Streamax X5-E0804, X5-E0408 User Manual

Page 1
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
User Manual
For
X5-E0804/E0408 MDVR
Mobile Digital Video Recorder
Copyright 2013-2015, Streamax Technology Co., Ltd
Page 2
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
Notice
The information in this manual was current when published. The manufacturer reserves the right to
revise and improve its products. All specifications are therefore subject to change without any notice.
The purpose of this manual is to kindly aid the user for the operation for our MDVR. The user should
have a basic understanding of computer operation and basic knowledge of how to connect peripherals
and make some settings.
Copyright
Under copyright laws, the content of this manual may not be copied, photocopied, reproduced,
translated or reduced to any electronic medium or machine- readable form, in whole or in part, without
prior written consent of Streamax Technology Co., Ltd (Copyright 2013-2015)
Page 3
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
1
Guarantee & Warnings
1) Electrical Apparatus Safety
All installation and operation should comply with local electrical safety norms.
2) Transportation
In the process of transportation, storage and installation, please avoid heavy stress, violent vibration,
impact and water splashing.
3) Installation
Install the equipment in accordance with the requirements, handle carefully. Do not heavily press the
equipment before the MDVR installation is finished.
4) Requirements on Engineers & Technicians
All the work of checking and maintenance should be done by qualified technicians and engineers.
We do not undertake any responsibility caused by unauthorized modifications.
5) Requirements on Environment
The equipment should be installed and stored in a cool and dry place, away from direct sunlight,
flammable or explosive substances, etc. Keep gaps not less than 3cm around the device to facilitate
ventilation for cooling.
6) Accessories
Make sure to use accessories from the manufacturer recommended in the attachment.
Insulate circuit ground and metal shell for all the peripherals.
Before installation, please open the package and ensure that all parts are included.
If there are any problems, please contact us as soon as possible.
Page 4
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
2
Contents
1. PRODUCT CHARACTERISTICS......................................................................................................................3
1.1. OVERVIEW.........................................................................................................................................3
1.2. FEATURES......................................................................................................................................... 3
1.3. FUNCTIONS.......................................................................................................................................3
1.4. SPECIFICATIONS.............................................................................................................................4
1.5. SYSTEM DIAGRAM..........................................................................................................................5
1.6. EXTERNAL INTERFACE................................................................................................................. 6
2. SETTING..............................................................................................................................................................8
2.1. REMOTE CONTROL PANEL.......................................................................................................... 8
2.2. CP4 CONTROL PANEL....................................................................................................................9
3. OPERATING INSTRUCTIONS........................................................................................................................10
3.1. LOCAL LOGIN..................................................................................................................................10
3.2. RECORD SEARCH AND EXPORT:............................................................................................. 12
3.3. LOG SEARCH AND EXPORT.......................................................................................................14
3.4. SYSTEM STATUS........................................................................................................................... 16
3.5. BASIC SETUP..................................................................................................................................17
3.5.1. REGISTER INFOMATION (SETUP VEHICLE INFORMATION).....................................17
3.5.2. TIME SETUP............................................................................................................................18
3.5.3. START UP.................................................................................................................................19
3.5.4. USER SETTING...................................................................................................................... 20
3.5.5. NETWORK SETTINGS.......................................................................................................... 22
4. VIDEO SURVEILLANCE.................................................................................................................................24
4.1. REAL-TIME SURVEILLANCE....................................................................................................... 24
4.2. RECORD...........................................................................................................................................26
4.3. IPC SETUP....................................................................................................................................... 28
4.4. DATA COLLECTION........................................................................................................................29
4.5. ALARM.............................................................................................................................................. 30
4.6. MAINTENANCE...............................................................................................................................32
4.6.1. CONFIGURATION...................................................................................................................32
4.6.2. DATA EXPORT.........................................................................................................................33
4.6.3. UPGRADE................................................................................................................................ 33
4.6.4. STORAGE.................................................................................................................................34
4.6.5. DEFAULT.................................................................................................................................. 34
5. REFERENCE APPENDIX.................................................................................................................................35
5.1. STORAGE CAPACITY CALCULATION.......................................................................................35
5.2. FREQUENTLY ASKED QUESTIONS.......................................................................................... 36
Page 5
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
3
1. PRODUCT CHARACTERISTICS
1.1. OVERVIEW
X5-E0804/E0408 is an advanced and function-extensive Mobile Video Recorder specially designed
for network high definition, analog audio & video input and excellent extension. It uses high-speed
processor and embedded operating system, combining with H. 264 video compression / decompression
technology, network technology and GPS locating technology. It can realize 720P high definition, CIF,
HD1, D1, WD1 video recording and vehicle driving information recording, as well as wireless data upload.
