Studer AJ-201, AJ-254, AJ-401, AJ-252, AJ-402 User's And Installer's Manual

...
AJ V3.5
AJ series
AJ seriesAJ series
AJ series
Betriebs-und Montageanleitung
Manuel d’utilisation et de montage
SINEWAVE INVERTER - SINUS-WECHSELRICHTER
ONDULEUR SINUSOÏDAL!
AJ 20
0
A
J 20
0
AJ 20
0
A
J 20
0
AJ 40
0
A
J 40
0
AJ 40
0
A
J 40
0
AJ 80
0
A
J 80
0
AJ 80
0
A
J 80
0
AJ 200
0
A
J 200
0
AJ 200
0
A
J 200
0
AJ
A
J AJ
A
J xxx-
S
x
xx-
S
xxx-
S
x
xx-
S
2
English description--------------------------------------------------------3 Introduction--------------------------------------------------------------------3 Note -----------------------------------------------------------------------------3 Installation ---------------------------------------------------------------------3 Use ------------------------------------------------------------------------------5 Models with standby system ----------------------------------------------5 Safety---------------------------------------------------------------------------7 Maintenance ------------------------------------------------------------------8 Warrantty limit ----------------------------------------------------------------8 Limits of manufacturer responsibility ------------------------------------8 JT8 Remote control for AJ 800 & 2000 -------------------------------8 Technical features-----------------------------------------------------------9 Model with built-in solar charger --------------------------------------- 10
Deutsche Beschreibung----------------------- 11 Einführung------------------------------------------------------------------- 11 Vorsicht----------------------------------------------------------------------- 11 Installation ------------------------------------------------------------------- 11 Anwendungen -------------------------------------------------------------- 13 STANDBY oder Lasterkennungsschaltung-------------------------- 14 Unterhalt --------------------------------------------------------------------- 15 Haftungsausschluss------------------------------------------------------- 16 JT8 Fernsteuerung für AJ 800 und 2000-----------------------------16 Technische Daten ---------------------------------------------------------16 Solarladeregler für fotovoltaïsche Solarmodule -------------------- 17
Instructions en français---------------------- 19 Introduction------------------------------------------------------------------19 Mise en garde---------------------------------------------------------------19 Installation ------------------------------------------------------------------- 19 Utilisation -------------------------------------------------------------------- 21 Modèles avec STANDBY ------------------------------------------------ 22 Sécurités--------------------------------------------------------------------- 22 Maintenance ---------------------------------------------------------------- 23 Exclusion de la garantie:------------------------------------------------- 24 Exclusion de la responsabilité ------------------------------------------ 24 Caractéristiques techniques--------------------------------------------- 25 Modèles avec chargeur solaire (versions S) ------------------------ 26
DECLARATION OF CONFORMITY
------------------------- 27
3
English description
Introduction
The sinewave inverters of the AJ series have been designed to meet industrial and domestic needs. They fulfil the highest requirements of comfort, safety and reliability. Any device designed for the public electrical network of 230 V 50 Hz can be connected to them (up to the nominal power of the inverter). The AJ series is the perfect source of tension in any place where the public network is not available. This document is an essential part of the inverter and must always be carried with it and be at the disposition of anyone working on the installation. Should you have any doubt or question, do not hesitate to contact your specialist salesperson who will give you the best advice.
Note
A deficient assembly could result in damage to the device, cause function failures or potential damage to the users. The working device generates a high tension which might be fatal in case of contact. So, any manipulation of the inverter must be carried out with utmost care.
THE OWNER MUST NOT MANIPULATE ANY PIECE INSIDE THE INVERTER.
Opening the inverter or using it incorrectly will result in the immediate loss of the warranty. No current or tension generating devices (public grid, generator, ...) may be connected to the outlet of the inverter because this could result in its destruction.
The inverter AJ is to be used only with a lead battery. As for the usage of batteries, follow the manufacturer’s instructions.
Installation
The AJ sinewave inverter is an electronic device, for which some caution must be taken when installing it: Place where the inverter is to be installed :
- Out of reach of unauthorised persons, specially children.
- In a dry place (max. 95% humidity), and in any case with no condensation.
- Not directly on top of the batteries.
- Ventilation must be free, and a space of 10
cm. on each side is needed for good evacuation of the internal heat.
Fitting the inverter
The inverter is fitted by screws (max. 4mm for AJ 200-AJ 800 or max. 8mm for AJ 2000) using the four holes provided. The fitting screws are not supplied with the inverter. It may be fit into any position.
L
89mm (J200 - 800)
L
160mm (J2000)
AJ 200 L= 163mm
AJ 800 L= 428mm
AJ 2000 L= 399mm
AJ 400 L= 370mm
4
Connection
The connection of the inverter should be done with utmost care. First connect the consumer devices so as to prevent any further contact once the 230 V tension is present. The technical data and connection’s description, is either under one side of the inverter or onto the cable connection side. Installation is to be made only with authorised persons.
