StorCase Technology InfoStation User Manual

StorCase® Technology
InfoStation
®
14-Bay 2Gbps Fibre Channel External Expansion Chassis
i
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
StorCase Technology, Inc.
17600 Newhope Street
Fountain Valley, CA 92708-9885
Phone (714) 438-1850 Fax (714) 438-1847
StorCase® Technology
InfoStation
®
14-Bay 2Gbps Fibre Channel
External Expansion Chassis
Part No. D89-0000-0210 B00 October 2003
ii
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
STORCASE TECHNOLOGY, Incorporated (StorCase) warrants that its products will be free from defects in material and workmanship, subject to the conditions and limitations set forth below. StorCase will, at its option, either repair or replace any part of its product that proves defective by reason of improper workmanship or materials. Repair parts or replacement products will be provided by StorCase on an exchange basis, and will be either new or reconditioned to be functionally equivalent to new.
This warranty does not cover any product damage that results from accident, abuse, misuse, natural or personal disaster, external power surge or failure, or any unauthorized disassem­bly, repair or modification. StorCase will not be responsible for any software, firmware or other customer data stored within, or interfacing with a StorCase product.
Duration of Warranty
Seven-Year Warranty: The following StorCase products are covered by this warranty for
a period of seven (7) years from the original date of purchase from StorCase or its authorized reseller: all Data Express® removable device enclosures and all StorCase interface cables and accessories specifically intended for use with these products. Data Silo®, Data Stacker® and InfoStation® products are covered by this warranty for a period of seven (7) years, excepting the RAID controller, power supply, fan and blower components, which are covered by the three-year warranty described below.
Three-Year Warranty: The following StorCase products are covered by this warranty for a period of three (3) years from the original date of purchase from StorCase or its authorized reseller: all Rhino®JR external expansion chassis, all RhinoJR removable drive enclosures, and all RAID controller modules. In addition, the following components of the Data Express, Data Silo, Data Stacker, InfoStation products are subject to warranty for a period of three (3) years: all power supplies, fans and blowers.
Warranty Claim Requirements
To obtain warranty service, the defective product must be returned to your local authorized StorCase dealer or distributor, or, with prior StorCase approval, to the StorCase factory service center.
For defective products returned directly to StorCase, a Return Material Authorization (RMA) number must be obtained by calling StorCase Customer Service at (714) 445-3455. The RMA number must be prominently displayed on the outside of the return package. Shipments must be freight-prepaid and insured, and must include the product serial number, a detailed description of the problem experienced, and proof of the original retail purchase date. Products must be properly packaged to prevent damage in transit. Damage resulting from improper packaging will not be covered by this warranty. The StorCase factory service center is located at 3400 S. Susan Street, Storage RMA Dept., Santa Ana, California 92704, U.S.A.
LIMITED WARRANTY
iii
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Free Technical Support
StorCase provides free technical support. If you experience any difficulty during the installation or subsequent use of a StorCase product, please contact StorCases Technical Support Department prior to servicing your system. This warranty covers only repair or replacement of defective StorCase products, as described above. StorCase is not liable for, and does not cover under warranty, any costs associated with servicing and/or installation of StorCase products.
StorCase Technical Support can be reached in the U.S. at (714) 438-1858 or toll-free at (888) 435-5460 (U.S. and Canada only). StorCase European Technical Support can be reached in the U.K. at +44 (0) 1932 738900.
Disclaimers
The foregoing is the complete warranty for the products identified above and supersedes all other warranties and representations, whether oral or written. StorCase expressly disclaims all warranties for the identified products, which are not stated herein, including, to the extent permitted by applicable law, any implied warranty of merchantability or fitness for a particular purpose. In no event will StorCase be liable to the purchaser, or to any user of a StorCase product, for any damages, expenses, lost revenues, lost savings, lost profits, or any other incidental or consequential damages arising from the purchase, use or inability to use a StorCase product, even if StorCase has been advised of the possibility
of such damages.
Copyright © 2003 StorCase Technology. All rights reserved. All registered trademarks are the property of StorCase Technology. All other logos and trademarks are properties of their respective companies.
iv
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Company Name:
Corporate Office Address:
Manufacturing Address:
Product Name:
Model Number:
EMC Directives: (89/336/EEC)
Safety Standards: CSA (NRTL/C)
TUV
EMI Standards:
EMC Standards:
Year of Manufacture:
Signature:___________________ Full Name: Dieter Paul Position: President
Conforms to the following standards:
StorCase Technology, Inc.
17600 Newhope Street Fountain Valley, CA 92708
17600 Newhope Street Fountain Valley, CA 92708
InfoStation 14-Bay Fibre Channel
S10D106, S10D111
ITE Emission
- EN 55022: 1998
- EN 61000-3-2 Harmonic Current
- EN 61000-3-3 Voltage Fluctuations and Flicker EN 55024: 1998 ITE Immunity
- IEC 61000-4-2 - IEC 61000-4-6
- IEC 61000-4-3 - IEC 61000-4-8
- IEC 61000-4-4 - IEC 61000-4-11
- IEC 61000-4-5
CAN/CSA-C22.2 No. 60950 UL 60950, Third Edition
EN 60950: 2000
FCC Part 15, Class A
AS/NSZ 3548 Information Technology Equipment Supplier's Code Number N10664
2002
Declaration of Conformity
v
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Federal Communications Commission (FCC) Statement
RADIO FREQUENCY INTERFERENCE STATEMENT
You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate that equipment.
