Strand Lighting 48/96 Manual/Memory, 24/48 Manual/Memory, 300 Series, Memory 250, Memory 125 Installation Manual

...
Page 1
Welcome
Warning
Thank you for buying Strand Lighting control equipment. We hope that you will find that your lighting needs are met by your new system and that you will enjoy exploring the new facilities that your new system offers. You are provided with essential information to help you install and operate your sys­tem. Please look through all the documents and keep them safely for future use. If you have any difficulties, please do not hesitate to contact Strand Lighting, or any authorised Strand service centre for advice.
This equipment is designed to operate from the mains electricity supply and contains voltages which, if touched, may cause death or injury. It should only be operated in accordance with the instructions provided and for the purpose of a lighting control system.
Avoid spilling liquid on the equipment. If this should happen, switch the equip­ment off immediately. To reduce the risk of fire or electric shock, do not expose the equipment to rain or moisture.
For indoor use only.
This equipment is designed and manufactured to comply with international safety standards IEC950, UL1950, CS950 and is intended for use as part of a lighting control system. It must not be used for other purposes where there is a risk of safety to persons. The equipment contains power voltages, socket outlets shall be installed near to the equipment and be easily accessible.
• Working Voltage/Current 100-120 (2A) 220-240 (1A)
• Frequency 50/60 Hz
• Max Ambient Temp 35
o
C
• Do not restrict ventilation
This manual describes the installation procedures for the following Strand Lighting 300 Series consoles.
• 24/48 Manual/Memory
• 48/96 Manual/Memory
• Memory 125
• Memory 250
• Memory 400
• Memory 600
• 120 Submasters
• 310 Show Controller
Document No: 40/B973 Date: March 2000
Page 1
Installation Manual - 300 Series Consoles & 310 Show Controller
Page 2
Offices and Service Centres
Phone numbers do not include country code or other international access data. World Wide Web: http://www.strandlighting.com/
Strand Lighting Asia Ltd: 7/F Corporation Square, 8 Lam Lok Street, Kowloon Bay, Hong Kong.
Tel: 852 2757 3033, Fax: 852 2757 1767 E mail: [email protected]
Strand Lighting Inc (Los Angeles): 18111 Santa Fe Avenue, Ranch
Dominguez, CA 90221, USA.
Tel: (310) 637 7500, Fax: (310) 632 5519, Fax: 800 775-LEKO, Email: [email protected]
Strand Lighting Inc (New York): 2nd Floor, 151W-25th St, New York Tel: (212) 242 1042, Fax: (212) 242 1837, Email: [email protected] US Service & Support: 800 4 STRAND (800.478.7263)
Strand Lighting (Canada) Inc (Toronto): 2430 Lucknow Drive #15,
Mississauga, Ontario, L5S 1V3, Canada
Tel: 905 677 7130 or 800-387-3403, Fax: 905 677 6859, E mail: [email protected]
Strand Lighting Limited (Kirkcaldy): Mitchelston Industrial Estate, Kirk-
caldy, Fife, KY1 3LY, Scotland,
Tel: 01592 652333, Fax: 01592 653528 Software Registration: 01592 653499, E mail: [email protected]
Strand Lighting Limited (Paris): 1 rue de l’Arc de Triomphe, Paris 17,
France
Tel: 00 331 553 70033, Fax: 00 331 553 70233, E mail: [email protected]
Strand Lighting GmbH (Berlin): Strand Lighting GMBH, Ullsteinstrasse 114-142, 12109 BERLIN, Tel: 004930 707 9510, Fax: 004930 707 95199 E mail: [email protected]
Strand Lighting Italia Srl - (Pomezia): Via delle Gardenie, 33, 00040
Pomezia – Roma, Italia,
Tel: 00 39 06 914 7123, Fax: 00 39 06 914 7138 E mail: [email protected]
Strand Lighting Limited (Moscow): Novinsky Boulevard 20A, Buildings 3-
6, 121069 Moscow, Russia,
Tel: 007 095 290 2092, Fax: 007 095 290
Installation Manual - 300 Series Consoles & 310 Show Controller
Page 2
Page 3
Unpacking
Package 1
300 Series Processor Unit, or 310 Show Controller complete with the following:
(i) Operator’s Guide, CD Rom, (ii) Password Disk (iii) Power Cable
Note: The 310 Show Controller is normally supplied as a stand-alone lighting controller. In this case, Package 2 is not included
Package 2
24/48 Manual/Memory console comprising a command module plus three fader modules.
Open the packaging and check that the following components are contained within. If any parts are missing, or damaged, please contact the carrier and your nearest Strand Lighting office.
