Striking energy G2 2000 R, G2 3000L R, G2 4000L R, G2 1500 LG, G2 3000L LG Instruction Manual

...
INSTRUCTION MANUAL
Safety Cautions:
Fixed Installation
The appliances must be installed by a qualified electrician according to the legal regulations as published.
If the heater is installed without a plug, or with other means for disconnection
from the supply, a double pole isolator should be used.
The heater must not be installed in a recessed area. It must always be surface mounted and allow for proper ventilation. Do not allow any heat build-up.
The minimum ventilation openings around the heater, after installation, must be 150mm from the top and sides and at least 1500mm away from any combustible materials (curtains, paper etc)
Remove the foam that protects the lamp during transit before operating the heater.
The heater MUST be installed above 1800mm from the floor surface.
Ensure that the heater is properly fixed using the supplied swivel bracket.
Permanent wall plugs and or screws should be used.
Do not use any form of adhesive tape or temporary fixing.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
When installed in a bathroom / Jacuzzi area, installed in such a way that the heater, switches and other controls cannot be touched by a person in the bath
Installation on a portable stand
Do not use this heater in the immediate surroundings of a bath, a shower or a swimming pool.
DO not use the portable stand indoors or near any combustible materials, couches, carpets etc.
Ensure that the electrical cable is secure and not crossing any walkways.
Safety Cautions: Operation
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
!
www.striking.co.za
!
Infrared Space heaters
Models:
G2!1500!R!
G2!1500!LG!
G2!2000!G!
G2!2000!R!
G2!3000L!LG!
!
G2!3000L!R!
!
!
G2!4000!R!
!
G2!4000L!G!
!
Children should be supervised to ensure that they do not play with the appliance.
Do not cover or obstruct the heater at any time
Do not use this heater with a programmer, timer, separate remote-control
system or any other device that switches the heater on automatically, since a fire risk exists if the heater is covered or positioned incorrectly.
The fireguard grill does not give full protection for young children and for infirm persons.
Do not insert any object through the front grid or opening in the heater.
Do not leave the heater unattended. Always switch off before leaving the
room/area.
Do not stare at the element while switched on. Prolonged starring at the element can cause damage to the eyes.
Keep combustible materials such as furniture, papers, clothes and curtains at least 1500mm away from the front of the heater.
The heater can be used outside BUT must be sheltered from any rain / water.
The heater is NOT waterproof.
Disconnect from the mains during installation, cleaning and/or replacing the
element.
To avoid risk of burns, always ensure that the element and heater body had time to cool down before cleaning.
Do not handle the halogen element with bare hands. If it is inadvertently touched, remove finger marks with a soft cloth and methylated spirit or alcohol. Otherwise, the marks will burn into the element causing premature heater failure.
Do Not touch the element with any object (incl. cigarette)
Installation
Remove the heater from the packaging
Remove the protected foam behind the element inside the heater. Be sure NOT
to touch the element with bare hands
Remove the 2 x 6mm hex bolts both sides of the swivel bracket at the back of the heater.
Position the U shaped portion of the swivel bracket with the 2 x 6mm holes at the correct position as per the safety instructions under paragraph 1.
Fix the U shaped portion permanently with either 2 x plastic wall plugs and screws in the wall or ceiling or 2 x screws in wood through the 2 x 6mm holes on the swivel bracket
Re-attached the heater to the swivel bracket with the 2 x 6mm hex bolts.
Focus the heater in the desired position and tighten the bolts.
Connect the electrical wire to the supply.
The recommended installation height is as follows:
1500, 2000 watt models: 1800 – 2500mm above floor height
3000, 4000 watt models: 2500mm – 4000mm above floor height
Cleaning the heater
Ensure that you have disconnected the heater from the electrical supply and that the units has sufficiently cooled down
If it is only dust on the inside, you may clean the inside by blowing compressed air over the surface.
Remove the fire grid in front of the heater by pulling it carefully to the front. Unclip one side first.
General dishwasher soap and water will clean the inside and outside of the body.
Be sure not to touch the element with bare hands.