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Important Safety Instructions
1. Read all these instructions.
2. Save these instructions for later use.
3. Follow all warnings and instructions marked on the product.
4. Do not use this product near water.
5. This product should be operated from the type of power source indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company.
6. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous voltage points or other risk. Refer all servicing to service personnel.
7. Handling certain plastic coated cords or cables associated with this product may expose you to lead, a chemical known to cause birth defects or other reproductive harm. Wash your hands after handling cable(s).
Wichtige Sicherheitshinweise
1. Diese Hinweise sollten vollständig durchgelesen werden.
2. Diese Hinweise für einen späteren Gebrauch aufbewahren.
3. Allen auf dem Gerät angebrachten Warnungen und Hinweisen folgen.
4. Das Gerät nicht in der Nähe von Wasser verwenden.
5. Das Gerät nur mit dem Aufkleber bezeichneten Netzspannung betreiben. Bei Fragen über die Art der Netzspannung sollte der Händler oder das Energieversorgungsunternehmen zu rate gezogen werden.
6. Nicht versuchen das Produkt selbst zu reparieren. In allen Produkten existieren gefährliche elektrische Spannugen. Nicht das Gehäuse öffnen.
7. Wartungsarbeiten nur von qualifiziertern Kundendienstpersonal ausführen laßen.
vi
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Table of Contents
INTRODUCTION ..................................................................................................................... 1
Packaging Information .................................................................................................. 1
Serial Number ................................................................................................................ 1
General Description ...................................................................................................... 2
Front Panel ............................................................................................................ 4
Rear Panel ............................................................................................................. 5
INFOSTATION USER INTERFACE ......................................................................................... 7
LED Indicator and Control Panel ................................................................................... 7
LED Indicator/Control Panel Components ............................................................ 7
Drive Carrier Interface Panel ............................................................................... 9
Inserting a Drive Carrier (with Drive Installed) .......................................................... 10
Removing a Drive Carrier (with Drive Installed) ....................................................... 10
Configuring Device and Chassis Settings ................................................................. 10
FIBRE CHANNEL CONFIGURATIONS ................................................................................. 11
Port Bypass (PBP) Module ......................................................................................... 11
PBP Module LEDs ............................................................................................... 12
SFP Module and Cable Installation ............................................................................. 13
FC Loop and Speed Configuration ............................................................................. 17
Hardware Compatibility .............................................................................................. 17
TYPICAL FIBRE CHANNEL CONFIGURATIONS ................................................................. 18
APPENDICES ........................................................................................................................ 25
Appendix A - Specifications/Dimensions .................................................................. 26
Appendix B - Optional Accessories ......................................................................... 30
Port Bypass Module ........................................................................................... 30
SFP Modules ....................................................................................................... 31
HSSDC2 (Copper) SFP Module .................................................................. 31
LC (Optical) SFP Module ............................................................................ 31
Patch Cable Kit ................................................................................................... 32
Slide Rail Kit ......................................................................................................... 33
Optional Power Supply/Blower Module ............................................................ 34
Drive Carrier ........................................................................................................ 35
Carrying Case ..................................................................................................... 36
Rack-to-Tower Conversion Kit .......................................................................... 37
InfoStation Monitoring Utility (InfoMon) .............................................................. 38
Reader's Comments............................................................................................................ 39
vii
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
List of Figures
Figure 1: InfoStation 14-Bay FC Chassis ..................................................................... 2
Figure 2: InfoStation Front Panel ................................................................................... 4
Figure 3: InfoStation Rear Panel .................................................................................... 6
Figure 4: Port Bypass Module ....................................................................................... 6
Figure 5: LED Indicator and Control Panel .................................................................... 7
Figure 6: InfoStation Drive Carrier Interface ................................................................ 9
Figure 7: PBP Module ................................................................................................... 11
Figure 8: PBP Module LEDs ......................................................................................... 12
Figure 9A: Installing the LC (optical) SFP Module into the PBP Module ....................... 14
Figure 9B: Installing the HSSDC2 (copper) SFP Module into the PBP Module............. 14
Figure 10: Installing the Cables into the SFP Modules ................................................. 15
Figure 11: Removing the Optical SFP Module from the PBP Module ........................... 16
Figure 12: Typical Single Loop 1x14 Configuration (Single Chassis) ......................... 18
Figure 13: Typical Single Loop 1x14 Configuration (Multiple Chassis) ....................... 19
Figure 14: Typical Dual Loop 1x14 Configuration with Loop Redundancy ................ 20
Figure 15: Typical Dual Loop 1x7 Configuration .......................................................... 21
Figure 16: Typical Dual Loop 1x7 Configuration with Loop Redundancy .................. 22
Figure 17: Typical Quad Loop 1x7 Configuration ........................................................ 23
Figure A-1: InfoStation Physical Dimensions.................................................................. 29
Figure B-1: PBP Module ................................................................................................... 30
Figure B-2: HSSDC2 (copper) SFP Modules .................................................................. 31
Figure B-3: LC (optical) SFP Modules ............................................................................. 31
Figure B-4: Patch Cable Kit ............................................................................................. 32
Figure B-5: Rack Mount Slide Rail Kit.............................................................................. 33
Figure B-6: Power Supply/Blower Module ..................................................................... 34
Figure B-7: Drive Carrier ................................................................................................. 35
Figure B-8: Carrying Case ............................................................................................... 36
Figure B-9: Rack-to-Tower Conversion Kit .................................................................... 37
viii
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
NOTICE: This User's Guide is subject to periodic updates without notice. While reasonable
efforts have been made to ensure accuracy of this document, Storcase Technol­ogy, Inc. assumes no liability resulting from errors or omissions in this publication, or from the use of the information contained herein.
