Subaru Robin Power Products RGX405, RGX305, RGX405D, RGX305D, RGX505 User Manual

...
Generator
Model
RGX305,305D RGX405,405D RGX505,505 D
Technical Data & Overhaul Instructions
CONTENTS
Section
Title Page
1. SPECIFICATIONS
..........................................
1
2. PERFORMANCE
...........................................
3
2-1
Model RGX305
......................................
3
2-2
Model RGX305D
.....................................
4
2-3
Model RGX405
......................................
5
2-4
Model RGX405D
.....................................
6
2-5
Model RGX505
......................................
7
2-6
Model RGX505D
.....................................
8
3. FEATURES
..............................................
9
4. GENERAL DESCRIPTION of GENERATOR
........................
11
4 - 1
External View of Generator
..............................
11
4-2 Panel A
............................................
12
4-3 Panel B
............................................
13
5. CONSTRUCTION and FUNCTION
...............................
14
5-1
Construction
........................................
14
5-2 Function ...........................................
15
5-3
Description of Generator Operation
.........................
21
5-4
Change of Engine Parts
.................................
25
6. SAFETY PRECAUTION
......................................
28
7. APPLICABLE RANGE of GENERATOR
...........................
29
8. MEASURING PROCEDURE
...................................
32
8-1
Meters ............................................
32
8-2
AC Output Measuring
..................................
34
8-3
DC Output Measuring
..................................
34
8-4
Insulation Resistance Measuring
...........................
34
9. CHECKING FUNCTIONAL MEMBERS.
...........................
36
9 - 1
Stator Assembly
......................................
36
9-2
Rotor Assembly
......................................
37
9-3
Brushes. ...........................................
38
9-4
AVR (Automatic Voltage Regulator)
........................
38
9-5
No-Fuse Breaker and Fuse Holder
..........................
40
9-6
Receptacle and AC Plug
.................................
41
9-7
Voltmeters
.........................................
41
9-8
Diode Stack Assembly
..................................
41
9-9
Primary Exciting Circuit
................................
42
10. DISASSEMBLY and REASSEMBLY
..............................
43
10 - 1
Preparations and Suggestions
.............................
43
10-2
How to Disassemble
...................................
43
10-3
How to Reassemble.
...................................
51
10-4
Control Box Disassembly and Reassembly
.....................
58
11. TROUBLE-SHOOTING
.......................................
59
12. OPTlON
.................................................
63
12 - 1
Electric Starter.
......................................
63
12-2 Caster
.............................................
68
13. CIRCUIT DIAGRAM
........................................
69
T
.-
Model
- .- _-
Type
RGX305 RGX305D
RGX405 RGX406D
_-.. --- .-.... - __.-. ._ _ _-. _- --__. -- __-- - -. - .._-
Revolving-Field, Self-Exciting, P-pole, Single Phase
_--.. .-
Frequency
-. -_... _-
50Hz 60Hr
.-__ __ _.-.
3ooow 3400w 2500W 2900w
.-- --
50Hr
.- .._
4ooow 3300w
- _-.-.
60HZ
-.-­4400w
3700w
-.. .- _ __
50Hz
.__ _
._ ._-
3ooow 2500W
- - -.. .._. .
Z ‘XA
.-..
‘Z 2oZA
-- ..- - ._ _
__-.- -
50Hz
- - .-­4ooow
3300w
1lOV
/
22OV
120v
/
240V
_ I----
53.6A
/
16.8A
,--.
30.8A
/
15.4A
-- .-
i
1lOV
/
220v
12ov
/
240V
30.OA
/
15.OA
26.4A
.-._
24.2A
-
-
.-
-
-,- I.
Power Factor
.-.-_. -.
DC output
- _---. -.
5 2 E
;
-.
ii G
L
W
._--.-
27.5A
/
13.8A
.,-_.
I---’
240V 13.8A
I
- I --
. I. -
-A .- -- 1 -. .-.
1 .o
-
.-
_ _..-. . ..-
.- _-
-
_.. -- -.
12V 8.3A 1OOW
..-_
_-. ._ - - ..-. -, ., .-
AVR (Automatic Voltage Regulator)
.- .- --.- -- .-.. .-_ _-. ._ -. ._--_. _-. -
Within 3%
.-. -.
_.
--. --- _
7
-
Voltage Regulator
--- -.
Voltage Regulation
--. . .,. ._- . -- ._
Tw
-.. .- _.
