Please leave this instruction booklet with the owner as
it contains important guarantee, maintenance and safety
information
FOR POSITIVE HEAD APPLICATIONS ONLY
PATENT
APPROVED
GB 2494485 A
CE compliant product
PRODUCT DESCRIPTION
Electric motor driven peripheral pump with bypass, complete with an automatic control
system consisting of flow switch and electronic control.
APPLICATION
The Flomate is a mains booster pump with an automatic control system for domestic
use, designed to assist the pressure from the mains supply, where the mains pressure is
insufficient. This unit requires a minimum unassisted supply flow of 0.6 l/min to operate.
The pump is limited to producing a maximum flow of not greater than 12 l/min, and a
maximum pressure of 3.0 bar.
When the flow/pressure from the rising main exceeds the pump output, the patented
applied for integral bypass will direct the water into the system as normal.
The Flomate mains booster is a patent applied for design.
Please note the following warning signs.
Warning of possible electrical hazard.
Possible danger to personnel or important installation requirement.All the safety and operating instructions in this booklet must be
followed.
The pump must not be used for any other application without the
written consent of Stuart Turner Limited.
The pump must be installed by a qualified person.The pump is not suitable for heavy commercial/industrial applications.The installation must comply with the latest Building Regulations,
Wiring Regulations (BS 7671) and Water Supply Regulations (see
notes).
This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made
by children without supervision.
Children should be supervised to ensure that they do not play with the
appliance.
Notes
This product must be installed in accordance with the current Water
Supply (Water Fittings) Regulations.
Under no account should the internal flow restrictor be removed, or
replaced with an alternative design.
Cont ...
- 2 -
The flow restrictor must be replaced every 2 years.
Care must be taken to ensure the maximum pressure generated by the
pump combined with the incoming mains water pressure does not exceed the pumps maximum operating pressure of 6 bar.
Please read installation details carefully as they are intended to ensure this product
provides long, trouble free service. Failure to install the unit in accordance with the
installation instructions will lead to invalidation of the warranty.
STORAGE
If this product is not to be installed immediately on receipt, ensure that it is stored in a dry,
frost and vibration free location in its original packaging.
IMPORTANT: With the pump
removed from its packaging check
for any damage prior to installation.
If any damage is found contact Stuart
Turner Ltd within 24 hours of receipt.
(Not supplied)
B
A
Fig. 1
Item
A
DescriptionQty
Pump1
Item
B
DescriptionQty
G ¾ compression fitting with
isolating valve and seal (not
supplied) (or alternative)
Your product may vary slightly from the picture above.
2
- 4 -
Cont ...
1 READ BEFORE COMMENCING PUMP INSTALLATION
A. Water temperature
The water entering the pump must be controlled as follows:
o
C.
o
C.
o
bends.
1.11 The maximum allowable water temperature is 35
1.12 The minimum allowable water temperature is 4
B. Pipework - General
1.13 Secure pipework: Ensure pipework to and from pump is independently supported & clipped to prevent forces being transferred to inlet and outlet branches of pump.
1.14 Flux: Solder joints must be completed and flux residues removed prior to pump
installation (flux damage will void any warranty).
1.15 Pipework design: Care should be taken in the design of pipework runs to minimize the risk of air locks e.g. use drawn bends rather than 90
1.16 DO NOT introduce solder flux to flexible hoses, pumps or pump parts.
1.17 DO NOT allow contact with oil or cellulose based paints, paint thinners or strippers, acid based descalents or aggressive cleaning agents.
1.18 Water flow: An un-assisted flow rate of at least 0.6 l/min is required through the outlets to be pumped in order to make this pump work.
C. Plumbing & Electrical Installation Regulations
1.19 The plumbing installation must comply with “The Water Supply (Water Fittings)
Regulations 1999” and “BS 6700” building regulations.
1.20 The electrical installation must be carried out in accordance with the current national electrical regulations.
1.21 The electrical installation must be installed by a qualified person.
- 5 -
Cont ...
2 LOCATION - GENERAL
2.11 Access: For emergencies and maintenance the pump must be
easily accessible.
2.12 Protection: The pump must be located in a dry position, frost free and
protected from freezing, particularly when installed in a loft (not recommended). Ensure the pump is in a dry position, away from heat
sources, such as radiators and heaters.
2.13 Ventilation: Ensure an adequate air flow to cool the pump. Separate
the pump from other appliances that generate heat. An 80 mm (3 “) air
gap must be maintained around the pump.