With center software it also achieves alarm linkage central monitoring, remote management and
playback analysis. It is powerful with modular design, flexible installation, easy maintenance and high
reliability.
1.2. FEATURES
1) All the modules are connected with exquisite connectors, supporting quick disconnection,
which is safe and easy to maintain.
2) The machine will alarm automatically when each modules have faults the modules are in
errors.
3) Waterproof With sealed waterproof design for the shield.
4) Combines physical, electrical and software anti-vibration
5) Supports DC6~36V wide voltage input; suitable for 12V and 24V vehicle.
6) Adapts dynamic coding technology to adjust the change of 3G network and ensure the fluency
of monitoring video.
7) Watermark technology: prevent data tampering and guarantee the video authenticity and legal
efficiency.
1.3. FUNCTIONS
1) Local recording and video playback: D1/HD1/CIF resolution optional.
2) Driving recording: provide statistics on speed, turning, brake, reverse, opening door, etc.
3) Network function: support break point uploading continually, which can realize the remote
video surveillance, video download, remote alarming and network timing of the equipment,
network setting and remote upgrade, etc.
4) High-speed backup: support high-speed backup through USB2.0, as well as backup through
SD card.
5) User log: on-off status of the device, video loss, recording start time / end time, user log in / log
out, modification of the device parameters, timing, bus stop announcement and GPS status.
6) Import and export of the configuration file: U disk import/export device parameters.
7) Device upgrade: support local and remote upgrade.
8) Alarm linkage: support linkage switch value output, image display, etc.
9) Storage formatting: formatting device hard disk and external USB devices.
Page 6
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
4
1.4. SPECIFICATIONS
Function Overview
Preview, Recording, Playback, Network, Locating
System
OS
Linux 3.0.8
Control Mode
CP4, Easy Check, IR Remote Control, Network,Mouse
Video
Input
8channel WD1+4channel IPC(720P) or
4channel WD1+8channel IPC (720P)
Output
2 channels
Total Resource
(8 x 25)FPS WD1 @ PAL / (8 x 30)FPS WD1 @ NTSC +(4 x
30)FPS 720P or
(4 x 25)FPS WD1 @ PAL / (4 x 30)FPS WD1 @ NTSC +(8 x
30)FPS 720P
Video Signal Standard
Electrical level: 1Vpp Impedance: 75Ω NTSC/PAL Optional
Audio
Input
8channels(12 channels if connects with IPCX4)
Output
2channels
Audio Signal Standard
Electrical level: 2Vpp Input impedance: 4.7kΩ
Display
Display Split
1/4/9 Image display
OSD
GPS information, alarm, temperature, acceleration, voltage,
device information, software version, MCU version, network
status
Operation Interface
Semi-transparent GUI
Recording
Video/Audio
Compression
H.264/ADPCM
Image Resolution
Analog:
PAL:WD1(928X576), WHD1(928X288), WCIF(464X288),
D1(704X576), HD1(704x288), CIF(352x288);
NTSC:WD1(928X480), WHD1(928X240), WCIF(464X240),
D1(704x480), HD1(704x240), CIF(352x240);
Digital:
720P(1280X720);
Image Quality
8 Levels adjustable
Recording Mode
Manual/schedule/Alarm(sensor trigger,
speed, acceleration, video loss, temperature)
Pre-recording
0-60minutes
Post-recording
0-30 minutes
Mirror Recording
Yes
Playback
Playback Channel
1/4 channels by local playback
Search Mode
Date/time, channel, event
Network
3G/4G
EVDO/WCDMA/TDD-LTE/FDD-LTE
Locating
GPS
Location tracking, speed detection and time sync
Storage
Hard disk
Supports 2.5" hard disk up to2TB
Interface
USB
USB2.0 x 2
SD
SD x 1
Page 7
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
5
RS232
RS232 X 2
RS485
RS485 X 2
Sensor
8 inputs, 2 outputs
Serial
G-sensor (Internal)
Speed
1 channel pulse speed detection
