System PR Electro-Mechanical Remote Control with Two Presets
This system is available for 60, 72 or 96 individually controlled dimmer channels. Each equipment consists of a remote control
cabinet, a preformed control cable and a dimmer bank with servo-operated variable load resistance dimmers driven by individual
electro-mechanical clutches from a common variable speed motor. Neither of the two dimmer levers to each channel have to
maintain a constant control signal to the dimmer servo and therefore they are available for presetting precise intensity levels two
changes in advance of the lighting in use.
CONTROL CABINET
Cabinets are of sheet metal construction finished hammer blue and grey. All internal wiring is fitted terminating in a testboard
which is also the connection point for the preformed control cable. A floor-standing cabinet is standard but a desk version is
available for an additional charge.
Control Cabinet type PR/72
1. Three-position switch for grouping to Blackout A, or off,
or Blackout B.
2
. Moulded dimmer unit with white scale.
3
. Moulded dimmer unit with green scale.
4
. Three-position switch for grouping the white and green
dimmer levers to the X, Y or Z Move group switches.
5
. Move group switches which when down select the X, Y
and Z groups to change when a master push is pressed.
6
. RAISE push causes selected groups to raise to full
independent of all dimmer levers.
7. *DIM push causes selected groups to fade to zero
independent of all dimmer levers.
8. *WHITE PRESET push causes selected groups to change
to the levels preset on the white dimmer levers.
9. *GREEN PRESET push causes selected groups to
change to the levels preset on the green dimmer levers.
10
. REMAINDER DIM, in conjunction with RAISE or a
PRESET push, causes a cross-fade by fading groups not
selected to zero.
11
. Speed Lever determines the speed, from 3 - 45 seconds,
of all dimming changes.
12
. Indicator Dial shows the rate and progress of all dimming
changes.
13
. Rehearsal Switch allows the WHITE or GREEN
PRESET facilities to be held.
14
. Blackout A, Blackout B and Dead Blackout switches.
*These pushes have a second function against a heavy spring