Model
- -__-, _.- -­Displacement
_ .-
_--
Max. Output
-. -_, Fuel
_ -__. ..-
Fuel Tank Capacity
-. ._. Oil Capacity
,,.. .- . - ._- .-
Revolutions/min _ ._- . - -
lgntition System
_....- -
Starting System
_____ _ . _ ._
Fuel Consumption Ratio
..-. -
.-_
Irry Weight
.-. .- - ..- ._ -
.- --
--_ ..- -_. _- ..-_.. _- _ _ __-_ .
Robin Air-Cooled, 4.Cycle Gasoline Engine
. ..- --- ._-. . . - - -_. _- ~._ _--
EY25-2D(EY26-WI”
-..- ._ -. ._. ____. __ --­252 cc (15.40 cu. in)
_- - _-.
,... _-
7HPl4000 rpm
._-_,. _ ___-
7
_- ---- . .._--- -
EY35DIWl-340)”
- -- ,.. - _. -_- __.. __ _. __ - _ 334 cc (20.39 cu. in)
.--- _._ .-
-. ..-.
8.5HP13600 rpm
- _--_-,., - .- ..- _. .._ - _-.. . ._. .---. . ___. . -
Automobile Gasoline
-
_ _- .- -_ -. _ .-_. ___
._-
.- -
16 Liters (4.2 U.S. gall
__ _. .--. - --..
I
_ ..-. .
._.
.-- __--- - ..-.-
0.85 Liter (1.8 pints)
1.2 liters (2.6 pints)
-
_- .-. .- __- . - - _- _ _ _-_
.- ..-- -
50Hz-3000 rpm, 6OHr-3600 rpm
-- - __,. _-. -_
.-- ._., ._-__, .- -. --- -., _..--- ..-. - _ ._ ._.- ._---
Robin Solid State Ignition Svstem
._-., _ .-_ .-.
_- ..-__ .--.__
-... -
.--.. ___.. .___ . -.. -
Recoil Starter (Electric Starter Optional)
- -. ._
--. ..-. .- _-..
- _..-- .--. _- . -._ _.
1.7 Liters/Hr f50Hz), 1.9 Liters (60HzJ
2.2 LiterslHr f50Hz). 2.6 LiterslHr f60Hz)
.-- -...- _-. _.-.. I -_
_
.--.. ---
681 mm (26.8 in)
706 mm 127.8 in)
.-- .__.. _..- - _. ___
~-- . .
_
466 mm (18.3 in)
486 mm (19.1 in)
-. - . _. .- .
.-. .-.. _.-. .- ..--. -- . _-. . . .
661 mm (22.1 in)
596 mm (23.5 in)
.--.. . . ..- _-- - _._-.
_-.
62 kg (137 Ibs)
73.5 kg (162 Ibs.)
_.
“For U.S.A. and Canadian markets
I
h)
I
Model
Type
RGXSOB
RGX505D I I
Revolving-Field, Self Exciting, 2-pole, Single Phase
.
5
t 2 5
c)
-
; z
w
- -.
,._. _- - -_ _ -_ ___, _
50Hz
-
Max. 5ooOW Rated
4400w
I
Power Factor
I
.--_
6OHZ
_--
5500w 4800W
1oov
/
220v
-­120
/
240V
- . . 1 .o
- _- ----. --_. _. _-
-. ---- _
DC Output
12V 8.3A 1OOW
- .-.__---...-- -- -
-. -_-_ _.- .-__- - _ - --_ __ -___.__ __
Voltage Regulator
AVR (Automatic Voltage Regulator)
-~. _ -. -.-._- .-_- -_- --_, _
Voltage Regulation
Within 3%
-.- - .---- I--
- .---- - ._ -. ..- .- __.___- --__---
Type
Robin Air-Cooled, 4-Cycle Gasoline Engine
-. - _ - - ---
- .-. ____m
Model
-. - .- (Wl-350); EY40D
-. - .---.. - -
- - .--_-
-.-- ,... - .- -. - _._____
--
Displacement
388 cc (23.68 cu. in)
- --. -
-
.---.-, - - ,.- .-..--
..-. - ,.- _
Max. Output
lO.OHPl3600 rpm
_.-- -. -._ _.
.-, - .- --.--- --.
Fuel
Automobile Gasoline
.--. .-,-.
