Please leave this instruction booklet with the home owner
as it contains important guarantee, maintenance and safety
information
WC1
WC2
WC3
WC3 shown
CE compliant product
IMPORTANT
In the unlikely event of experiencing a problem with
this product, please contact our helpline on
0844 98 000 97
Due to the nature of this product DO NOT attempt to
return or remove this product from its installation.
Please read installation details carefully as they are intended to ensure this product
provides long, trouble free service. Failure to install the unit in accordance with the
installation instructions will lead to invalidation of the warranty.
The WC1, WC2 and WC3 are slimline sanitary macerators for domestic use, designed
for the drainage of fixed WC and requiring just 140 mm clearance between the WC spigot
and bathroom wall.
WC1
Designed to pump waste away from one WC.
WC2
Designed to pump waste away from one WC and one
sanitary device.
WC3
Designed to pump waste away from one WC
and two sanitary devices.
Please note the following warning signs.
Warning of possible electrical hazard.
Possible danger to personnel or important installation requirement.
APPLICATION
All the safety & operating instructions in this booklet must be followed. The unit must not be used for any other application without the written
consent of Stuart Turner Limited.
The unit must be installed by a qualified person.The unit is not suitable for heavy commercial/industrial applications.The plumbing installation must comply with the Building Regulations.This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made
by children without supervision.
Children should be supervised to ensure that they do not play with the
appliance.
All pipework referred to in this installation manual are typical PVC
waste pipe size's used in the UK.
STORAGE
If this product is not to be installed immediately on receipt, ensure that it is stored in a
dry, frost and vibration free location in its original packaging.
- 3 -
ACCESSORIES CHECKLIST
IMPORTANT: With the product
removed from its packaging check
for any damage prior to installation.
If any damage is found contact Stuart
Turner Ltd within 24 hours of receipt.
A
Qty 1
WC Connector
EF
Qty 1 (WC2)
Qty 2 (WC3)
Inlet Connector
B
Non-Return Valve
Assy
Qty 1
C
Qty 1
22, 28, 32 mm
Adaptor
Qty 1 (WC2)
Qty 2 (WC3)
D
Qty 3
Adjustable
Clips
Reducing ring to
suit 32 mm (1¼ ")
diameter pipe
1 LOCATION
1.11 The unit must be connected directly to the outlet spigot of the WC pan. Allow a
minimum height of 220 mm above the unit, for maintenance and servicing.
1.12 The unit must be positioned away from heat sources, such as radiators and
heaters.
1.13 Care must be taken to protect the unit against frost and freezing. All pipes at risk
of freezing must be protected by thermal insulation.
1.14 The unit must be located immediately behind the WC pan and must not be mounted behind a partition wall.
Cont ...
- 4 -
2 CONNECTIONS
Outlet - 22, 28 or 32 mm outside
diameter piping using flexible adaptor
180mm
See Note 2
OR
See Note 1
2.11 Note 1: Only connect one sanitary device per inlet connection.
2.12 Note 2: The shower tray (lowest waste outlet) must be a minimum of 180 mm above the base of the macerator, to ensure necessary drainage and must not contain a trap.
- 5 -
Cont ...
3 INSTALLATION
INSTALLATION GUIDELINES
1.4 m
3.11 Always use smooth bends or
2 x 45
o
bends. Do not use 90
o
elbows.
3.12 You must install vertical pipework
first. Diagonal runs are not permitted. Connection to the soil
o
discharge pipe must be with a 45
inclined connection.
3.13 If the discharge is lower than the
unit, to prevent water siphoning from
the outlet pipe, an air admittance
valve must be used (not supplied)
capable of withstanding 6 psi, and
fitted to a vertical vent pipe at least
1.4 m higher than the unit..
3.14 Unit must be placed directly behind
the WC.
3.15 Do not connect to washing machines or dishwashers.
7
6
5
4
3
2
HEAD (metres)
1
0
0 102030405060708090100
FLOW (l/min)
3.17 Always ensure full access to the unit is possible for maintenance.
3.16 Ensure that the total flow drained at any
given time never exceeds the total pumped flow from the unit, taking into account the height and length of the
outlet pipe. For instance,
- At 5 metres outlet head, the outlet flow is 23 l/min.
- At 2 metres outlet head, the outlet flow is 85 l/min.
Cont ...
- 6 -