Streamax X5-E0804, X5-E0408, M1-H0401 User Manual

Page 1
User Manual for X5-E0804/E0408 V2.0
1 -44
User Manual
For
X5-E0804/E0408 MDVR V2.0
Mobile Digital Video Recorder
Copyright2013-2015, Streamax Technology Co., Ltd.
All Rights Reserved
For more information, please visit our website www.en.streamax.com
Page 2
User Manual for X5-E0804/E0408 V2.0
2 -44
Notice
The information in this manual was current when published. The manufacturer reserves the right to
revise and improve its products. All specifications are therefore subject to change without any notice.
The purpose of this manual is to kindly aid the user for the operation for our MDVR. The user should
have a basic understanding of computer operation and basic knowledge of how to connect peripherals
and make some settings.
Copyright
Under copyright laws, the content of this manual may not be copied, photocopied, reproduced,
translated or reduced to any electronic medium or machine- readable form, in whole or in part, without
prior written consent of Streamax Technology Co., Ltd. (Copyright 2013-2015)
For more information, please visit our website www.en.streamax.com
Page 3
User Manual for X5-E0804/E0408 V2.0
3 - 44
1) Electrical Apparatus Safety
2) Transportation
3) Installation
4) Requirements on Engineers & Technicians
5) Requirements on Environment
6) Accessories
Item
Quantity
Description
MDVR1X5-E0804 V 2.0
Remote controller
1
To control MDVR
GPS active antenna
1
L=5m
WIFI antenna
1
WCDMA 3G antenna
1
DB44 wire-S28-8CH-A
1
Key
1
To lock/unlock MDVR
Screw
6
Yo install the shelves
Shelves
2
L150*W60*T2.0mm, black
9 pin aviation power input wire
1
L=280mm
Fuse
2
Please select the right fuse.
12V power input vehicle Blue (15A) x 1
24V power input vehicle Brown (7.5A) x 1
USB wire1L=800mm
7 pin aviation amplifier output wire
1
L=250mm
Inspection certificate
1
Warranty card
1
Guarantee & Warnings
All installation and operation should comply with local electrical safety norms.
In the process of transportation, storage and installation, please avoid heavy stress, violent vibration,
impact and water splashing.
Install the equipment in accordance with the requirements, handle carefully. Do not heavily press the
equipment before the MDVR installation is finished.
All the work of checking and maintenance should be done by qualified technicians and engineers.
We do not undertake any responsibility caused by unauthorized modifications.
The equipment should be installed and stored in a cool and dry place, away from direct sunlight,
flammable or explosive substances, etc. Keep gaps not less than 3cm around the device to facilitate
ventilation for cooling.
Make sure to use accessories from the manufacturer recommended in the attachment.
Insulate circuit ground and metal shell for all the peripherals.
Before installation, please open the package and ensure that all parts are included.
If there are any problems, please contact us as soon as possible.
Package (For standard equipment)
For more information, please visit our website www.en.streamax.com
Page 4
User Manual for X5-E0804/E0408 V2.0
4 - 44
Contents
1. PRODUCT CHARACTERISTICS......................................................................................................................5
1.1. OVERVIEW.........................................................................................................................................5
1.2. FEATURES.........................................................................................................................................5
1.3. FUNCTIONS.......................................................................................................................................5
1.4. SPECIFICATIONS............................................................................................................................. 6
1.5. SYSTEM DIAGRAM..........................................................................................................................7
1.6. EXTERNAL INTERFACE................................................................................................................. 8
1.7. DESCRIPTION.................................................................................................................................11
2. SETTING............................................................................................................................................................15
2.1. CP4 CONTROL PANEL..................................................................................................................15
3. OPERATING INSTRUCTIONS........................................................................................................................16
3.1. LOCAL LOGIN..................................................................................................................................16
3.2. RECORD SEARCH AND EXPORT:............................................................................................. 17
3.3. LOG SEARCH AND EXPORT.......................................................................................................20
3.4. SYSTEM STATUS........................................................................................................................... 21
3.5. BASIC SETUP..................................................................................................................................23
3.5.1. REGISTER INFOMATION (SETUP VEHICLE INFORMATION).....................................23
3.5.2. TIME SETUP............................................................................................................................24
3.5.3. START UP.................................................................................................................................25
3.5.4. USER SETTING...................................................................................................................... 26
3.5.5. NETWORK SETTINGS.......................................................................................................... 28
4. VIDEO SURVEILLANCE.................................................................................................................................30
4.1. REAL-TIME SURVEILLANCE.......................................................................................................30
4.2. RECORD...........................................................................................................................................32
4.3. IPC SETUP....................................................................................................................................... 34
4.4. DATA COLLECTION........................................................................................................................35
4.5. ALARM.............................................................................................................................................. 36
4.6. MAINTENANCE...............................................................................................................................38
4.6.1. CONFIGURATION...................................................................................................................38
4.6.2. DATA EXPORT.........................................................................................................................39
4.6.3. UPGRADE................................................................................................................................ 39
4.6.4. STORAGE.................................................................................................................................40
4.6.5. DEFAULT.................................................................................................................................. 40
5. REFERENCE APPENDIX.................................................................................................................................42
5.1. STORAGE CAPACITY CALCULATION.......................................................................................42
5.2. FREQUENTLY ASKED QUESTIONS.......................................................................................... 42
For more information, please visit our website www.en.streamax.com
Page 5
User Manual for X5-E0804/E0408 V2.0
5 - 44
1. PRODUCT CHARACTERISTICS
1.1. OVERVIEW
1.2. FEATURES
1) All the modules are connected with exquisite connectors, supporting quick disconnection,
2) The machine will alarm automatically when each modules have faults the modules are in
3) Waterproof With sealed waterproof design for the shield.