Interface
Interface (CP4) Optional
Power
Input
DC8-36V
Output
1A@12V,1A@5V
Physical
Characteristics
Dimension(L x W x H)
295 x 222 x 89 mm
Others
Water Proof Rate
IP54
1.5. SYSTEM DIAGRAM
Diagram1 (POE Switch RJ45)
Page 8
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
6
Diagram 2 ( POE Switch Aviation-din)
1.6. EXTERNAL INTERFACE
1) Dimension (Unit: mm)
Page 9
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
7
2) Front Panel and Rear Panel
Page 10
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
8
2. SETTING
2.1. REMOTE CONTROL PANEL
Remote control key directions
ON/OFF
1when the password is turn off, in
preview screen, press this bottom
standby(soft start key), press again
the device turn on. 2When the password is enabled,
in preview screen, press this key
password prompt box appears,
enter the administrator password to
restart the machine (soft-start key).
LOAD/LOCK
When the device has password
and press Login / Lock key to enter
the password.Because the system
does not recover and reset the
password function, please
remember the password.
ADJUSTMENT
Brightness, contrast, color, hue
adjustment, in single screen, with
[+], [-] keys to adjust the user can
be independently adjusted for each
channel
SETTING
Set menu key (when the password
is enabled, you can log on by using
this key)
BACK
Return to the previous submenu.
Eventually exit the setup menu and
exit to the monitor screen
PAUSE/FRAE
OUTPUT
Pause and frame output bottom
when playback can play one frame
each time, press the playback
button to return to normal playback
speed
PLAY
Start the play button (pause screen
is displayed when a still picture)
SLOW PLAY
Slow play button when the
playback image data, there are
third class: 1 / 2,1 / 4,1 / 8, and then
a return to normal playback speed
Page 11
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
9
FAST
FORWARD
Fast forward button during
playback image data, three class:
2X, 4X, 8X
REWIND
Rewind button during playback
image data, three class: 2X, 4X, 8X
STOP ■
Stop manual recording button
RECORD ●
Start manual recording button
DOWN ▼
During playback, turn the page /
next file
UP ▲
During playback, turn to previous /
previous document
TPZ
FUNCTION
Automatic, presets, called, zoom +,
zoom -, zoom +, zoom - iris +, Iris -
F1
Alarm Recording Export Shortcuts
F2
Start the PTZ function bottom
F3
Play bottom by time choose
F4
Spare key
2.2. CP4 CONTROL PANEL
Repeat
Repeat station notification
Station
Notification
Station notification bottom
0-9
Number enter key
Confirmation
Confirmation key
Back
Back from the menu
Direction
Up / Down / Left / Right selection key
Page 12
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
10
Operation Instrument
Remark:
When reporting to CMS server, use serial number.
When using Android pad, you need to select vehicle number, as when insert the wifi hot spot to USB port
of the 4120, the hot spot will get the vehicle number and change its SSID to vehicle number.
3. OPERATING INSTRUCTIONS
3.1. LOCAL LOGIN
When operating the device, user needs to have permission certified.
1) Press the remote control LOGIN / LOCKorSETUP, the login screen will pop up.
2) Right click the mouse, the shortcut menu will pop up, left click login picture, login screen will pop up.
3) Left click on the login button to login and right click to log out
Login Notice
1) Software is automatically assigned by user name and password, it can be divided into user and
administrator privileges.
2) Password options can not be closed, but it can be set to null; when it is empty, user do not need to
enter the password to login
Login interface Introduction
User name
1) Select users from the drop-down box. There are admin and user as defaults.