.- -.--- ..- ---
- .-. -._
Fuel Tank Capacity 16 liters (4.2 U.S. gal)
- -.-.. --
-. .- -
__ _- .___
Oil Capacity 1.2 liters (2.6 pints)
--. .__- . . -.
-._____ __ _
.-- .,----.
_, _ ._
Revolutionlmin
50Hz-.3000 rpm, 60Hz-3600 rpm
- ___.
.-- __
..-- .-._ - . -- .--.
. -
_- __. _. _-__
Ignition System
Robein Solid State Ignition System
Starting System
Recoil Starter (Electric Starter Optional)
- ----
-. ,---.-
-
---._ ----
--.
-... -..
-
.- .- -._-
Fuel Consumption Ratio 2.7 Liters/Hr (5OHr). 3.1 LiterslHr f60Hz)
-- _-
-. __-
. -.. _- ._
___ ,__ ,--.- ---_
_- .-
-- ._-
Length 706 mm (27.8 in)
-
-. .-.-
-.--_._
-, -.-.-
Iimensions
Width
488 mm (19.1 in)
-, --_.-.-.--.
,.
Height 596 mm (23.5 in)
-.
---_._- -
.---. ----
Dry Weight
77.5 kg (171 lb.?.)
--
l Enr I I C A snrl Panarlisn marLate

2. PERFORMANCE

2-l OUTPUT MODEL RGX305.
Type . . . . . . . . . . . . . . . Self Exciting, 2-Pole, Single Phase
Power Factor . . . . . . . . . . 1 .O
Engine . . . . . . . . . . . . . . EY25-2D(EY25WI*
t
63 ‘; 1;;62 ,t z 61 2 60
2 59
7
$20 ;;llO %O
5 :
12
16 20 24 28 32
CURRENT(A) -
2
4 6 8 10 12
14
CURRENT(A) -
2
4 6 8 10 12
CURRENT(A)-
3
-- 2500 5 e
0’
.- 2000
-.1500
T
1500 t
:
1000
. . 3000
Output Max.
...............
3400W
Rated ..............
2900W
Frequency
.................
60Hz
Voltage
...................
11ov
Output Max.
...............
3000W
Rated ..............
2500W
Frequency
................. 5OHZ
Voltage
................... 220v
Output Max.
...............
3000W
Rated ..............
2500W
Frequency
................. 5OHZ
Voltage.
..................
240V
0’
bOo
NOTE: These diagmms show the RGX305 characteristics at
I
the main line frequencies and voltages. The characteristics
+
1000
are similar to 6OHz 12OV, 5OHz 1 lOV, and 5OHz 230V.
*For U.S.A. and Canadian markets
-3-
MODEL RGX305D Type
...............
Self Exciting, 2-Pole, Single Phase
Power Factor
..........
1 .O
Engine
..............
EY25-2D (EY25W)”
t
OUTPUT(240V).
OUTPUT (12OV1
250
240 2230 ti d 630 > 120
110
0
5
10
15
20
25
30
CURRENT(A)-
0 5
10
15 20
25 30
---I= I
‘n, A,, :rr&n\;\
I (11OV)
CURRENT(A)-
I
3000
t2500
1
t
: 2000
iii
I
!T
I k
1
‘1500 2
hO0
-c
500
Output Max.
...............
3400W
Rated
..............
2900W
Frequency
.................
6OHZ
Voltage
................
12OVl24OV
I
I
3000
Output Max. . . . . . . . . . . . . . . . 3000W
Rated . . . . . . . . . . . . . . 2500W
Frequency . . . . . . . . . . . . . . . . .
5OHZ
-,2500 t
Voltage . . . . . . . . . . . . . . . . 11 OV/22OV
/E
-,2000 2 5
1
0
1500
NOTE: These diagrams
show the RGX305D characteristics
at the main line frequencies and voltages The characteristics are similar ro 6OHz 1 IOVB?OV, 6OHz 12OVR4OV.
“For U.S.A. and Canadian markets
-
A-
MODEL RGX405 Type
...............
Power Factor ..........
Engine ..............
Self Exciting, 2-Pole, Single Phase
1.0 EY35D(Wl-340)*
I
120 ZllO $00
2
G
CURRENT(A) -
<220-
I I/.
w210-
j , I y :
I
g200* i i I I/: i
i
i
I
I I
‘J 2
Y I
2 4 6 8
i I I
lo 12 14 16 18
CURRENT(A)-
I
i 53 >­0 2 52
Z­5 51
g 50 a
u.