4) Combines physical, electrical and software anti-vibration
5) Supports DC6~36V wide voltage input; suitable for 12V and 24V vehicle.
6) Adapts dynamic coding technology to adjust the change of 3G network and ensure the fluency
7) Watermark technology: prevent data tampering and guarantee the video authenticity and legal
1.3. FUNCTIONS
1) Local recording and video playback: D1/HD1/CIF resolution optional.
2) Driving recording: provide statistics on speed, turning, brake, reverse, opening door, etc.
3) Network function: support break point uploading continually, which can realize the remote
4) High-speed backup: support high-speed backup through USB2.0, as well as backup through
5) User log: on-off status of the device, video loss, recording start time / end time, user log in / log
6) Import and export of the configuration file: U disk import/export device parameters.
7) Device upgrade: support local and remote upgrade.
8) Alarm linkage: support linkage switch value output, image display, etc.
9) Storage formatting: formatting device hard disk and external USB devices.
X5-E0804/E0408 V2.0 is an advanced and function-extensive Mobile Video Recorder specially
designed for network high definition, analog audio & video input and excellent extension. It uses
high-speed processor and embedded operating system, combining with H. 264 video compression /
decompression technology, network technology and GPS locating technology. It can realize 720P high
definition, CIF, HD1, D1, WD1 video recording and vehicle driving information recording, as well as
wireless data upload. With center software it also achieves alarm linkage central monitoring, remote
management and playback analysis. It is powerful with modular design, flexible installation, easy
maintenance and high reliability.
which is safe and easy to maintain.
errors.
of monitoring video.
efficiency.
video surveillance, video download, remote alarming and network timing of the equipment,
network setting and remote upgrade, etc.
SD card.
out, modification of the device parameters, timing, bus stop announcement and GPS status.
For more information, please visit our website www.en.streamax.com
Page 6
User Manual for X5-E0804/E0408 V2.0
6 - 44
1.4. SPECIFICATIONS
Function Overview
Preview, Recording, Playback, Network, Locating
System
OS
Linux 3.0.8
Control Mode
CP4, Easy Check, IR Remote Control, Network,Mouse
Video
Input
8channel WD1+4channel IPC(720P) or
4channel WD1+8channel IPC (720P)
Output
2 channels
Total Resource
(8 x 25)FPS WD1 @ PAL / (8 x 30)FPS WD1 @ NTSC +(4 x
30)FPS 720P or
(4 x 25)FPS WD1 @ PAL / (4 x 30)FPS WD1 @ NTSC +(8 x
30)FPS 720P
Video Signal Standard
Electrical level: 1Vpp Impedance: 75Ω NTSC/PAL Optional
Audio
Input
8channels(12 channels if connects with IPCX4)
Output
2channels
Audio Signal Standard
Electrical level: 2Vpp Input impedance: 4.7kΩ
Display
Display Split
1/4/9 Image display
OSD
GPS information, alarm, temperature, acceleration, voltage,
device information, software version, MCU version, network
status
Operation Interface
Semi-transparent GUI
Recording
Video/Audio
Compression
H.264/ADPCM
Image Resolution
Analog:
PAL:WD1(928X576), WHD1(928X288), WCIF(464X288),
D1(704X576), HD1(704x288), CIF(352x288);
NTSC:WD1(928X480), WHD1(928X240), WCIF(464X240),
D1(704x480), HD1(704x240), CIF(352x240);
Digital:
720P(1280X720);
Image Quality
8 Levels adjustable
Recording Mode
Manual/schedule/Alarm(sensor trigger,
speed, acceleration, video loss, temperature)
Pre-recording
0-60minutes
Post-recording
0-30 minutes
Mirror Recording
Yes
Playback
Playback Channel
1/4 channels by local playback
Search Mode
Date/time, channel, event
Network
3G/4G
EVDO/WCDMA/TDD-LTE/FDD-LTE
Locating
GPS
Location tracking, speed detection and time sync
Storage
Hard disk
Supports 2.5" hard disk up to2TB
Interface
USB
USB2.0 x 2
SD
SD x 1
For more information, please visit our website www.en.streamax.com
Page 7
User Manual for X5-E0804/E0408 V2.0
7 - 44
RS232
RS232 X 2
RS485
RS485 X 2
Sensor
8 inputs, 2 outputs
Serial
G-sensor (Internal)
Speed
1 channel pulse speed detection
Interface
Interface (CP4) Optional
Power
Input
DC8-36V
Output
1A@12V,1A@5V
Physical
Characteristics
Dimension(L x W x H)
292.5x215x91.6mm (including shelf and back cover)
Weight
2.6 kg
Others
Water Proof Rate
IP54
1.5. SYSTEM DIAGRAM
To connect A
For more information, please visit our website www.en.streamax.com
Page 8
User Manual for X5-E0804/E0408 V2.0
8 - 44
1.6. EXTERNAL INTERFACE
1) Dimension (Unit: mm)
2) Front Panel and Rear Panel
For more information, please visit our website www.en.streamax.com
Page 9
User Manual for X5-E0804/E0408 V2.0
9 - 44
Interface
Name
Description
Hard disk box
SIM slot & SD card slot
SD card for mirror recording
Audio/Video output
To connect monitor
Lock
Hard disk lock
IR receiver
Works with remote controller
LED indicators
To show the status of different functions
USB host
For update/export file, or to connect mouse
Interface
Description
HDD
Hard disk drive indicator lamp: It is blue when there is hard disk, otherwise, it is light
off.It flashes when hard disk is reading/writing.
