Stuart SCT1 Instructions For Use Manual

temperature controller
SCT 1
C
Temperature Controller
SCT1
Version 2.0
English
temperature controller
SCT 1
C
heat-stir
US152
HOT
1
2
3
4
5
6
7
8
9
STIR
undergrad
off
Power on/off
100
150
250
200
300°C
50
HEAT
HEAT
STIR
HOT
100
50
Power on/off
heat-stir
US152
150
200
250
4
3
2
1
off
5
6
7
US152
HOT
1
2
3
4
5
6
7
8
9
STIR
undergrad
off
Power on/off
100
150
250
200
300°C
50
HEAT
Power on/off
100
150
250
200
300°C
50
HEAT
Figure 1 - front view
Probe holder
Figure 2 - rear view
Retort clamp
Probe socket
Probe plug
Temperature
collar
probe
Controller plug
Locking
Figure 3 - Hotplate front view Figure 4 - Hotplate rear view
Contact thermometer indicator
‘Hot’ warning light
Stir on light
DIN socket
Mains on/off
Heat control
Stir control
switch (not on stirrer only unit)
2
Retort rod fitting
IEC power socket for hot condition plug
Temperature Controller
❖ Never move or carry the unit when in use or
connected to the hotplate.
❖ Do not use in a hazardous atmospheres or
with hazardous materials
SCT1 Instructions for use
Introduction
Thank you for purchasing this piece of Stuart equipment. To get the best performance from the equipment and for your own safety, please read these instructions carefully before use. Before discarding the packaging check that all parts are present and correct.
General Description
The Stuart SCT1 temperature controller is the ideal instrument for the accurate temperature control of aqueous and oil based samples in the laboratory. The SCT1 can be used in two different modes; as a precise temperature controller from 20 to 200°C or as a digital thermometer from -4 to 325°C. With digital setting and display of temperature, the SCT1 temperature controller is accurate to ±0.5°C.
The SCT1 is compatible with the following Stuart hotplates and hotplate stirrers: US150, US152, US152D, UC150, UC152, UC152D, SC162, and CC162.
Safety Advice before use
If the equipment is not used in the manner described in this manual and
with accessories other than those recommended by Stuart the protection provided might be impaired.
This equipment is designed to operate under the following conditions: -
❖ For indoor use only ❖ Use in a well ventilated area ❖ Ambient temperature range +5°C to +40°C ❖ Altitude to 2000m ❖ Relative humidity not exceeding 80% ❖ Use with a minimum distance all around of
200mm from walls or other items.
Preparation for use
To use the SCT1 temperature controller with either a metal top or ceramic top hotplate, place the hotplate on a firm, level surface.
Open the jaws of the retort clamp on the rear of the SCT1 temperature controller by turning the clamp knob anticlockwise. The clamp can be used with retort rods from 9.5mm to 13mm diameter. Slide the SCT1 on to the retort rod and tighten by turning the clamp knob clockwise.
NB: DO NOT OVER TIGHTEN
Connect the SCT1 controller plug to the DIN probe socket at the rear of the hotplate (Figures 1 and 4).
Connect the probe plug to the probe socket at the rear of the controller (Figures 2 and 4). To ensure the best connection, tighten the locking collar on the plug by turning clockwise.
Connect the mains supply lead to the IEC socket at the rear of the hotplate and switch on at the mains. Where the unit has a mains on/off switch, switch the unit on using this switch.
To switch on the SCT1 temperature controller, turn the heat control knob on the hotplate clockwise (Figure 3).
NB: The controller power is supplied by the hotplate
The SCT1 temperature controller and hotplate are now ready for use. Correct communication between the SCT1 temperature controller and the hotplate is indicated by the illuminated amber contact thermometer indicator on the front panel of the hotplate.
NB.: The hotplate and controller will perform an automatic self-test at switch on, before the current temperature of the probe is displayed. The factory default set temperature is 20°C.