49
-240 f
2
4 6 8 10 12 14 16
18
?4500
Output Max.
...............
44OOW
Rated
..............
3700W
I
iNo”4
Frequency
.................
60Hz
Voltage
...................
11ov
+4000
13500
I
:3OOoj
Output Max.
...............
4000W
Rated
..............
3300W
Frequency .................
50Hz 220v
Voltage ...................
i’”
2
i
1500
44000
Output Max.
...............
4000W
Rated ..............
3300W
Frequency
.................
50Hz
Voltage
...................
240V
t
2000
NOTE: mesa diagrams show tie RGX405 characteristics at
+
1500
tie main line frequencies and voltages. The characteristics
are similar to 6OHz 12OV, 5OHz 1 lOV, and 5OHz 230 V.
*For U.S.A. and Canadian markets
CURRENT(A)-
-5-

MODEL RGX405D

Type ...............
Power Factor ..........
Engine ..............
Self Exciting, 2-Pole, Single Phase
1.0
EY35D (Wl-340)’
--
62
61
60
59
f 240 250
5: z 230
0 2
J z 130
120
i :
j
0 5 10
15 20
25
30 35 40
CURRENT(A)-
2 52 5 51
$50
2 49
2
1230
I
220
Output Max. .
Rated
Frequency. . .
i--i
Voltage . . . . .
s
I
3000 5
e
2000
s
t
1000
..............
4400W
..............
3700w
..............
6OHZ
...........
12OV/24OV
Output Max. . . . . . . . . . . . . . . . 4000W
Rated . . . . . . . . . . . . . . 3300W
Frequency. . . . . . . . . . . . . . . . .
5OHZ
I
Voltage . . . . . . . . . . . . . . . . 11 OVl22OV
0
7
-2
t
5
0
2m
NOTE: These diagrams show the RGX405D characteristi
at the main line frequencies and voltages. The characterisri
CURRENT(A)-
ara similar to 6OHz I lOVR2OV, 5OHz 12OVR4OV.
“For U.S.A. and Canadian markets
-6-
Self Exciting, 2-Pole, Single Phase
1.0 EY40D(Wl-390)”
MODEL RGX505 Type
...............
Power Factor
..........
Engine
..............
I I
;; ;; 62 62 E E
> 6’ > 6’
+3 +3
p p
a a
L L
t t 110 120 110 120
F F ;;;loo ;;;lOO
0 0
2 2
i I 1 ] 11 ! i
0 0 10 10 20 20 30 30 40 40
50 50
CURRENT(A) -
1
230
I , t / ,
i/ ’
1
I
220
I ,< !
--V_OLTAGE (
:
7
0
5 10 15
20 25
CURRENT(AI-
A
; 53 3
t 52 2” 51
2 0 50
g 49
u.
1 250
5240 ‘3
13 230 2
0
5 10 15
20 25
I
t
5000
Output Max. ............... 5500W
Rated .............. 4800W
-~I I
z
..3000 5
k
Frequency . . . . . . . . . . . . . . . . .
60Hz
Voltage . . . . . . . . . . . . . . . . . . .
1lOV
-5000
::I
s:
3000 5
e
e.2000 2
Output Max. . . . . . . . . . . . . . . . 5000W
Rated . . . . . . . . . . . . . . 4400W
Frequency . . . . . . . . . . . . . . . . .
5OHZ
Voltage . . . . . . . . _ . . . . . . . . . .
220v
‘1000
t
Output Max. ............... 5000W
Rated .............. 4400W
Frequency ................. 5OHZ
Voltage ................... 240V
1000
I
NOTE: These diagmms show the RGX505 characteristics at
the main line frequencies and voltages me characteristics
are similar to 6OHz 12OV, 5OHz 7 lOV, and 5OHz 23OV.
*For U.S.A. and Canadian markets
CURRENT(A)-
MODEL RGX505D Type
............... Self Exciting, 2-Pole, Single Phase
Power Factor
..........
1.0
Engine
..............