Please check the StorCase web site at http://www.storcase.com or contact your StorCase representative for the latest revision of this document.
List of Tables
Table 1: Drive Carrier Interface Components ................................................................... 9
Introduction 1
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
INTRODUCTION
CAUTION: The InfoStation contains NO USER SERVICEABLE parts inside the unit. Refer ALL
servicing to qualified service personnel!
This unit has more than one power supply cord. Disconnect two power supply cords before servicing to avoid electric shock.
NOTES: The installation, configuration, and use of the StorCase InfoStation chassis
requires a certain level of expertise and experience on the part of the user/ integrator. Since there are many configuration options and variables (ie. host platforms, applications, etc), only general/typical configuration guidelines will be discussed in this User's Guide.
For installation information, refer to the InfoStation Installation Guide.
PackagingInformation
The StorCase Technology InfoStation external expansion chassis is shipped in a container designed to provide protection and prevent damage during shipment, as confirmed by the International Safe Transit Association (ISTA Procedure 1A). The InfoStation was carefully inspected before and during the packing procedure at the factory. Evidence of any damage to the InfoStation should be reported to the shipper immediately.
If the wrong InfoStation model has been received, please call your reseller or StorCase at (800) 435-0642 to arrange for a Return Material Authorization (RMA). StorCase cannot ac­cept returns which do not display an RMA number on the outside of the package. Return the unit with all the original packing materials.
Before removing any component from its packaging, discharge any static electricity by touching a properly grounded metal object.
Serial Number
The InfoStation is labeled with a serial number. This number must be reported to the StorCase Customer Service Representative in order to receive a Return Material Authorization (RMA) for warranty claims. Locate the serial number label and record the number in the space provided below.
InfoStation Serial Number:
2 Introduction
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Figure 1: InfoStation 14-Bay Fibre Channel Chassis
GeneralDescription
The StorCase® Technology InfoStation® intelligent 3U rack-mount expansion chassis is designed to support the latest high-density, high-speed 2Gbps/1Gbps Fibre ChanneI disk drive technologies for use in network server, fault-tolerant and/or mission-critical applica­tions. The InfoStation is designed to support 3.5" form factor, low profile (1" high) Fibre Channel drives.
The InfoStation's dual backplane design can accommodate up to fourteen (14) Fibre Channel drives (Figure 1) and up to four (4) Fibre Channel Arbitrated Loops (FC-ALs) with 2Gbps operation. Each chassis is constructed of rugged steel and lightweight aluminum, and is equipped with either one (1) or two (2) 650 watt redundant, hot-swappable power supply/ blower modules, and a User Interface designed to provide visual chassis feedback.
The InfoStation options include an FC Port Bypass Module and Small Form-Factor Pluggable (SFP) Modules, for quad FC loop configurability. Additional PBP and SFP modules are available to accommodate a variety of configurations, interfaces, and applications. Refer to Appendix B for further information on optional InfoStation accessories.
The InfoStation also incorporates "Soft Start" circuitry which eliminates in-rush current to each of the installed drives during spin-up, as well as avoid power arcing during drive insertion.
Another unique feature of the InfoStation is the InfoMon® monitoring utility program. InfoMon is a console utility that provides the InfoStation with web-based monitoring capability via a serial connection. InfoMon also provides the User the ability to easily configure both device and chassis settings with a few clicks of the mouse!
In addition, InfoMon allows the User to monitor the statuses and temperatures of individual InfoStation modules and drive bays, etc., and can provide "real-time" updates via an Internet connection. With the recent addition of the InfoMon Call Home feature, this information can also be sent to a specific site for access by StorCase technical support staff in order to assist with system troubleshooting. The Call Home feature also provides the ability to set-up a paging function for notification of environmental alarm or warning conditions.
14FC_01
Introduction 3
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
The latest versions of the InfoMon utility program and User's Guide can be downloaded (free of charge) from the StorCase web site (http://www.storcase.com). Contact StorCase for further information. Refer to Appendix B for further information on optional InfoStation accessories.
Using a modular approach supported by redundant features and hot swapping capabilities, the InfoStation will provide continued data availability and allow for ease of maintenance and minimal system down time.
The modular and scalable design of the InfoStation chassis also allows a variety of future product upgrades to be offered. Upgrade modules (providing remote diagnostics capabilities and SES or SNMP compliance) will also be available as options in the near future.
This User's Guide describes the steps required for installing drive(s) into the InfoStation external expansion chassis. This guide is intended to supplement documentation provided with the host computer system, the operating system, and the drive(s) to be installed within the InfoStation.