2) Currently, it can show two users and one admin.
Password
Page 13
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
11
1) User can enter the operation interface if entering the right password;
2) User must enter the right password again if entering the wrong ones;
3) Click cancel to exit the login interface;
Language
1) Support the language switch. "language" (Lang) means the current interface adopts Chinese;
2) It will automatically switch once Selecting the language.
3) Currently, it supports Chinese and English;
4) After switching languages, it will not restore language option when user restores the factory
Settings;
Default password and permission table is as follows:
Default Password
Related User
Related Authority
admin
admin
All Authorities
User
user
Search and playback
The password input Instruction
1. If the password are numbers, user can enter it by remote control directly.
2. User can click ENTERor the left click mouse on the remote control.
a. Move the cursor to the number position, press Enter or left click mouse button to select the
corresponding number.
b. Move the cursor to 123, press Enteror mouse to choose input type, such as
the Numbers, letters, or special characters. abmeans lower case letters,【123】means numbers,【AB】means capital letters; the highlighted
place of background refers to the current cursor position.
c. Move Cursor to , Press【Enter】or left click mouse to move between the contents that have
entered.
d. Move Cursor to , Press 【Enteror left click mouse to delete the previous input contents.
e. Move Cursor to , Press Enteror the left click mouse to exit the keypad, the entered
contents will be written to the edit box.
Page 14
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
12
f. Move Cursor to【Escposition, Press【Enter】or the left click mouse to exit the keypad, the entered
contents will not be written to the edit box
3.2. RECORD SEARCH AND EXPORT:
Video search interface contains video file search, video data backup and video playback function.
When there is a hard disk or SD card, enter the video search interface. Following is the REC Search
interface:
In the calendar, the color below the dates means:
a. No color means no video.
b. Green means common video.
c. Red means alarm video.
d. Yellow means there are alarms and the video files are automatically lock (lock video).
Source: select the source of the video, there are main video, sub video and mirror video.
The main record means HDD record while sub record and mirror record are dual-stream records.
Select the date with record, click next, then enter the following interface:
Following is the record search detail and record search result interface:
Record search detail interface
Record Type: User can choose all record, alarm record or normal record.
Channel chooseThe channel is optional and mark with color that has record. The channel
with gray cannot be chosen if there is no record. As to different record type, it will show different
relates.
Click search button in the record search detail page, user can enter then record search result page.
Page 15
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
13
Time Bar: Time bar shows three time points, 0 o'clock, 12 o'clock, 24 o'clock. It shows what
type of videos during the time according to the marked channel.
Channel No: According to the situation of video for each channel video the day , the video will
be displayed on the time line. Tick the channel if user wants to playback the video.
Note: channel number is displayed from 1~20, please up page up/page down button to
change channel
Button description
Video playback: Choose the channel No., select start time to play < default start from 0 >, click
the playback button to playback the video.
In playback interface, user can choose fast forward or fast backward to play the video, the button in the
middle of screen can switch the channels. The image stops and it will not exit automatically when
playing to the last video of the day.
Time period settings: Click the time setting button, select start time and end time, it will backup or
playback the video in the selected time period. Click clip to export the video, the file format can
be.264< comprehensive file >, also can be.avi format.
Page 16
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
14
Video export: Select the channel that has the video files, click this button, all the video files in
the effective time period will be exported to the external USB peripherals, file format can
be.264<comprehensive file >, also can be avi format.
User can also pull out the hard drive or SD card, export and playback the video by professional software.
3.3. LOG SEARCH AND EXPORT
In the log search interface, it records and displays all alarm events and login operation log. Enter the
"log query”, the interface will be shown as following :
Log Search interface instruction:
Calendar: the date with log will be marked on the calendar with green color.
Remark: There is no color classification in the “log mark”, and all are green ones.
Page 17
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
15
Log search interface instruction:
Start time: the start time for searching log files
End time: the end time for searching log files
Log types: classification of log search, including the operation log and alarm log and locking log
Operation log search interface instruction
Log includes the following information:
Log time: the time when event is triggered
Log name: event content
Supports page up/page down and export all log files of the specified date.
