Electrical
Each dimmer module shall contain one or
two single pole circuit breakers, associated
solid state switching modules, filters, power
and control components.
Dimmer electronics shall be completely solid
state.They shall utilize two silicon controlled
rectifiers in a back-to-back electrical configuration.The full load of the circuit is to be
carried and controlled by the silicon controlled rectifiers.
Each dimmer shall be protected by a fully
magnetic circuit breaker of the appropriate
current rating and 10,000 AIC surge rating
mounted on the face plate of the dimmer
module so that the trip current is not affected
by ambient or rack temperature.The circuit
breaker shall be rated for tungsten loads
having an inrush rating of no less than 20
times normal current and shall disconnect the
power to the dimmer module before damage
can be done to the dimmer power components.The circuit breakers shall be rated for
100 percent switching duty applications and
shall be a UL and cUL recognized device.
Filtering
Each dimmer module shall have an integral
inductive filter to reduce the rate of current
rise time resulting from the SCR switching
on.The filter shall limit objectionable harmonics, reduce lamp filament sing and limit
the radio frequency interference on line and
load conductors.
Type (i) dimmers shall have a rise time of not
less than 350 microseconds measured at 90
degrees conduction angle from 10% to 90%
of output wave form with dimmer operating
at maximum load.Voltage rate of rise (slew
rate) must not exceed 420 millivolts per
microsecond in any point of the wave under
full load conditions.
Type (ii) dimmers shall have a rise time of
not less than 500 microseconds measured at
90 degrees conduction angle from 10% to
90% of output wave form with dimmer operating at maximum load.Voltage rate of rise
(slew rate) must not exceed 300 millivolts
per microsecond in any point of the wave
under full load conditions.
Type (iii) dimmers shall have a rise time of
not less than 800 microseconds measured at
90 degrees conduction angle from 10% to
90% of output wave form with dimmer operating at maximum load.Voltage rate of rise
(slew rate) must not exceed 210 millivolts
per microsecond in any point of the wave
under full load conditions.
The use of type i, ii, or iii dimmers shall not
reduce rack density. 2.4kW and 6.0kW modules are available as types i, ii, or iii.12.0kW
modules are available as type i.
Solid State Relay (SSR)
SSR devices shall be encapsulated, epoxy
filled high impact plastic cases with optically
isolated firing circuits, control circuitry, and
two silicon controlled rectifiers (SCRs).There
shall be a minimum of 2,500 volts RMS of
isolation between the AC line and the control
lines of the SSR.
The SCR shall be in an industry standard
format that is easily field replaceable without
removing any other electrical or electronic
devices.
Performance
The dimmer shall be capable of “hot patching” cold incandescent loads up to its full
rated capacity without malfunction with the
control signal at full ON.
The dimmer power efficiency shall be at
least 97% at full load with a no load loss of
3V for type (1) dimmers.
Strand Lighting Inc
PO Box 9004 18111 South Santa Fe Avenue Rancho Dominguez, CA 90221, USA Tel: +1 310 637 7500 Fax +1 310 632 5519
Second Floor 151 West 25th Street New York, NY 10001, USA Strand Lighting Inc. Tel: +1 212 242 1042 Fax +1 212 242 1837
Strand Lighting (Canada) Inc / Eclairages Strand (Canada) Inc
2430 Lucknow Drive No 15 Mississauga Ontario L5S 1V3 Canada Tel: +1 905 677 7130 Fax: +1 905 677 6859
LONDON - BERLIN - ROME - PARIS - MOSCOW - TORONTO - LOS ANGELES - NEW YORK - HONG KONG www.strandlighting.com
The Company reserves the right to make any variation in design or construction to the equipment described.
© Strand Lighting Ltd. 1998.
Strand™, Strand Lighting™, Strand Quartzcolor™ are trademarks of Strand Lighting Limited and
Strand Lighting Inc.