EY40D (Wl-390)*
t sak,l ~rl?rv%!-kUT-I
11 i VI>
.--
240
z 230 ;
2 130 g 120
110
0
10 20 30 40
CURRENT(A) -
t
230 220
z 210 ti
2 120 $110
100
I
i/I a.11
III”’
ijII
;i:i
0 10 20
30 40
50
CURRENT (A) -
1
5000
I
f4000
bo00
-*2000
-~looo
t
5000
t-
i I
]
2
3000 5
“c
2000 0’
Output Max. ............... 5500W
Rated .............. 48OOw
Frequency .................
60Hz
Voltage ................ 12OVl24OV
Output Max.
............... 5000W
Rated .............. 4400W
Frequency .................
5OHZ
Voltage
................
11 OVl22OV
t
1000
NOTE: These diagmms show tie RGX505D characteristics at tie main line frequencies and voltages. The characteristics are similar to 6OHz 1 lOVL22OV, 5OHz 12OVR4OV.
“For U.S.A. and Canadian markets
-8-

3. FEATURES

1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Lightweight, Compact The Robin engine and revolving field generator designs provide added output power per weight and economical opera­tion. Centralized Control The switches, meters, and receptacles are located together on a large-sized control box, and all operating controls are located on top of the engine for easy generator operation. Large 16-Liter Gas Tank
* 16-liter (4.2-gallon) fuel tank is provided for ten hours of operation for Model RGX305 or seven hours for Model
RGX405. (at the 50Hz rated output power) *RGX505 can operate for six hours (at the 5OHz rated output power) with a full tank. *The tank has a fuel gauge which shows the remaining amount of fuel in the tank.
Solid State Ignition System
*Unlike the point system, the solid state ignition system has no contact points so that maintenance due to point wear
is unnecessary and constant output power can be maintained for long.
*Increased spark energy makes starting easy.
Extra-Quiet Operation
*All models are equipped with a large-sized, low-noise muffler. *All models have a cyclone type air cleaner of a low-noise, dustproof type. Small Voltage Fluctuations by AVR (Automatic Voltage Regulator) The automatic voltage regulator automatically adjusts the exciting current to hold voltage regulation down to less than
3%. This helps prolong product life without damaging the electric devices.
DC Output for Battery Charging The generator can generate a DC output (12V, 1OOW) while generating an AC output so that batteries can be charged during AC operation. In this case, make sure that the total AC and DC output does not exceed the rated output.
Full Power Switch me dual voltage type has a full power switch as a standard component. The rated output can be generated at both
12OV (11 OV) and 240V (22OV). Output Voltage Waveform Close to Sine Wave
The output voltage waveform is close to a sine wave and is free of surges so that the load will not be damaged. Resistant to Inductive Load Exciting power is obtained from the sub coil which is wound apart from the main coil. This means less output voltage fluctuations against load variation, and thus a steady level of power. This feature is effective particularly for induction motors, for example, which are subject to sharp current variation.
100% Copper Windings The windings are made only of copper having low internal resistance. This feature also helps improve generator effi­ciency and prolong generator life.
Easy Starting with Recoil Starter
No-Fuse Breaker for Troublefree Operation
-9-
14.
Ruggedly Built Frame The box type frame is so ruggedly built that two or more generators can be stacked. Another convenient feature for the Robin generators.
15. Wide Range of Options The elctric starter type, wheels, and econo-throttle are availabe as options.
-10-
OIL GAUGE
FUEL GAU/GE and TANK CAP
SPARK PLUG CAP
SPEED CONTROL
CHOKE LEVER
\
STOP BUTTON
I
P L
s1 2
5) E
< ii z
3, G)
s am 4; si
I
FUEL STRAINER
I
AIR CLEANER
I
RECOIL STARTER
I
CONTROL BOX
FUEL COCK MUFFLER RECOIL STARTER HANDLE
P t)
?s E
r u
m t?