Do not support link to video file.
Log search
Alarm type: It includes all alarms, IO alarm , panic alarm and over speed alarm.
Log includes the following information:
Log time :the time when event is triggered
Log nameevent content
Supports page up/page down and export all log files of the specified date.
Supports link to video file, click on button to playback video files
Lock log search
Log includes the following information:
Log time: the time of when event triggered.
Log name: event content
Log will be recorded according to channel number, each channel will have a lock log file.
Support page up and page down.
Can’t export all log files of the specified date.
Can link to video file, click on button to playback video files.
Unlock: Select log, and unlock it. Then the alarm log of lock will be cleared.
Remark:
When lock the video file, system will record alarm log and lock log. The locked video file can only be
unlocked from alarm log.
Page 18
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
16
3.4. SYSTEM STATUS
User can login the interface with no access restrictions.
System- Version information
System- Modules
System-Server status
Page 19
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
17
System - Environment
System-Storage:
3.5. BASIC SETUP
Click setup button and enter the following interfaces:
3.5.1. REGISTER INFOMATION (SETUP VEHICLE INFORMATION)
Register information-Device info:
Device ID: Currently, it is not useful.
Page 20
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
18
Register information- Vehicle info
Vehicle NumberWhen connected with PAD, the vehicle number is needed.
Vehicle plateInput manually.
Line numberInput manually.
Register information—About the driver’s information:
Driver number: Input manually.
Driver name: Input manually.
3.5.2. TIME SETUP
Page 21
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
19
Time setup-General
Date format: Setup the date format of device
Time format: 24 hours or 12 hours
Time zone: Range from -12thdistrict ~ +13thdistrict
Time-Time Sync
Date/Time: Device time, from 2000-01-01 to 2037-12-31
Satellite: Synchronize time with GPS satellite. Once GPS signal changes to valid, device will
synchronize time
Center Server: synchronize time with center server
NTP server: synchronize time with NTP server
Remark:
1) Synchronize time according to time zone
2) Multi-mode can be selected for time synchronization. If one works, the others take no affect.
Time setup-DST
Enable: Select to enable
Offset: After enabling DST, adjust the hour manually
Mode: Setup DST according to week or date
Start: Time to start DST
End: Time to end DST
3.5.3. START UP
Startup-ON/OFF
Page 22
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
20
ON/OFF mode: 3 modes, including ignition, timer and ignition or timer.
Ignition: Input ignition delay time for shutdown delay function
Timer: When setup the start mode as Timer, please setup the start time and end time
Under this mode, MDVR’s start up or shut down time will not affect the ignition.
Remark:
If use setup as Ignition or Timer Mode, Ignition ON or Timer start time can trigger MDVR start up.
And only when Ignition off and Timer end time, MDVR will shut down.
Start-Sleep
Sleep Mode: Currently, there is only no consumption standby mode available.
Low Voltage Protection: Enabling the low voltage shutdown protection mode selected.
Low Battery Protection: Protect the vehicle battery. When consistently below the standard
value, it will countdown shutdown. As for a 12V vehicle , the default is 9V, while a 24V vehicle
is 21V.
Recovery boot voltage values: low-voltage protection, when the battery voltage is
consistently greater than the standard value, it will automatically boot. As for a 12V vehicle , the
default is 12.5V, while a 24V vehicle is 24.5V.
Low voltage will be reported or not: The low-voltage protection will be reported to the
platform after it is ticked.
3.5.4. USER SETTING
In the basic settings, click user settings, enter the following interface, user can enter setting menu.
Page 23
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
21
User name: The default ones are admin and user.
User Group: It is divided into administrator and ordinary user.
Supports delete user function. Select the user and click "Delete User" button. Please be noted
that the administrator can not be deleted.
Supports add user function. Click "Add User" button, then enter the following interface
Remark:
1) Only administrators can add users.
2) Users can add up to two.
3) User name cannot be empty, not the same with the existed user name while the user password can
be empty.