3
Operation
temperature controller
SCT 1
C
Controller positioning
The SCT1 temperature controller is supplied with a detachable temperature probe (Figure2). This useful feature enables the SCT1 temperature controller to be positioned away from damaging fumes.
The temperature controller is factory set such that the retort clamp is positioned for mounting on a vertical retort rod. To mount the SCT1 temperature controller on to a horizontal retort rod, ease back the clamp situated at the rear of the controller sufficiently to clear the right-angled raised location. Rotate clockwise by 90° until the clamp snaps back into the location.
Probe positioning
For optimum temperature control, ensure the end of the sensing probe is immersed at least 20mm deep into the medium being controlled. The temperature probe when not in use should be placed in the probe holder located on the left hand side of the SCT1 control panel. For safety and to avoid contamination, always wipe the probe clean prior to placing into holder.
Using the SCT1 temperature controller
The SCT1 can be used in two different modes, either as a temperature controller (‘control mode’) or as a digital thermometer (‘monitor mode’).
To use the SCT1 in control mode
Ensure that the SCT1 temperature controller is connected to the hotplate. Also ensure the temperature probe is attached to the controller and immersed in the medium to be controlled before switching on at the mains.
US150, US152, US152D, UC150, UC152 and UC152D
Turn the unit on using the On/Off switch at the side of the unit. The SCT1 will power up in monitor mode. To turn on the temperature controller in control mode, turn the heat control clockwise on the front panel of the hotplate. On the digital models the LED display will show “---“.
The SCT1 temperature controller in control mode is indicated by the illuminated amber contact thermometer indicator on the front panel of the
hotplate (Figure 3). The LED and display will be visible on the SCT1 temperature controller panel (Figure 5) and the current temperature of the medium will be displayed.
Thermometer LED
Increase temperature set point
Decrease temperature set point
Figure 5 - SCT1 temperature controller panel
CC162 and SC162
A green LED will be visible on the front panel of the hotplate. To turn on the temperature controller, turn the heat control clockwise on the front panel of the hotplate. The SCT1 temperature controller in control mode is indicated by the illuminated amber contact thermometer indicator on the front panel of the hotplate (Figure 3).The LED and display will be visible on the SCT1 temperature controller panel (Figure 5) and the current temperature of the medium will be displayed.
NB: Turning the heat control clockwise on the hotplate turns the SCT1 temperature controller into control mode and cannot be used to set the hotplate temperature.
To set the temperature in controller mode
Press the + or - key once to instigate the temperature set point mode. This is indicated by a flashing LED on the SCT1 temperature controller display. To select the temperature, use the ‘+’ or ‘ –‘ keys to obtain the desired temperature. To set the temperature, release the key. The LED will cease flashing once the temperature has been set. With the probe in the sample, the thermometer LED will illuminate as follows:
❖Green – temperature set point not reached
4
❖Amber – liquid at set point ❖Red – liquid hotter than set point
NB: To obtain accurate temperature control, the minimum temperature set point must be at least 15°C above the surrounding ambient temperature.
To use the SCT1 in monitor mode
US150, US152, US152D, UC150, UC152 and UC152D
To use the SCT1 controller in monitor mode together with the hotplate, ensure the unit is switched off using the mains control switch at the side. Hold down both the ‘+’ and ‘ –‘ keys simultaneously on the SCT1 temperature controller and turn the mains switch to ‘ON’. Once the digital display illuminates, release the keys on the SCT1 temperature controller. Monitor mode will be indicated by a red flashing LED at the bottom right hand corner of the display of the SCT1 temperature controller. The amber control LED on the front panel of the hotplate will NOT be illuminated in monitor mode.