7[1 G i
i2 0
2 z” i 3 si

4-2 PANEL A

‘0
f
CAC V
AC
RECEPTACLE 1
VOLTMETER NO-FUSE BREAKER
0
OAC V
-n -I
Iv-l- “3C
JREAKER
I
ON
0 0
-4
OFF
0
AC RECEPTACLE 1
/
VOLTMETER
No FUSE I~REAKER
AC RECEPTACLE 2
A ECEPTACLE 1
NO-FUSE ‘BREAKER
AC RECEPTACLE 2
FULL POWER SWITCH \
0
OAC V\
,
J) E
I
0
/
\ OJ
/
\
AC RECEPTACLE 1
VOLTMETER
NO-FUSE BREAKER
AC RECEPTACLE 2
MODEL RGX305
22ov, 23ov, 240v
RGX405
22ov, 23ov, 240v
MODEL
,RGX505
MODEL
RGX305 RGX405 RGX505
MODEL
RGX305D RGX405D RGX505D
22OV, 23OV, 240V
llOV, 12Ov llOV, 120v llOV, 120v
- 12 -

4-3 PANEL B

DC FUS
DC OUTPUT TERMINAL
J
DC
EARTH (GROUND) TERMINAL
FUSE IOA
EARTH (GROUND) TERMINAL
AC RECEPTACLE 3
MODEL RGX305 RGX405 RGX505
RGX305D RGX405D
RGX505D
EAR-iH (GROUND) TERMINAL AC R‘ECEPTACLE 3
- 13-
THROUGH BOLT SLIP RING
COVER BOLT
FRONT COVER
SHAFT
I
I
RUBBER MOUNT
/
ROTOR COMPL.
I
ENGINE P.1
-..-.. ‘.O.
I
I
I
REAR ‘COVER
STAi’OR COMPL. COOLI’NG FAN
H
8
q
z
;
;;1
E
=! -I p 5
z
SHAFT
BkUSH HOLDER
5-2 FUNCTIONS 5-2-l STATOR
-l-he stator consists of a laminated silicon steel sheet core, copper wire which winds the core, and lead wires which de­liver the power. The copper wire is wound into the main coil, sub (auxiliary) coil, and DC coil. AC output power is taken from the main coil, and DC output power from the DC coil. The outside diameters and laminated core thicknesses of various models are as shown below.
Fig. 5-1
Fig. 5-2
MODEL
RGX305
RGX405 1 RGX505
RGX305D RGX405D 1 RGX505D
+yg+++j
Table 5- 1
- 15-
5-2-2 ROTOR
The rotor consists of a laminated silicon steel sheet cover with a field coil wound arount it and cooling fans and slip rings at both ends of the shaft. The field coil leads are con­nected to the slip rings and direct current (DC) to the field coil turns the rotor and magnet. The tooling fans cool the generator by drawing cooling air from the slip rings and dis­charging it through the fans.
.
FAN
SLIP RING
BEARING
Fig. 5-3
Fig. 5-4
MODEL
I
RGX305
RGX405
RGX505
RGX305D
RGX405D
RGX505D
d (mm)
99.6
118
118
(inch)
3.92
j
4.65
4.65
I bnml
100
80 loo
(inch)
3.94
3.15
3.94
Table
5-2
- 16 -
5-2-3 BRUSHES
- - - --------­An exciting current is supplied from the AVR to the rotor. The brushes are made of carbon; and the brush-holders of plastic. It is necessary to keep the contact pressure between the brushes and slip rings withing specific limits. Thus, care must be taken of brush length. (See
9-3 BRUSHES.)
5-2-4 AVR (AUTOMATIC VOLTAGE REGULATOR)
The automatic voltage regulator employs an electronic cir­cuit to automatically regulate voltage.
5-2-5 VOLTMETER
The voltmeter comes in two types, a 150V maximum type and a 300V maximum type. Type voltmeter indicates generator output voltages. The generators with a generated voltage of 1 lOV, 120V type and dual voltage type use the
15OV maximum type voltmeter; and those of 22OV, 23OV,
and 240V type specifications use the 300V maximum type voltmeter.
RGX305. RGX305D
RGX405. RGX405D RGX505, RGX505D
Fig. 5-5
RGX305, RGX305D
Fig. 5-6
RGX405, RGX405D RGX505, RGX505D
300 V MAX.
150 V MAX.
(220 V. 230 V. 240 V)
(110 v, 120 VI
Fig. 5-7
-17-
5-2-6 NO-FUSE BREAKER
The no-fuse breaker prevents AC output overcurrent and shortcircuit overcurrent. Some models have one no-fuse breaker, and the others have two. The single no-fuse breaker protects the generator from
maximum current; and the double no-fuse breakers protect
the generator from maximum current, and its receptacles. If the generator is operated for long above the maximum current, the internal temperature of the generator abnormal-
ly rises to cause insulation deterioration, burning, electric
NO-FUSE BREAKER
shock, and electric leakage. The no-fuse breaker protects
FUSE HOLDER
the generator from such troubles. The receptacles and AC
F&. 5-8
plug have their own rated capacities. (Refer to
5-2-8 RECEPTACLES AND PLUG.)