2.14 Safety: The motor casing can become very hot under normal operating conditions. Care must be taken to ensure it cannot be touched during operation.
2.15 Water retention: Site the pump in a location where in the unlikely event of a water leak, any spillage is contained or routed to avoid electrics or areas sensitive to water damage.
2.16 Location point: The pump must be located after the mains water stop cock, in-
line to the connection to the boiler. Do not site the pump in the roof space, since
air locks can easily result.
2.17 Pump position: The pump must be positioned on its anti-vibration mounting feet
and as close to the water source as possible.
2.18 Direction of flow: Ensure the liquid flow is in the direction of the arrow, as marked on the flow switch reed clamp.
- 6 -
Cont ...
2.19 Pipework Connections:
Isolating valves: Always install isolating valves (not supplied) to
both suction and delivery pipe to aid future maintenance.
Pipework: Ensure pipework to and from the pump is independently
supported to prevent forces being transferred to the inlet and outlet
branches of the pump.
Bypass (see note ‘b’ below)
Inlet (see note ‘a’ above)
Mains water
stop cock
(Not supplied)
Typical installation
Mains
water
supply
Fig. 2
a) This pump must be installed in accordance with the Water Supply (Water
Fittings) Regulations.
Incoming mains pressure can vary, but must never exceed 6 bar. If there is
a possibility of exceeding 6 bar, separate inlet pressure control must be fitted.
b) It is advisable to fit a bypass pipe and isolating valves. This will allow removal
of the pump for maintenance and servicing, and ensure the water supply into
the property is still available during that period (Fig. 3).
Fig. 3
- 7 -
3 ELECTRICAL INSTALLATION / EARTHING
3.11 Regulations: The electrical installation must be carried out in accordance with the current national electrical regulations and installed
by a qualified person.
3.12 Safety: In the interests of electrical safety a 30 mA residual current
device (R.C.D. not supplied) must be installed in the supply circuit. This may be part of a consumer unit or a separate unit.
3.13 Before starting work on the electrical installation ensure the power supply is isolated.
3.14 The motor and wiring must not be exposed to water.
3.15 The supply cable must be positioned so that it is not stepped on, cut or damaged.
3.16 Electrical Connection:a) The pump is provided with a factory fitted supply cord.
b) This must be permanently connected to the fixed wiring of the mains supply.
c) Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring regulations.
d) A suitable method of connection would be via a double pole switched, fused
connection unit complying with BS 1363-4, protected with a fuse (see technical specification section).
e) The connection unit should be mounted in an easily accessible position and
should be labelled if confusion is possible, to allow easy identification of the
flomate isolating switch.
3.17 Earthing: This appliance must be earthed via the supply cord, which must be correctly connected to the earth point located in the terminal box.
3.18 Additional earthing: Certain installations may require additional earthing arrangements such as equipotential bonding. Reference should be made to the
relevant regulations concerning this subject to ensure compliance.
3.19 Connections: The pump must be permanently connected to the fixed wiring of
the mains supply using the factory fitted supply cord, via a double pole switched
fused spur off the ring main and NOT connected to the boiler or the immersion
heater circuits.
3.20 Wiring Of Connection Unit:
WARNING: This appliance must be earthed.
The wires in the mains lead (supply cord) are coloured in accordance with the
following code:
Green and Yellow:- Earth. Blue:- Neutral. Brown:- Live
As the colours of the wires in the mains lead of this appliance may not correspond
with the coloured markings identifying the terminals in your connection unit proceed as follows:
a) Green and yellow wire must be connected to the terminal in the connection
unit which is marked with the letter ‘E’ or by the earth symbol
green or green and yellow.
- 8 -
or coloured
Cont ...
b) Blue wire must be connected to the terminal which is marked with the letter ‘N’
or coloured black.
c) Brown wire must be connected to the terminal which is marked with the letter
‘L’ or coloured red.
3.21 Wiring Diagram:
The supply cord and internal wiring within the terminal box are
routed and secured to ensure compliance with the electrical
standard EN 60335-1. Do not disturb the internal wiring or factory
routing and securing of all internal wiring.