Should you accidentally touch the element, clean the element with a paper
towel dipped in either an alcohol or cutex remover (acetone). Any fatty / soapy marks on the element will permanently damage the element when switched on.
Clean the inside of the heater at least annually to remove any dust and dirt build-up. This will ensure optimal reflection of the infrared beams.
Replacing the element
Tools required: Pliers, 2.5mm and 4mm Allen Key, Philips screwdriver.
1. Disconnect the power supply and ensure that the element is not illuminated and that the heater body and element are cool.
2. Unscrew the 2 screws on the electrical gland (metal part where the electrical cable enters the heater) until the wire can move freely.
3. Unscrew the 4mm and 2 x 2.5mm Cup screws on the side plate opposite to the electrical connection
4. Optional: You could remove the grid by pressing in the center and unclip it or slide it out to the side.
5. Slowly pull the lamp slider out of the body (the piece of aluminum that holds the element) while feeding the electric cable.
6. Be careful not to pull to hard on the cable.
7. Unscrew the two ceramic connectors at the back and separate the two wires that were connected by the connectors.
8. Remove the old element from the clips by closing the split pins with the pliers.
9. Remove your new element from it’s box and cut and clean the wires to the same length is the old element.
10. Slowly and carefully insert the new element into the clips. BE CARE FULL NOT TO TOUCH THE ELEMENT WITH YOUR BARE HANDS. Use gloves / tissue paper if necessary.
Assemble
1. Replace the split pins and bend open.
2. Connect the new wires with the same ceramic connectors. Ensure that they “screw / cut” into the new wires for a secure connection
3. Feed the cable back through the gland from the inside.
4. Slide the lamp holder back into the body, while pulling on the electrical cable
5. Secure the side plate with the 3 cup screws, Tighten the cable and replace the grid.
Technical Specifications
Heater Dimensions
Models
G2 1500 R G2 2000 R G2 3000L R G2 4000L R
G2 1500 LG G2 3000L LG
G2 2000 G G2 4000L G
LampType / Wattage
385mm Short Body
785mm Long Body
Ruby Red
1500 watt 2000 watt
3000 watt 4000 watt
Gold
2000 watt
4000 watt
Ultra Low Glare
1500 watt
3000 watt
Material
Aluminium (6063,1200H4), Stainless Steel 304 Safety grid: Electro polished Stainless Steel
Electrical requirements
230 Volt 50 Hz 1500watt – 7 Amp 2000watt – 9 Amp
230 Volt 50 Hz 3000watt – 14 Amp 4000watt – 18 Amp
Overall Dimensions (Width x Height x Depth)
385 x 114 x 100mm
785 x 114 x 100mm
Burning position
Horizontal as well as vertical position.
Element Life
Half life of 5000 hrs rated by manufacturer
Electrical Cable
3 Core 1,5mm Silicone heat resistant cable. Open ended
Warranty
5 Years on body
3 Core 2,5mm Silicone heat resistant cable. Open ended
Heating Element
Model&
A&(& mm&
B&(& mm&
Voltage&
Wattage&
Cap& Base&
Burining& Position&
Half& Life& Hrs&
1500&LG&
350!
280!
230!
1500!
SK!15!
Universal!
5!000!
1500&
Helen&
350!
280!
230!
1500!
SK!15!
Universal!
5!000!
1500&Ruby&
350!
280!
230!
1500!
SK!15!
Universal!
5!000!
2000&Gold&
350!
280!
230!
2000!
SK!15!
Universal!
5!000!
General
Features
5 Year warranty on the body
Integrated uni-body reflector
Manufactured in South Africa. Parts available locally.
Unique reflector design resulting in cost effective heat reflection.
High grade Aluminium and Stainless steel construction. No powder coated mild
steel that chip rust and flake.
Applications
Restaurants & Hotels,
Homes, Bathrooms, Patios
Schools, Halls
Factories, warehouses
Greenhouses and other Agricultural
The latest version and instructions available on www.striking.co.za VERSION 1.1. March 2014 © Striking Energy
Loading...