Features:
 3U rack mount chassis  Fourteen (14) removable low-profile drive carriers  Capable of 2Gbps or 1Gbps FC-AL/FC-SW operation  Supports single, dual, or quad FC-AL configurations  Configurable for 7 or 14 drive loops  Connection flexibility with optical or copper SFP Modules  Supports clustering  Supports daisy-chaining  Supports drive hot swapping  User Interface Panel provides configuration and communication status  RS-232 serial port provides interface for monitoring, configuration, and control  Scalable backplane design  Corrosion-resistant steel construction  One (1) or two (2) 650W hot-swappable power supply/blower modules (depending on
model). P.S. Module contains two (2) high-pressure/variable-speed blowers.
 Audible alarm
"Soft Start" circuitry Web-based monitoring utility (InfoMon)
 Status indicators on each drive carrier  7-year limited warranty* and free 24/7 technical support
* 3 year limited warranty on Power & Cooling Modules
4 Introduction
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
FrontPanel
(Figure 2)
LED Indicator and Control Panel - LED panel displays system statuses, alarms,
and warnings. Refer to section "InfoStation User Interface" for further information.
SCA Drive Carrier(s) - Accommodate up to fourteen (14) 3.5" low-profile Fibre
Channel devices. Backplane design with direct-connect SCA connectors eliminates cable connections to FC drives, increases data integrity, and supports drive hot swappability.
Drive Carrier LED(s) - Provides the following information:
Drive Ready - Indicates that the drive is properly installed and ready for
access.
Drive Activity - Indicates that the drive is being accessed. Drive Fault - Indicates a drive failure.
Key Lock(s) - Assure proper seating of the drive carrier within the chassis and
prevent unauthorized removal or installation of the carrier.
NOTE: The key lock is only to prevent unauthorized removal or installation of the
drive carrier. Locking the key lock is not requried for drive carrier oper­ation.
Chassis Handle(s) - Provide a sturdy grip for the installation and removal of the
rack-mount chassis.
Figure 2: InfoStation Front Panel
Chassis
Handle
SCA Drive
Carrier
Drive Carrier
Handle
Key
Lock
Drive Carrier
LEDs
LED Indicator and
Control Panel
14FC_02
RS-232
Serial Port
Introduction 5
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
RearPanel
(Figure 3)
NOTE: Blank plate (provided) must be installed if any module slot is left empty. Instal-
lation of the blank plate is necessary for proper cooling inside chassis.
Port Bypass Module "A" (Figure 4) - InfoStation comes equipped with one (1) Port
Bypass (PBP) Module, for dual FC loop configurability.
Port Bypass Module "B" Option - Allows the installation of an optional PBP
Module, for quad loop configurability. Refer to Appendix B for further information.
Power Supply/Blower Module(s) - Depending on the model, either one (1) or
two (2) 650W redundant, hot swappable power supply modules. Each module features overvoltage and overcurrent protection, total usage hours, and power supply fault detection.
Each module also contains two (2) high-pressure, variable-speed blowers for ample chassis cooling (79 CFM per module).
WARNING: DO NOT USE MODULE HANDLES TO LIFT CHASSIS! These
handles are specifically designed for the installation and re­moval of modules only!
Module LED(s) -
Green LED - Steady glow indicates normal power supply operation.
No glow indicates no A/C power or abnormal DC voltage range.
Red LED - Flashing indicates temperature or over/undervoltage condi-
tions.
Power Switch(es) - Rocker switch(es) control power to the power supply module(s).
A/C Power In - Accepts U.S. and other available international standard power cords.
Module Option - Allows the installation of StorCase upgrade products such as an
optional SNMP upgrade module. Refer to Appendix B for further information.
6 Introduction
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Figure 3: InfoStation Rear Panel
(Dual Power Supply/Blower Module Version shown)
Port Bypass
Module A
Captive
Screw
Power Supply
Module LEDs
Power Supply
Handle
Power Supply
Module #1
Blower
Vent
Power Switch
14FC_03
Module
Option
Port Bypass
Module B
Option
Power Supply
Module #2
A/C
Power In
Figure 4: Port Bypass Module
14FC_04
LEDs
Locking
Thumbscrew
PBP Module
Handle
HSSDC2
SFP Module
(Optional)
SFP
Cages
In InOut Out
Loop B Loop A
User Interface 7
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
INFOSTATION USER INTERFACE
LED Indicator and Control Panel
Each InfoStation provides the user with a visual indication of chassis configurations and communication statuses, in addition to providing an RS-232 connection for system environ­mental monitoring, configuration, and control (Figure 5).
Figure 5: LED Indicator and Control Panel
LED Indicator/Control Panel Components
Power (Green)- ON = Power to the chassis is on.
Warning (Amber) - ON = One or more warning conditions
Fault (Red) - ON = One or more fault conditions
Mute (Amber) - ON = Audible alarm is disabled
Override (Amber) - ON = Warning condition commands are overridden
NOTE: Factory default is OFF (recommended).
2Gbps - ON = 2Gbps operation (Factory Default)
OFF = 1Gbps operation
14FC_06
Warning
Mute
2Gbps
RS-232 Serial Port
RB Com
Power
Fault Override
Bypass Reset
RA Com
Select
8 User Interface
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Bypass - ON = One or more drives are being bypassed
Reset - Resets InfoStation User Interface Module (will not reset FC
loops)
RS-232 Serial Port - RS-232 serial connection used for InfoStation external monitor-
ing and configuration
RA Com - Factory Reserved
RB Com - Factory Reserved
Select Button - Factory Reserved
User Interface 9
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
The Drive Carrier Interface consists of the following indicators:
Table 1: Drive Carrier Interface Components
Figure 6: InfoStation Drive Carrier Interface
Drive Carrier Interface Panel
Each InfoStation drive carrier provides a User interface for individual carrier operation.
