Subaru PKX301T, PKX301, PKX201, PKX201ST, PKX401 User Manual

...
PKX series
201/301/401 201ST/301ST 210/310
201H 201T/301T
9ZZ9990119
北米
SUBARU Pump
1 2
7
5
1
4
3
PKX201,301,401, 201H,
201ST, 301ST,
210, 310
6
7
3
1
1
2
1
18
17
16
15
14
13
19
21 22
2
4
3
2
2
9
2
3
3
4
5
Single grade
Multi grade
Ambient temperature
2 3
5W
10W
20W
#20
#30
10W-30
10W-40
-20 -10 0 10 20 30
-4 14 32 50 68 86
4
#40
40 C
104 F
5
1
6
10
8
1112
23
5
PKX201T, 301T
6
20
24
7
8
23 24
1
20
10 9
1211
6
19 18
1
4
1
17
16
21
1415
25
13
2
22
26
5
1
2
PKX201T, 301T
7 28
5
6
2
3
4
6
PKX201,301,401, 201H,
1
201ST, 301ST,
7 28
210, 310
54 6
2
1
1
3
7
7
1
8
1
0.6 - 0.7 mm
2
2
1
3
3
54 6
1
4
4
1
3
NOTICE
FEDERAL EMISSION COMPONENT DEFECT WARRANTY and CALIFORNIA EMISSION CONTROL WARRANTY are applicable to only those engines/ generators complied with EPA (Environmental Protection Agency) and CARB (California Air Resources Board) emission regulations in the U.S.A.
NOTICE
To the engines/generators exported to and used in the countries other than the U.S.A., warranty service shall be performed by the distributor in each country in accordance with the standard SUBARU engine/generator warranty policy as applicable.
FOREWORD
Thank you very much for purchasing a SUBARU PUMP. This manual covers operation and maintenance of SUBARU PUMP. All information in this publication is based on the latest product information available at the
time of approval for printing. Please read this manual carefully before operating. Please take a moment to familiarize yourself with the proper operation and maintenance
procedures in order to maximize the safe and efficient use of this product. Keep this owner’s manual at hand, so that you can refer to it at any time. Due to constant efforts to improve our products, certain procedures and specifications are
subjected to change without notice. When ordering spare parts, always give us the MODEL, PRODUCTION NUMBER and SERIAL
NUMBER of your pump. Please fill in the following blanks after checking the production number on your pump. (Location of label is different depending on the pump specification.)
ENGLISH
PROD No.
SER No. (Stamping
SER No.
PROD No. / SER No. (
)
Label
)
CONTENTS
Page
1. SAFETY PRECAUTIONS................................................................................... 2
2. COMPONENTS.................................................................................................. 5
3. PRE-OPERATION FOR STARTING .................................................................. 6
4. OPERATING YOUR PUMP................................................................................ 7
5. MAINTENANCE ................................................................................................. 7
6. PREPARATIONS FOR STORAGE..................................................................... 10
7. OIL SENSOR INSTRUCTIONS
8. SPARK ARRESTER (OPTIONAL)...................................................................... 10
9. EASY TROUBLESHOOTING............................................................................. 11
10. SPECIFICATIONS.............................................................................................. 12
NOTE Please refer to the illustrations on the back page of the front
cover or back cover for Fig.
............................................................................
1 1
ii
1 to
i indicated in the sentence.
1 1
ii
10
FRANÇAISE
ESPAÑOL
1
1. SAFETY PRECAUTIONS
Please make sure you review each precaution carefully. Pay special attention to statement preceded by the following words.
“WARNING” indicates a strong possibility of severe personal injury or loss of life if instructions are not followed.
“CAUTION” indicates a possibility of personal injury or equipment damage if instructions are not followed.
ENGLISH
WARNING
CAUTION
WARNING
Never inhale exhaust gasses.
: EXHAUST PRECAUTIONS
They contain carbon monoxide, a colorless, odorless and extremely dangerous gas which can cause unconsciousness or death.
Never operate the pump indoors or in a poorly ventilated area, such as tunnel, cave, etc.
Exercise extreme care when operating the pump near people or animals.
Keep the exhaust pipe free of foreign objects.
FRANÇAISE
WARNING
Gasoline is extremely flammable and its vapors can explode if ignited.
Do not refuel indoors or in a poorly ventilated area.
Be sure to stop the pump prior to refueling.
Do not remove fuel tank cap nor fill fuel tank while engine is hot or running.
: REFUELING PRECAUTIONS
Allow engine to cool at least 2 minutes before refueling.
Do not overfill the fuel tank.
If fuel is spilt, wipe it away carefully and wait until the fuel has dried before starting the engine.
After refueling, make sure that the fuel cap is secured to prevent spillage.
ESPAÑOL
WARNING
Do not operate the pump while smoking or near an open flame.
Do not use around dry brush, twigs, cloth rags, or other flammable materials.
Keep cooling air intake (recoil starter area) and muffler side of the engine at least
: FIRE PREVENTION
1 meter (3 feet) away from buildings, obstructions and other burnable objects.
Keep the pump away from flammables and other hazardous materials (trash, rags, lubricants, explosives).
WARNING
Be careful of hot parts.
: OTHER SAFETY PRECAUTIONS
The muffler and other engine parts become very hot while the pump is running or just after it has stopped. Operate the pump in a safe area and keep children away from the running pump.
Do not use diaphram pump for the mixture of water and oil.
Do not touch the spark plug and ignition cable when starting and operating the engine.
1m
1m
2
Loading...
+ 11 hidden pages