLESS STEEL HANDLE
MUST BE MOUNTED ON PANEL MINIMUM 5/8" (16) THICK.
1"
2"
(
51)
3"
(
76)
S
TANDARD STAINLESS STEEL HANDLE
HANDLE PROFILE – STAINLESS STEEL / OVERLAY APPLICATIONS
PANEL AND HANDLE PROFILE
The full-scale illustr placement for the standard stainless steel
ation a
bove shows handle
handle on the wrapped stainless steel door and on overla dashed line
y panel applications shown in the
.
IMPORTANT NOTE: For overlay applications, the optional stainless steel handle must be mounted on a panel at least
5
/8" (16) thick.
For overlay applications, mount door handles close to the opening edge of the door for ease of opening
.
Dimensions in parentheses are in millimeters unless otherwise specified.
12
1
1
/
4
"
(32)
PA N
EL
1"
(25)
PA N
EL
*
1
/
4
"
(6)
PA N
EL
1
/
2
"
(13)
PA N
EL
3
/
4
"
(19)
PA N
EL
130˚ DOOR OPENING
WITH 2" (51) FILLER STRIP
(
TOP VIEW)
OPTIONAL
FRAMED EXTENDED
FULL-LENGTH HANDLE
STANDARD
FRAMED
FULL-LENGTH
HANDLE
D
OOR CLOSED
DOOR OPEN @ 130˚
HINGE
2" (51)
F
ILLER STRIP
MAIN FRAME
A
LLOW FOR FILLER LAP
BEHIND FLANGE
APPROX
PROFILE OF
STAINLESS STEEL DOOR AND HANDLE
OVERLAY PANEL
3/4" (19) THICK
(NOMINAL)
S
UB-ZERO UNITSUB-ZERO UNIT
Planning Information
PANEL AND HANDLE PROFILE – 130˚ DOOR OPENING
The full-scale illustration above shows the panel and handle profile of a 130˚ door opening with 2" (51) filler strip for framed applications.
Interference of door panels with handles at maximum door s optional 90˚ door stop available through your Sub-Zero dealer.
Appr
* stainless steel door
Dimensions in parentheses are in millimeters unless otherwise specified.
oximate thic
wing ma
y require the use of an
kness of wr
.
pped
a
To obtain local dealer information, visit the Locator section of our website, subzero.com.
The full-scale illustration on the following page lets you see what considerations you need to
e for any overla
mak how they may interact with adjacent cabinets
y panel applications, and
and/ or countertops.
13
Planning Information
1
1
/4
"
(32)
PA N
EL
1"
(25)
PA N
EL
*
1
/4
"
(6)
PA N
EL
1
/2
"
(13)
PA N
EL
3
/4
"
(19)
PA N
EL
1
1
/4
"
(32)
1
1
/2
"
(38)
1
3
/4
"
(44)
0"
(0)
1"
(25)
2"
(51)
2
1
/4
"
(57)
2
1
/
2
"
(63)
2
3
/
4
"
(70)
3"
(76)
3
1
/4
"
(83)
3
1
/
2
"
(89)
1
/4
"
(6)
1
/2
"
(25)
3
/4
"
(19)
HINGE
OVERLAY PANEL
3/4" (19) THICK (NOMINAL)
DOOR CLOSED
DOOR OPEN @ 90˚
90˚ DOOR OPENING
(TOP VIEW)
M
AIN FRAME
NOMINAL OVERALL
WIDTH OF SUB-ZERO
S
UB-ZERO UNIT
237/8" (606) TO REAR
O
F SUB-ZERO
OVERLAY PANEL APPLICATION – 90˚ DOOR OPENING
kness of wr
.
oximate thic
Appr
* stainless steel door
Dimensions in parentheses are in
pped
a
millimeters unless otherwise specified.
14
Loading...