SD
SD card indicator lamp: green
GPS
GPS Status indicator lamp: It is green when there is module, otherwise, it is light off. It
flashes when there is position information.
NET
Network indicator lamp :It is green when there is 3G/4G module,otherwise, it is light
off. It flashes when there is network.
HTR
Heater indicator lamp: It is yellow when it is heating or keeping warm.
PWR
Power indicator lamp: blue
REC
Record indicator lamp: It is green when HDD or SD card is recording while it is light off
when it is not recording.
VLOSS
Video loss indicator lamp: It is red when there is video loss, otherwise, it is light off.
ALM
Alarm indicator lamp: It is red when there is alarm, otherwise, it is light off.
ERR
Error indicator lamp: It is red when there is something wrong with hard disk.
For more information, please visit our website www.en.streamax.com
Page 10
User Manual for X5-E0804/E0408 V2.0
10 - 44
Interface
Name
Description
3G/4G antenna
3G/4G female port
GPS antenna
GPS female port
Wifi antenna
Wifi female port
Debug
Debug port for engineer
CAN port
Reserved
Audio/Video input
Power input
DC8-36V
Amplifier
To connect speaker
Panel
To connect CP4
LAN
Network interface, connect to network switch, etc.
USB
To connect fire proof box
Serial port
For more information, please visit our website www.en.streamax.com
Page 11
11 - 44
1.7. DESCRIPTION
1. 3G/4G port
3G antenna
2. GPS port
3. Wifi port
4. A/V port
User Manual for X5-E0804/E0408 V2.0
GPS antenna
WiFi antenna
DB44 wire
For more information, please visit our website www.en.streamax.com
Page 12
12 - 44
Signals:
AV IN1 (black:GND)
red:+12V/0.5A,white:AUDIO,no color:VIDEO
AV IN2 (black:GND)
red:+12V/0.5A,white:AUDIO,no color:VIDEO
AV IN3 (black:GND)
red:+12V/0.5A,white:AUDIO,no color:VIDEO
AV IN4 (black:GND)
red:+12V/0.5A,white:AUDIO,no color:VIDEO
AV IN5 (black:GND)
red:+12V/0.5A,white:AUDIO,no color:VIDEO
AV IN6 (black:GND)
red:+12V/0.5A,white:AUDIO,no color:VIDEO
AV IN7 (black:GND)
red:+12V/0.5A,white:AUDIO,no color:VIDEO
AV IN8 (black:GND)
red:+12V/0.5A,white:AUDIO,no color:VIDEO
AV OUT1 (black:GND)
red:+12V/0.5A,white:AUDIO,no color:VIDEO
a. From AV IN1 to AV IN8, the former one is 10mm longer than the latter one.
b. From AV IN1 to AV IN8, all of them adopt 4 PIN aviation head (RS765-4), AV OUT1 adopts aviation
c. A/V wire needs to adopt shielding cable, specification is (2*24AWA+1*26AWG+1C26S) OD4.5the
5. Power input interface
User Manual for X5-E0804/E0408 V2.0
Remarks:
For example, if AV IN1 is 110mm, then AV IN2 is 120mm
female head (RS765-4)
GND wire of shielding cable needs to connect to the cover of aviation plug
9 pin aviation power input wire
For more information, please visit our website www.en.streamax.com
Page 13
13 - 44
Signal:
a. After short circuit, PIN 1 and PIN 2 of aviation head connect with red wire
b. PIN 3 of aviation head connects with yellow wire
c. After short circuit, PIN 6 and PIN 7 of aviation head connect with black wire
6. Amplifier port
Remarks:
User Manual for X5-E0804/E0408 V2.0
7 pin aviation amplifier output wire
Signal:
For more information, please visit our website www.en.streamax.com
Page 14
User Manual for X5-E0804/E0408 V2.0
14 - 44
7. Hard disk USB port
USB wire
Signal:
For more information, please visit our website www.en.streamax.com
Page 15
User Manual for X5-E0804/E0408 V2.0
15 - 44
2. SETTING
2.1. CP4 CONTROL PANEL
Repeat
Repeat station notification
Station
Notification
Station notification bottom
0-9
Number enter key
Confirmation
Confirmation key
Back
Back from the menu
Direction
Up / Down / Left / Right selection key
Operation Instrument
Remark:
When reporting to CMS server, use serial number.
For more information, please visit our website www.en.streamax.com
Page 16
User Manual for X5-E0804/E0408 V2.0
16 - 44
3. OPERATING INSTRUCTIONS
3.1. LOCAL LOGIN
1) Press the remote control LOGIN / LOCKorSETUP, the login screen will pop up.