Drive Ready LED
Drive Fault LED
Steady glow indicates that drive is inserted and ready for access.
Flashing indicates that drive is inserted and in the process of being powered up.
Steady glow indicates drive failure.
Steady glow indicates drive is being accessed.
Drive Activity LED
Drive
Ready
Drive
Activity
Drive Fault
Key
Lock
Carrier Handle
IFS14_3
LEDs
10 User Interface
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Inserting a Drive Carrier (with Drive Installed)
NOTES: A new drive can be inserted into an empty bay at anytime. However, the drive
will not be ready for access until the following procedure is followed.
The key lock is only to prevent unauthorized removal or installation of the drive
carrier. Locking the key lock is not required for drive carrier operation.
1. Simply insert the drive carrier into the empty bay.
2. Drive is ready to be accessed when the Drive Ready LED glows. .
Removing a Drive Carrier (with Drive Installed)
CAUTION: Proper procedure must be followed when removing a disk drive from the drive
bay. It is the responsibility of the operator to ensure that the host does not
access the drive while attempting to remove the disk drive, and to follow the
procedure outlined below. Failure to do so may result in loss of data and/or
damage to the drive itself!
NOTE: Refer to the InfoStation Installation Guide for detailed information on inserting/
removing drives from the InfoStation chassis.
1. Verify that the Drive Activity LED is OFF before removing drive.
2. Unlock the key lock (if locked) and remove the drive carrier by pulling on carrier handle.
Configuring Device and Chassis Settings
NOTE: Refer to the InfoMon User's Guide for further information.
If necessary, use InfoMon to change any factory default device or chassis settings. Please refer to the InfoMon User's Guide for further information.
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Fibre Channel Configurations 11
FIBRE CHANNEL CONFIGURATIONS
Port Bypass (PBP) Module
CAUTION: DO NOT bend the LC (optical) cable beyond the cable's minimum bend radius,
data transmission degradation may occur. Follow cable manufacturer's guidelines for bend radius limitation.
WARNING: DO NOT look directly into the open end of an active LC (optical) cable or optical
SFP module (with plugs removed)! Serious eye damage can occur from direct exposure to the infrared light!
NOTES: PBP Module is NOT hot-swappable! Remove ALL power to chassis before
removing and installing the PBP Module. Refer to the InfoStation Installation Guide for further information.
SFP Module is hot-swappable. The chassis may remain on when removing and installing the SFP Module.
HSSDC2 (copper) SFP Modules support 1Gbps operation only.
LC (optical) SFP Modules support both 2Gbps and 1Gbps operation.
Auto Loopback is enabled when there are no SFP Modules installed in the open Host ports.
An additional PBP Module is available as an upgrade. Contact StorCase for further ordering information.
Figure 7: PBP Module
SFP Cages - Four (4) cages accept optional SFP Modules and allow for two (2) FC-AL
and Loop Expansion.
SFP Module - Optional module supports LC (optical) or HSSDC2 (copper) connections.
14FC_04
LEDs
Locking
Thumbscrew
PBP Module
Handle
HSSDC2
SFP Module
(Optional)
SFP
Cages
In InOut Out
Loop B Loop A
12 Fibre Channel Configurations
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
PBP Module LEDs
DIAG ON = Communication link to UI has failed
OFF = Normal operation
All Bypass ON = All drives are forced into bypass
Loop A ON = Error detected in the Loop A data input Data In Error
Loop A ON = Error detected in the Loop A data output Data Out Error
Loop B ON = Error detected in the Loop B data input Data In Error
Loop B ON = Error detected in the Loop B data output Data Out Error
DIAG
Loop A
Data In Error
Loop B
Data In Error
All Bypass
Loop A Data Out Error
Loop B Data Out Error
Figure 8: PBP Module LEDs
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Fibre Channel Configurations 13
SFP Module and Cable Installation
CAUTION: DO NOT bend the LC (optical) cable beyond the cable's minimum bend radius,
data transmission degradation may occur. Follow cable manufacturer's guidelines for bend radius limitation.
WARNING: DO NOT look directly into the open end of an active LC (optical) cable or optical
SFP module (with plugs removed)! Serious eye damage can occur from direct exposure to the infrared light!
NOTES: SFP Module is hot-swappable. The chassis may remain on when removing and
installing the SFP Module.
HSSDC2 (copper) SFP Modules support 1Gbps operation only.
LC (optical) SFP Modules support both 2Gbps and 1Gbps operation.
Auto Loopback is enabled when there are no SFP Modules installed in the open Host ports.
An additional PBP Module is available as an upgrade. Contact StorCase for further ordering information.
Depending on model, your InfoStation may or may not have been shipped with SFP Modules already installed. If already installed, skip Step 1 and proceed with Step 2.
1. Carefully insert SFP Module(s) into the appropriate SFP cages (depending on FC configuration) located on the PBP Module (Figures 9A & 9B). Insert and push the SFP Module until it "clicks" into place.