CC162 and SC162
To use the SCT1 controller in monitor mode, ensure the hotplate is switched off by turning the heat control on the hotplate anticlockwise to the ‘OFF’ position. Hold down both the ‘+’ and ‘ –‘ keys simultaneously on the SCT1 temperature controller, and turn the heat control ‘ON’. Once the digital display illuminates, release the keys on the SCT1 temperature controller. Monitor mode will be indicated by a red flashing LED at the bottom right hand corner of the display of the SCT1 temperature controller. The amber control LED on the front panel of the hotplate will NOT be illuminated in monitor mode.
NB: When in monitor mode, the SCT1 temperature controller operates as a digital thermometer only, and no longer controls the temperature of the medium in use. The hotplate temperature can now be manually adjusted to the desired setting.
To change from monitor mode to control mode
To change from monitor mode to controller mode, press either the ‘+’ or’ –‘ key on the SCT1 temperature controller once. The unit will revert to controller mod, and will be indicated by the illuminated amber contact thermometer indicator
visible on the front panel of the hotplate. The red LED on the bottom right hand corner of the SCT1 temperature controller display will extinguish when the unit is in controller mode.
NB: For safety reasons, when reverting from monitor to controller mode the SCT1 temperature controller will default to the set point temperature of 20°C.
Troubleshooting
In the event of malfunction the SCT1 temperature controller can self-diagnose certain fault conditions. In this case the display will show a message in the form of ‘Err XX’ where XX is either a single or double digit code, which identifies the fault.
Error code Fault condition Remedy
Err 1 Thermometer not calibrated Return to factory
Err 2 Electronic fault Return to factory
Err 4 Probe plug removed Reconnect probe. in control or monitor Continuing error mode code indicates hotplate fault ­ return to factory
Err 8 Probe out of sample Replace probe in when in control sample mode
Err 16 Ambient temperature Switch off at inside hotplate too 'mains' and allow high (controller to cool attached)
Servicing and Repair
WARNING: Ensure the hotplate is disconnected from the mains electricity supply before attempting maintenance or servicing.
This equipment does not require routine servicing. The only maintenance required is to clean external surfaces with a damp cloth and
5
mild detergent. Spillages or splashes should be cleaned up straightaway after isolating the hotplate from the mains electricity supply.
Repairs
In the event of product failure it is recommended that any repair is only undertaken by suitably qualified personnel.
Only spare parts supplied by Bibby Scientific or its agent should be used. Fitting of non-approved parts may affect the performance of the safety features of the instrument.
For a comprehensive list of parts required by service engineers conducting internal repairs, or to receive a service manual, please contact the Service Department of Bibby Scientific Ltd quoting both the model and serial number.
Bibby Scientific Ltd. Stone, Staffordshire ST15 0SA United Kingdom Tel: +44 (0)1785 810475 Fax: +44 (0)1785 813748 E-mail: service@bibby-scientific.com www.bibby-scientific.com
For any other technical enquiries, please contact the Technical Support Department: E-mail: stuarthelp@bibby-scientific.com, Tel: +44 (0)1785 810433.
Accessories
A range of accessories detailed below is available for use with the SCT1 temperature controller.
Warranty
Bibby Scientific Ltd. warrants this equipment to be free from defects in material and workmanship, when used under normal laboratory conditions, for a period of three (3) years. In the event of a justified claim, Bibby Scientific will replace any defective component or replace the unit free of charge.
This warranty does NOT apply if damage is caused by fire, accident, misuse, neglect, incorrect adjustment or repair, damage caused by installation, adaptation, modification, fitting of non-approved parts or repair by unauthorised personnel.