2) Right click the mouse, the shortcut menu will pop up, left click login picture, login screen will pop up.
3) Left click on the login button to login and right click to log out
Login Notice
1) Software is automatically assigned by user name and password, it can be divided into user and
2) Password options can not be closed, but it can be set to null; when it is empty, user do not need to
Login interface Introduction
User name
1) Select users from the drop-down box. There are admin and user as defaults.
2) Currently, it can show two users and one admin.
Password
1) User can enter the operation interface if entering the right password;
2) User must enter the right password again if entering the wrong ones;
3) Click cancel to exit the login interface;
When using Android pad, you need to select vehicle number, as when insert the wifi hot spot to USB port
of the 4120, the hot spot will get the vehicle number and change its SSID to vehicle number.
When operating the device, user needs to have permission certified.
administrator privileges.
enter the password to login
For more information, please visit our website www.en.streamax.com
Page 17
17 - 44
Language
1) Support the language switch. "language" (Lang) means the current interface adopts Chinese;
2) It will automatically switch once Selecting the language.
3) Currently, it supports Chinese and English;
4) After switching languages, it will not restore language option when user restores the factory
Settings;
Default password and permission table is as follows:
Default Password
Related User
Related Authority
admin
admin
All Authorities
User
user
Search and playback
The password input Instruction
1. If the password are numbers, user can enter it by remote control directly.
2. User can click ENTERor the left click mouse on the remote control.
a. Move the cursor to the number position, press Enter or left click mouse button to select the
b. Move the cursor to 123】, press Enteror mouse to choose input type, such as
c. Move Cursor to , Press【Enter】or left click mouse to move between the contents that have
d. Move Cursor to , Press Enter】or left click mouse to delete the previous input contents.
e. Move Cursor to , Press Enteror the left click mouse to exit the keypad, the entered f. Move Cursor to【Esc】 position, Press【Enter】or the left click mouse to exit the keypad, the entered
3.2. RECORD SEARCH AND EXPORT:
User Manual for X5-E0804/E0408 V2.0
corresponding number.
the Numbers, letters, or special characters. abmeans lower case letters,【123】means numbers,【ABmeans capital letters; the highlighted
place of background refers to the current cursor position.
entered.
contents will be written to the edit box.
contents will not be written to the edit box
For more information, please visit our website www.en.streamax.com
Page 18
User Manual for X5-E0804/E0408 V2.0
18 - 44
a. No color means no video.
b. Green means common video.
c. Red means alarm video.
d. Yellow means there are alarms and the video files are automatically lock (lock video).
Record search detail interface
Record Type: User can choose all record, alarm record or normal record.
Channel chooseThe channel is optional and mark with color that has record. The channel
Click search button in the record search detail page, user can enter then record search result page.
Time Bar: Time bar shows three time points, 0 o'clock, 12 o'clock, 24 o'clock. It shows what
Channel No: According to the situation of video for each channel video the day , the video will
Video search interface contains video file search, video data backup and video playback function.
When there is a hard disk or SD card, enter the video search interface. Following is the REC Search
interface:
In the calendar, the color below the dates means:
Source: select the source of the video, there are main video, sub video and mirror video.
The main record means HDD record while sub record and mirror record are dual-stream records.
Select the date with record, click next, then enter the following interface:
Following is the record search detail and record search result interface:
with gray cannot be chosen if there is no record. As to different record type, it will show different
relates.
type of videos during the time according to the marked channel.
be displayed on the time line. Tick the channel if user wants to playback the video.
For more information, please visit our website www.en.streamax.com
Page 19
User Manual for X5-E0804/E0408 V2.0
19 - 44
Button description
Video playback: Choose the channel No., select start time to play < default start from 0 >, click
Time period settings: Click the time setting button, select start time and end time, it will backup or
Video export: Select the channel that has the video files, click this button, all the video files in
Note: channel number is displayed from 1~20, please up page up/page down button to
change channel
the playback button to playback the video.
In playback interface, user can choose fast forward or fast backward to play the video, the button in the
middle of screen can switch the channels. The image stops and it will not exit automatically when
playing to the last video of the day.
playback the video in the selected time period. Click clip to export the video, the file format can
be.264< comprehensive file >, also can be.avi format.
the effective time period will be exported to the external USB peripherals, file format can
be.264<comprehensive file >, also can be avi format.
For more information, please visit our website www.en.streamax.com
Page 20
User Manual for X5-E0804/E0408 V2.0
20 - 44
3.3. LOG SEARCH AND EXPORT
Log Search interface instruction:
Calendar: the date with log will be marked on the calendar with green color.
Log search interface instruction:
Start time: the start time for searching log files
End time: the end time for searching log files
User can also pull out the hard drive or SD card, export and playback the video by professional software.
In the log search interface, it records and displays all alarm events and login operation log. Enter the
"log query”, the interface will be shown as following :
Remark: There is no color classification in the “log mark”, and all are green ones.
For more information, please visit our website www.en.streamax.com
Page 21
User Manual for X5-E0804/E0408 V2.0
21 - 44
Log types: classification of log search, including the operation log and alarm log and locking log
Operation log search interface instruction
Log includes the following information:
Log time: the time when event is triggered
Log name: event content
Supports page up/page down and export all log files of the specified date.
