THE ORIGINAL
SINCE 1972
AUTOMATIC COOKTOP FIRE SUPPRESSION
STOVETOP FIRESTOP RANGEHOOD® SPECIFICATIONS
INTENDED USE
ACTIVATION METHOD
POWDER DISPERSAL METHOD
PRIMARY SUPPRESSION AGENT
INTENDED APPLICATION
REQUIRED VERTICAL CLEARANCE
REQUIRED HORIZONTAL DISTANCE
FROM BACK WALL
WEIGHT—TOTAL PRODUCT (OUNCES)
WEIGHT—POWDER (OUNCES)
Indoor, residential stovetop grease fires (not more than 3/8”
oil depth)
Automatic when there is direct, sustained contact with a
flame
Gravity (non-pressurized)
Non-Toxic dry powder
Traditional range hoods
27-35” between the burner and the bottom of the surface
where the magnet will attach
Position each canister at the midpoint between the center of
the front and back burners on each side
Approximately 12 oz.
Approximately 9 oz. (per canister)
HEIGHT (INCHES)
LENGTH (INCHES)
WIDTH (INCHES)
INSTALLATION METHOD
NUMBER OF DEVICES NEEDED TO
COVER A 4-BURNER STOVETOP
TESTS PERFORMED
EFFECTIVE LIFE
3.5” (including magnet assembly)
3.4” (diameter)
3.4” (diameter)
Industrial strength magnet holds device to range hood. Alternative mounting kits available upon request
Two (one pair)
Device and dry powder tested by an independent nationally
recognized testing laboratory (NRTL)
6 years, replace upon activation or before “remove or
replace before” date found on label