MAIN WINDING
BLUE
THERMOTRIP
CAPACITOR
3.22 Fuse:
S2
S1S1
START WINDING
L
N
BLACKRED
BLUE
BROWN
GREEN/YELLOW
FLOWSWITCH
REED (S3)
N
BROWN
MA
S2S3S3
ModelFuse Size (AMPS)
All Models5
N
230 VAC/1PH/50Hz
L
SUPPLY
E
Fig. 4
- 9 -
4 COMMISSIONING
4.11 Priming: This pump is self venting. Open the mains stopcock and allow the pump to fill and vent, please note the pump chamber must be full of liquid at all
times. Seal damage will result if the pump runs dry.
4.12 Starting:a) Ensure all outlets are closed, turn power supply ‘on’.
b) Open and close all outlets in turn associated with the pump allowing liquid to
flow from each outlet until all air is purged. As each outlet is opened and closed the pump will start and stop respectively.
c) Any tap or control valve within the system when opened and closed will now
turn the pump on/off. Check system for leaks, if clear the system is now
operating correctly
d) Carefully check pump and pipework for leaks whilst pump running and stationary before leaving the installation unattended.
4.13 For Further Technical Support: Phone the Stuart Turner PumpAssist team on 0844 98 000 97. Our staff are trained to help and advise you over the phone.
Note: When pumps are installed in another manufacturers original equipment, please contact the manufacturer for advice.
5 MAINTENANCE
5.11 Disconnect electrical supply before working on pump.
5.12 Turn off liquid supplies to the pump and release pressure by opening outlets before attempting maintenance.
5.13 The flow restrictor inside the pump must be replaced every 2 years (contact
Stuart Turner Ltd).
5.14 If the installation is fitted with an inline suction strainer, the strainer must be cleaned as necessary to ensure the pump has unrestricted flow.
5.15 No other routine maintenance is required.
5.16 After maintenance is completed, refer to Section 4 - Commissioning for instructions on restarting pump.
- 10 -
Cont ...
6 TECHNICAL SPECIFICATION
Volts/Ph/Frequency230/1/50
Power consumed500 Watts
Full load current2.2 Amps
RatingContinuous
Electrical
Max. No Starts per hour60
EnclosureIPX4
Fuse Size5 Amps
Max flow12 litres/min
Max head (closed valve)32 metres
Max working pressure *600 kPa (6 bar)
Max liquid temperature35
Min liquid temperature4
Mechanical
Max ambient air temperature40
Max noise level65 dB
Length210 mm
Width130 mm
Height 231 mm
Pump
Dimensions
Weight5.2 Kg
Inlet / outletG ¾ Male
Connecting cable1.5 metres
Connections
BodyBrass
ShaftStainless Steel
o
C
o
C
o
C
Mechanical SealNitrile/carbon/ceramic
Materials
Pump PartsBrass
*Max working pressure is the maximum pressure that can be applied to the pump
internal casing under any installation condition.
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.
- 11 -
Cont ...
7 TROUBLE SHOOTING GUIDE
SymptomsProbable CauseRecommended Action
Pump will not start.No water.Check required flow of liquid is available to the fittings of
approx. 0.6 l/min.
Water supply.Check water supply from mains and all stopcocks are open.
Electrical supply.Check wiring connections.
If flow exists inline with requirements - check that all electric
switches are on.
Is the correct fuse fitted?
Check circuit breaker is set.
Faulty reed switch/PCBRefer to circuit test as detailed in Fig. 5.
Pump starts when outlets are off.
or
Pump cycles (hunts) on/off
frequently.
Pump runs on when all terminal
outlets are closed.
Internal motor thermotrip
activated.
Leak in systemCheck tap washers, w/c valve washers, pipe joints.
Leak in system.Check tap washers, w/c valve washers, pipe joints.
Reed clamp out of position.Ensure reed clamp is fitted correctly in location groove
Jammed flow switch.Remove flow switch reed clamp whilst pump is running. If
Faulty reed switch or P.C.B.Remove flow switch reed clamp whilst pump is running.
Wait for thermotrip to auto reset and check that duty point and
run time is within specification (see Technical Section).
(Fig. 5).
pump stops proceed to isolate the pump electrically and
hydraulically and remove brass housing that contains float.
Check for free movement.
If pump continues to run, this indicates a closed circuit in
either the flow switch reed or P.C.B. in the terminal box, these
should be checked electrically.
- 12 -
Cont ...
7.11 Flow Switch Circuit Test:
1. First confirm visually that the flow switch reed clamp has not been dislodged
during handling or installation. The clamp must be fully located within its flow
switch body groove as shown.