300 series Processor Unit
or
310 Show Controller
Mounting Brackets
or 48/96 Manual/Memory console
comprising a command module plus five fader modules
Page 3
Installation Manual - 300 Series Consoles & 310 Show Controller
Page 4
Unpacking
or Memory 125 or 250 console
comprising a command module and one 24 submaster fader module
or Memory 400 or 600 console
comprising a command module and one 24 submaster fader module and two LCD monitor modules.
or 120 submaster console
comprising a command module plus five submaster fader modules.
and the following items: (i) Microsoft Intellimouse trackball
(ii) LCD cables (400 and 600
Memory Consoles only)
(iii) 3 Metre Cat 5 cable with RJ45
connectors – Control Console to
Processor
Installation Manual - 300 Series Consoles & 310 Show Controller
Page 4
Page 5
Getting Started
Mounting the processor unit (including 310 Show Controller)
Note: The equipment can be mounted to a wall with the brackets supplied. Ensure the fixings (e.g. wall screws) are suitable for the weight of the unit and are of sufficient size for the slots provided in the back plate. The unit can be regarded as wall mounted moveable equipment. The means of fastening must permit ready removal for maintenance and repair. Therefore after hanging the unit on its brackets, do not tighten the screws fully, so that the unit can be lifted from the wall.
When rack mounting, ensure that no hazardous conditions are created due to uneven mechanical loading.
Ensure that reliable earthing of the equipment is maintained at all times.
Consideration should be given to the supply circuit feeding the equipment and the effect that overloading might have on overcurrent protection and the supply wiring.
The processor unit is designed to sit on a desk, or to be mounted onto, or under a desk, or wall-mounted, or mounted within a 19 inch rack unit. Multi-purpose brackets are supplied with the unit as shown.
Fixed to Desk
Under Desk Mounting
19 in Rack Unit
Fixed to Wall
Connecting The processor to the Command Module (Optional on 310 Show Controller)
Note: All standard models are supplied
daisy-chained with a line terminator on the last module. Additional modules can be added to the daisy chain, and the line terminator moved to the last module. Alternatively, remote modules can be connected to one of the other RJ45 Sbus connectors.
Important Note: Do not fit or remove the Sbus connectors unless the con­sole has completely powered down.
Page 5
Underside of command
module
RJ45 Sbus connector on Processor unit
Cat 5 cable
Installation Manual - 300 Series Consoles & 310 Show Controller
Page 6
Getting Started (cont.)
Connecting an External Monitor (Optional on 310 Show Controller and on 400 and 600 Memory Consoles)
Connecting LCD Monitors (two supplied as standard on 400 and 600 Memory Consoles only)
Mains supply
Rear of
LCD Monitors
Rear of
Processor Unit
Connecting the Mouse (Optional on 310 Show Controller)
Note: The mouse will not operate until the mouse net node and port has been set up in the User Setup Screen. (Refer to the Introduction Section of the User Guide)
Rear of
Command Module
Rear of Processor Unit
Connection to COM1
port using adaptor
LCD
Cables
Max. 10mtrs
Connection to COM2
port using adaptor
Connection to mouse PS2 port on rear of Processor Unit
LCD1
Connector
LCD2
Connector
Connection to PS2 port
Alternative
mouse
connections
Installation Manual - 300 Series Consoles & 310 Show Controller
Page 6
Page 7
Getting Started (cont.)
Connecting an External Keyboard (Optional)
Connecting a Printer (Optional)
Rear of
Command Module
PS2 port
Rear of Processor Unit
Alternative connection to keyboard PS2 port on rear of Processor Unit
Keyboard
Rear of Processor Unit
Connecting to the Mains Supply
Page 7
100 - 120, (2A) / 220 - 240V ( 1A), 50/60Hz
Installation Manual - 300 Series Consoles & 310 Show Controller
Page 8
Getting Started (cont.)
Positioning Hinged Modules
Hinged fader module
Command module or
fader module
Support
Hinge
Hinged foot rest
Positioning and Support for Command Module and Fader Module, or Fader
Module and Fader Module
LCD monitor
bracket
Position for best viewing
Command module or
fader panel
Positioning and Support for Command Module and LCD Monitor module
Hinge
Hinged foot rest
Installation Manual - 300 Series Consoles & 310 Show Controller
Page 8
Page 9
Getting Started (Cont.)
Connecting the DMX Outputs
Power Up/Power Down Note: To shutdown, refer to the shut-
down procedure described in the User Guide. Do not shut down by removing the mains plug.
DMX 1 DMX 2
DMX Outputs to Dimmers,
etc. Refer to Operator’s
Manual.
Channel Level and State Screen
Press button or ‘P14’ key on Command Module
Channel Levels
Screen
Press button or ‘P14’ key on Command Module
Operating the Lighting Consoles Operating instructions for the GeniusPro/Lightpalette software installed in your
console are provided in the Operator’s Guide supplied with this console. A detailed operator’s manual and tutorial are also available on the CD supplied.