Bibby Scientific Ltd. Beacon Road, Stone, Staffordshire ST15 0SA United Kingdom Tel: +44 (0) 1785 812121 Fax: +44 (0) 1785 813748 E-mail: equipment@bibby-scientific.com www.stuart-equipment.com
Technical Specification
Probe Stainless steel
Temperature range ºC 20 to 200ºC Accuracy, ºC ±0.5ºC Resolution 1ºC Dimensions, mm (w x d x h) 90 x 75 x 123 Net weight, kg 0.3 (inc. probe) IP rating 54
Part code Description
SCT1/1 Probe holder SCT1/2 PTFE probe SR1 Retort rod SCT1/MP Spare metal probe
6
Français
temperature controller
SCT 1
C
heat-stir
US152
HOT
1
2
3
4
5
6
7
8
9
STIR
undergrad
off
Power on/off
100
150
250
200
300°C
50
HEAT
HEAT
STIR
HOT
100
50
Power on/off
heat-stir
US152
150
200
250
4
3
2
1
off
5
6
7
US152
HOT
1
2
3
4
5
6
7
8
9
STIR
undergrad
off
Power on/off
100
150
250
200
300°C
50
HEAT
Power on/off
100
150
250
200
300°C
50
HEAT
Figure 1 Vu de face
Support de la sonde
Fiche du contrôleur
Figure 3 Vue de face de la plaque chauffante
Témoin de thermomètre de contact
Témoin d'avertissement 'Hot'
Témoin d'agitation activée
Sonde de température
Figure 2 Vue arrière
Connecteur de la sonde
Fiche de la sonde
Bague de verrouillage
Figure 4 Vue arrière de la plaque chauffante
Pince à mâchoires
Fixation de tige de statif
Contrôle de la température
Connecteur de sonde DIN
Interrupteur
Contrôle de l'agitation
marche/arrêt d'alimentation (sauf sur unité d'agitateur seul)
Douille d'alimentation IEC pour fiche haute température
5
Contrôleur de température
SCT1 Manuel d'utilisation
Introduction
Nous vous remercions d'avoir fait l'acquisition de cet équipement Stuart. Pour profiter au mieux de ses performances, ainsi que pour votre sécurité, lisez attentivement ces instructions avant toute utilisation. Avant de jeter l'emballage, vérifiez que tous les éléments sont présents et en bon état.
Description générale
Le contrôleur de température Stuart SCT1 est l'équipement idéal pour contrôler de manière précise la température des échantillons aqueux et à base d'huile, en laboratoire. Il peut s'utiliser de deux manières différentes : en tant que contrôleur de température de précision entre 20 et 200 °C ou en tant que thermomètre numérique entre -4 et 325 °C. Grâce à son réglage et à son affichage numériques de température, il permet une précision de l'ordre de ± 0,5 °C.
Le contrôleur de température SCT1 est compatible avec les plaques chauffantes et les agitateurs chauffants Stuart suivants : US150, US152, US152D, UC150, UC152, UC152D, SC162 et CC162.
Consignes de sécurité avant utilisation
En cas de non respect des consignes
détaillées dans ce manuel ou
d'utilisation avec des accessoires différents de ceux recommandés par Stuart, la protection intégrée est susceptible de se révéler inopérante.
Cet appareil est conçu pour fonctionner dans les conditions suivantes :
❖ Utilisation en intérieur uniquement ❖ Utilisation dans un lieu correctement ventilé
❖ Température ambiante de +5 à +40 ºC ❖ Altitude maximale de 2000 m ❖ Taux d'humidité relative de 80 % maximum ❖ Ménager un espace minimum de 200 mm
autour de l'appareil par rapport aux murs et aux autres équipements.
❖ Ne jamais déplacer ou transporter l'appareil
en cours d'utilisation ou lorsqu'il est connecté à la plaque chauffante.
❖ Ne pas utiliser en atmosphère dangereuse ou
en présence de substances dangereuses.
Préparation à l'utilisation
Pour utiliser le contrôleur de température SCT1 avec une plaque chauffante avec surface de pose en métal ou en céramique, placez la plaque chauffante sur une surface plane et ferme.
Ouvrez les mâchoires de la pince, à l'arrière du contrôleur de température SCT1, en faisant tourner le bouton de la pince dans le sens antihoraire. La pince peut s'utiliser avec des tiges de statif d'un diamètre allant de 9,5 à 13 mm. Faites glisser le SCT1 sur la tige de statif et serrez la pince en faisant tourner son bouton dans le sens horaire.