WARNING: To avoid possible damage to the LC (optical) SFP Module, make sure the Release
Lever is on top before inserting SFP Module into the PBP Module (Figure 9A)!
To avoid possible damage to the HSSDC2 (copper) SFP Module, make sure the Release Tab is on the bottom before inserting the SFP Module into the PBP Module (Figure 9B)!
Refer to Figures 11-16 for further information on FC configurations.
14 Fibre Channel Configurations
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Figure 9A: Installing the LC (optical) SFP Module into the PBP Module
Figure 9B: Installing the HSSDC2 (copper) SFP Module into the PBP Module
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Fibre Channel Configurations 15
2. Remove the SFP plugs (Figure 9A) and install the cables into the SFP Modules (Figure
10). Make sure to remove any cable plugs from the cables prior to installation (if necessary). Save SFP and cable plugs for future use!
WARNING: DO NOT look directly into the open end of an active LC (optical) cable or optical
SFP module (with plugs removed)! Serious eye damage can occur from direct exposure to the infrared light!
Figure 10: Installing the Cables into the SFP Modules
16 Fibre Channel Configurations
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
3. To remove SFP Module from PBP Module, remove any cables installed in the SFP Module.
For Optical SFP Modules, lower the Release Lever and pull the SFP Module from PBP Module (Figure 11).
For HSSDC2 SFP Modules, squeeze the Release Tab while pulling the SFP Module from the PBP Module.
WARNING: DO NOT look directly into the open end of an active LC (optical) cable or optical
SFP module (with plugs removed)! Serious eye damage can occur from direct exposure to the infrared light!
Figure 11: Removing the Optical SFP Module from the PBP Module
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Fibre Channel Configurations 17
FC Loop and Speed Configuration
NOTES: Factory default configuration is Dual Loop at 2Gbps.
Refer to the InfoMon User's Guide for further information.
If necessary, use InfoMon to change any factory default device or chassis settings. Please refer to the InfoMon User's Guide for further information.
Hardware Compatibility
To assure maximum system compatibility and performance, StorCase recommends Seagate
®
Fibre drives for use in our InfoStation Fibre backplane enclosures.
Please contact StorCase Technical Support to obtain specific part numbers for the latest StorCase-qualified Fibre drives, as well as recommendations regarding the compatibility of specific RAID controllers with the InfoStation enclosure.
18 Fibre Channel Configurations
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
TYPICAL FIBRE CHANNEL CONFIGURATIONS
NOTES: The installation, configuration, and use of the StorCase InfoStation chassis
requires a certain level of expertise and experience on the part of the user/ integrator. Since there are many configuration options and variables (ie. host platforms, applications, etc), only general/typical configuration guidelines will be discussed in this User's Guide.
For redundant loop configurations, make sure your O/S supports disk duplexing/ mirroring. Refer to O/S manufacturer's documentation for further information.
An additional PBP Module is available as an upgrade. Contact StorCase for further ordering information.
Figure 12: Typical Single 14-Device Loop Configuration (Single Chassis)
FC-AL #1
PC
FC HBA
Host 0
NOTES: Auto Loopback is enabled when there are no SFP Modules installed in the open
Host ports.
SFP modules are optional. Contact StorCase for further ordering information.
Up to 9 InfoStations or 126 FC Drives maximum.
= SFP Module Installed
= No SFP Module Installed (Auto Loopback)
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Fibre Channel Configurations 19
Figure 13: Typical Single 14-Device Loop Configuration (Multiple Chassis)
NOTES: Auto Loopback is enabled when there are no SFP Modules installed in the open
Host ports.
SFP modules are optional. Contact StorCase for further ordering information.
Up to 9 InfoStations or 126 FC Drives maximum.
FC-AL #1
PC
FC HBA
Host 0
= SFP Module Installed
= No SFP Module Installed (Auto Loopback)
20 Fibre Channel Configurations
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Figure 14: Typical Redundant 14-Device Loops Configuration
NOTES: Auto Loopback is enabled when there are no SFP Modules installed in the open
Host ports.
SFP modules are optional. Contact StorCase for further ordering information.
Up to 9 InfoStations or 126 FC Drives maximum.
For redundant loop configurations, make sure your O/S supports disk duplexing/mirroring. Refer to O/S manufacturers documentation for further information.
FC-AL #1
PC
Dual Loop
FC HBA
Host 0
= SFP Module Installed
= No SFP Module Installed (Auto Loopback)
FC-AL #1
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Fibre Channel Configurations 21
NOTES: Auto Loopback is enabled when there are no SFP Modules installed in the open
Host ports.
SFP modules are optional. Contact StorCase for further ordering information.
Up to 9 InfoStations or 126 FC Drives maximum
FC-AL #2
PC
FC HBA
Host 1
PC
FC HBA
Host 0
FC-AL #1
= SFP Module Installed
= No SFP Module Installed (Auto Loopback)
Figure 15: Typical Dual 7-Device Loops Configuration
22 Fibre Channel Configurations
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Figure 16: Typical Redundant Dual 7-Device Loops Configuration
NOTES: Auto Loopback is enabled when there are no SFP Modules installed in the open
Host ports.
SFP modules are optional. Contact StorCase for further ordering information.