Do not support link to video file.
Log search
Alarm type: It includes all alarms, IO alarm , panic alarm and over speed alarm.
Log includes the following information:
Log time :the time when event is triggered
Log nameevent content
Supports page up/page down and export all log files of the specified date.
Supports link to video file, click on button to playback video files
Lock log search
Log includes the following information:
Log time: the time of when event triggered.
Log name: event content
Support page up and page down.
Can’t export all log files of the specified date.
Can link to video file, click on button to playback video files. Unlock: Select log, and unlock it. Then the alarm log of lock will be cleared.
3.4. SYSTEM STATUS
Log will be recorded according to channel number, each channel will have a lock log file.
Remark:
When lock the video file, system will record alarm log and lock log. The locked video file can only be
unlocked from alarm log.
User can login the interface with no access restrictions.
For more information, please visit our website www.en.streamax.com
Page 22
User Manual for X5-E0804/E0408 V2.0
22 - 44
System- Version information
System- Modules
System-Server status
System - Environment
For more information, please visit our website www.en.streamax.com
Page 23
User Manual for X5-E0804/E0408 V2.0
23 - 44
System-Storage:
3.5. BASIC SETUP
3.5.1. REGISTER INFOMATION (SETUP VEHICLE INFORMATION)
Register information-Device info:
Device ID: Currently, it is not useful.
Register information- Vehicle info
Click setup button and enter the following interfaces:
For more information, please visit our website www.en.streamax.com
Page 24
User Manual for X5-E0804/E0408 V2.0
24 - 44
Vehicle NumberWhen connected with PAD, the vehicle number is needed.
Vehicle plateInput manually.
Line numberInput manually.
Register information—About the driver’s information:
Driver number: Input manually.
Driver name: Input manually.
3.5.2. TIME SETUP
Time setup-General
For more information, please visit our website www.en.streamax.com
Page 25
25 - 44
Date format: Setup the date format of device
Time format: 24 hours or 12 hours
Time zone: Range from -12thdistrict ~ +13thdistrict
Time-Time Sync
Date/Time: Device time, from 2000-01-01 to 2037-12-31
Satellite: Synchronize time with GPS satellite. Once GPS signal changes to valid, device will
synchronize time
Center Server: synchronize time with center server
NTP server: synchronize time with NTP server
1) Synchronize time according to time zone
2) Multi-mode can be selected for time synchronization. If one works, the others take no affect.
Time setup-DST
Enable: Select to enable
Offset: After enabling DST, adjust the hour manually
Mode: Setup DST according to week or date
Start: Time to start DST
End: Time to end DST
3.5.3. START UP
Startup-ON/OFF
User Manual for X5-E0804/E0408 V2.0
Remark:
ON/OFF mode: 3 modes, including ignition, timer and ignition or timer.
For more information, please visit our website www.en.streamax.com
Page 26
User Manual for X5-E0804/E0408 V2.0
26 - 44
Start-Sleep
Sleep Mode: Currently, there is only no consumption standby mode available.
Low Voltage Protection: Enabling the low voltage shutdown protection mode selected.
Low Battery Protection: Protect the vehicle battery. When consistently below the standard
Recovery boot voltage values: low-voltage protection, when the battery voltage is
Low voltage will be reported or not: The low-voltage protection will be reported to the
3.5.4. USER SETTING
Ignition: Input ignition delay time for shutdown delay function
Timer: When setup the start mode as Timer, please setup the start time and end time
Under this mode, MDVR’s start up or shut down time will not affect the ignition.
Remark:
If use setup as Ignition or Timer Mode, Ignition ON or Timer start time can trigger MDVR start up.
And only when Ignition off and Timer end time, MDVR will shut down.
value, it will countdown shutdown. As for a 12V vehicle , the default is 9V, while a 24V vehicle
is 21V.
consistently greater than the standard value, it will automatically boot. As for a 12V vehicle , the
default is 12.5V, while a 24V vehicle is 24.5V.
platform after it is ticked.
In the basic settings, click user settings, enter the following interface, user can enter setting menu.
For more information, please visit our website www.en.streamax.com
Page 27
27 - 44
User name: The default ones are admin and user.
User Group: It is divided into administrator and ordinary user.
Supports delete user function. Select the user and click "Delete User" button. Please be noted
that the administrator can not be deleted.
Supports add user function. Click "Add User" button, then enter the following interface
1) Only administrators can add users.
2) Users can add up to two.
3) User name cannot be empty, not the same with the existed user name while the user password can
User name and password can be modified. Select a user, click the "Edit User" button, enter the
User Manual for X5-E0804/E0408 V2.0
Remark:
be empty.
following interface:
For more information, please visit our website www.en.streamax.com
Page 28
User Manual for X5-E0804/E0408 V2.0
28 - 44
3.5.5. NETWORK SETTINGS
Network Settings - wired network and port interface description
Automatically obtain IP: Dynamic acquisition, DNS can also be statically configured to
Use the following IP: Static IP, need to use a static DNS.
Network Settings - Port Interface Description:
Modify the user name and password to confirm the operation temporarily. There is no need to verify the
old password, Administrator user name can no t be modified.