REMARQUE : PAS DE SERRAGE EXCESSIF.
Connectez la fiche du contrôleur SCT1 au connecteur DIN, à l'arrière de la plaque chauffante (figures 1 et 4).
Connectez la fiche de la sonde au connecteur situé à l'arrière du contrôleur (figures 2 et 4).
Pour assurer un branchement optimal, serrez la bague de verrouillage de la fiche en la faisant tourner dans le sens horaire.
Branchez le cordon d'alimentation secteur au connecteur IEC situé à l'arrière de la plaque chauffante et connectez-le à l'alimentation secteur. Si l'unité est dotée d'un interrupteur marche/arrêt, mettez-la sous tension à l'aide de cet interrupteur.
Pour allumer le contrôleur de température SCT1, faites tourner le bouton de réglage de température de la plaque chauffante dans le sens horaire (figure 3).
6
REMARQUE : le contrôleur est alimenté par
temperature controller
SCT 1
C
la plaque chauffante.
Le contrôleur de température SCT1 et la plaque chauffante sont désormais prêts à l'emploi. Le voyant orange du thermomètre à contact situé en façade de la plaque chauffante s'allume pour indiquer que la communication entre le contrôleur de température SCT1 et la plaque chauffante est correcte.
REMARQUE : la plaque chauffante et le contrôleur effectuent un test automatique au moment de leur mise sous tension, avant d'afficher la température en cours de la sonde. Par défaut, la température est réglée sur 20 °C.
Utilisation
Installation du contrôleur
Le contrôleur de température SCT1 est fourni avec une sonde de température amovible (figure2). Cette caractéristique utile permet de le tenir éloigné des émanations susceptibles de l'endommager.
Par défaut, la pince à mâchoires du contrôleur de température est positionnée de manière à permettre un montage sur une tige de statif verticale. Pour installer le contrôleur de température SCT1 sur une tige de statif horizontale, faites effectuer une rotation de la pince située à l'arrière du contrôleur de manière à présenter la partie à angle droit en haut. Faites tourner la pince de 90° dans le sens horaire jusqu'à ce qu'elle s'enclenche à nouveau.
Positionnement de la sonde
Pour une mesure optimale de la température, assurez-vous que l'extrémité de la sonde se trouve à une profondeur d'au moins 20 mm dans l'échantillon contrôlé. Lorsqu'elle n'est pas utilisée, la sonde de température doit être placée dans le support de sonde situé à gauche du panneau de commande du SCT1. Pour des raisons de sécurité et pour éviter toute contamination, essuyez toujours la sonde avant de la placer dans son support.
Utilisation du contrôleur de température SCT1
Le SCT1 peut s'utiliser de deux manières différentes : en tant que contrôleur de température (« mode contrôle ») ou en tant que thermomètre numérique (« mode affichage »).
Utiliser le SCT1 en mode contrôle
Assurez-vous que le contrôleur de température SCT1 est connecté à la plaque chauffante. Assurez-vous également que la sonde de température est connectée au contrôleur et plongée dans l'échantillon à contrôler avant de mettre l'équipement sous tension.
US150, US152, US152D, UC150, UC152 et UC152D
Mettez l'unité sous tension à l'aide de l'interrupteur marche/arrêt situé sur le côté. Le SCT1 s'allume en mode affichage. Pour basculer le contrôleur de température en mode contrôle, faites tourner le bouton de réglage de la température situé en façade de la plaque chauffante dans le sens horaire. Sur les modèles numériques, l'écran LED affiche le message « --- ».
L'état actif du mode contrôle du SCT1 est indiqué par l'allumage du voyant orange du thermomètre à contact en façade de la plaque chauffante (figure 3). Le voyant et l'affichage sont visibles sur le panneau du contrôleur de température SCT1 (figure 5) et la température de l'échantillon est affichée.