Connecting the consumer devices
The AJ inverter is supplied with a 230 V cable for the consumer devices. This connection must be done observing the colours: Yellow-green: earth Brown: phase Blue: neutral Once the consumer devices are connected, make sure that they are turned off before connecting the battery
Note
An Inverter constitutes an independent power supply from net and could be considered in the same way as a generator set. The phase and the neutral are not differentiate. The tension in between the phase and the neutral is 230V. An appropriate divisor establishes a 115V tension in between neutral and earth, and the phase and earth. According to the local prescriptions or particular requirement, (example: use of a ground fault detector) a true neutral may be established by connecting the neutral and the earth wire together. The so connected point, may be
connected with an existing earth: earth of building; the chassis of vehicle or the hull of ship.
Equivalent schema
Connecting the battery Once the consumer devices are connected, make sure that the installations instructions of the 230V has been followed with utmost care before connecting the battery. The cable of the battery is supplied with the inverter and already connected in it. A fuse must be installed on the battery. Connect the battery observing carefully the polarity. The AJ inverter, except 2000W/12V, is protected against inversion by a fuse, but if the polarity should be inverted, the inverter must be sent to the manufacturer for control. Connect the battery using the following colours: BLACK cable: negative pole (-) RED cable: positive pole (+) For AJ 200, dominant colour is applicable
When connecting the battery, there’s a spark
48V
+
DC/AC
1uF
R1
R2
Fuse
Blue Green
/ Yellow
Brown
R1=R2= 2,7M ohm (not existing in AJ201 - AJ252 - AJ 254)
1uF/63V 2x10nF
Metalic housing
5
(Danger of explosion!), because of the charging of the internal condensator. Check that the cables are well adjusted. As long as it is possible, do not extend the cables supplied with the batteries. Extending them may increase the losses and cause malfunction of the inverter. Once the inverter is connected to the batteries, a 230 V tension is present in the outlet of the inverter.
Use
Control and indicators
Control switch on/off
There is a switch on the inverter to activate or deactivate it. Use this function to save the energy of the batteries when you are not using the inverter.
Green indicator
A green light on the inverter indicates its function mode: Off: the 230 V tension is NOT present in the
outlet, the inverter is off.
Illuminated: a 230 V tension is present in the
outlet, the inverter is on. Blinking: No load (standby)
the 230 V tension has
been cut due to an alarm; the inverter
will resume function when the failure
has disappeared (see the failure table).
Acoustic indicator
The AJ inverter has an acoustic indicator for the following instances:
Intermittent beep: there is a failure in the
inverter and the outlet tension will be interrupted.
Possible failures: Overheat: the acoustic indicator beeps 3 ºC
before cutting the tension. If the temperature reach its normal level, the tension in the outlet is not interrupted.
Low battery tension: the indicator beeps for a
minute before the interruption. If the tension of the battery rises, the outlet tension is not interrupted.
Continuous beep for two seconds: you have
pressed the ON/OFF switch to restart the inverter. The tension in the outlet will be immediately present after the acoustic signal.
Model wi th standby system
The AJ inverter with a power of 400 W and more are equipped with a standby system witch is in function when no load are connected. In that situation the inverter is in low power consumption mode. The output tension is not continuously present and the LED is blinking as long as no load is detected. The minimal load detected can be adjusted between 1 and 20 W. In most case this adjustment is not necessary. This adjustment is made with a small screw driver in the hole marked standby. This adjustment is made with a small screw driver in the hole marked standby. Adjusting the switching-on level is as follows: Switch off all consuming devices; turn the Turning Knob to the Left (counter-clockwise)until the LED is blinking, switch ON the smallest consuming device (i.e. Mobile phone charger); turn the Turning Knob slowly to the right until LED is lit continuously. Check that the inverter will go back in standby mode when you remove the load. If not, this mean that the load is too small to be detected. If the standby is not required, turn the Knob
fully to the right.
6
In the full counter clockwise position, the sensibility is minimal (20 W). Do not push on the screw driver.
NOTE : in this mode the output tension is intermittently present at the output
7
Safety
The inverter is electronically protected. But protection against polarity inversions of the battery occurs with an internal fuse, except for 2000W/12V inverter, which has no fuse. The following table will show you the different failures and their consequences.
FAILURE CONSEQUENCE SOLUTION Low battery tension Voltage < 1.8V/cel
Inverter momentarily stopped, the green indicator blinks.
Automatic restart when the battery tension rises
Deep discharged battery (voltage <1,5V/cel)
Inverter stopped Inverter should be manually restarted
when the battery as reach 2V/cel
Overheat Inverter momentarily
stopped, the green indicator blinks.