Up to 9 InfoStations or 126 FC Drives maximum.
For redundant loop configurations, make sure your O/S supports disk duplexing/mirroring. Refer to O/S manufacturers documentation for further information.
FC-AL #2
FC-AL #1
PC
Dual Loop
FC HBA
Host 0
PC
Dual Loop
FC HBA
Host 1
= SFP Module Installed
= No SFP Module Installed (Auto Loopback)
FC-AL #2 FC-AL #1
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Fibre Channel Configurations 23
NOTES: Auto Loopback is enabled when there are no SFP Modules installed in the open
Host ports.
SFP modules are optional. Contact StorCase for further ordering information.
Up to 9 InfoStations or 126 FC Drives maximum
FC-AL #2
FC-AL #1
FC-AL #3
FC-AL #4
PC
FC HBA
Host 2
PC
FC HBA
Host 1
PC
FC HBA
Host 3
PC
FC HBA
Host 0
= SFP Module Installed
= No SFP Module Installed (Auto Loopback)
Figure 17: Typical Quad Loops Configuration
24 Fibre Channel Configurations
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
This Page Left Blank Intentionally.
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Appendix A - Specifications/Dimensions 25
APPENDICES
26 Appendix A - Specifications/Dimensions
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
The following InfoStation specifications and dimensions are provided for reference only.
Appendix A - Specifications/Dimensions
Physical Specifications
Rack Mount
Height
5.21" (132.3mm)
Width
16.92" (429.8mm)
Depth 20.98" (532.9mm)
(1)
Environmental Specifications
Operating
Storage
Ambient Temperature 0° C to 35° C -40° C to 70° C Relative Humidity
(1)
10% to 80% 10% to 90%
Altitude
-1000 to 10,000 ft -1000 to 40,000 ft
-305m to 3048m -305m to 12195m
Shock
(2)
10g 60g
(1)
Non-condensing with maximum gradient of 10% per hour
(2)
11 msec pulse width 1/2 sine wave
Weight
52.0 lbs (28.6kg)
Weight of empty chassis (no drives installed) and 1 P. S. Module. 62.0 lbs with 2 P. S. Modules
Electrical Specifications
(per 650W Power Supply Module)
AC Input
DC Output
Chassis Reliability/Maintainability
MTBF 100,000 Hours
Preventive Maintenance
Power Supply Module
14FC_specs1
100 to 120VAC or 200 to 240VAC, 50/60 Hz
5V at 53A, 12V at 32A
I/O Module
79 CFM
Cooling
(per Blower Module)
(1)
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Appendix A - Specifications/Dimensions 27
StorCase InfoStation
Fibre Channel Rack Mount Enclosure
14 Bay
# of BaySupported 14
# of Drive Carriers Included 14
Max. # of Drives Supported 14
Max. Storage Capacity 2.05TB
(Based on 147GB Drives)
Hot Swappable Yes LED Status Indicators Yes
Interface SCA
Protocol Fibre Channel Transfer Rate 2 Gbps
User Interface LED Read-Out and Yes Control Panel
# of Power Supply/Blower Modules 1 or 2
Redundant Yes Hot Swappable Yes Speed-Variable Auto Blowers/Fans 2 Blowers/Module
# of PBP Modules 1 or 2
Max. # of Configurable FC Loops 4
Data Rate
HSSDC2 (copper) 1Gbps LC (optical) 2Gbps/1Gbps
Maximum Cable Length
HSSDC2 (copper) 5m LC (optical) - 62.5/125 um 150m
(2Gbps)
/ 300m
(1Gbps)
- 50/125 um 300m
(2Gbps)
/ 500m
(1Gbps)
Optical Wavelength (LC only) 850 nm
Distributed Environmental Monitoring Yes
28 Appendix A - Specifications/Dimensions
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
* 3 year limited warranty on Power & Cooling Modules.
StorCase InfoStation
Fibre Channel Rack Mount Enclosure
External Monitoring Utility Yes via RS-232 Port
Power-On-Hour (POH) Yes Monitoring
Audible Alarm Yes
Standard 19 Rack-Mount Height = 3U
Technical Support Toll-Free
Limited Warranty 7 Years*
Regulatory Approvals
EMI FCC/CE/C-tick Safety Agency CSA/CSA US/TUV
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Appendix A - Specifications/Dimensions 29
Figure A-1: InfoStation Physical Dimensions
(Dimensions are for reference only)
Top View
Right Side ViewFront View
5.21 (132.3mm)
20.57 (522.5mm)
16.92
(429.8mm)
18.98
(482.1mm)
20.98
(532.9mm)
14FC_dims
30 Appendix B - Optional Accessories
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Figure B-1: PBP Module
Appendix B - Optional Accessories
Port Bypass Module
The InfoStation's scalable backplane design allows additional modules to be offered, supporting a variety of FC configurations. An additional PBP module (P/N S10D107) is availa­ble to upgrade the InfoStation for quad loop applications.
Contact StorCase for further ordering information.