DEL du thermomètre
Augmentation de la consigne de température
Diminution de la consigne de température
Figure 5 : Panneau du contrôleur de température SCT1
7
CC162 et SC162
Un voyant vert s'allume en façade de la plaque chauffante. Pour mettre le contrôleur de température sous tension, faites tourner le bouton de réglage de température en façade de la plaque chauffante dans le sens horaire. Le mode contrôle du SCT1 est indiqué par l'allumage du voyant orange du thermomètre à contact en façade de la plaque chauffante (figure 3). Le voyant et l'affichage sont visibles sur le panneau du contrôleur (figure 5) et la température de l'échantillon est affichée.
REMARQUE : faire tourner le bouton de réglage de température de la plaque chauffante dans le sens horaire fait basculer le contrôleur SCT1 en mode contrôle, mais ne règle pas la température de la plaque chauffante.
Pour régler la température en mode contrôle
Appuyez une fois sur la touche + ou - pour activer le mode Point de consigne de température. L'activation est indiquée par un voyant clignotant sur l'écran du contrôleur SCT1. Pour sélectionner la température souhaitée, utilisez la touche + ou -. Pour valider la température, relâchez la touche. Le voyant cesse de clignoter une fois la température définie. Lorsque la sonde est placée dans le liquide, le voyant du thermomètre s'allume comme suit :
❖ Vert : point de consigne de température
non atteint
❖ Orange : température du liquide au point
de consigne
❖ Rouge : température du liquide
supérieure au point de consigne
Remarque : pour garantir la précision de la mesure de la température, le point de consigne de température minimum doit être supérieur d'au moins 15 °C à la température ambiante.
Utiliser le SCT1 en mode affichage
US150, US152, US152D, UC150, UC152 et UC152D
Pour utiliser le contrôleur SCT1 en mode affichage avec la plaque chauffante, assurez-vous que l'unité est hors tension à l'aide de l'interrupteur marche/arrêt situé sur le côté. Appuyez simultanément sur les touches + et - du contrôleur et, tout en les maintenant enfoncées, réglez placez l'interrupteur marche/arrêt sur marche (« ON »). Une fois l'écran numérique allumé, relâchez les touches du contrôleur de température SCT1. Le mode affichage est indiqué par un voyant rouge clignotant dans l'angle inférieur droit de l'écran du contrôleur. Le voyant de contrôle orange de la façade de la plaque chauffante ne s'allume PAS en mode affichage.
CC162 et SC162
Pour utiliser le contrôleur SCT1 en mode affichage, assurez-vous que la plaque chauffante est hors tension en faisant tourner le bouton de contrôle de température de la plaque chauffante dans le sens antihoraire, jusqu'à la position arrêt (« OFF »). Appuyez simultanément sur les touches + et - du contrôleur de température SCT1 et, tout en les maintenant enfoncées, placez le bouton de contrôle de température sur marche (« ON »). Une fois l'écran numérique allumé, relâchez les touches du contrôleur. Le mode affichage est indiqué par un voyant rouge clignotant dans l'angle inférieur droit de l'écran du contrôleur. Le voyant de contrôle orange de la façade de la plaque chauffante ne s'allume PAS en mode affichage.
REMARQUE : lorsqu'il se trouve en mode affichage, le contrôleur de température SCT1 fonctionne uniquement en tant que thermomètre numérique et ne contrôle plus la température du liquide. La température de la plaque chauffante peut alors être réglée manuellement sur la valeur souhaitée.
Passer du mode affichage au mode contrôle
Pour passer du mode affichage au mode contrôle, appuyez une fois sur la touche + ou ­du contrôleur de température SCT1. L'unité repasse en mode contrôle et ceci est indiqué par le voyant orange du thermomètre à contact
8
Loading...
+ 22 hidden pages