In the basic settings, click Network Settings, enter the following interface, user can set network
parameters.
dynamically obtain.
Remark:
Switch from static IP to automatically obtain IP mode, it can display dynamic IP, but the static IP
parameters will not be covered, to restore the last saved static IP after switching back.
For more information, please visit our website www.en.streamax.com
Page 29
User Manual for X5-E0804/E0408 V2.0
29 - 44
WEB port No.: The default is 80, will be used in IE to access this port.
Media Port No.: The default is 81, the forwarding server will use this port.
Net working settings- Instruction of wifi network
Enable : Select to enable WIFI
ESSIDManually input the address of AP
Encryption: It supports NONE, WEP and WPA
Password: Manually input
Static IP: Select to use static IP, or MDVR will get dynamic IP
Network-3G/4G network interface: No Service. When entering the dialing setup interface, it search the wireless module type
Dialing wireless network, user needs to choose the module type and setup dialing parameters
automatically. It shows No Service when ther is no module.
For more information, please visit our website www.en.streamax.com
Page 30
User Manual for X5-E0804/E0408 V2.0
30 - 44
Network type: The default one is Mix, 2G/3G ot 2G/3G/4G optional.
Dialing parameterIt includes access point, user name, password, data service number, and
CertificationSupports PAP or CHAP.
Network- server
4. VIDEO SURVEILLANCE
4.1. REAL-TIME SURVEILLANCE
Real-time Setting Interface
Audio: Enable the audio when live view the video
Image Setting: Set the live-view parameters, including brightness, contrast, etc.
enter SIM parameters provided by the manufacturer. The default is empty, the program comes
with empty arguments by dialing.
Remark:
When there is SIM and normal 3G/4G signal, it will dial automatically.
Server’s IP address and port are needed for device registering to server. Select CMS if there is
wire or WIFI. Set up central IP and port, Select 4G CMS when dialing wireless network.
By default, there is only one server, but user can add other server up to 6. Server 1 can’t be deleted.
Surveillance-->Real-time Surveillance
For more information, please visit our website www.en.streamax.com
Page 31
User Manual for X5-E0804/E0408 V2.0
31 - 44
Splash Screen: Set the live-view screen, it can be single-screen or quad screen or nine screen
Channel: Set the channel when live-view
Auto Polling Setting Interface:
Screen: Totally 32 screens can be added.
Mode: 1x1, 2x2, 3x3 optional.
Channel: Included channel number.
Residence time: Residence time for each screen.
Edit: Delete or Edit.
Add screen: Add polling screen
Auto polling: Enable the auto pulling
Sub-stream Setting Interface:
Total bandwidth: Set the bandwidth, default is 500Kbps maximum 5M
Transmit mode: Default is the recommended (smooth + clear) mode, divided into five level.
Live-view OSD Setting Interface:
For more information, please visit our website www.en.streamax.com
Page 32
User Manual for X5-E0804/E0408 V2.0
32 - 44
4.2. RECORD
Record Setting Interface:
Video type: Default is PAL, NTSC optional
Overwrite: Enable the HDD to be overwritten when it is full
Lock file retention: Protect the record file to be deleted by fault, default is 7 days
Pre-recording: Pre-record before the alarm happens. Default is 15min, 0-60min optional.
Main Stream Setting Interface:
Channel: 1-20 channels can be chosen and set the record parameters
Enable: Enable the main stream record function
Resolution: The analog channel supports D1/HD1/CIF/WD1/WHD1/WCIF while the digital one
Display the information on screen, default is only the time, and the position can not be set.
Surveillance-->Record
For more information, please visit our website www.en.streamax.com
Page 33
33 - 44
supports 720P
Frame Rate: Frame Rate of the record
Picture Quality: Picture Quality of the record
Record Type: Ignition, Time, Event optional. Each channel can be set separately. The
Audio: Enable the audio. Note: Audio can not be record separately
I frame only without alarm: Enable to let the frame rate invalid, record file is I frame only
Record- Dual stream
Storage: The storage type for second stream, internal SD, or external SD
Record mode:Mirror record, alarm back-up, and sub stream
Mirror channel: It is selectable according record mode
Dual stream-Sub-stream
sub-stream and mirror record are the same
User Manual for X5-E0804/E0408 V2.0
Mirror record: Channel is selectable. Video resolution and frame rate are the same with main
stream.
Alarm backup: Channel is selectable. The parameters are the same with main stream
Sub-stream: Channel is selectable. Recording parameters are configurable
Parameters includes channel number, enable or not, audio, resolution, frame rate and image quality
Can’t record I frame only, record parameters is completely separated from main stream.
Remark:
Main stream +sub-stream total resource can’t over 12M
For more information, please visit our website www.en.streamax.com
Page 34
User Manual for X5-E0804/E0408 V2.0
34 - 44
Record-OSD
4.3. IPC SETUP
IPC setup:
Channel: 1-16 are default for analog cameras. If selected, then analog camera is invalid. 17-20
Enable IPC: Enable to operate
IP and port: Display channel number and port
Setup: Search and edit IP camera recording parameters
Fast setup: Search all the IP cameras in LAN network, and auto assign IP address to IP
Embedded key information to video file for easily check when playback.
channel are for IP cameras
camera
For more information, please visit our website www.en.streamax.com
Page 35
35 - 44
4.4. DATA COLLECTION
GENERAL
General- IO sensor
Sensor number: 1~8 optional.