User name and password can be modified. Select a user, click the "Edit User" button, enter the
following interface:
Page 24
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
22
Modify the user name and password to confirm the operation temporarily. There is no need to verify the
old password, Administrator user name can no t be modified.
3.5.5. NETWORK SETTINGS
In the basic settings, click Network Settings, enter the following interface, user can set network
parameters.
Network Settings - wired network and port interface description
Automatically obtain IP: Dynamic acquisition, DNS can also be statically configured to
dynamically obtain.
Use the following IP: Static IP, need to use a static DNS.
Remark:
Switch from static IP to automatically obtain IP mode, it can display dynamic IP, but the static IP
parameters will not be covered, to restore the last saved static IP after switching back.
Network Settings - Port Interface Description:
Page 25
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
23
WEB port No.: The default is 80, will be used in IE to access this port.
Media Port No.: The default is 81, the forwarding server will use this port.
Net working settings- Instruction of wifi network
Enable : Select to enable WIFI
ESSIDManually input the address of AP
Encryption: It supports NONE, WEP and WPA
Password: Manually input
Static IP: Select to use static IP, or MDVR will get dynamic IP
Network-3G/4G network interface:
Dialing wireless network, user needs to choose the module type and setup dialing parameters
No Service. When entering the dialing setup interface, it search the wireless module type
automatically. It shows No Service when ther is no module.
Page 26
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
24
Network type: The default one is Mix, 2G/3G ot 2G/3G/4G optional.
Dialing parameter:It includes access point, user name, password, data service number, and
enter SIM parameters provided by the manufacturer. The default is empty, the program comes
with empty arguments by dialing.
CertificationSupports PAP or CHAP.
Remark:
When there is SIM and normal 3G/4G signal, it will dial automatically.
Network- server
Server’s IP address and port are needed for device registering to server. Select CMS if there is
wire or WIFI. Set up central IP and port, Select 4G CMS when dialing wireless network.
By default, there is only one server, but user can add other server up to 6. Server 1 can’t be deleted.
4. VIDEO SURVEILLANCE
4.1. REAL-TIME SURVEILLANCE
Surveillance-->Real-time Surveillance
Real-time Setting Interface
Audio: Enable the audio when live view the video
Image Setting: Set the live-view parameters, including brightness, contrast, etc.
Page 27
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
25
Splash Screen: Set the live-view screen, it can be single-screen or quad screen or nine screen
Channel: Set the channel when live-view
Auto Polling Setting Interface:
Screen: Totally 32 screens can be added.
Mode: 1x1, 2x2, 3x3 optional.
Channel: Included channel number.
Residence time: Residence time for each screen.
Edit: Delete or Edit.
Add screen: Add polling screen
Auto polling: Enable the auto pulling
Sub-stream Setting Interface:
Total bandwidth: Set the bandwidth, default is 500Kbps maximum 5M
Transmit mode: Default is the recommended (smooth + clear) mode, divided into five level.
Live-view OSD Setting Interface:
Page 28
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
26
Display the information on screen, default is only the time, and the position can not be set.
4.2. RECORD
Surveillance-->Record
Record Setting Interface:
Video type: Default is PAL, NTSC optional
Overwrite: Enable the HDD to be overwritten when it is full
Lock file retention: Protect the record file to be deleted by fault, default is 7 days
Pre-recording: Pre-record before the alarm happens. Default is 15min, 0-60min optional.
Main Stream Setting Interface:
Channel: 1-20 channels can be chosen and set the record parameters
Enable: Enable the main stream record function
Resolution: The analog channel supports D1/HD1/CIF/WD1/WHD1/WCIF while the digital one
Page 29
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
27
supports 720P
Frame Rate: Frame Rate of the record
Picture Quality: Picture Quality of the record
Record Type: Ignition, Time, Event optional. Each channel can be set separately. The
sub-stream and mirror record are the same
Audio: Enable the audio. Note: Audio can not be record separately
I frame only without alarm: Enable to let the frame rate invalid, record file is I frame only
Record- Dual stream
Storage: The storage type for second stream, internal SD, or external SD
Record mode:Mirror record, alarm back-up, and sub stream
Mirror record: Channel is selectable. Video resolution and frame rate are the same with main
stream.