14FC_12
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Appendix B - Optional Accessories 31
SFP Modules
HSSDC2 (Copper) SFP Module
(P/N S10D108)
Figure B-3: LC (Optical) SFP Modules
Figure B-2: HSSDC2 (Copper) SFP Modules
14FC_14
14FC_15
LC (Optical) SFP Module
(P/N S10D114)
32 Appendix B - Optional Accessories
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Figure B-4: Patch Cable Kit
Patch Cable Kit
(P/N S90D100)
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Appendix B - Optional Accessories 33
Slide Rail Kit
The optional slide rail kit (P/N DXRCK-SLIDE) provides a convenient method to attach the InfoStation to a rack mount enclosure (Figure B-5). These high quality, durable rails provide 24 ball bearing rollers and have a quick-release button which allows quick and easy installation and removal of the InfoStation unit from its rack enclosure. Contact StorCase for further ordering information.
Figure B-5: Rack Mount Slide Rail Kit
IFS14_29
34 Appendix B - Optional Accessories
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Optional Power Supply/Blower Module
CAUTION: The power supply/blower module contains NO USER SERVICEABLE
PARTS inside the unit. Warranty is VOID if module is opened. Refer ALL servicing to qualified service personnel!
NOTE: Refer to the InfoStation Installation Guide for further information.
An optional second 650W power supply module (P/N S10D109) is available for the InfoStation chassis as shown in Figure B-6. Contact StorCase for further ordering information.
Figure B-6: Power Supply/Blower Module
14FC_13
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Appendix B - Optional Accessories 35
Drive Carrier
Spare drive carriers (P/N S10A116) are available for the InfoStation chassis as shown in Figure B-7. Contact StorCase for further ordering information.
Figure B-7: Drive Carrier
IFS14_25
36 Appendix B - Optional Accessories
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Carrying Case
(Figure B-8)
The optional molded plastic carrying case (P/N S20E104) is designed to transport the InfoStation drive carrier from one site to another in a safe, impact and moisture resistant environment. Its compact dimensions, 7" long x 9" wide x 4" high, make it easy to carry and store. The foam lining is contoured to fit a single InfoStation carrier. Contact your StorCase dealer for further details and ordering information.
Figure B-8: Carrying Case
320FW_13
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Appendix B - Optional Accessories 37
Rack-to-Tower Conversion Kit
This kit (P/N S10E100) provides all the parts necessary to convert an existing rack mount InfoStation to a tower conversion as shown in Figure B-9. Contact StorCase for further ordering information.
Top
Cover
Top Cover
Base
Left
Cover
Bezel*
Base
Pan Hd.
Screw
(4 Total)
Pan Hd.
Screw
(1 Total)
Pan Hd.
Screw
(4 Total)
Right Cover
F.H. Screw
(1 per Side)
Hex Nut*
(4 Total)
F.H. Screw*
(4 Total)
* Chassis handles and mounting flanges must be removed prior to installation.
Figure B-9: Rack-to-Tower Conversion Kit
38 Appendix B - Optional Accessories
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
InfoStation Monitoring Utility (InfoMon®)
InfoMon is a web-based monitoring utility that runs under the Windows O/S. This free utility (and its accompanying User's Guide) is available for download at the StorCase web site (http://www.storcase.com).
The primary purpose of InfoMon is to continuously monitor the environmental status and indicate alarm conditions inside the InfoStation chassis via a serial connection to a PC. InfoMon also provides the User the ability to easily configure both device and chassis settings with a few clicks of the mouse!
In addition, InfoMon allows the User to monitor the statuses and temperatures of individual InfoStation modules and drive bays, etc., and can provide "real-time" updates via an Internet connection. With the recent addition of the InfoMon Call Home feature, this information can also be sent to a specific site for access by StorCase technical support staff in order to assist with system troubleshooting. The Call Home feature also provides the ability to set-up a paging function for notification of environmental alarm or warning conditions.
To install and operate the InfoMon software, the computer system must meet the following requirements:
Operating System: Microsoft® Windows® 95/98/NT/2000/XP CPU: IBM-compatible 486 or higher Memory: 32MB RAM Hard Disk Space: 12MB Internet Connection: Required only if monitoring via the web Internet Browser: Microsoft Internet Explorer 5.0 (or higher) or
Netscape Communicator 4.7 (or higher)
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Reader's Comments 39
Reader's Comments
Please take a few moments when your computer system is up and running to send us your ideas and suggestions for improving our products and documentation. Did the installation go smoothly for you? Are there any changes you would like us to make, either with the hardware itself, or with the installation instructions? Everyone at StorCase Technology is working toward the goal of providing you with the highest quality, most cost effective, products available on the market, and we need your comments to guide our efforts. We look forward to hearing from you soon!
Date:
Your Name:
Address:
Telephone: ( )
To mail this page, carefully remove it from the manual, fold it, staple or tape it shut, and drop it in the mail. To FAX this page, carefully remove it from the manual (or make a photocopy) and FAX it to us at (714) 438-1847. Thank you for taking the time to help us make our products better!
40 Reader's Comments
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
FOLD ALONG THIS LINE AND STAPLE SHUT
CUT ALONG THIS LINE FROM BOTTOM TO TOP OF PAGE
BUSINESS REPLY MAIL
POSTAGE WILL BE PAID BY ADDRESSEE
NO POSTAGE
NECESSARY
IF MAILED
IN THE
UNITED STATES
FIRST CLASS MAIL PERMIT NO. 10686 SANTA ANA, CA
TECHNOLOGY CORPORATION
17600 NEWHOPE STREET FOUNTAIN VALLEY CA 92708-9885
Loading...