Sensor name: IO sensor name.
OSD name: The information embedded to video image.
Copy: Copy the configuration and use it for other sensors.
General- Serial port:
General- speed
User Manual for X5-E0804/E0408 V2.0
For more information, please visit our website www.en.streamax.com
Page 36
User Manual for X5-E0804/E0408 V2.0
36 - 44
Unit: KM/H and MPH selectable.
Source: GPS, pulse or both optional.
Calibration mode: No need to calibrate if setup as satellite mode.
4.5. ALARM
General --Speed alarm
Name: The current name is Overspeed
EnableEnable or disable, tick to enable
Alarm type: 3 levels
Trigger: Low or high voltage to trigger alarm
Linkage: When alarm triggered, link to alarm output, full screen live video, report to server and
General- Panic alarm :
GENERAL
so on
For more information, please visit our website www.en.streamax.com
Page 37
37 - 44
NameThe current name is panic.
EnableEnable or disable
Alarm type: 3 levels
Trigger: Low or high voltage to trigger alarm.
Linkage: When alarm is triggered, link to alarm output, full screen live video, report to server
and so on
General – IO alarm interface:
Name: From Sensor1 to Sensor8
Enable: Enable this sensor or not, tick to enable
Alarm type: 3 levels
Trigger: Low or high voltage trigger alarm
Linkage: Link to sensor out, report alarm or full screen
IO sensor- Alarm linkage interface
User Manual for X5-E0804/E0408 V2.0
For more information, please visit our website www.en.streamax.com
Page 38
User Manual for X5-E0804/E0408 V2.0
38 - 44
CHAssociate recording, optional
Post-recordingWhen the alarm is canceled, the time continue to record
LockOnly for alarm video
3G Network: It means when the alarm triggered, should it active the 3G module to dial or not.
Linkage output: When alarm triggered, associate with which sensor output
Output timeIt means when the alarm canceled, how long the sensor output can stand
Upload CMSUpload the alarm info to center server or not
Full screenWhen the alarm triggered, associate with a single channel to full screen or not
Alarm duration time: When alarm canceled, the alarm duration time, during this time, if this
4.6. MAINTENANCE
4.6.1. CONFIGURATION
Insert the USB drive, and then click “EXPORT”, it will export the configuration file to the root folder of
Insert the USB drive that with configuration file into MDVR, and login this page and click the
alarm trigger again, It won’t be record again
After login, click setup>Maintenance, and then enter into the page as follow.
In the configuration page, user can export and import the configuration file.
UDB driver, the file name is MDVFCFG.CFG
Import all the parameters
For more information, please visit our website www.en.streamax.com
Page 39
User Manual for X5-E0804/E0408 V2.0
39 - 44
Remark: it won’t import the register info and speed adaption info.
4.6.2. DATA EXPORT
4.6.3. UPGRADE
1) Make sure don’t power off during upgrading.
2) Put the upgrade file into the folder “upgrade”, which is at the root directory if the USB drive
3) It support upgrade firmware, LOGO, MCU, and MCU for CP4.
4) Firmware and MCU will package in one file, and it will upgrade MCU first, and then firmware.
5) The name of the LOGO are: logo_update(10.12.15).jpg and logo_cvbs(11.12.15).jpg
6) Please don’t put many files in the same folder when it is upgrading, otherwise, it will
“IMPORT” to import the parameters, and it will display the notice when import success.
In the Data export page, you can export the appointed file in any time, such as black box data, log
file and so on.
In the page of upgrade, you can upgrade the firmware, MCU for MDVR
Remark:
upgrade one randomly.
For more information, please visit our website www.en.streamax.com
Page 40
40 - 44
4.6.4. STORAGE
In this page, user can format all the storage.
Storage type:
Free/Total
Format:
4.6.5. DEFAULT
User Manual for X5-E0804/E0408 V2.0
HDD, SD card (Internal), SD card(External), USB drive
Not exist: Didn’t find the HDD (not install or broken)
Unformatted: Means the HDD has been detected, but unformatted.(New HDD)
Capacity info: Display the correct info means HDD working fine
Click the Format button to start format, if format successful, it will start to recording, and don’t need to
restart, the format time will be around 10 seconds.
Remark: The new HDD and SD card must be format manually at the first time.
In this page, you can click the default button to reset the parameters to factory settings.
For more information, please visit our website www.en.streamax.com
Page 41
User Manual for X5-E0804/E0408 V2.0
41 - 44
Remark:
For, language, MAC address, register info, CMS server info, speed adaption parameter will not
change during default settings.
For more information, please visit our website www.en.streamax.com
Page 42
User Manual for X5-E0804/E0408 V2.0
42 - 44
5. REFERENCE APPENDIX
5.1. STORAGE CAPACITY CALCULATION
1) Image Quality & Streams
2) Record File Size Calculation
3) Image Quality & Resolution
5.2. FREQUENTLY ASKED QUESTIONS
1) The system can’t start?