Alarm backup: Channel is selectable. The parameters are the same with main stream
Sub-stream: Channel is selectable. Recording parameters are configurable
Mirror channel: It is selectable according record mode
Dual stream-Sub-stream
Parameters includes channel number, enable or not, audio, resolution, frame rate and image quality
Can’t record I frame only, record parameters is completely separated from main stream.
Remark:
Main stream +sub-stream total resource can’t over 12M
Page 30
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
28
Record-OSD
Embedded key information to video file for easily check when playback.
4.3. IPC SETUP
IPC setup:
Channel: 1-16 are default for analog cameras. If selected, then analog camera is invalid. 17-20
channel are for IP cameras
Enable IPC: Enable to operate
IP and port: Display channel number and port
Setup: Search and edit IP camera recording parameters
Fast setup: Search all the IP cameras in LAN network, and auto assign IP address to IP
camera
Page 31
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
29
4.4. DATA COLLECTION
GENERAL
General- IO sensor
Sensor number: 1~8 optional.
Sensor name: IO sensor name.
OSD name: The information embedded to video image.
Copy: Copy the configuration and use it for other sensors.
General- Serial port:
General- speed
Page 32
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
30
Unit: KM/H and MPH selectable.
Source: GPS, pulse or both optional.
Calibration mode: No need to calibrate if setup as satellite mode.
4.5. ALARM
GENERAL
General --Speed alarm
Name: The current name is Overspeed
EnableEnable or disable, tick to enable
Alarm type: 3 levels
Trigger: Low or high voltage to trigger alarm
Linkage: When alarm triggered, link to alarm output, full screen live video, report to server and
so on
General- Panic alarm :
Page 33
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
31
NameThe current name is panic.
EnableEnable or disable
Alarm type: 3 levels
Trigger: Low or high voltage to trigger alarm.
Linkage: When alarm is triggered, link to alarm output, full screen live video, report to server
and so on
General – IO alarm interface:
Name: From Sensor1 to Sensor8
Enable: Enable this sensor or not, tick to enable
Alarm type: 3 levels
Trigger: Low or high voltage trigger alarm
Linkage: Link to sensor out, report alarm or full screen
IO sensor- Alarm linkage interface
Page 34
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
32
CHAssociate recording, optional
Post-recordingWhen the alarm is canceled, the time continue to record
LockOnly for alarm video
3G Network: It means when the alarm triggered, should it active the 3G module to dial or not.
Linkage output: When alarm triggered, associate with which sensor output
Output timeIt means when the alarm canceled, how long the sensor output can stand
Upload CMSUpload the alarm info to center server or not
Full screenWhen the alarm triggered, associate with a single channel to full screen or not
Alarm duration time: When alarm canceled, the alarm duration time, during this time, if this
alarm trigger again, It won’t be record again
4.6. MAINTENANCE
After login, click setup>Maintenance, and then enter into the page as follow.
4.6.1. CONFIGURATION
In the configuration page, user can export and import the configuration file.
Insert the USB drive, and then click “EXPORT”, it will export the configuration file to the root folder of
UDB driver, the file name is MDVFCFG.CFG
Import all the parameters
Insert the USB drive that with configuration file into MDVR, and login this page and click the
Page 35
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
33
“IMPORT” to import the parameters, and it will display the notice when import success.
Remark: it won’t import the register info and speed adaption info.
4.6.2. DATA EXPORT
In the Data export page, you can export the appointed file in any time, such as black box data, log
file and so on.
4.6.3. UPGRADE
In the page of upgrade, you can upgrade the firmware, MCU for MDVR
Remark:
1) Make sure don’t power off during upgrading.
2) Put the upgrade file into the folder “upgrade”, which is at the root directory if the USB drive
3) It support upgrade firmware, LOGO, MCU, and MCU for CP4.
4) Firmware and MCU will package in one file, and it will upgrade MCU first, and then firmware.