State Screen
Page 9
Installation Manual - 300 Series Consoles & 310 Show Controller
Page 10
Connecting Advanced Functions of the 300 Series Consoles
Connecting to an Ethernet Network (Standard on 310 Show Controller and all 300 Series Memory Consoles)
Connecting to a Macro Tablet (Including 310 Show Controller)
Connecting a SMPTE Clock (Standard on 310Show Controller. Optional on 300 Series Consoles)
Rear of Processor Unit
Ethernet connection to network (refer to Operator’s Manual/ On-Screen Help)
Macro Tablet
Rear of Processor Unit
COM1port or COM2 port on Command Module
Refer to Operator’s Guide/Manual or On-Screen Help.
Rear of Processor Unit
Connecting MIDI (Standard on 310Show Controller. Optional on 300 Series Consoles)
Refer to Operator’s Manual or On-Screen Help.
Installation Manual - 300 Series Consoles & 310 Show Controller
SMPTE clock input. Refer to Operator’s Guide/Manual or On-Screen Help.
Rear of Processor Unit
Page 10
Page 11
Connecting Advanced Functions of the 300 Series Consoles
Connecting External Submaster Macros (Standard on 310Show Controller. Optional on 300 Series Consoles)
Connecting Hand-held Remotes and Other Devices (Standard on 300 Consoles and 310 Show Controller)
Submaster 1-12 Macros
External Submaster Macro Inputs. Refer to Operator’s Manual or On-Screen Help
Each of the 24 submaster macro inputs consist of a signal/ground pair on adja­cent pins of a D type connector. The required number of contact closure devices are coupled to the connector(s) using twisted pair cables. It is recommended to use 24AWG twisted pair wires for each contact. CAT5 UTP cable is suitable.
AUX 1 AUX 2
Submaster 13 -24 Macros
Auxiliary Inputs for Hand-Held Remotes and other devices. Refer to Operator’s Manual or On-Screen Help.
Page 11
Installation Manual - 300 Series Consoles & 310 Show Controller
Page 12
Changing the Module Configuration and Adding New Modules
Changing the Module Configuration
The modular concept of the 300 Series consoles, allows the user to change the configuration of modules and to add fader modules or LCD display modules as required. Fader modules can be physically coupled to the hinge assembly, or coupled to either side of the control module and to each other to form a conventional control console. A maximum of two LCD modules can to be coupled to the hinge assembly and set at the best viewing angle. You can also position individual modules, or physically coupled modules separated by up to 100metres from the command module.
Note: For portable units, no more than six modules should be physically con­nected together, (three modules on the horizontal plane and three mounted on the hinge).
Fitting and removing a hinged module LCD modules are always fitted to the hinge on the back of a horizontal module and the command module always fitted as a horizontal module. However, fader modules may be fitted in either position to suit the operator’s preference and the layout of the control room. A hinge assembly and module coupling pins are supplied with each module, where no module is fitted to the hinge. In this way, the user can change the configuration of the fader modules. Similarly when addi­tional modules are supplied, hinge assemblies and coupling pins are included.
Important Note: Before making any changes to the console configuration, en­sure that the mains supply is switched off and the mains plug removed.
Before fitting or removing a hinge assembly, separate the horizontal units by turning the two half-turn fasteners counter-clockwise and pulling the modules apart.
Screw-in module coupling pins
Screw -in pins and hinge assembly are located in the tool box on the rear of the module, as shown.
Installation Manual - 300 Series Consoles & 310 Show Controller
Page 12
Page 13
Changing the Console Configuration and Adding New Modules
Place one hinge assembly in the position shown and tighten the allen screw us­ing the allen key provided. Place the tubed section of the module over the spigot on the top of the hinge, ensuring that the locating pin is located in the recess, as shown. Hold the module in position, while fitting the opposite hinge assembly. To remove a module from the hinge, reverse this procedure.
Rotating a Fader Panel Fascia
When a fader panel is moved from a horizontal position to a hinged position, or vice-versa, the panel fascia must be rotated such that the controls are facing the correct way.
To rotate the panel fascia, remove the Sbus connector, then remove the four panel screws, turn the panel facia, refit the screws and refit the Sbus connector.
Page 13
Installation Manual - 300 Series Consoles & 310 Show Controller
Page 14
Changing the Console Configuration and Adding New Modules
Expanding Your System
The diagram below shows a typical expanded system incorporating seven fader panels and two LCD monitors connected to one command module and one processor unit.
Anti-Theft Device
Installation Manual - 300 Series Consoles & 310 Show Controller
Holes for Kensington-type anti theft device
Page 14
Loading...