1. Check the input power, whether the power wire is connected correctly, whether the ground wire is
2. Check whether the ACC signal wire input to the power is with voltage higher than 7 V.
Image
1234567
8
Stream
(Kbps)
D1
2048
1536
1230
1024
900
800
720
640
HD1
1280
960
768
640
560
500
450
400
CIF
800
600
480
400
350
312
280
250
Image
Quality
1234567
8
Reso
lution
D1
900
675
540
450
395
351
316
281
HD1
562
422
337
281
246
219
198
176
CIF
351
264
211
176
153
137
123
110
Rec. file size for each channel is:
Recording time (s) x Stream (Kbps) / 8 / 1024 = File Size (MB)
e.g. The file size of the Image 1 with D1 resolution within 1 hour:
3600 x 2048 Kbps / 8 / 1024 = 900 MB
Usually this problem results from the incorrect power connection. Please follow below steps to
check the power connection:
connected back to the battery, and whether the fuse on the power wire is in good condition.
For more information, please visit our website www.en.streamax.com
Page 43
User Manual for X5-E0804/E0408 V2.0
43 - 44
3. Check whether the device key is closed.
2) The MDVR restarts uninterruptedly?
1. Check whether the voltage of MDVR is insufficient. If the voltage is less than the start-up voltage of
2. The problem in hard disk/SD card may cause the failure to start. Take off the storage part and check
3) The device can’t record?
1. Check whether the storage disk is installed, whether it is in good contact, and whether the disk can
2. Check whether the storage disk is formatted. The storage disk should be formatted before normally
3. Check whether there is video signal input into the device from camera, and whether there is
4) There is no voice in record file?
1. Check whether there is an external pickup, or whether the camera features with the function of
2. Access to Video Channel Settings, check if Audio is set on.
3. There must be video input into the channel for recording and it must record normally.
5) The GPS works abnormally?
1. Check whether the GPS antenna is installed correctly. There is a silk print logo on the GPS antenna
2. Check whether the antenna receiver is sheltered. It should not be covered by any stuff, which may
3. Environmental influence such as tree shades, being inside tunnel, driving near tall building or
6) The device can’t shutdown in ignition switch mode?
1. Check if the ACC line connection mode is correct; and check whether there is voltage on ACC
2. If the device has been set with schedule recording, it can’t shutdown if it is still during recording time
7) Which IP waterproof level does Streamax device support?
8) How to install the WIFI antenna?
9) The device cannot be shut down when in ignition ON/OFF mode.
Please follow below steps to check it:
the device, the device would always restart.
whether it is broken down.
Usually this problem results from the storage disk or camera. Please follow below steps to check it:
be read normally in computer.
storing record files.
video/image on the screen.
Please follow below steps to check it:
audio collection.
Please follow below steps to check it:
holder behind the host device.
cause it not to receive signals.
elevated roads, thunderstorms or other weather influence, etc. can also cause signal loss or
receiving wrong signals.
Please follow below steps to check it:
yellow line when the key is turned off.
of the task table.
Currently, X7 and X5-E0804 support waterproof IP 54.
The antenna must be installed on unobstructed place of the roof, and be fixed with glue.
Check if the ACC signal wiring is correct and if there is voltage for ACC signal line after the key is
turned off .
If you have set timing recording, and at the current time it is still in task recording, the device may be
For more information, please visit our website www.en.streamax.com
Page 44
User Manual for X5-E0804/E0408 V2.0
44 - 44
10) GPS anomaly.
11) No voice in video files.
12) The device doesn’t record.
13) Why has the MDVR device always been in a state of restart?
14) Why the MDVR device cannot start?
15) What is the login user name and password for new device?
16) How to update the firmware?
17) In the ON/OFF of basic settings, the low voltage protection is 8V, why?
impossible to be shut down.
Check if the GPS antenna is properly installed. There is silkscreen GPS identification on the GPS
antenna pedestal on the back of the MDVR device. Check if the antenna connector is blocked and
make sure the antenna connector not be covered by other things.
Trees block, being inside the tunnel, driving near tall buildings or viaduct, thunderstorms and other
environmental effects may also cause to receive no GPS signal or error signal.
See if there is an external microphone, or if the camera cannot capture audio;
Enter into the video channel settings, then check if the audio is open;
Ensure video input and normal recording, on which the audio recording channels must be based.
Make sure the storage part is installed and of fine contact, the data can be read on PC, and the
storage device is not formatted.
Check if there are video signal input to the main device, and whether there are video images in the
channel pictures.
Check whether the MDVR device voltage is insufficient. If the device voltage does not reach the
start voltage, the device will restart.
Hard disk or SD card may cause the MDVR device unable to start. You need to remove the storage
device and then boot up to verify whether it is caused by the storage device.
Check the device input power to see if the power wiring is correct, if there is ground wire connected
back to the battery, and if the fuse of the power wire is n good condition;
Check whether there is voltage(more than 7V) on power input ACC signal wire;
Check whether the hard disk key is turned off.
The default user name and password are both “admin”. The device password can be set as empty.
Change the previous file folder name “dvrupgrade” to “upgrade”. Change the file name
FWX15-0401-05-01-V01V01V01V491087 to RMMDVR_X5_III_T2014111005_convert
After testing, when the battery is lower than 8V, the voltage will lower down quickly. Therefore the
lowest voltage is set to be 8V. When it is lower than 8V, the MDVR device will recognize it as
external power-off and then enter into shutdown state.
For more information, please visit our website www.en.streamax.com