Störk-Tronic ST710-PCA.07 Wiring Diagram

ST710-PCA.07
Timer switch
Order number 900211.002
Wiring diagram
The freely programmable timer switch has two adjustable derivative timers and two elapsing tim­ers. Together with the possibility of various parameters, two output contacts and two switching inputs will allow the employment of any applications one can think of. The timer can be started and stopped both with the front buttons and with the switching inputs.
Front size: 84mm x 42mm Panel cut-out: 67.5mm x 31.5mm Tigntness: Front IP65 Connector: plug and socket
Order number: 900211.002 Page 1
Order number: 900211.002 Page 2
SOFTWARE .07
Adjustment options
Key 1: UP
By pressing this key together with the SET key you can increase the parameter or pa­rameter value or scroll the parameter list.
Key 2: DOWN
By pressing this key together with the SET key you can decrease the parameter or pa­rameter value or scroll the parameter list.
Key 3: Set
Show the operating time t1. T1 can be adjusted together with the UP or DOWN key.
Key 4: Start
Start of the timer.
Key 5: Stop
With this key the timer can be stopped and the buzzer can be cancelled.
Order number: 900211.002 Page 3
Function Description
Derivative
time
T
A1
S
T
ART
K1 on
K1 o
f
f
K2 on
Buzzer on
END
K2 o
f
f
Buzzer off
Derivative
time
T
A2
Operating
time t1
Operating
time P15
The timer is always equipped with two output contacts and a buzzer.
The entire process consists of the following successive phases:
- Derivative time TA1 for relay K1 (relay K1 is still inactive)
- Active phase t1 for relay K1
- Derivative time TA2 for relay K2 (the relay K2 is still inactive)
- Active phase P15 for relay K2 (possibly together with the buzzer)
The timer is started with key 4 or switching input E1 (see parameter P10). Stop the timer at any time with key 5 or switching input E2 (see parameter P11).
The start and stop functions via the switching inputs are edge-controlled, only a change of state in the right direction (see parameters P5 or P6) leads to an action. The most recent command is effective.
Please note that the buzzer function (if activated with P9) is not necessarily connected to the output K2. The buzzer sounds at the end of the timer or at the end of P15, but is active at one of the special functions (P16 =
1) regardless of K2.
Timer and display
As for the operating time t1 it is possible to display the time remaining or the elapsed time (see parameter P12). As for the derivate times, always the respective remaining time is indicated.
If an acknowledgment for K2 provided (see parameter P13), it is indicated until acknowledgment after the timer has elapsed. If time ranges with colon are selected, the colon is flashing during the timer. For the flashing frequency the following applies:
- During the active phase of the relay K1 the colon flashes every second.
- During the derivate times and during the active phase of the relay K2 the colon flashes with in­creased frequency.
- When the timer has elapsed the colon stops flashing and remains lit continuously.
It is possible to specify a continuous mode, in which all phases are automatically restarted.
It can be selected (see P17) if the display returns at Stop and after acknowledgment of the set time t1, or remains on the respective past value in the display mode.
After the timer stops and after an acknowledgment the display can show again the operating time t1 or the respective elapsed timer value is indicated, depending on parameter P17.
Order number: 900211.002 Page 4
First control level:
Para­meter
Function
Adjustable range
Standard setting
Customer setting
t1
Operating time (setpoint) K1
see P1
1:11 hrs
Para­meter
Function
Adjustable range
Standard setting
Customer setting
P1
Operating range t1 (K1)
0: 0...99.9 sec.
2: 0...99 Std. 59 min.
2
P2
Operating range TA1, TA2
0: 99.9 sec. 1: 99 min. 59 sec.
0
P3
Derivative time TA1
0... see P2
0 sec.
P4
Derivative time TA2
0... see P2
0 sec.
P5
Function input E1 (START)
0: start with closed contact 1: start with opened contact
0
P6
Function input E2 (STOP)
0: stop with closed contact 1: stop with opened contact
0
P7
Function output K1
0: activated during timer 1: deactivated during timer
0
P8
Function output K2
0: activated during timer 1: deactivated during timer
0
P9
Buzzer function K2
OFF: no buzzer
2: intermittent
1
P10
Trigger start function
0: key or switching input
1: only switching input
0
P11
Trigger stop function
0: key or switching input
1: only switching input
0
P12
Display mode operating time t1
0: countdown 1: elapsed time
0
P13
Stop of K2
0: with STOP
3: P15 starts after t1+TA2, restart
0
Adjusting the operating time
By pressing th SET-key the operating time t1 is indicated. By additionally pressing the UP- or DOW N-key the time can be set.
Second control level (P-parameter):
Adjusting of timer parameters
Simultaneously pressing the UP and DOWN key for at least 4 seconds opens an intermediate menu with “PA0” in the display.