Ordering Information
120 Volt Standard Dimmer Modules
(Suitable for 90V to 120V)
Cat. No. Power Firing Type Rise Time
72314 Dual 2.4kW FF Dimmer 350 µs
72315 Dual 2.4kW FF Dimmer 500 µs
72316 Dual 2.4kW FF Dimmer 800 µs
72318 Dual 2.4kW HF Dimmer 350 µs
72382 Dual 2.4kW FF Dim/ 350 µs
Non-Dim
72384 Dual 2.4kW FF Non-Dim/ 350 µs
Dim
72386 Dual 2.4kW FF Non-Dim
72302 Dual 2.4kW Dual Constant
72354 Dual 1.8kW FF Dimmer 300 µs
72356 Dual 1.8kW FF Dimmer 450 µs
72324 6.0 kW FF Dimmer 350 µs
72325 6.0 kW FF Dimmer 500 µs
72326 6.0 kW FF Dimmer 800 µs
72332 12.0kW FF Dimmer 350 µs
72310 2.4kW
FF Dim/GFCI
800 µs
120 Volt Status Reporting Dimmer
Modules (Suitable for 90V to 120V)
Cat. No. Power Firing Type Rise Time
72311 Dual 2.4kW FF Dimmer 350 µs
72312 Dual 2.4kW FF Dimmer 500 µs
72313 Dual 2.4kW FF Dimmer 800 µs
72317 Dual 2.4kW HF Dimmer 350 µs
Cat. No. Power Firing Type Rise Time
72381 Dual 2.4kW FF Dim/ 350 µs
Non-Dim
72383 Dual 2.4kW FF Non-Dim/ 350 µs
Dim
72385 Dual 2.4kW FF Non-Dim
72351 Dual 1.8kW FF Dimmer 300 µs
72353 Dual 1.8kW FF Dimmer 450 µs
72321 – 6.0kW FF Dimmer 350 µs
72322 – 6.0kW FF Dimmer 500 µs
72323 – 6.0kW FF Dimmer 800 µs
72331 – 12.0kW FF Dimmer 350 µs
72307 – 2.4kW FF Dimmer/ 800 µs
GFCI
220 Volt Standard Dimmer Modules
(Suitable for 220V to 240V)
Cat. No. Power Firing Type Rise Time
72364 Dual 3.3kW FF Dimmer 190 µs
72366 Dual 3.3kW FF Dimmer 435 µs
72368 Dual 3.3kW HF Dimmer 190 µs
72392 Dual 4.4kW FF Dim/ 190 µs
Non-Dim
72394 Dual 4.4kW Non-Dim/ 190 µs
FF-Dim
72396 Dual 4.4kW Non-Dim 190 µs
72373 Dual 5.5kW FF Dimmer
72366 Dual 5.5kW FF Dimmer 435 µs
72378 11.0kW FF Dimmer 190 µs
220 Volt Status Reporting Dimmer
Modules (Suitable for 220V to 240V)
Cat. No. Power Firing Type Rise Time
72361 Dual 3.3kW FF Dimmer 190 µs
72363 Dual 3.3kW FF Dimmer 435 µs
72361 Dual 3.3kW HF Dimmer 190 µs
72391 Dual 4.4kW FF Dim/ 190 µs
Non-Dim
72393 Dual 4.4kW Non-Dim/ 190 µs
FF-Dim
72395 Dual 4.4kW Non-Dim
72371 Dual 5.5kW FF Dimmer 190 µs
72374 5.5kW FF Dimmer 435 µs
72377 11.0kW FF Dimmer 190 µs
Note: 220 modules can be used as high as 240 VAC
without modification, however the listed power rating
will be increased by a factor of 1.09.A 3.3kW dimmer
shall therefore be capable of driving a 3.6kW load.
Dimmer risetimes will be reduced by a factor of
approximately 0.93 when used at the higher voltage.
Cat. No. Description
72303 Test Module
72301 Single Filler Module
72304 Row Filler Module =
(6 Dual Module Spaces)