5) The name of the LOGO are: logo_update(10.12.15).jpg and logo_cvbs(11.12.15).jpg
6) Please don’t put many files in the same folder when it is upgrading, otherwise, it will
upgrade one randomly.
Page 36
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
34
4.6.4. STORAGE
In this page, user can format all the storage.
Storage type:
HDD, SD card (Internal), SD card(External), USB drive
Free/Total
Not exist: Didn’t find the HDD (not install or broken)
Unformatted: Means the HDD has been detected, but unformatted.(New HDD)
Capacity info: Display the correct info means HDD working fine
Format:
Click the Format button to start format, if format successful, it will start to recording, and don’t need to
restart, the format time will be around 10 seconds.
Remark: The new HDD and SD card must be format manually at the first time.
4.6.5. DEFAULT
In this page, you can click the default button to reset the parameters to factory settings.
Page 37
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
35
Remark:
For, language, MAC address, register info, CMS server info, speed adaption parameter will not
change during default settings.
5. REFERENCE APPENDIX
5.1. STORAGE CAPACITY CALCULATION
1) Image Quality & Streams
2) Record File Size Calculation
Rec. file size for each channel is:
Recording time (s) x Stream (Kbps) / 8 / 1024 = File Size (MB)
e.g. The file size of the Image 1 with D1 resolution within 1 hour:
3600 x 2048 Kbps / 8 / 1024 = 900 MB
3) Image Quality & Resolution
Image
1234567
8
Stream
(Kbps)
D1
2048
1536
1230
1024
900
800
720
640
HD1
1280
960
768
640
560
500
450
400
CIF
800
600
480
400
350
312
280
250
Page 38
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
36
5.2. FREQUENTLY ASKED QUESTIONS
1) The system can’t start?
Usually this problem results from the incorrect power connection. Please follow below steps to
check the power connection:
1. Check the input power, whether the power wire is connected correctly, whether the ground wire is
connected back to the battery, and whether the fuse on the power wire is in good condition.
2. Check whether the ACC signal wire input to the power is with voltage higher than 7 V.
3. Check whether the device key is closed.
2) The MDVR restarts uninterruptedly?
Please follow below steps to check it:
1. Check whether the voltage of MDVR is insufficient. If the voltage is less than the start-up voltage of
the device, the device would always restart.
2. The problem in hard disk/SD card may cause the failure to start. Take off the storage part and check
whether it is broken down.
3) The device can’t record?
Usually this problem results from the storage disk or camera. Please follow below steps to check it:
1. Check whether the storage disk is installed, whether it is in good contact, and whether the disk can
be read normally in computer.
2. Check whether the storage disk is formatted. The storage disk should be formatted before normally
storing record files.
3. Check whether there is video signal input into the device from camera, and whether there is
video/image on the screen.
4) There is no voice in record file?
Please follow below steps to check it:
1. Check whether there is an external pickup, or whether the camera features with the function of
audio collection.
2. Access to Video Channel Settings, check if Audio is set on.
3. There must be video input into the channel for recording and it must record normally.
5) The GPS works abnormally?
Please follow below steps to check it:
1. Check whether the GPS antenna is installed correctly. There is a silk print logo on the GPS antenna
holder behind the host device.
2. Check whether the antenna receiver is sheltered. It should not be covered by any stuff, which may
cause it not to receive signals.
Image
Quality
1234567
8
Reso
lution
D1
900
675
540
450
395
351
316
281
HD1
562
422
337
281
246
219
198
176
CIF
351
264
211
176
153
137
123
110
Page 39
User Manual for X5-E0804/E0408
For more information, please visit our website www.en.streamaxtech.com
37
3. Environmental influence such as tree shades, being inside tunnel, driving near tall building or
elevated roads, thunderstorms or other weather influence, etc. can also cause signal loss or
receiving wrong signals.
6) The device can’t shutdown in ignition switch mode?
Please follow below steps to check it:
1. Check if the ACC line connection mode is correct; and check whether there is voltage on ACC
yellow line when the key is turned off.
2. If the device has been set with schedule recording, it can’t shutdown if it is still during recording time
of the task table.