Automatic restart when the temperature reaches the normal range.
Battery over voltage Inverter stopped. Wait until the battery tension reaches the
correct level. Push the ON/OFF switch to reactivate the inverter.
Short circuit in the outlet Inverter stopped. Eliminate the short circuit.
Push the ON/OFF switch to reactivate the inverter.
Overload Inverter stopped. Use the inverter only in the range of its
nominal power. Regular use in overload power diminished the lifetime of the inverter. Push the ON/OFF switch to reactivate the
inverter. Inversion of the battery polarity
Internal fuse broken down
Back to manufacturer for testing
8
Maintenance
The inverters of the AJ series do not need any special maintenance. The casing may be cleaned with a damp cloth (not wet). In the case of malfunction, the inverter should be sent back to the manufacturer for control in its original packing. Before sending the inverter, check the table above. The battery is loaded and is in accordance to the inlet nominal tension of the device. The consumer devices do not have any defects or overload for the inverter. Should you contact your salesperson, note the following points before calling: (you will find this information on the label underneath the inverter)
- Series number
- Power of the inverter
- Inlet nominal tension of the inverter So you will have quick and efficient help to solve your problem.
Warranty limit
The warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damage arising from improper use like:
- Reverse of battery polarity
- Inadequate input voltage (over voltage)
- Back-feed of the inverter output by public network , generator or any other source.
- Mechanical shock or deformation especially by
transport due to an inadequate package.
- Contact with liquid or oxidation by conden­ sation
- Use in inappropriate environment (dust, corro­ sive vapour, humidity, high temperature,...)
This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone other than Studer INNOTEC or a company authorised by Studer INNOTEC. In order to qualify for the warranty, the product must not be disassembled or modified
.
Limits of manufacturer
responsibility
STUDER INNOTEC cannot control the installation, use and maintenance of the inverter. Thus, we are not responsible for damages, costs or losses resulting from an installation which is not in accordance with the regulations or inappropriate use or maintenance. The customer is always responsible for the use of the inverters STUDER INNOTEC. This device has not been designed and is not warranted for use in life support apparatus or any other critical device with potential risks of important harm to people or to the environment. We do not accept any responsibility for any violation of patent rights or other third person rights resulting from the use of the inverter. STUDER INNOTEC keeps the right to modify their products without previous notice.
JT8
JT8JT8
JT8
Remote control for
AJ 800 & 2000
AJ 800 & 2000AJ 800 & 2000
AJ 800 & 2000
0000!!!!
- Functions on remote control are the same as control and indicator on the inverter. (See above)
Remote control should be connected with the inverter with the original 10m. STUDER cable or any RJ11/6p 1:1 cable up to max 50m.
9
Technical data
AJ 200
AJ 400
MODEL
AJ - 201 AJ - 252 AJ - 254 AJ - 401 AJ - 402 AJ - 404
Battery voltage (V) 12 24 48 12 24 48 Input voltage (V) 10.5 - 16 21 - 32 42 - 64 10.5 - 16 21 - 32 42 - 64 Nominal / peak power (W) 200/400 250/550 250/ 500 400/1000 400/1400 400/ 850 Standby / Idle power (W) 0.3* / 1.9 0.3* / 3.3 - / 5 0.3 / 3.8 0.4 / 8.5 1/ 10 Maximum efficiency (%) 93 94 94 93 94 94 Dim. 142 x 84 x L( mm) L= 169mm 228mm Weight in kg. (approx.) 2.3 2.4 2.6 8.5 Remote control ability Option Option Standby system (1 to 20 W) * with option S -
v
Solar charger (model S) * 10A - 15A -
AJ 800
AJ 2000
MODEL
AJ - 801 AJ - 802
AJ - 2001 AJ - 200
2
Battery voltage (V) 12 24 12 24 Input voltage (V) 10.5 - 16 21 - 32 10.5 - 16 21 - 32 Nominal power (W) 800/2400 800/3000
2000/5000 2000/5000
Standby / Idle power (W) 0.3 / 9 0.4 / 10 0.5 / 13 0.4 /18 Maximum efficiency (%) 93 94 92 94 Dim. 142 x 84 x L( mm) L= 440mm 273 x 415 x 117mm Weight in kg. (approx.) 8.5 19 18 Remote control Optional
v v
Standby system (1 to 20 W)
v v
Solar charger (model S) 25A 30A
Output voltage Sine wave 230V +/-5% (120V +/-5%)
Frequency 50 Hz +/- 0.05 % (60 Hz +/-0.05%) Ventilation From 45° C
Overheating protection
v
Overload protection
v
Short circuit protection
v
IP protection index IP 30 (AJ 2000 = IP 20)
Cos ϕ
0.1-1