If there is no password specified for access to the actual parameter list (= factory setting), a short press of the SET key opens the timer parameters, starting with P1
With the UP and DOWN keys the list can be scrolled in both directions.
Pressing the SET key will give you the value of the respective parameter. Pressing also the UP or DOWN key at the same time the value can be adjusted.
Return to the initial position takes place automatically, if no key is pressed for 60 seconds, or by simultane­ously pressing the UP and DOWN key for approx. 4 seconds
(after t1+TA2 or after P15, see P13)
1: 0...99 min. 59 sec.
1: continuous
1: only key
1: only key
(no timer P15 for K2 if P13=0 or P13=1)
Order number: 900211.002 Page 5
1: with STOP or START 2: P15 starts after t1+TA2, no restart
Para­meter
Function
Adjustable range
Standard setting
Customer setting
P14
Operating range K2
0: 0...99.9 sec. 1: 0...99 min. 59 sec.
1
P15
Operating time K2
0... see P14
2 sec.
P16
Special functions
0: Normal function
during timer
0
P17
Display after Stop and buzzer ac­knowledgment
0: elapsed time 1: operating time t1
0
Pro
Show program version
-----
-----
Parameter description
P1: Operating range K1
There are three operating ranges available: seconds (with 1/10 of a second), minutes/seconds, and hours/minutes.
P5: Function input E1
“Start with closed contact” means that closing the switching input E1 starts the timer. “Start with opened contact” means that opening the switching input E1 starts the timer.
P6: Function input E2
Same function as parameter P5, regarding the Stop function.
P7: Function output K1 P8: Function output K2
The setting “activated during timer” means the respective relay is closed (energized) during the timer. In the remaining time it is opened (de-energized). The setting “deactivated during timer” means the respective relay is opened during the timer. In the remain­ing time it is closed.
P9: Buzzer function K2
The buzzer can be activated together with the relay K2. It sounds continuously or intermittently. With the parameter setting P16 = 1 the buzzer sounds independently of the output K2.
P10: Trigger start
The start function can be triggered either by the switching input E1 and/or by the key 4. This is regardless of the trigger of the stop function.
P11: Trigger stop
The stop function can be triggered either by the switching input E2 and/or by the key 5. This is regardless of the trigger of the start function.
P12: Display mode operating time t1 (K1)
With the setting “countdown” the current time goes from t1 to 0. With the setting “elapsed time” the current time goes from 0 up to t1.
P13: Stop of timer K2
0: There is no specific operating time for K2; K2 is active until pressing the STOP key 1: Same as “0”, but it’s possible to do a restart without previous stop. 2: Operating time in parameter P15 will take effect; after its expiration the timer stops. 3: Operating time in parameter P15 will take effect; after its expiration the timer restarts. The timer is now in continuous operation until a manual stop.
P14: Operating range K2
There are two operating ranges available: seconds (with 1/10 of a second) and minutes/seconds.
1: both relays as K1, K2 inactive during timer 2: both relays as K2, K1 inactive
Order number: 900211.002 Page 6
P15: Operating time K2
Display
Cause
Remedy
Flashing colon
Timer was started
Buzzer sounds
Timer was terminated
EP
Error in parameter memory Data loss
Repair
This parameter sets the operating time for K2
P16: Special functions
For special use cases it is possible to activate both relays during the operating time t1 (then inactive during P15) or vice versa. Please note that the buzzer is linked to the final sequence stop, i.e. to P15. If P16 = 1 it will sound regardless of the output K2.
P17: Display after Stop and buzzer acknowledgment
With P17=1 the display shows the operating time 1 after Stop or acknowledgment of the buzzer.
Pro: Show program version
The value cannot be changed
Status- and error messages
Order number: 900211.002 Page 7
Technical data of ST710-PCA.07
Inputs E1: external contact, potential-free, timer start function E2: external contact, potential-free, timer stop function
Outputs K1: Relay 8(1.5)A 250V, normally-open contact K2: Relay 8(1.5)A 250V, normally-open contact
Installed buzzer, ca. 85dB
Display One 4-digit LED-Display, height 13mm, for timer display, colour red Two LEDs, for status display of the outputs K1 and K2
Power supply 230 V 50/60 Hz, power consumption max. 4VA
Connectors
12-pole plug and socket, spacing 5.0 mm, for cable up to 2.5 mm²
Ambient conditions: Storage temperature -20°C...+70°C Operating temperature 0...55°C Relative humidity max. 75%, without dew
Weight ca. 300g
Enclosure Front IP65, IP00 from back
Installation data Unit is to be installed in an instrument panel. Front size 84 x 42 mm Panel cut-out 67.5 x 31.5 mm Installation depth ca. 85 mm Mounting by fixing strap.
Order number: 900211.002 Page 8