If they are used above the rated
current, insulation deterioration, buring, electric shock, or leakage can occur.
These troubles are prevented by the no-fuse breaker. Table 5-3 shows breaker capacities and protecting objects.
1
Model
@eciiications
N.F.B. Protecting Object
N.F.B.
Protecting Object
11ov
30A Maximum current
RGX305
I
220V. 23OV. 240V
I 15A (2P2E)
Maximum current
RGX305D ( 110/22OV, 120/24OV ! 15A (2P2E) Maximum current
) 50Hz-1 lOV, 60Hz-120V (
30A
1 Maximum current
I
RGX405 !
60Hz-11ov :
35A ! Maximum current
I
I
22OV, 230V
! 20A(2P2E) j
Maximum current I
I
240v
) 15A (2P2E) ’
Maximum current
I
; 110/22OV, 6OHz-120/240V ’ 20A (2P2E) I Maximum current
RGX405D i
5OHz-120/24OV ’ 15A(2P2E) j Maximum current 1
I
50Hz-11OV. 6OHz-120V
40A
; Maximum current
30A
, 30A Receptacle
RGX505 :
22OV. 230V 25A(2P2E) i Maximum current
240V / 20A(2P2E) Maximum current
60Hz-11 ov 45A / Maximum current 30A 30A Receptacle
i
RGX505D 1
110/22OV, 6OHz-120/240 25A (2P2E) 1 Maximum current 20A (2P2EI
3OA Receptacle
5OHz-120/24OV 20A (2P2E) 1 Maximum current
Table 5-3
l
2P2E means the bipolar doubleelemenr type, and if either of tw pairs of currents running through tie no-fuse breaker exceeds the rated cur­rent, the no-fuse breaker operates to turn power off.
The 22OV. 23OV, and 240V types use tie two pairs connected in series,
and the 1oOV and 120V type have them connected in parallel.
- 18 -
5-2-7 FUSE
The fuse prevents DC output overcurrent and shortcircuit overcurrent. If the generator is operated at a level exceeding the maximum current, it can cause insulation deterioration. burning, electric shock. and electric leakage. The fuse protects the generator from these troubles.
Fuse capacity: 1 OA
5-2-8 RECEPTACLE
and AC PLUGS
These are used for taking AC output power from the generator. A total of five kinds of receptacles, each varying in rated voltage and current from another, are used. Each model has at least one receptacle to deliver the rated generator output.
As many AC plugs as the receptacles, each matching the corresponding receptacle, are provided. Table 5-4 shows the rated current for each receptacle. Be careful not to use the receptacles and AC plugs beyond the specified limits to prevent burn­ing.
I
tz&@ /
up to total i 5 amperes
from two receptacles
@!
w j
up to 15 amperes
I
;a; ]
‘aI
up to 20 amperes
I
up to 30 amperes (See Caution.)
Table 5-4
5-2-9 TERMINALS
The terminals are for producing DC output power, and come in two colors, red and black. The red one is positive (+), and the black one negative (-) .
5-2-10 FRONT COVER
The front cover is an aluminum die casting and is mounted on the main bearing cover of the engine. It has vents to dis­charge cooling air from the generator and the vents are de­signed to prevent fingers from entering.
Ceution: Taking out power from TWIST LOCK RECEPTACLE,
put rhe plug into ouflet end turn clockwise to lock it.
Fig. 5-9
RED
BLACK
Fig. 5- 10
RGX405, RGX405D
RGX305 RGX305D
RGX505, RGX505D
Fig 5-17
- 19 -
5-2-l 1 REAR COVER
The rear cover is also an aluminum die casting, and has a faucet joint to hold the stator together with the front cover. It has bosses inside for holding the brushes, and slits for taking cooling air in. The slits are so designed that human fingers will not go in.
RGX305
RGX305C
RGX405, RGX405D
RGX505, RGX505D
Fig. 5-12
5-2-12 RUBBER MOUNTS (RUBBER VIBRATION
ISOLATORS)
Rubber pads for controlling generator vibration and disloca­tion. These are made of the most suitable rubber material to optimum shape and hardness.
5-2-13 PIPE FRAME
Fig. 5-73
The pipe frame consits of a pipe frame skeleton, side plates A and B, box stay, and air guide.
SIDE PLATE B
PIPE FRAME
SIDE PLATE A
Loading...