2. To carry out the following test you will need to obtain a magnet, a typical fridge
magnet is suitable.
3. Ensure the power supply is switched on.
4. Position the magnet directly in front of the reed clamp as shown. If pump does not start, then slowly move the magnet up and down to a position that exceeds the extent of the reed clamp. The pump should instantaneously
start at some point during this extent of movement. If this does not happen,
this indicates a possible fault with the reed switch or the P.C.B which is located within the terminal box. These should be checked electrically. Consult Stuart Turner for further instructions.
Body
Reed Clamp
Magnet
Groove
Fig. 5
7.12 Environment Protection: Your appliance contains valuable materials which can
be recovered or recycled.
At the end of the products’ useful life, please leave it at an appropriate local civic
waste collection point.
- 13 -
Cont ...
8 THE FLOMATE GUARANTEE
Congratulations on purchasing a Stuart Turner pump.
We are confident this pump will provide many years of trouble free service as all our
products are manufactured to the very highest standard.
The Flomate Pump is guaranteed to be free from defects in materials or workmanship
for 2 years from the date of purchase.
EXTEND YOUR PUMP GUARANTEE
Register your pump details on-line now (within 30 days of date of purchase) and the standard 2 year guarantee will be extended FREE of charge for a further 1 year.
www.stuart-turner.co.uk
If you do not have on-line access or would like us to help you register your pump then
simply call our ‘PumpAssist’ helpline on 0844 98 000 97.
Please note that to validate your extended warranty we will require the following
information:
1. Full pump serial number (including last 3 digits) which can be found on the pump
rating label and the back page of the installation instructions.
2. Your name/address/telephone/e-mail.
3. The date of installation.
Within the guarantee period we will repair, free of charge, any defects in the pump
resulting from faults in material or workmanship, repairing or exchanging the whole unit
as we may reasonably decide.
Not covered by this guarantee: Damage arising from incorrect installation, improper use, unauthorised repair, normal wear and tear and defects which have a negligible effect on the value or operation of the pump.
Reasonable evidence must be supplied that the product has been purchased within the guarantee term prior to the date of claim (such as proof of purchase or the pump
serial number).
This guarantee is in addition to your statutory rights as a consumer. If you are in any
doubt as to these rights, please contact your local Trading Standards Department.
Cont ...
- 14 -
In the event of a claim isolate the unit and then please telephone ‘PumpAssist’.
0844 98 000 97
Proof of purchase should accompany the returned unit to avoid delay in investigation
and dealing with your claim.
You should obtain appropriate insurance cover for any loss or damage which is not covered by Stuart Turner Ltd in this provision.
Please record here for your records.
TYPE NO.SERIAL NO.DATE PURCHASED
Installers – Register with Stuart Turner and move up to Approved
Installer status
We receive thousands of enquiries every month from people seeking a Stuart
Turner installer and by registering your details with us, we can offer consumers the
opportunity to quickly locate an installer in their area.
Registration is free - simply click on the ‘register as an installer’ link on
our homepage at www.stuart-turner.co.uk and complete a short form
which will enable visitors to find your contact details on our web site
‘installer finder’. Alternatively use your smartphone to scan this QR code
and go straight to the form.
We’ll do the rest!
In addition we will ensure you receive advance notice on all new product launches and
access to any special offers or promotions.
Following initial registration, Stuart Turner offers a professional training programme,
enabling you to achieve Approved Installer status and opening the door to a range of
additional benefits.
Contact approvedinstaller@stuart-turner.co.uk for further details.
- 15 -
DECLARATION OF CONFORMITY
2006/42/EC
BS EN ISO 12100-1, BS EN ISO 12100-2, BS EN 809
2006/95/EC
BS EN 60335-1, BS EN 60335-2-41
2004/108/EC
BS EN 55014-1, BS EN 55014-2, BS EN 55022, BS EN 61000-3-2, BS EN 61000-3-3,
BS EN 61000-4-2, BS EN 61000-4-3, BS EN 61000-4-4, BS EN 61000-4-5, BS EN 61000-4-6,
BS EN 61000-4-11
1999/519/EC
BS EN 62233
2011/65/EU
IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTOR DRIVEN PUMP AS SERIAL NUMBER BELOW, COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E.E.C. DIRECTIVES.
RESPONSIBLE PERSON
AND MANUFACTURER STUART TURNER LIMITED
HENLEY-ON-THAMES, OXFORDSHIRE
RG9 2AD ENGLAND.